APPLIED SYSTEMS

139 downloads 347 Views 11MB Size Report
Rhoss is a company of Irsap group specialised in the design and production of air conditioning and air handling ..... MCAE-MHAE 105÷127. Hermetic rotary ...
WATER CHILLERS • HEAT PUMPS • FAN COIL UNITS • TERMINAL UNITS • FOR RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS.

2010

APPLIED SYSTEMS

Product Catalogue

Arquà Polesine (RO) - Italy

Codroipo (UD) - Italy

Cluj Napoca - Romania

Beijing - China

Barcelona - Spain

Baligen - Germany

key production sites subsidiaries distributors

Arquà Polesine (RO) - Italy

Lyon - France

One of the largest Italian groups in the heating and air conditoning industry. Our mission Improve quality of life in public, residential and tertiary sector with a highly specialised offer of products and services for air conditioning, with maximum attention to customer needs and from the point of view of sustainable development suited to green building technologies. Know-how and experience at the service of specialists

Since 1963, RSAP has been a

OFFICINA DELLE IDEE line

Since 1968, RHOSS has worked

IR TECH is a company special-

leader in the production of

dedicated to design radiators.

in the public and industrial air

ised in radiant cooling and

steel tubular radiators. IRSAP

OFFICINA DELLE IDEE intro-

conditioning sector.

heating system and renew-

is the pulsating heart of the

duces an unmistakable style

RHOSS is a breath of fresh air for

able sources.

group: it combines the heat of

to every environment, giving a

your body and mind, thanks to

IR TECH designs solid bases for

fire with a burning passion for

form to every desire.

products and systems that in-

climate management and is

novate air conditioning.

able to “irradiate“ innovation

well-being.

and professionalism.

2002

2000

OBJECTIVE “CONTINUOUS IMPROVEMENT“

Reengineering of the product range and expansion of the production lines with the implementation of a testing cabin on each line.

CTA ADVANCE a new range of “Custom” air handling units

PLAN FOR ENERGY EFFICIENCY AND FOR THE DESIGN The Eurovent approved Research and Development laboratory has been created, which guarantees and certifies the requested performance.

Eurovent certification for chilllers, heat pumps and fan coil units.

2005

EXP has been created, an innovative polyvalent heat pump for 2 and 4-pipe applications.

New EV series fan coil units (Brio EV and Yardy EV), with high performance and an exclusive design.

Introduction of the R134a and R410A range for maximising energy performance.

Who is RHOSS Rhoss is a company of Irsap group specialised in the design and production of air conditioning and air handling products and systems. For more than 40 years, Rhoss has been a guarantee for innovation, quality and top level service. This is what makes us an ideal partner for HVAC system specialists. RHOSS's growth and development is an evolution that combines investments and projects in order to make the company a point of reference also in international markets. Our renewal has followed market developments and customer needs, in particular offering highly efficient products and systems that are in line with the requirements of the most modern Green Buildings.

Two other innovations include Dry-Pool, the first dehumidifier for pools in R410A, with heat recovery and Yardy HP, a high performance ducted fan coil unit.

Development of innovative solutions to maximise comfort and energy saving performance. We have a permanent research contract with Universities to support innovation.

“Low consumption" technology for managing R410A chillers and heat pumps, to reduce seasonal energy consumption.

FROM THE PRODUCT TO THE SYSTEM

2010

TECHNOLOGICAL INNOVATION

A MODULAR range of air handling units with regulation with high service levels.

2008

Y-M.I.C.H. has been created, inverter technology used for chillers and heat pumps.

Heating, cooling and hot water production solutions based on high performance, NF certified heat pumps

From machine certification to system certification in reference to the main air quality and environmental comfort measurement standards. IR TECH, a radiant air conditioning division of Rhoss, offers an advanced integrated system that maximises comfort, reducing the system's energy requirements. The innovative system was developed in Rhoss's new R&D Lab, which is able to simulate a buildingunit system.

Conscious design for a conscious choice RHOSS bases its design philosophy on one fundamental concept; testing the behaviour of its produced machines in all the environmental conditions in which they can be used. A responsible manufacturer must in fact provide designers with correct data regarding its products under all operating conditions, because each air conditoning unit must deliver a specific energy performance that can vary based on geography, building features and use requirements. With its testing rooms, Rhoss's R&D Lab provides its customers with a series of guarantees that are necessary for a conscious design:



guarantee of performance under the design conditions, which are usually different than Eurovent nominal conditions;



guarantee of efficiency at full load (EER, COP) or at partial loads (ESEER);



guarantee of continuous operation, especially under the most critical operating conditions: simply think of severe climates where the ambient air can exceed 50 °C or go down below –15 °C.



the possibility for the design or end customer to carry out customised tests

Therefore, Rhoss is able to offer products designed for large and small capacity systems, guaranteeing that all the components used are integrated together, with a perfect control logic. This result can only be obtained in laboratories such as Rhoss's R&D Lab, that is, in a complex, technically advanced structure that most other manufacturers today do not have.

A complete offer for HVAC specialists Rhoss's offer is targeted towards specialists in the HVAC world. Rhoss technicians and engineers are constantly engaged in developing air conditioning, heating and air handling products and systems for applications such as residential, offices, hotels and hospitality structures in general, hospitals, airports and industry. For each of these applications, Rhoss's solution is targeted towards improving energy efficiency, environmental comfort and air handling processes. For this reason, Rhoss products and systems are divided into four well focused catalogues.

APPLIED SYSTEMS Chillers, fan coil units and terminal units for public, commercial and industrial applications, for small and large systems.

HEAT PUMPS Heat pumps and heating, cooling and hot water production solutions specifically for residential and small service industry applications.

AIR HANDLING SYSTEMS Air handling units for public, commercial and industrial uses. Dehumidifiers for indoor pools.

RADIANT SYSTEMS Radiant air conditioning systems that integrate floor, wall and ceiling terminals with chillers/heat pumps, air handling units and complete system regulation. The offered solutions are specific for residential, commercial and large building applications.

Sustainable RHOSS technology is recognisable In each catalogue, Rhoss offers solutions that promote sustainable construction in terms of energy efficiency, in line with the requirements of modern Green-Buildings. These are products or systems that were designed with technology that makes it concretely possible to reduce the energy needs of the HVAC system, but without reducing the comfort in the building where it is installed. The Rhoss solutions that excel in sustainability can be easily recognised by the Green Line mark, which represents Rhoss's respect for the environment.

The Green-Line products are: •

The class A chillers in the Z-Power, Z-Flow and T-Power ranges



the total recovery polyvalent heat pumps in the EXP range



the Mini-Y, Compact-Y, Y-Pack and Y-Flow chillers and heat pumps with exclusive, patented AF+ technology



the chillers with free-cooling technology in the Y-Pack range



the chillers with both scroll (Y-MICH range) and magnetic levitation centrifugal (T-Power range) inverter compressors



the new MODULAR air handling unit range with EC fans



the CTA ADV range with multiple heat recovery solutions

The Green-Line systems are: •

Systems based on high efficiency heat pumps specifically for residential and small service industry solutions. Thanks to the wide range of plant engineering solutions, these systems make it possible to meet the entire heating and hot water production requirement using renewable sources



The solutions from the IR TECH division: integrated radiant air conditioning and air handling solutions

How to recognise the Green-Line It is possible to recognise the Green-Line products and systems in each RHOSS catalogue thanks to the logo included in the description of the features.

RHOSS certifications: quality recognised by experts EUROVENT CERTIFICATION FOR CHILLERS, HEAT PUMPS AND FAN COIL UNITS Rhoss participates in the Eurovent certification programme for coolers, heat pumps and fan coil units, which includes: • Certification of the air conditioning and heating capacities according to the EN 14511 standard; • Sound power level certification according to the ISO 9614 standard and Eurovent 8/1 standard • Certification of chiller efficiency through the measurement of the EER (Energy Efficiency Ratio) index • Certification of heat pump efficiency through the measurement of the COP (Coefficient of Performance) index • Certification of chiller efficiency at partial loads through the measurement of the ESEER (European Seasonal Energy Efficiency Ratio) index • Certification of the fan coil unit performance according to the Eurovent 6/3 standard “Thermal Test Method for Fan Coil Units” • Certification of fan coil unit sound pressure performance according to the Eurovent 8/2 standard “Acoustic Tests for Fan Coil Units in a reverberant chamber”

AH U Ra -09 ng .07 e- .3 AD 61 V

EUROVENT CERTIFICATION FOR AIR HANDLING UNITS Rhoss participates in the certification programme for air handling units with the ADV range that includes: • Certification of performance according to the EN 13053 standard • Certification of the mechanical features according to EN1886 • Energy classification of the machines

ECA CERTIFICATION FOR CHILLERS The Rhoss chillers in the Y-Pack, Y-Power, Z-Power ranges and in the industrial range have also received ECA - Enhanced Capital Allowances - certification, which is a key programme from the English government that promotes criteria for energy savings and environmental wellness. ECA makes it possible for companies in the United Kingdom to benefit from tax incentives for investments in equipment, in the specific case of chiller assemblies, that satisfy certain energy efficiency values and are therefore able to contribute towards energy savings and a reduction in carbon emissions as set forth by the Kyoto protocol.

NF PAC CERTIFICATION FOR HEAT PUMPS The Rhoss Mini-Y, Compact-Y and Compact HT heat pumps are NF PAC certifified, which is a voluntary certification of quality that is issued by the French certification agency AFAQAFNOR. NF PAC applies to heat pumps with a heating capacity of up to 50 kW and certifies performance in terms of minimum COP, heating capacity and sound power level, in accordance with the requirements of the NF PAC Regulation. Before issuing the NF PAC certification, AFAQ-AFNOR carries out performance tests on the heat pumps representative of the certified ranges and performs company audits to evaluate manufacturer reliability.

Global services and solutions for public and industrial air conditioning THE “VALUE” FOR HVAC SYSTEM USERS Rhoss Smile Service aims to find solutions to your problems, meeting all of your needs regarding air conditioning, heating and air ventilation equipment installed all over the world. Rhoss Smile Service creates service programmes and instruments that makes it possible for us to always serve you better. Which are the most significant added value aspects for a HVAC system user? 1. 2. 3. 4. 5. 6. 7. 8.

obtaining constant performance without problems or concerns optimising equipment operation minimising energy consumption keeping maintenance costs low eliminating operational losses limiting inactive times foreseeable cost management compliance with local governmental and environmental regulations

START-UP AND WARRANTY EXTENSIONS All units in the Applied Systems division include a manadatory start-up in the national territory that foresees a series of operations that adapt machine operation as best as possible to the type of system and application to which it is connected. Extended warranties are possible for all Rhoss units, which include labour and replacement parts for parts that are defective during the preselected extension period. Warranty coverage requires the execution of all ordinary maintenance operations that, if not carried out by specialised Rhoss Smile Service technicians, and therefore not included in the contract, must be guaranteed and warranted by qualified personnel. RHOSS SMILE SERVICE CONTRACTS The scheduled maintenance contracts (Basic, Program, Full Service and Global) are customised programmes to suit your needs, your company and your application. They are designed to offer operative efficiency, extend the useful life of your system and help reduce operational costs. Selecting a Rhoss Smile Service contract is an antistress strategy. The advantages of purchasing a Rhoss Smile Service contract are unquestionable: in addition to having greater response priority, maintenance and component coverage, customers who sign a contract have the advantage of efficient planning and money savings. In fact, with a service contract administrative costs and internal and external labour costs are reduced substantially, and provide operational cost savings. The longer the contract, the more you save. Rhoss Smile Service contracts can be signed for a period of up to 10 years.

S E RV I

CES

systems: Smile Service. REMOTE SUPERVISION Continuous control and the quickest and most effective service form: via a normal Gprs data line, the Rhoss Smile Service control system dialogues 24x7 with all installed systems without distance limits. You do not need to call: each small status change is signalled automatically and if an alarm signal is received, the closest technician qualified for your specific system will be contacted immediately. RENTING UNIT The right machine at the right moment and for the necessary amount of time: Rhoss Smile Service also means medium and long term renting of air conditioning and heating equipment. Rhoss Smile Service offers a wide range of versatile machines that can satisfy all cooling needs with an “all inclusive” formula. The supply foresees a turn-key rental, quick and timely coverage of any risk connected to maintenance and operating costs. The fixed rates represent certain costs that simplify accounting and a company's financial forecasts with rental fees being considered “operational costs” and therefore fully deductible. Customers can add to or replace their equipment at any moment with a fee adjustment. UNIT REASSEMBLY SERVICE Increasingly often, architectural barriers and structural constraints make it impossible to replace units in areas that are difficult to reach due to weights and dimensions that do not conform with the available spaces. Rhoss Smile Service has a team of specialised technicians who are able to perform on site disassembly and reassembly operations for the machine to be positioned according to the general diagram shown below. EXTRAORDINARY MAINTENANCE If units not covered by Rhoss Smile Service contracts and no longer in the warranty period have defective vital machine components, the Rhoss Smile Service team is able to accept any request for service and will quickly organise: a technical inspection, preparation of a repair estimate, repair service following approval of the estimate, 12 months warranty on the work that was performed and reactivation of the global warranty for an additional 6 months starting from the date the work was completed. SPECIALISED TECHNICAL COURSES In a very competitive environment, training is a very strategic part of business. Every year, training, updating and specialisation courses are planned at the Rhoss training centre and laboratory. These courses are dedicated to specific air conditioning and cooling issues, and in particular: acoustics and noise, energy savings regulations, replacement of R22: ecological alternatives, new R410A - R134a coolants: system use and maintenance, screw compressors, Turbocor compressors, radiant systems (regulation and applications), air handling units with regulation, Supervisor, Modbus, Carel (Lonworks, Bacnet), Idrhoss (applications with supervisor and GSM) protocols.

S O LU T

IONS

Contents 14

Applied Systems WATER CHILLERS - HEAT PUMPS Air cooled - Axial fans Cooling capacity: 5.5-11.1 kW

Cooling capacity: 5.5-11.1 kW Low consumption Mini-Y range

P.20

TCAEY 105÷111

Heating capacity: 5,8÷11,9 kW Low consumption Mini-Y NF range

Hermetic Scroll compressors

Hermetic Scroll compressors GREEN LINE

Cooling capacity: 15,4÷38,8 kW

Heating capacity: 16,8÷41,7 kW Low consumption Compact-Y range

GREEN LINE

Cooling capacity: 13,4÷27,8 kW P.24

TCAEY-THAEY 115÷238

Heating capacity: 15,6÷31,7 kW Low consumption Compact-Y range Hermetic Scroll compressors

GREEN LINE

Heating capacity: 47,8÷67,9 kW Low consumption Compact-Y range

GREEN LINE

Cooling capacity: 23,8÷48,5 kW P.28

TCAEY-THAEY 245÷265

Heating capacity: 27,3÷54,3 kW Y-M.I.C.H. Range Hermetic Scroll compressors Inverter

GREEN LINE

Heating capacity: 79÷175 kW Low consumption Y-Pack range

GREEN LINE

Cooling capacity: 262-389 kW P.32

TCAEY-THAEY 270÷2160

Heating capacity: 160÷342 kW Low consumption Y-Pack range

P.34

TCAEY-THAEY 4160÷4320

Hermetic Scroll compressors

Hermetic Scroll compressors GREEN LINE

Cooling capacity: 170-361 kW

GREEN LINE

Cooling capacity: 331,4÷455,1 kW Y-Pack Range FREECOOLING

P.30

TCAIY-THAIY 124-150

Hermetic Scroll compressors

Cooling capacity: 262-389 kW

P.26

TCAEY-THAEY 118÷136 H.E.

Hermetic Scroll compressors

Cooling capacity: 44,2÷64 kW

P.22

THAEY 105-111 NF

P.36

TFAEY-TGAEY 4160÷4320

Heating capacity: 353,4÷486,2 kW Y-Power Range

P.38

TCAEY-THAEY 5350÷6450

Hermetic Scroll compressors

Hermetic Scroll compressors GREEN LINE

Cooling capacity: 262-389 kW

Cooling capacity: 324.8-693.2 kW Z-Power Range

P.40

Z-Power Range

TCAVZ 1270÷1390

P.42

TCAVZ 2330÷2700 H.E.

Semi-hermetic screw compressors

Semi-hermetic screw compressors

GREEN LINE

Cooling capacity: 297.5-665.9 kW

Cooling capacity: 746-1,283.4 kW Z-Power Range

P.44

Z-Power Range

TCAVZ 2310÷2670

P.46

TCAVZ 2770÷21290 H.E.

Semi-hermetic screw compressors

Semi-hermetic screw compressors

GREEN LINE

Cooling capacity: 732-1,602 kW

Cooling capacity: 262-389 kW Z-Power Range

TCAVZ 2710÷21600 Semi-hermetic screw compressors

P.48

Heating capacity: 409÷700 kW Z-Power Range

THAVZ 2400÷2680 Semi-hermetic screw compressors

P.50

P.52

T-Power Range

TCATBZ 1250-2600/ TCATTZ 1260-41280 H.E. Oil-free centrifugal compressors

GREEN LINE

Water-cooled - Centrifugal fans Cooling capacity: 4,8÷10,4 kW

Heating capacity: 5÷11 kW Low consumption Mini-Y range

Cooling capacity: 13,5÷22 kW P.54

TCCEY-THCEY 105÷111

Heating capacity: 13,6÷24 kW Compact Range

P.56

TCCE-THCE 114÷126

Hermetic Scroll compressors

Hermetic Scroll compressors GREEN LINE

Cooling capacity: 30,1÷66,3 kW

Heating capacity: 34,9÷77,1 kW

TCCE-TCPE-THCE-THPE 130÷270

AIR cooled CENTRIFUGAL fans

WATER CHILLERS HEAT PUMPS

Cooling capacity: 250-1,280 kW

P.58

INDUSTRIAL & PROCESS COOLING

Hermetic Scroll compressors

Air-cooled - Condenserless units TCHEY-THHEY 105÷112

Heating capacity: 17,36÷44,9 kW Low consumption Y-Flow range

Hermetic Scroll compressors

Hermetic Scroll compressors GREEN LINE

Cooling capacity: 45,2÷450,8 kW

Heating capacity: 50÷512,7 kW Low consumption Y-Flow range

P.62

TCHEY-THHEY 115÷240 GREEN LINE

Cooling capacity: 204-1,635 kW P.64

Z-Flow Range

TCHEY-THHEY 245÷4450

P.66

TCHVZ 1201÷31631 H.E.

Hermetic Scroll compressors

Semi-hermetic screw compressors GREEN LINE

Cooling capacity: 199.7-1,629.2 kW

GREEN LINE

EXP Polyvalent systems

Cooling capacity: 15,5÷41,8 kW P.60

CONDENSING UNITS

Heating capacity: 6,5÷13,9 kW Low consumption Comby-Flow range

Cooling capacity: 5.5-249 kW Z-Flow Range

P.68

TCHVZ 1200÷31630 Semi-hermetic screw compressors

Mini-Q Flow E Range (mod. 105-115) Compact Flow E Range (mod. 120-165) Q-Flow E Range (mod. 280-4260)

TCEE 105÷4260 Hermetic Scroll compressors

P.70

SYSTEM ACCESSORIES

Cooling capacity: 5.5-249 kW

Semi-hermetic screw compressors

Industrial & process cooling: Industrial Range P. 74 - Wine Range P. 75 Cooling capacity: 15.4-161.9 kW Industrial & Process Cooling Range

P.76

TCAEY 118÷2189 Hermetic Scroll compressors

GREEN LINE

TERMINAL UNITS

P.72

TCEVZ 1200÷31630

FAN COIL UNITS

Cooling capacity: 171.9-1,424.8 kW Z-Flow E Range

AIR cooled AXIAL fans

15

INDOOR INSTALLATION

WATER cooled CONDENSERLESS UNITS

INDOOR INSTALLATION

WATER CHILLERS HEAT PUMPS

HEAT PUMP

WATER CHILLERS HEAT PUMPS

COOLING ONLY

16

EXP - Polyvalent systems P. 78 Cooling capacity: 17,4÷34 kW

Heating capacity: 17,9÷39,1 kW Compact-Y EXP Range

Cooling capacity: 42,6÷61,9 kW P.80

TXAEY 117÷133

Heating capacity: 47,8÷67,9 kW Compact-Y EXP Range

Hermetic Scroll compressors

Hermetic Scroll compressors GREEN LINE

Cooling capacity: 70,4÷307 kW

Heating capacity: 71,4÷340 kW Q-Pack EXP Range

GREEN LINE

Cooling capacity: 262-389 kW P.84

TXAE 475÷4315

Heating capacity: 409÷700 kW Z-Power Range EXP

P.86

TXAVZ 2400÷2680

Hermetic Scroll compressors

Semi-hermetic screw compressors GREEN LINE

Cooling capacity: 5.5-249 kW

P. 82

TXAEY 245÷265

Heating capacity: 6,5÷14,5 kW Comby-Flow EXP Range

GREEN LINE

Cooling capacity: 411÷850 kW P.88

TXHEY 105-112

Heating capacity: 462÷953 kW Z-Flow Range EXP

P.90

TXHVZ 2390÷2800

Hermetic Scroll compressors

Semi-hermetic screw compressors GREEN LINE

GREEN LINE

Condensing units Cooling capacity: 5,1÷26,3 kW

Heating capacity: 6÷29,9 kW

MCAE-MHAE 105÷127

Cooling capacity: 30.5-181.1 kW P.92

Hermetic rotary blade and Scroll compressors

MCAE 131÷2181

P.94

Cooling towers

P.98

Hermetic Scroll compressors

SYSTEM ACCESSORIES Remote condensers

P.96

CCAM 105÷2130

CEHV CEHP 46÷2791

Axial fans

Axial fans

Cooling capacity: 50.2-249 kW Pumping groups

P.100

AS 0300÷2500

RHOSS SEQUENCER

Water chiller management software

Pumping groups

P.102

PBHI 0200-0400

P. 104

RHOSS SUPERVISOR

RHOSS supervision software

P. 105

Cooling capacity: 7,2÷20,5 kW P.120

Ductable fan coil units for recessed horizontal or vertical installation. Nominal air flow: 275÷940 m/h

Heating capacity: 3,2÷23,8 kW

UTNC-EV

Cooling capacity: 2,5÷7,8 kW P.124

Cooling capacity: 7.2-108 kW P.128

Ductable terminal air handling units in sections Air flow rate: 1.100÷1.680 m⁄h

Heating capacity: 11.3-174 kW

UTNA

P. 130

Ductable terminal air handling units in sections Air flow rate: 1,800-16,500 m/h

CONTROLS for fan coil units and terminal units

Recovery capacity: 5.4-18.6 kW

UTNR

P.126

Cassette-type fan coil units

Heating capacity: 10,3÷23 kW

UTNB

Heating capacity: 3,7÷18,7 kW

VTNC

Cassette-type fan coil units

Cooling capacity: 4,1÷10,5 kW

P.122

Ductable fan coil unit for recessed horizontal or vertical installation. Air flow rate: 1.550÷3.875 m/h

P.132

P. 108

iDRHOSS

Integrated solutions for system management

SYSTEM ACCESSORIES

Air renewal terminal units with heat recovery Air flow rate: 1.200÷4.000 m/h

P. 106

SELECTION SOFTWARE for Chillers - Fan-coils

P. 18

FAN COIL UNITS

Cooling capacity: 2,4÷9,8 kW

Heating capacity: 9,6÷32,8 kW

YardyHP

AIR cooled AXIAL fans AIR cooled CENTRIFUGAL fans

Heating capacity: 2,4÷12 kW

YardyDUCT

P.118

Recessed or false ceiling fan coil units

WATER cooled CONDENSERLESS UNITS

YardyEV

Floor and ceiling fan coil units

Cooling capacity: 2÷5,1 kW

Heating capacity: 1,4÷17,4 kW

WATER CHILLERS HEAT PUMPS

Cooling capacity: 1÷7,2 kW P.116

WATER CHILLERS HEAT PUMPS

Heating capacity: 1,4÷17,4 kW

YardyEV

P. 112

Floor and ceiling fan coil units

INDUSTRIAL & PROCESS COOLING

BrioEV

Hi-wall fan coil

Cooling capacity: 1÷7,2 kW

Heating capacity: 1,3÷16,5 kW

TERMINAL UNITS

IDROWALL

Cooling capacity: 1÷6,9 kW P. 110

EXP Polyvalent systems

Heating capacity: 2,5÷5,4 kW

CONDENSING UNITS

FAN COIL UNITS - TERMINAL UNITS Cooling capacity: 1,9÷3,9 kW

WATER CHILLERS HEAT PUMPS

17

Chillers and Fan-coils 18

SELECTION SOFTWARE

• SIMPLE to install and use • FLEXIBLE when selecting RHOSS units in work conditions • EFFECTIVE and EXHAUSTIVE results for the designer

• Their extreme ease of use and great flexibility make Rhoss Chiller Selection and Rhoss Fan-coils Selection two indispensable tools for users in the sector. • The possibility to check performances in conditions other than standard, to print and export highly

detailed technical reports in PDF and WORD format, complete with commercial descriptions and support in 5 languages, make selection a simple, quick and precise process.

iDRHOSS Integrated solutions for system management PAG. 108

RHOSS SUPERVISOR Rhoss supervision software PAG. 107

RHOSS SEQUENCER Software for managing chillers PAG. 106

SELECTION SOFTWARE for Chillers - Fan-coils

19

Low consumption Mini-Y range 20

TCAEY 105÷111

GREEN LINE

Cooling capacity: 5.5÷11.1 kW

• Compact and Plug&Play units

Packaged air cooled water chillers with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.

FACTORY FITTED ACCESSORIES

Construction features

Option with iDRHOSS control

• Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins or coil with aluminium micro-channel pipes, complete with protection grille. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: microprocessor electronic control available in 2 versions: standard, with Adaptive Function logic, and iDRHOSS compatible, with Adaptive Function Plus logic • Structure: in galvanised and painted sheet steel.

• Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

Models

Option with iDRHOSS control

• TCAEY: unit designed for cooling only.

• Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

PUMP unit • Pumping group complete with: circulator pump, expansion tank with membrane, manual air bleed valve, safety valve.

TANK&PUMP unit • Pumping group complete with: water buffer tank, circulator pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve.

• Soft-start device (for models with power supply 230 V). • -10°C condensation control. • Low pressure switch.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • -10°C condensation control. • Water filter • Low pressure switch. • Antifreeze electric heater on the buffer tank. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management.

2,74

2,58

2,66

2,62 / 2,62

O E.S.E.E.R.

3,15

2,77

3,16

3,11 / 3,15

- E.S.E.E.R.+

3,50

3,07

3,50

3,42 / 3,49 4,12 / 4,25

… Absorbed power (*)

kW

2,00

2,67

3,32

† Cooling capacity (radiating)

kW

7,5

9,3

12,2

15,2 / 15,5

3,71

3,54

3,56

3,54 / 3,54 4,30 / 4,39

kW

2,02

2,61

3,43

‡ Sound pressure level

dB(A)

46

47

47

47

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

Circuits

No.

1

1

1

1

l

19

19

30

30

… Circulator pump available static pressure Main supply

kPa

55 / 85

55 / 86

65 / 84

61 /75

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

DIMENSIONS AND WEIGHTS

400-3+N-50

400-3+N-50

400-3+N-50

105

107

109

111

W - Width

mm

990

990

990

990

H - Height PUMP

mm

905

905

1.085

1.085

H - Height TANK & PUMP

mm

905

905

1.295

1.295

D - Depth

mm

380

380

380

380

ˆ Weight

kg

131

133

157

166

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 35°C - Water: 18/23°C. ‡ At 5 m from the unit in free field (Q = 2). ˆ The weight refers to the unit in its most complete form.

O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) Unit without circulator pump.

EXP Polyvalent systems

Water tank content

CONDENSING UNITS

† Absorbed power (radiating) (*)

SYSTEM ACCESSORIES

† E.E.R. (radiating)

AIR cooled AXIAL fans

… E.E.R.

AIR cooled CENTRIFUGAL fans

10,8 / 11,1

WATER cooled CONDENSERLESS UNITS

111

8,8

WATER CHILLERS HEAT PUMPS

109

6,9

WATER CHILLERS HEAT PUMPS

107

5,5

kW

INDUSTRIAL & PROCESS COOLING

105

… Nominal cooling capacity

FAN COIL UNITS

TCAEY MODEL

WATER CHILLERS HEAT PUMPS

21

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Low consumption Mini-Y NF range 22

THAEY 105÷111 NF

GREEN LINE

Cooling capacity: 5.5÷11.1 kW - Heating capacity: 5.8÷11.9 kW

• Compact and Plug&Play units • Operation with outdoor air down to –15°C

Packaged air-cooled reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.

TANK&PUMP unit

Construction features

FACTORY FITTED ACCESSORIES

• Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins with hydrophilic treatment, complete with protection grille. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. • Structure: in galvanised and painted sheet steel, complete with condensation drain pan and unit base antifreeze electric heater.

• Soft-start device (for models with 230 V power supply). • Crankcase heater compressor. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

Models • THAEY: heat pump unit.

PUMP unit • Pumping group complete with: circulator pump, expansion tank with membrane, manual air bleed valve, safety valve.

• Pumping group complete with: water buffer tank, circulator pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve.

ACCESSORIES SUPPLIED LOOSE • 3-way valve for the production of hot water. • Additional electric heater for heat pump, managed by regulation. • External air temperature probe for set-point compensation. • Antivibration rubber mountings. • Water filter • Antifreeze electric heater on the buffer tank. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

2,51/2,60

2,80

3,43

4,60/4,59

†Cooling capacity

kW

5,50

6,90

8,80

10,8/11,1

†E.E.R.

2,74

2,58

2,66

2,62/2,62

O E.S.E.E.R.

3,15

2,77

3,16

3,11/3,15

- E.S.E.E.R.+

3,50

3,07

3,50

3,42/3,49

†Absorbed power (*)

kW

2,00

2,67

3,32

4,12/4,25

‡Heating capacity

kW

5,95

7,76

9,54

12,06/12,47

‡Absorbed power

kW

1,75

2,16

2,78

3,47/3,47

3,40

3,59

3,43

3,48/3,59

‡C.O.P. (**) ˆHeating capacity

kW

3,61

4,66

5,93

7,46/7,44

ˆAbsorbed power

kW

1,72

2,20

2,82

3,50/3,52

2,10

2,12

2,10

2,13/2,11

7,50

8,90

12,10

14,5/14,8

3,71

3,27

3,53

3,20/3,27 72

ˆC.O.P. ‰Cooling capacity

kW

‰E.E.R. ‡Sound power level

dB(A)

70

72

72

†/Š Sound pressure level

dB(A)

46

47

47

47

No.

1/1

1/1

1/1

1/1

Scroll/step compressor Water buffer tank content †Circulator pump available static pressure Main supply

l

19

19

30

30

kPa

55

55

65/84

61/75

V-ph-Hz

230-1-50

230-1-50 / 400-3+N-50

230-1-50 / 400-3+N-50

230-1-50 / 400-3+N-50

105

107

109

111

DIMENSIONS AND WEIGHTS W - Width

mm

990

990

990

990

H - Height PUMP

mm

905

905

1.085

1.085

H - Height TANK&PUMP

mm

905

905

1.295

1.295

D - Depth

mm

380

380

380

380

‹ Weight

kg

141

143

167

176

In the following conditions: … Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. †Air: 35°C - Water: 7/12°C. ‡ Air: 7°C D.B. - 6°C W.B. - Water: 35/30°C. ˆ Air : -7°C D.B. - Water : 35. Same water flow as in condition ‡. ‰Air: 35°C - Water: 18/23°C. Š At 5 m from the unit, in free field (Q = 2). ‹ The weight refers to the unit in its most complete form.

O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) Unit without circulator pump. (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511).

AIR cooled AXIAL fans

2,76

2,13

AIR cooled CENTRIFUGAL fans

2,65

kW

WATER cooled CONDENSERLESS UNITS

2,74

… Absorbed power (*)

WATER CHILLERS HEAT PUMPS

111 11,52/11,97

WATER CHILLERS HEAT PUMPS

109 9,46

INDUSTRIAL & PROCESS COOLING

107 7,43

EXP Polyvalent systems

… C.O.P.

105 5,80

CONDENSING UNITS

kW

SYSTEM ACCESSORIES

… Heating capacity

FAN COIL UNITS

THAEY NF MODEL

WATER CHILLERS HEAT PUMPS

23

OUTDOOR INSTALLATION

TERMINAL UNITS

HEAT PUMP

Low consumption Compact-Y range 24

TCAEY-THAEY 115÷238

GREEN LINE

Cooling capacity: 15.4÷38.8 kW - Heating capacity: 16.8÷41.7 kW

• ESEER with Adaptive Function Plus up to 4.1

Packaged air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater for mod. 127÷238. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: microprocessor electronic control available in 2 versions: standard, with Adaptive Function logic, and iDRHOSS compatible, with Adaptive Function Plus logic. • Structure: in galvanised and painted sheet steel, complete with condensation drain pan.

FACTORY FITTED ACCESSORIES • Soft-start device. • Silenced configuration. • -10°C condensation control. • Antifreeze electric heater on the buffer tank. • Crankcase heater compressor (mod. 115÷124). • Unit base antifreeze electric heater for operation in heat pump mode at low external air temperatures (mod.115÷130). • Protection coil grilles. • Desuperheater 15% (mod. 133-233). • 100% heat recovery (mod. 133-233). • Pump with increased head pressure (mod. 133÷238) or circulator with low head pressure (mod. 115÷233). • Pump with increased head pressure (mod. 133÷238) or circulator with low head pressure (mod. 115-÷233) + buffer tank.

Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE Models • TCAEY: unit designed for cooling only. • THAEY: heat pump unit.

STANDARD unit (for mod. 133÷238 only) • Without pumping group and buffer tank.

PUMP unit • Pumping group complete with: circulator, expansion tank with membrane, manual air bleed valve, safety valve.

• Protection coil grilles. • Antivibration rubber mountings. • -10°C condensation control. • Water filter • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management.

Option with control TANK & PUMP unit • Pumping group complete with: water buffer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve and pressure gauge.

• 3-way valve for the production of hot water (mod. 115-133). • External air temperature probe for set-point compensation. • Additional electric heater for heat pump, managed by regulation. • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

238 38,8

… E.E.R.

2,76

2,67

2,76

2,62

2,59

2,44

2,56

2,64

3,06

O E.S.E.E.R.

3,15

3,11

3,44

3,09

3,18

2,89

2,85

3,67

3,69

- E.S.E.E.R.+

3,49

3,42

3,82

3,41

3,50

3,20

3,19

4,11

4,12

… Absorbed power (*)

kW

5,6

6,5

8,2

9,3

10,4

11,9

13,3

12,3

12,7

† Nominal heating capacity

kW

16,8

17,9

23,9

26,1

30,7

34,4

39,1

37,5

41,7

3,05

2,94

3,02

2,92

3,07

3,10

2,94

3,05

3,26

5,5

6,1

7,9

8,9

10,0

11,1

13,3

12,3

12,8

E.E.R. (EN 14511:2004) (***)















3,33

4,03

C.O.P. (EN 14511:2004) (***)















4,00

4,26

3,74

3,77

3,93

3,76

3,94

3,86

3,67

3,96

4,16 54

†C.O.P. † Absorbed power (*)

kW

C.O.P. (**) ‡ Sound pressure level

dB(A)

50

50

52

52

53

53

54

54

‡ Silenced version sound pressure level

dB(A)

46

46

49

49

50

50

51

51

51

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

1/1

1/1

1/1

2/2

2/2

Circuits

No.

1

1

1

1

1

1

1

1

1

l

35

35

45

45

45

45

80

80

150

… Available nominal head pressure of circulator pump/standard pump kPa

74/147

63/130

64/130

66/125

61/110

57/105

65/134

69/134

130

Water tank content Main supply

V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50

DIMENSIONS AND WEIGHTS

115

117

122

124

127

130

133

233

238

W - Width STANDARD

mm













1.660

1.660

2.260

W - Width PUMP

mm

1.230

1.230

1.230

1.230

1.535

1.535

1.660

1.660

2.260

W - Width TANK & PUMP

mm

1.522

1.522

1.522

1.522

1.822

1.822

1.660

1.660

2.260

H - Height

mm

1.090

1.090

1.280

1.280

1.510

1.510

1.570

1.570

1.570

D - Depth

mm

580

580

600

600

695

695

1.000

1.000

1.000

ˆ Weight TCAEY

kg

210

220

270

280

310

370

450

465

625

ˆ Weight THAEY

kg

215

225

278

288

320

380

460

475

645

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ‡ At 5 m from the unit in free field (Q = 2). ˆ The weight refers to the unit in its most complete form. O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software.

(*) Unit without pump (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511). (***) Energy ratings for versions with a standard pump, calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market.

AIR cooled AXIAL fans

233 32,5

AIR cooled CENTRIFUGAL fans

133 34,0

WATER cooled CONDENSERLESS UNITS

130 29,1

WATER CHILLERS HEAT PUMPS

127 26,9

WATER CHILLERS HEAT PUMPS

124 24,3

INDUSTRIAL & PROCESS COOLING

122 22,7

EXP Polyvalent systems

117 17,4

CONDENSING UNITS

115 15,4

kW

SYSTEM ACCESSORIES

TCAEY-THAEY MODEL … Nominal cooling capacity

WATER CHILLERS HEAT PUMPS

25

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Low consumption Compact-Y range 26

TCAEY-THAEY 118÷136 H.E.

GREEN LINE

Cooling capacity: 13.4÷27.8 kW - Heating capacity: 15.6÷31.7 kW

• Hydraulic unit for radiant applications • ESEER with Adaptive Function Plus up to 3.9

High energy efficiency packaged air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. • Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THAEY.

Models • TCAEY: unit designed for cooling only. • THAEY: heat pump unit.

PUMP unit • Pumping group complete with: circulator, expansion tank with membrane, manual air bleed valve, safety valve.

TANK & PUMP unit • With tank and pump. • With tank, pump and water bypass between primary and secondary circuit . Pumping group complete with: circulation pump and water buffer tank or circulation pump, water buffer tank and water bypass

which disconnects the primary from the secondary water circuit, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve and pressure gauge.

FACTORY FITTED ACCESSORIES • Circulator pump with low static pressure. • Circulator pump with low static pressure + water buffer tank. • Circulator pump with low static pressure + water buffer tank + delivery and return pipe bypass. • Soft-start device. • Silenced configuration. • Antifreeze electric heater on the buffer tank. • Protection coil grilles • Unit base antifreeze electric heater for operation in heat pump mode at low external air temperatures. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • 3-way valve for the production of hot water. • External air temperature probe for set-point compensation. • Additional electric heater for heat pump, managed by regulation. • Protection coil grilles • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

3,52

3,56

3,51

3,54

3,58

3,53

… Absorbed power (radiating) (*)

kW

5,10

5,78

7,00

8,13

8,78

11,46

† Nominal heating capacity (radiating)

kW

16,1

17,7

20,7

24,5

28,4

33,5

†C.O.P.(radiating)

4,28

4,23

4,25

4,12

4,12

4,10

† C.O.P. (**)

3,96

3,95

4,04

3,98

3,93

3,96

† Absorbed power (radiating) (*)

kW

3,75

4,18

4,87

5,94

6,90

8,18

‡ Cooling capacity

kW

13,4

15,5

18,7

22,6

24,3

27,8

‡ E.E.R.

2,70

2,92

2,97

2,97

2,96

2,74

O E.S.E.E.R.

3,48

3,51

3,45

3,42

3,58

3,31

- E.S.E.E.R.+

3,86

3,89

3,80

3,78

3,94

3,67

‡ Absorbed power (*)

kW

4,95

5,33

6,30

7,61

8,20

10,12

ˆ Heating capacity

kW

15,6

16,1

20,3

23,8

27,7

31,7

3,14

3,09

3,32

3,19

3,20

3,13

kW

4,97

5,23

6,10

7,48

8,63

10,12

‰ Sound pressure level

dB(A)

48

50

52

52

53

53

‰ Silenced version sound pressure level

dB(A)

44

46

49

49

50

50

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

1/1

1/1

Circuits

No.

1

1

1

1

1

1

l

35

35

45

45

45

45

ˆ C.O.P. ˆ Absorbed power (*)

Water tank content

… Available nominal head pressure of circulator pump/pump kPa

63/129

45/108

55/116

45/98

42/95

47/81

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

118

120

125

129

132

136

W - Width PUMP

mm

1.230

1.230

1.230

1.230

1.535

1.535

W - Width TANK & PUMP

mm

1.522

1.522

1.522

1.522

1.822

1.822

H - Height

mm

1.090

1.090

1.280

1.280

1.510

1.510

D - Depth

mm

580

580

600

600

695

695

ž Weight TCAEY

kg

210

220

270

280

310

370

ž Weight THAEY

kg

215

225

278

288

320

380

Main supply DIMENSIONS AND WEIGHTS

In the following conditions: … Air: 35°C - Water: 18/23°C. † Air: 7°C D.B. - 6°C W.B. - Water: 35/30°C. ‡ Air: 35°C - Water: 7/12°C ˆ Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ‰ At 5 m from the unit, in free field (Q = 2).

O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) Unit without pump. (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511).

AIR cooled AXIAL fans

136 40,5

AIR cooled CENTRIFUGAL fans

132 31,5

WATER cooled CONDENSERLESS UNITS

129 28,8

WATER CHILLERS HEAT PUMPS

125 24,6

WATER CHILLERS HEAT PUMPS

120 20,6

INDUSTRIAL & PROCESS COOLING

… E.E.R. (radiating)

118 18,0

EXP Polyvalent systems

kW

CONDENSING UNITS

… Nominal cooling capacity (radiating)

SYSTEM ACCESSORIES

TCAEY-THAEY H.E. MODEL

WATER CHILLERS HEAT PUMPS

27

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Low consumption Compact-Y range 28

TCAEY-THAEY 245÷265

GREEN LINE

Cooling capacity: 44.2÷64 kW - Heating capacity: 47.8÷67.9 kW

• 3 capacity steps • ESEER with Adaptive Function Plus up to 5

Packaged air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 3 capacity steps with high efficiency at partial loads. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. • Structure: in galvanised and painted sheet steel.

Models • TCAEY: unit designed for cooling only. • THAEY: heat pump unit.

FACTORY FITTED ACCESSORIES • PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with water buffer tank and single or double pump,

including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • Soft-start device. • Silenced configuration. • 15% desuperheater. • 100% heat recovery. • Refrigerant circuit high and low pressure gauges. • Protection coil grilles. • Antifreeze electric heater for buffer tank and pumps. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • External air temperature probe for set-point compensation. • Additional electric heater for heat pump, managed by regulation. • Protection coil grilles • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

2,67

4,38

4,03

- E.S.E.E.R.+

4,38

4,98

5,04

4,72

… Absorbed power (*)

kW

17,4

19,7

22,1

24,0

† Nominal heating capacity

kW

47,8

55,8

62,2

67,9

2,89

3,00

3,04

2,91

16,6

18,6

20,5

23,3

E.E.R. (EN 14511:2004) (***)

3,36

3,34

3,39

3,44

C.O.P. (EN 14511:2004) (**) (***)

3,93

3,94

3,93

3,97 57

†C.O.P. † Absorbed power (*)

kW

‡ Sound pressure level

dB(A)

56

56

57

‡ Silenced version sound pressure level

dB(A)

53

53

54

54

No.

2/3

2/3

2/3

2/3

Scroll/step compressor Circuits

No.

1

1

1

1

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

245

250

260

265

mm

2.260

2.260

2.260

2.260

H - Height

mm

1.570

1.570

1.570

1.570

D - Depth

mm

1.000

1.000

1.000

1.000

ˆ Weight TCAEY

kg

725

750

775

820

ˆ THAEY weight

kg

745

770

795

840

245

250

260

265

l/h

7.600

8.800

10.200

11.000

l

150

150

150

150

Pump P1

KPa

113

103

88

75

Pump P2

KPa

186

179

169

150

245

250

260

265

l/h

7.600

8.800

10.200

11.000

Pump P1

KPa

122

114

102

92

Pump P2

KPa

195

190

184

167

Main supply DIMENSIONS AND WEIGHTS W - Width

TANK & PUMP TCAEY-THAEY MODEL Nominal flow Water tank content Pump available head pressure

PUMP TCAEY-THAEY MODEL Nominal flow Pump available head pressure

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ‡ At 5 m from the unit in free field (Q = 2). ˆ The weight refers to the unit in its most complete form. O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) Unit without pump. (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511). (***) Energy ratings calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market.

AIR cooled AXIAL fans

2,68

4,31

AIR cooled CENTRIFUGAL fans

2,60

3,78

WATER cooled CONDENSERLESS UNITS

2,55

O E.S.E.E.R.

WATER CHILLERS HEAT PUMPS

… E.E.R.

WATER CHILLERS HEAT PUMPS

265 64,0

INDUSTRIAL & PROCESS COOLING

260 59,2

EXP Polyvalent systems

250 51,3

kW

CONDENSING UNITS

245 44,2

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCAEY-THAEY MODEL

WATER CHILLERS HEAT PUMPS

29

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Y-M.I.C.H. Range 30

GREEN LINE

TCAIY-THAIY 124-150 Cooling capacity: 23.8÷48.5 kW - Heating capacity: 27.3÷54.3 kW

• Modulating cooling capacity range: 30-100% • ESEER > 3.9

Packaged air-cooled reversible water chillers and heat pumps with axial fans. Range with hermetic Scroll compressors, inverters and R410A refrigerant gas. Construction features • Compressor:hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater, activated by Inverter. • Expansion valve: electronic. • Water side heat exchanger: stainless steel plate exchanger closed cell polyurethane foam rubber insulation, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control, iDRHOSS compatible • Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THAIY 124.

Models • TCAIY: unit designed for cooling only. • THAIY: heat pump unit.

STANDARD unit • Without pumping group and buffer tank (for model 150 only).

PUMP unit • With pump. • With pump and pump in standby (model 150 only). Pumping group complete with: single or double circulation pump, including one standby pump that is automatically activated in the event of an alarm (model 150 only), expansion tank with membrane, manual air bleed valve, safety valve, water drain tap and pressure gauge. The pumps are available in the low and high pressure versions (mod. 150).

TANK & PUMP unit • With tank and pump. • With tank, pump and pump in stand-by (for model 150 only). Pumping group complete with: water buffer tank, single or double circulation pump, including one in stand-by with automatic activation in case of an alarm (for model 150 only), expansion tank with membrane, manual air bleed valve, safety valve, water drain tap, pressure gauge. The pumps are available in the low and high pressure versions (mod. 150).

FACTORY FITTED ACCESSORIES • Buffer tank and/or pumps antifreeze electric heater • Unit base antifreeze electric heater for operation in heat pump mode at low external air temperatures (mod.124). • Protection coil grilles • Refrigerant circuit high and low pressure gauges (mod. 150). • Digital input for double set-point. • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • 3-way valve for the production of hot water. • Protection coil grilles • Additional electric heater for heat pump, not managed by regulation. • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

9,42

18,4

† Nominal heating capacity

kW

27,3

54,3

†C.O.P.

2,95

3,13

9,28

17,40

E.E.R. (EN 14511:2004) (***)



3,04

C.O.P. (EN 14511:2004) (***)



3,64

3,36

3,64

† Absorbed power (*)

kW

C.O.P. (**) ‡ Sound pressure level

dB(A)

52

55

l

45

150

… Available nominal head pressure of pump

kPa

129

114

Inverter scroll compressor

No.

1

1

30-100%

30-100%

Water tank content

Modulating cooling capacity range Circuits

No.

1

1

V-ph-Hz

400-3+N-50

400-3+N-50

124

150

mm

1.522

2.260

H - Height

mm

1.280

1.570

D - Depth

mm

600

1.000

Weight TCAIY

kg

330

625

Weight THAIY

kg

338

645

Main supply DIMENSIONS AND WEIGHTS W - Width

In the following conditions: … Air: 35°C - Water: 7°/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 45°/40°C. ‡ At 5 m from the unit in free field (Q = 2). O ESEER (European Seasonal EER) - Average European seasonal efficiency.

(*) Unit without pump. (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511). (***) Energy ratings calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market.

AIR cooled AXIAL fans AIR cooled CENTRIFUGAL fans

kW

WATER cooled CONDENSERLESS UNITS

4,11

… Absorbed power (*)

WATER CHILLERS HEAT PUMPS

2,63

3,96

WATER CHILLERS HEAT PUMPS

2,53

O E.S.E.E.R.

INDUSTRIAL & PROCESS COOLING

… E.E.R.

EXP Polyvalent systems

150 48,5

kW

CONDENSING UNITS

124 23,8

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCAIY - THAIY MODEL

WATER CHILLERS HEAT PUMPS

31

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Low consumption Y-Pack range 32

TCAEY-THAEY 270÷2160

GREEN LINE

Cooling capacity: 67÷161 kW - Heating capacity: 79÷175 kW

• 3 capacity steps • ESEER up to 4.37 • Wide range of accessories

TCAEQY 270

THAESY 2145

TCAEBY 2160

Packaged air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • 2 or 3 capacity steps depending on the models with high efficiency at partial loads. • Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (TCAEBY excluded). • Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. • The unit is also complete with: - compressor and fan thermal overload switches.

Versions • B - Standard version (TCAEBY). • T - High temperature/efficiency version with larger coil surface (TCAETY-THAETY). • S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TCAESYTHAESY). • Q - Supersilenced version complete with soundproofed compressor compartment, super-low fan speed and larger coil surface (TCAEQY).

Models • TCAEBY: standard unit designed for cooling only. • TCAETY: high temperature/efficiency unit designed for cooling only. • TCAESY: silenced unit designed for cooling only. • TCAEQY: supersilenced unit designed for cooling only. • THAETY: heat pump unit. • THAESY: silenced heat pump unit.

FACTORY FITTED ACCESSORIES • PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water side pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with built-in buffer tank from 250 to 450 litres and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Electronic expansion valve • -10°C condensation control (TCAEBY only). • Power factor correction capacitors (cosφ > 0.91). • Soft starter. • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Evaporator antifreeze heater, buffer tank, pumps and heat exchangers for heat recovery if present. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management. • Rhoss sequencer for the integrated management of several water chillers.

2145

2160

120,5

138,5

155,0

2,65

2,69

2,56

2,69

2,72

2,64

2,66

2,61

25,5

28,0

32,4

35,7

40,6

45,6

52,1

59,4

270

280

290

2100

2115

2130

2145

2160 161,0

… Nominal cooling capacity

kW

70,3

79,5

88,0

101,2

114,5

126,0

143,0

… Nominal cooling capacity

kW

70,3

79,5

88,0

101,2

108,0

119,0

136,0

151,0

… Nominal cooling capacity

kW

67,0

75,0

82,5

95,0

101,0

108,0

125,0

138,0

… E.E.R.

2,98

2,99

2,90

2,90

2,93

2,91

2,90

2,90

… E.E.R.

2,98

2,99

2,90

2,90

2,67

2,67

2,63

2,60

… E.E.R.

2,70

2,85

2,62

2,73

2,34

2,30

2,32

2,20

O E.S.E.E.R.

4,32

4,37

4,35

4,32

4,37

4,31

4,29

4,26

- E.S.E.E.R.+

4,99

5,06

5,04

4,99

5,07

4,96

4,94

4,91

… Absorbed power

kW

23,6

26,6

30,3

34,9

39,1

43,3

49,3

55,5

… Absorbed power

kW

23,6

26,6

30,3

34,9

40,4

44,6

51,7

58,1

… Absorbed power

kW

24,8

26,3

31,5

34,8

43,2

47,0

53,9

62,7

270

280

290

2100

2115

2130

2145

2160

THAETY-THAESY MODEL † Nominal heating capacity

kW

79,0

86,0

96,0

111,0

122,0

139,0

157,0

175,0

† Nominal heating capacity

kW

79,0

86,0

96,0

111,0

120,0

135,0

154,0

170,0

†C.O.P.

3,36

3,44

3,29

3,34

3,21

3,31

3,22

3,21

†C.O.P.

3,36

3,44

3,29

3,34

3,22

3,31

3,25

3,21

kW

69,4

77,7

85,2

99,3

111,0

123,8

141,3

159,8

… Nominal cooling capacity

kW

69,4

77,7

85,2

99,3

107,2

118,5

135,6

150,2

† Absorbed power

kW

23,5

25,0

29,2

33,2

38,0

42,0

48,8

54,5

† Absorbed power

kW

23,5

25,0

29,2

33,2

37,3

40,8

47,4

53,0

E.E.R. (EN 14511:2004) (***)

3,44

3,49

3,30

3,32

3,34

3,33

3,30

3,29

C.O.P. (EN 14511:2004) (***)

4,26

4,34

4,17

4,22

4,04

4,14

4,01

4,02

TCAEY-THAEY MODEL

270

280

290

2100

2115

2130

2145

2160

… Nominal cooling capacity

‡ Sound pressure level TCAEBY

dB(A)

60

60

60

62

68

68

68

69

‡ Sound pressure level TCAETY-THAETY

dB(A)

55

56

56

57

60

60

62

62

‡ Sound pressure level TCAESY-THAESY

dB(A)

53

54

54

55

57

57

58

58

‡ Sound pressure level TCAEQY

dB(A)

51

52

52

53

54

54

55

55

ˆ Sound power level TCAEBY

dB(A)

82

82

82

84

90

90

90

91

ˆ Sound power level TCAETY-THAETY

dB(A)

76

77

77

78

84

84

85

85

ˆ Sound power level TCAESY-THAESY

dB(A)

74

75

75

76

81

81

82

82

ˆ Sound power level TCAEQY

dB(A)

72

73

73

74

78

78

79

79

No.

2/3

2/2

2/3

2/3

2/3

2/2

2/3

2/2

Scroll/step compressor

No.

1

1

1

1

1

1

1

1

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-500

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

270

280

290

2100

2115

2130

2145

2160

W - Width version B

mm

2.650

2.650

2.650

3.150

3.150

3.150

3.150

3.450

W - Width version T - S - Q

mm

3.150

3.150

3.150

3.150

3.250

3.250

3.250

3.250

H - Height version B

mm

1.700

1.700

1.700

1.700

1.730

1.730

1.730

1.730

H - Height version T - S - Q

mm

1.520

1.520

1.520

1.520

2.000

2.000

2.000

2.000

D - Depth version B

mm

1.210

1.210

1.210

1.210

1.210

1.210

1.210

1.210

D - Depth version T - S - Q

mm

1.210

1.210

1.210

1.210

1.520

1.520

1.520

1.520

‰ Weight TCAEBY

kg

685

725

870

945

1.020

1.040

1.100

1.160

‰ Weight TCAETY-TCAESY-TCAEQY

kg

745

765

910

980

1.130

1.195

1.225

1.290

‰ Weight THAETY-THAESY

kg

810

830

975

1045

1.215

1.285

1.315

1.390

Circuits Main supply DIMENSIONS AND WEIGHTS

In the following conditions: … Air: 35°C - Water: 7/12°C † Air: 7°C D.B. - 6°C W.B.- Water: 40/45°C. ‡ At 5 m from the unit, coil side, in free field (Q = 2). ˆ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Weight refers to the non-accessorised unit when empty. O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (***) Energy ratings for THAETY versions, calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market. Q TCAESY-THAESY silenced versions. Q TCAEQY supersilenced versions.

AIR cooled AXIAL fans

2130

110,5

AIR cooled CENTRIFUGAL fans

2115

96,0

WATER cooled CONDENSERLESS UNITS

TCAETY-TCAESY-TCAEQY MODEL

2100

WATER CHILLERS HEAT PUMPS

kW

290 83,0

WATER CHILLERS HEAT PUMPS

… Absorbed power

280 75,3

INDUSTRIAL & PROCESS COOLING

… E.E.R.

270 67,5

EXP Polyvalent systems

kW

CONDENSING UNITS

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCAEBY MODEL

WATER CHILLERS HEAT PUMPS

33

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Low consumption Y-Pack range 34

TCAEY-THAEY 4160÷4320

GREEN LINE

Cooling capacity: 138÷325 kW - Heating capacity: 160÷342 kW

• ESEER up to 4.25 • Plug&Play range • Compact version B for replacement markets

TCAETY 4320 with coil protection grille accessory TCAEBY 4200 with the silenced configuration accessory

Packaged air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.

• TCAESY: silenced unit designed for cooling only. • TCAEQY: supersilenced unit designed for cooling only. • THAETY: heat pump unit. • THAESY: silenced heat pump unit.

Construction features

FACTORY FITTED ACCESSORIES

• Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • 4 capacity steps with high efficiency at partial loads. • Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. • The unit is also complete with: - compressor and fan thermal overload switches.

• PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP with 750-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater (TCAEBY excluded). • 100% heat recovery (TCAEBY excluded). • Electronic expansion valve • -10°C condensation control. • Power factor correction capacitors (cosφ > 0.91). • Soft starter. • Silenced configuration (TCAEBY only). • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Evaporator antifreeze heater, buffer tank, pumps and heat exchangers for heat recovery if present. • Serial interface for connection with external BMS.

Versions • B - Standard version (TCAEBY). • T - High temperature/efficiency version with larger coil surface (TCAETY-THAETY). • S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TCAESYTHAESY). • Q - Supersilenced version complete with soundproofed compressor compartment, super-low fan speed and larger coil surface (TCAEQY).

Models • TCAEBY: standard unit designed for cooling only. • TCAETY: high temperature/efficiency unit designed for cooling only.

ACCESSORIES SUPPLIED LOOSE • Antivibration mountings. • Remote keyboard with display. • Clock card • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management. • Rhoss sequencer for the integrated management of several water chillers.

4320

282,0

315,0

2,57

2,51

2,51

2,53

2,51

2,52

2,55

59,1

67,7

76,1

86,6

97,2

111,9

123,9

4160

4180

4200

4230

4260

4290

4320

… Nominal cooling capacity

kW

160,0

182,0

201,0

225,0

257,0

293,0

325,0

… Nominal cooling capacity

kW

152,7

177,0

192,0

215,0

246,0

281,0

309,0

… Nominal cooling capacity

kW

138,0

164,0

181,0

211,0

228,0

259,0

-

… E.E.R.

2,87

2,80

2,75

2,75

2,79

2,77

2,70

… E.E.R.

2,74

2,70

2,60

2,60

2,75

2,61

2,55

… E.E.R.

2,24

2,45

2,25

2,45

2,35

2,25

-

O E.S.E.E.R.

4,25

4,20

4,13

4,13

4,19

4,16

4,11

TCAETY-TCAESY-TCAEQY MODEL

- E.S.E.E.R.+

4,89

4,82

4,74

4,74

4,86

4,83

4,76

… Absorbed power

kW

55,7

65,0

73,1

81,7

92,1

105,8

120,4

… Absorbed power

kW

55,9

65,6

73,8

82,7

89,5

107,7

121,2

… Absorbed power

kW

61,6

66,9

80,4

86,1

97,0

115,1

-

4160

4180

4200

4230

4260

4290

4320

THAETY-THAESY MODEL † Nominal heating capacity

kW

166,0

188,0

220,0

241,0

272,0

309,0

342,0

† Nominal heating capacity

kW

160,0

183,0

211,0

233,0

264,0

303,0

333,0

†C.O.P.

3,03

2,85

2,98

2,96

2,93

2,92

2,91

†C.O.P.

3,00

2,89

3,00

2,98

2,97

3,01

2,96

kW

158,0

179,0

197,0

222,0

253,0

289,0

320,0

… Nominal cooling capacity

kW

151,0

174,0

189,0

212,0

242,0

277,0

304,0

† Absorbed power

kW

54,8

66,0

73,8

81,4

92,8

105,8

117,5

† Absorbed power

kW

… Nominal cooling capacity

TCAEY-THAEY MODEL

53,3

63,3

70,3

78,2

88,9

100,7

112,5

4160

4180

4200

4230

4260

4290

4320

‡ Sound pressure level TCAEBY

dB(A)

66

70

70

72

72

74

74

‡ Sound pressure level TCAETY-THAETY

dB(A)

63

67

67

68

69

69

69

‡ Sound pressure level TCAESY-THAESY

dB(A)

59

61

61

62

64

64

64

‡ Sound pressure level TCAEQY

dB(A)

56

58

58

59

60

60

-

ˆ Sound power level TCAEBY

dB(A)

90

92

92

94

94

95

95

ˆ Sound power level TCAETY-THAETY

dB(A)

86

91

91

92

93

93

93

ˆ Sound power level TCAESY-THAESY

dB(A)

83

86

86

87

89

89

89

ˆ Sound power level TCAEQY

dB(A)

80

83

83

84

85

85

-

No.

4/4

4/4

4/4

4/4

4/4

4/4

4/4

Scroll/step compressor Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

4160

4180

4200

4230

4260

4290

4320

W - Width version B

mm

3.130

3.130

3.130

4.090

4.090

5.050

5.050

W - Width TCAETY-TCAESY-TCAEQY

mm

3.700

3.700

3.700

4.800

4.800

4.800

4.800

W - Width THAETY-THAESY

mm

3.700

3.700

4.800

4.800

4.800

4.800

4.800

H - Height version B

mm

2.135

2.135

2.135

2.135

2.135

2.135

2.135

H - Height version T - S

mm

2.000

2.030

2.030

2.030

2.030

2.030

2.030

H - Height version Q

mm

2.000

2.000

2.000

2.000

2.000

2.000



D - Depth version B

mm

1.190

1.190

1.190

1.190

1.190

1.190

1.190

D - Depth version T - S - Q

mm

2.090

2.090

2.090

2.090

2.090

2.090

2.090

DIMENSIONS AND WEIGHTS

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B.- Water: 40/45°C. ‡ At 5 m from the unit, coil side, in free field (Q = 2). ˆ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Weight refers to the non-accessorised unit when empty. O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. Q TCAESY-THAESY silenced versions. Q TCAEQY supersilenced versions.

AIR cooled AXIAL fans

4290

244,0

AIR cooled CENTRIFUGAL fans

4260

219,0

WATER cooled CONDENSERLESS UNITS

4230

191,0

WATER CHILLERS HEAT PUMPS

kW

4200

170,0

WATER CHILLERS HEAT PUMPS

… Absorbed power

4180

152,0

INDUSTRIAL & PROCESS COOLING

… E.E.R.

4160

EXP Polyvalent systems

kW

CONDENSING UNITS

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCAEBY MODEL

WATER CHILLERS HEAT PUMPS

35

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Y-Pack Range FREECOOLING 36

TFAEY-TGAEY 4160÷4320

GREEN LINE

Cooling capacity: 170÷361 kW

• NO GLYCOL version available • Plug&Play range • Software for estimating energy savings

TFAETY 4230 with coil protection grille accessory

Air-cooled water chillers in Freecooling mode (TFAEY) and Freecooling NO-GLYCOL mode (TGAEY) with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.

Versions

Construction features

• TFAETY: high efficiency unit in Freecooling mode. • TFAESY: silenced unit in Freecooling mode. • TGAETY: high efficiency unit in Freecooling NO-GLYCOL mode. • TGAESY: silenced unit in Freecooling NO-GLYCOL mode.

• Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • 4 capacity steps with high efficiency at partial loads. • Water side heat exchanger (evaporator): stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch (TFAEY) or flow switch (TGAEY). • Heat exchanger (water-water) in Freecooling NO-GLYCOL mode: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. • Air side heat exchanger(condenser): finned coil exchanger, with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. • The unit is also complete with: - compressor and fan thermal overload switches; - Modulating water side 3-way valve.

• T - High efficiency version(TFAETY-TGAETY). • S - Silenced version complete with soundproofed compressor compartment, lower fan speed (TFAESY-TGAESY).

Models

FACTORY FITTED ACCESSORIES • PUMP with single or double pump, including an automatic pump in standby complete with safety valve. The pumps are available in the low or high pressure versions. • Electronic expansion valve • Power factor correction capacitors (cosφ > 0.91). • Soft starter. • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Evaporator antifreeze electric heater, pumps if present. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Antivibration mountings. • Remote keyboard with display. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

… Nominal cooling capacity

kW

178

202

224

251

286

326

361

… Nominal cooling capacity

kW

170

197

215

240

274

312

344

… E.E.R.

3,3

3,4

3,3

3,2

3,3

3,2

3,1

… E.E.R.

3,2

3,3

3,1

3,1

3,2

3,1

2,9

… Absorbed power

kW

53,8

59,3

68,4

78,5

85,6

102,0

117,0

… Absorbed power

kW

53,0

59,3

69,2

77,2

85,2

100,9

117,9

† Nominal cooling capacity

kW

178

202

224

251

286

326

361

† Nominal cooling capacity

kW

170

197

215

240

274

312

344

21,3

24,4

26,9

20,5

22,8

19,5

21,5

FREE-COOLING ON 100%

33,0

37,8

41,4

31,7

35,2

30,0

32,9

† Absorbed power

kW

8

8

8

12

12

16

16

† Absorbed power

kW

5

5

5

7,5

7,5

10

10

† Total Freecooling temperature

°C

0,3

1

0,4

0,7

0,9

0,4

–0,8

† Total Freecooling temperature

°C

TFAETY-TFAESY MODEL

–1,3

–0,8

–1,5

–1,3

–1,1

–1,6

–3,0

4160

4180

4200

4230

4260

4290

4320

‡ Sound pressure level

dB(A)

65

67

67

69

69

70

70

‡ Sound pressure level

dB(A)

60

61

61

63

64

65

65

ˆ Sound power level

dB(A)

89

91

91

93

93

94

94

ˆ Sound power level

dB(A)

85

86

86

88

89

90

90

No.

4/4

4/4

4/4

4/4

4/4

4/4

4/4

Scroll/step compressor Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

DIMENSIONS AND WEIGHTS

4160

4180

4200

4230

4260

4290

4320

W - Width

mm

4.800

4.800

4.800

4.800

5.300

5.300

5.300

H - Height

mm

2.030

2.030

2.030

2.030

2.030

2.030

2.030

D - Depth

mm

2.090

2.090

2.090

2.090

2.090

2.090

2.090

Q TFAESY Silenced version.

EXAMPLE OF SOFTWARE OUTPUT FOR ESTIMATING ENERGY SAVINGS 25

Absorbed power (MWh)

In the following conditions: … Air: 30°C - Water: 10/15°C - Ethylene glycol 30%. †Water:10/15°C - Ethylene glycol 30%. ‡ At 5 m from the unit, coil side, in free field (Q = 2). ˆ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744.

20

Q Traditional chiller Q TFAEY

15 10 5 0 -20

-15

-10

-5

0

5

10

15

External air temperature

20

25

30

35

CONDENSING UNITS

† E.E.R.

SYSTEM ACCESSORIES

† E.E.R.

AIR cooled AXIAL fans

4320

AIR cooled CENTRIFUGAL fans

4290

WATER cooled CONDENSERLESS UNITS

4260

WATER CHILLERS HEAT PUMPS

4230

WATER CHILLERS HEAT PUMPS

4200

INDUSTRIAL & PROCESS COOLING

4180

EXP Polyvalent systems

4160

FREE-COOLING OFF

FAN COIL UNITS

TFAETY-TFAESY MODEL

WATER CHILLERS HEAT PUMPS

37

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Y-Power Range 38

TCAEY-THAEY 5350÷6450 Cooling capacity: 331.4÷455.1 kW - Heating capacity: 353.4÷486.2 kW

• 6 capacity steps • ESEER up to 4.35 • Simplified installation with the Tank&Pump accessory THAESY 6450 with Tank&Pump accessory

Packaged air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • 5 or 6 capacity steps with high efficiency at partial loads. • Electronic expansion valve: as standard on all models. • Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

Versions • B -Standard version (TCAEBY-THAEBY). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAESY-THAESY). • I -Soundproofed version with soundproofed compressor cover (TCAEIY-THAEIY).

Models • TCAEBY: unit designed for cooling only. • TCAESY: silenced unit designed for cooling only. • TCAEIY: soundproofed unit designed for cooling only. • THAEBY: heat pump unit. • THAESY: silenced heat pump unit. • THAEIY: soundproofed heat pump unit.

FACTORY FITTED ACCESSORIES • PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • TANK&PUMP with 1,100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Bottom compartment protection grilles. • Evaporator antifreeze heater, buffer tank and heat exchangers for heat recovery if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

354,3

397,9

446,0

… E.E.R.

2,85

2,81

2,68

2,60

… E.E.R.

2,80

2,73

2,58

2,50

O E.S.E.E.R.

4,30

4,35

4,31

4,26

O E.S.E.E.R.

4,01

4,05

4,01

3,97

121,0

130,2

153,2

175,0

… Absorbed power

kW

… Absorbed power

kW

THAEBY-THAESY MODEL

120,6

129,8

154,3

178,1

5350

6370

6410

6450

† Nominal heating capacity

kW

372,0

393,6

434,2

486,2

† Nominal heating capacity

kW

353,4

373,9

412,5

461,9

†C.O.P.

2,95

2,92

2,89

2,85

† C.O.P.

2,92

2,89

2,86

2,82

kW

338,2

357,8

402,0

446,1

… Nominal cooling capacity

kW

331,4

350,6

394,0

437,2

† Absorbed power

kW

126,0

134,7

150,2

170,9

† Absorbed power

kW

120,6

128,9

143,8

163,7

5350

6370

6410

6450

… Nominal cooling capacity

TCAEBY-TCAESY-THAEBY-THAESY MODEL ‡ Sound pressure level

dB(A)

77

77

78

78

‡ Sound pressure level

dB(A)

71

71

72

72

ˆ Sound power level

dB(A)

95

95

96

96

ˆ Sound power level

dB(A)

89

89

90

90

No.

5/5

6/6

6/6

6/6

Scroll/step compressor Circuits Main supply

No.

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

5350

6370

6410

6450

W - Width

mm

4.830

4.830

4.830

4.830

H - Height

mm

2.340

2.340

2.340

2.340

D - Depth

mm

2.260

2.260

2.260

2.260

‰ Weight TCAEBY

kg

3.300

3.450

3.500

3.520

‰ Weight THAEBY

kg

3.500

3.640

3.680

3.710

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Weight refers to the accessorised unit when empty with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

Q TCAESY-THAESY silenced versions.

AIR cooled AXIAL fans

338,2

AIR cooled CENTRIFUGAL fans

kW

WATER cooled CONDENSERLESS UNITS

455,1

… Nominal cooling capacity

WATER CHILLERS HEAT PUMPS

410,2

WATER CHILLERS HEAT PUMPS

6450

365,3

INDUSTRIAL & PROCESS COOLING

6410

345,1

EXP Polyvalent systems

6370

kW

CONDENSING UNITS

5350

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCAEBY-TCAESY MODEL

WATER CHILLERS HEAT PUMPS

39

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Z-Power Range 40

TCAVZ 1270÷1390 Cooling capacity: 262÷389 kW

•Efficient and compact range in R134a • Working limits up to 50°C • Range with single compressor up to 390 kW

Packaged air cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.

Models • TCAVBZ: unit designed for cooling only. • TCAVSZ: silenced unit designed for cooling only. • TCAVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and refrigerant gas delivery pipe shut-off valve. • Electronic expansion valve: standard on all models. • Water side heat exchanger: dry expansion shell and tube exchanger, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

Versions • B -Standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I -Soundproofed version with soundproofed compressor cover (TCAVIZ).

• PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.91). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Linear capacity control compressor. • Evaporator antifreeze heater and heat recovery exchangers if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Clock card • Rhoss sequencer for the integrated management of several water chillers.

350

389

… Nominal cooling capacity

kW

260

300

340

374

… E.E.R.

2,70

2,81

2,70

2,70

… E.E.R.

2,63

2,72

2,60

2,55

O E.S.E.E.R.

3,47

3,59

3,45

3,44

O E.S.E.E.R.

3,29

3,41

3,27

3,26

kW

100,0

110,0

129,5

144,0

… Absorbed power … Absorbed power

kW

99,0

110,5

130,9

146,7

‡ Sound pressure level

dB(A)

79

80

80

81

‡ Sound pressure level

dB(A)

73

74

74

75

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

Main supply DIMENSIONS AND WEIGHTS

1270

1310

1350

1390

W - Width

mm

3830

3830

3830

3830

H - Height

mm

2430

2430

2430

2430

D - Depth

mm

2260

2260

2260

2260

ˆ Weight TCAVBZ

kg

3300

3350

3650

3700

ˆ Weight TCAVSZ

kg

3450

3500

3800

3850

Q TCAVSZ silenced versions.

CONDENSING UNITS

EXP Polyvalent systems

In the following conditions: … Air: 35°C - Water: 7/12°C. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Weight refers to the accessorised unit when empty with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

AIR cooled AXIAL fans

1390

309

AIR cooled CENTRIFUGAL fans

1350

270

WATER cooled CONDENSERLESS UNITS

1310

kW

WATER CHILLERS HEAT PUMPS

1270

… Nominal cooling capacity

WATER CHILLERS HEAT PUMPS

TCAVBZ-TCAVIZ-TCAVSZ MODEL

WATER CHILLERS HEAT PUMPS

41

OUTDOOR INSTALLATION

INDUSTRIAL & PROCESS COOLING

COOLING ONLY

TERMINAL UNITS

FAN COIL UNITS

SYSTEM ACCESSORIES

TCAVZ unit undergoing testing at the Ross laboratory: R&D Lab.

Z-Power Range 42

TCAVZ 2330÷2700 H.E.

GREEN LINE

Cooling capacity: 324.8÷693.2 kW

• Efficiency range in CLASS A with EER >3.1 • Working limits up to 50°C • Wide range of accessories

TCAVSZ 2510 H.E.

High energy efficiency packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas.

TCAVSZ 2460 H.E. with Tank&Pump accessory

Models • TCAVBZ: unit designed for cooling only. • TCAVSZ: silenced unit designed for cooling only. • TCAVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger (mod. 2330÷2460): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch and Victaulic connections. • Water side heat exchanger (mod. 2510÷2700): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

Versions • B - High energy efficiency standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I - High energy efficiency soundproofed version with soundproofed compressor cover (TCAVIZ).

• Shell and tube evaporator (mod. 2330÷2460). • PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • TANK&PUMP (mod. 2330÷2460) with 1,100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Linear compressor capacity control (25-100 %). • Evaporator antifreeze heater, buffer tank and heat exchangers for heat recovery if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tin-plated copper coils. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Clock card • Rhoss sequencer for the integrated management of several water chillers.

kW

324,8

344,1

361,8

379,4

406,9

443,9

495,4

… E.E.R.

3,11

3,11

3,10

3,10

3,11

3,10

3,11

… E.E.R.

3,09

3,06

3,04

2,96

3,08

3,04

3,01

O E.S.E.E.R.

4,04

4,06

4,08

4,06

4,04

4,06

4,08

O E.S.E.E.R.

3,97

3,98

3,99

3,99

3,99

3,96

3,93

† IPLV

4,20

4,22

4,24

4,22

4,20

4,22

4,24

† IPLV

4,13

4,14

4,15

4,15

4,15

4,12

4,09

kW

107,0

113,7

120,4

126,1

134,0

148,0

164,3

… Absorbed power … Absorbed power

kW

105,1

112,5

118,9

128,1

132,2

145,9

164,4

‡ Sound pressure level

dB(A)

80

80

80

80

81

81

81

‡ Sound pressure level

dB(A)

74

74

74

74

75

75

75

No.

2/6

2/6

2/6

2/6

2/6

2/6

2/6

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2330

2350

2370

2390

2420

2460

2510

W - Width

mm

4.830

4.830

4.830

4.830

5.830

5.830

5.830

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

3.780

3.870

3.960

3.970

4.420

4.530

4.740

ˆ Weight TCAVIZ-TCAVSZ

kg

4.080

4.170

4.260

4.270

4.720

4.830

5.040

TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL

2550

2570

2610

2640

2680

2700

… Nominal cooling capacity

kW

545,0

570,1

611,1

644,7

674,5

693,2

… Nominal cooling capacity

kW

531,0

554,9

593,1

624,6

657,0

676,2

… E.E.R.

3,17

3,13

3,14

3,10

3,14

3,12

… E.E.R.

3,11

3,08

3,07

3,01

3,08

3,04

O E.S.E.E.R.

4,13

4,17

4,17

4,17

4,18

4,18

O E.S.E.E.R.

3,93

3,92

3,97

4,01

4,04

4,06

† IPLV

4,29

4,34

4,34

4,34

4,34

4,35

† IPLV

4,08

4,08

4,12

4,17

4,20

4,22

kW

172,1

182,4

194,7

207,7

214,9

222,5

… Absorbed power … Absorbed power

kW

171,0

180,2

193,5

207,5

213,5

222,3

‡ Sound pressure level

dB(A)

82

82

82

82

82

82

‡ Sound pressure level

dB(A)

76

76

76

76

76

76

No.

2/6

2/6

2/6

2/6

2/6

2/6

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2550

2570

2610

2640

2680

2700

W - Width

mm

6.680

6.680

6.680

6.680

7.680

7.680

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

5.070

5.090

5.110

5.210

6.140

6.190

ˆ Weight TCAVIZ-TCAVSZ

kg

5.370

5.390

5.410

5.510

6.440

6.490

In the following conditions: … Air: 35°C - Water: 7/12°C. † IPLV (Integrated Part Load Value) - ARI standard 550/590. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Empty weight refers to the accessorised unit with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

Q TCAVSZ silenced versions.

AIR cooled AXIAL fans

510,3

… Nominal cooling capacity

AIR cooled CENTRIFUGAL fans

458,1

WATER cooled CONDENSERLESS UNITS

2510

416,5

WATER CHILLERS HEAT PUMPS

2460

390,5

WATER CHILLERS HEAT PUMPS

2420

373,6

INDUSTRIAL & PROCESS COOLING

2390

353,2

EXP Polyvalent systems

2370

333,1

CONDENSING UNITS

2350

kW

SYSTEM ACCESSORIES

2330

… Nominal cooling capacity

FAN COIL UNITS

TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL

WATER CHILLERS HEAT PUMPS

43

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Z-Power Range 44

TCAVZ 2310÷2670 Cooling capacity: 297.5÷665.9 kW

• Efficiency range in R134a • Working limits up to 50°C • TANK&PUMP installation up to 470 kW

TCAVSZ 2600

TCAVSZ 2360 with Tank&Pump accessory

Packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas.

Models

Construction features

FACTORY FITTED ACCESSORIES

• Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger (mod. 2310÷2470): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch and Victaulic connections. • Water side heat exchanger (mod. 2500÷2670): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

Versions • B -Standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I -Soundproofed version with soundproofed compressor cover (TCAVIZ).

• TCAVBZ: unit designed for cooling only. • TCAVSZ: silenced unit designed for cooling only. • TCAVIZ: soundproofed unit designed for cooling only. • Shell and tube evaporator (mod. 2310÷2470). • PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. • TANK&PUMP (mod. 2310÷2470) with 1,100-litre built-in buffer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Linear compressor capacity control (25-100 %). • Evaporator antifreeze heater, buffer tank and heat exchangers for heat recovery if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Clock card • Rhoss sequencer for the integrated management of several water chillers.

kW

297,5

315,0

334,5

353,0

382,9

413,4

450

… E.E.R.

2,83

2,84

2,82

2,80

2,86

2,83

2,80

… E.E.R.

2,74

2,73

2,71

2,62

2,78

2,72

2,66

O E.S.E.E.R.

3,95

3,96

3,96

3,98

3,99

3,91

3,83

O E.S.E.E.R.

3,75

3,78

3,81

3,83

3,86

3,73

3,60

† IPLV

4,11

4,11

4,12

4,13

4,15

4,07

3,98

† IPLV

3,90

3,93

3,96

3,99

4,01

3,88

3,74

kW

108,4

114,8

122,3

131,4

138,2

151,1

166,7

… Absorbed power … Absorbed power

kW

108,5

115,5

123,6

134,9

137,8

152,1

169,0

‡ Sound pressure level

dB(A)

79

79

79

79

80

80

80

‡ Sound pressure level

dB(A)

73

73

73

73

74

74

74

No.

2/6

2/6

2/6

2/6

2/6

2/6

2/6

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2310

2320

2340

2360

2400

2430

2470

W - Width

mm

3.830

3.830

3.830

3.830

4.830

4.830

4.830

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

3.420

3.490

3.500

3.580

3.920

4.100

4.280

ˆ Weight TCAVIZ-TCAVSZ

kg

3.720

3.790

3.800

3.880

4.220

4.400

4.580

TCAVBZ-TCAVSZ-TCAVIZ MODEL

2500

2540

2580

2600

2650

2670

… Nominal cooling capacity

kW

505,7

538,1

575,5

607,4

646,8

665,9

… Nominal cooling capacity

kW

490,3

520,9

555,4

584,5

627,9

647,1

… E.E.R.

2,87

2,87

2,87

2,81

2,87

2,83

… E.E.R.

2,79

2,77

2,74

2,67

2,77

2,71

O E.S.E.E.R.

3,91

3,99

3,97

3,95

3,96

3,96

O E.S.E.E.R.

3,72

3,84

3,83

3,82

3,81

3,80

† IPLV

4,07

4,15

4,13

4,11

4,11

4,12

† IPLV

3,87

3,99

3,98

3,97

3,96

3,95

kW

176,1

187,3

200,7

215,9

225,4

235,7

… Absorbed power … Absorbed power

kW

175,8

187,8

202,6

219,2

226,7

238,6

‡ Sound pressure level

dB(A)

81

81

81

81

82

82

‡ Sound pressure level

dB(A)

75

75

75

75

76

76

No.

2/6

2/6

2/6

2/6

2/6

2/6

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2500

2540

2580

2600

2650

2670

W - Width

mm

5.830

5.830

5.830

5.830

6.680

6.680

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

4.760

4.780

4.800

4.820

5.160

5.210

ˆ Weight TCAVIZ-TCAVSZ

kg

5.060

5.080

5.100

5.120

5.460

5.510

In the following conditions: … Air: 35°C - Water: 7/12°C. † IPLV (Integrated Part Load Value) - ARI standard 550/590. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Empty weight refers to the accessorised unit with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

Q TCAVSZ silenced versions.

AIR cooled AXIAL fans

467,4

… Nominal cooling capacity

AIR cooled CENTRIFUGAL fans

427,9

WATER cooled CONDENSERLESS UNITS

2470

394,8

WATER CHILLERS HEAT PUMPS

2430

367,4

WATER CHILLERS HEAT PUMPS

2400

345,2

INDUSTRIAL & PROCESS COOLING

2360

326,0

EXP Polyvalent systems

2340

307,2

CONDENSING UNITS

2320

kW

SYSTEM ACCESSORIES

2310

… Nominal cooling capacity

FAN COIL UNITS

TCAVBZ-TCAVSZ-TCAVIZ MODEL

WATER CHILLERS HEAT PUMPS

45

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Z-Power Range 46

TCAVZ 2770÷21290 H.E.

GREEN LINE

Cooling capacity: 746÷1.283.4 kW

• Efficiency range in CLASS A with EER >3.2 and ESEER up to 4.57 • Working limits up to 50°C • Standard electronic expansion valve

High energy efficiency packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas.

TCAVSZ 21010 H.E.

Models • TCAVBZ: unit designed for cooling only. • TCAVSZ: silenced unit designed for cooling only. • TCAVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

• Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Linear compressor capacity control (25-100%). • Evaporator antifreeze heater and heat recovery exchangers if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

Versions • B - High energy efficiency standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I - High energy efficiency soundproofed version with soundproofed compressor cover (TCAVIZ).

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Lifting chain kit. • Rhoss sequencer for the integrated management of several water chillers.

kW

746,0

811,2

865,5

924,0

973,5

1.004,2

… E.E.R.

3,35

3,31

3,26

3,37

3,35

3,35

… E.E.R.

3,24

3,17

3,09

3,16

3,13

3,16

O E.S.E.E.R.

4,45

4,39

4,34

4,48

4,47

4,45

O E.S.E.E.R.

4,31

4,22

4,12

4,20

4,16

4,21

† IPLV

4,63

4,57

4,51

4,66

4,65

4,63

† IPLV

4,48

4,39

4,28

4,37

4,33

4,37

kW

228,0

2a51,0

272,0

284,0

301,0

310,0

… Absorbed power … Absorbed power

kW

230,6

256,1

279,8

292,6

311,5

317,9

‡ Sound pressure level

dB(A)

82

82

82

83

83

83

‡ Sound pressure level

dB(A)

76

76

76

77

77

77

No.

2/8

2/8

2/8

2/8

2/8

2/8

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2770

2830

2890

2960

21010

21040

W - Width

mm

7.680

7.680

7.680

8.980

8.980

9.980

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

5.950

6.360

6.760

7.900

7.920

7.990

ˆ Weight TCAVIZ-TCAVSZ

kg

6.290

6.700

7.100

8.250

8.260

8.340

TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL

21080

21130

21150

21220

21290

… Nominal cooling capacity

kW

1.079,9

1.125,9

1.152,3

1.217,9

1.283,4

… Nominal cooling capacity

kW

1.051,1

1.099,9

1.116,2

1.178,1

1.240,4

… E.E.R.

3,36

3,23

3,43

3,40

3,39

… E.E.R.

3,22

3,08

3,21

3,14

3,08

O E.S.E.E.R.

4,48

4,29

4,57

4,53

4,51

O E.S.E.E.R.

4,29

4,10

4,27

4,16

4,10

† IPLV

4,66

4,46

4,75

4,71

4,69

† IPLV

4,47

4,26

4,44

4,33

4,26

kW

321,0

349,0

336,0

358,0

379,0

… Absorbed power … Absorbed power

kW

326,0

357,0

348,0

375,8

402,2

‡ Sound pressure level

dB(A)

84

84

84

84

84

‡ Sound pressure level

dB(A)

78

78

78

78

78

No.

2/8

2/8

2/8

2/8

2/8

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

21080

21130

21150

21220

21290

W - Width

mm

10.980

10.980

10.980

10.980

10.980

H - Height

mm

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

7.960

8.720

9.160

9.200

9.240

ˆ Weight TCAVIZ-TCAVSZ

kg

8.300

9.070

9.510

9.560

9.590

In the following conditions: … Air: 35°C - Water: 7/12°C. † IPLV (Integrated Part Load Value) - ARI standard 550/590. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Empty weight refers to the accessorised unit with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

Q TCAVSZ silenced versions.

AIR cooled AXIAL fans

… Nominal cooling capacity

AIR cooled CENTRIFUGAL fans

1.037,3

WATER cooled CONDENSERLESS UNITS

1.009,7

WATER CHILLERS HEAT PUMPS

21040

956,8

WATER CHILLERS HEAT PUMPS

21010

887,8

INDUSTRIAL & PROCESS COOLING

2960

831,5

EXP Polyvalent systems

2890

764,5

CONDENSING UNITS

2830

kW

SYSTEM ACCESSORIES

2770

… Nominal cooling capacity

FAN COIL UNITS

TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL

WATER CHILLERS HEAT PUMPS

47

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Z-Power Range 48

TCAVZ 2710÷21600 Cooling capacity: 690÷1.602 kW

• Efficiency range in R134a • Installation flexibility up to 1,600 kW • Standard electronic expansion valve

TCAVSZ 21600 with DS accessory and pumping group

Packaged air cooled water chillers with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas.

Models • TCAVBZ: unit designed for cooling only. • TCAVSZ: silenced unit designed for cooling only. • TCAVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

• Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • -15°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Linear compressor capacity control (25-100 %). • Evaporator antifreeze heater and heat recovery exchangers if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

Versions

ACCESSORIES SUPPLIED LOOSE

• B -Standard version (TCAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I -Soundproofed version with soundproofed compressor cover (TCAVIZ).

• Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Lifting chain kit. • Rhoss sequencer for the integrated management of several water chillers.

… Nominal cooling capacity

kW

690,0

732,0

785,9

838,0

908,6

954,0

984,6

… E.E.R.

2,96

2,98

2,96

2,91

3,01

2,98

3,05

… E.E.R.

2,82

2,85

2,82

2,77

2,86

2,81

2,87

O E.S.E.E.R.

3,96

3,96

3,93

3,88

4,00

3,98

4,05

O E.S.E.E.R.

3,80

3,79

3,76

3,69

3,80

3,73

3,82

† IPLV

4,10

4,12

4,09

4,03

4,17

4,14

4,21

† IPLV

3,92

3,94

3,91

3,83

3,95

3,89

3,97

kW

240,0

252,0

273,2

296,2

310,6

329,9

333,4

… Absorbed power … Absorbed power

kW

245,0

257,0

278,4

303,0

318,2

339,6

343,3

‡ Sound pressure level

dB(A)

82

82

82

82

82

82

82

‡ Sound pressure level

dB(A)

76

76

76

76

76

76

76

No.

2/8

2/8

2/8

2/8

2/8

2/8

2/8

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2710

2750

2810

2870

2940

2990

21020

W - Width

mm

6.680

6.680

7.680

7.680

7.680

7.680

7.680

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

5.310

5.310

6.400

6.620

6.790

6.820

6.940

ˆ Weight TCAVIZ-TCAVSZ

kg

5.610

5.610

6.750

6.970

7.140

7.170

7.290

21060

21110

21180

21250

21400

21500

21600

… Nominal cooling capacity

kW

1.051,6

1.107,3

1.179,7

1.251,5

1.400,0

1.507,6

1.602,0

… Nominal cooling capacity

kW

TCAVBZ-TCAVSZ-TCAVIZ MODEL

1.019,7

1.071,8

1.142,7

1.212,2

1.353,0

1.454,0

1.548,0

… E.E.R.

3,13

2,99

3,07

3,15

3,12

3,13

3,11

… E.E.R.

2,95

2,78

2,85

2,90

2,92

2,90

2,80

O E.S.E.E.R.

4,18

3,98

4,09

4,19

4,01

4,06

4,08

O E.S.E.E.R.

3,93

3,70

3,77

3,87

3,82

3,81

3,72

† IPLV

4,34

4,14

4,25

4,35

4,30

4,33

4,29

† IPLV

4,09

3,85

3,93

4,02

4,01

4,00

3,87

kW

335,7

370,5

384,3

397,7

448,8

480,9

515,0

… Absorbed power … Absorbed power

kW

346,0

385,0

401,2

417,3

464,0

502,0

553,0

‡ Sound pressure level

dB(A)

83

83

83

83

85

85

85

‡ Sound pressure level

dB(A)

77

77

77

77

79

79

79

No.

2/8

2/8

2/8

2/8

2/8

2/8

2/8

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

21060

21110

21180

21250

21400

21500

21600

W - Width

mm

7.680

8.980

8.980

8.980

12.980

12.980

12.980

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

2.260

ˆ Weight TCAVBZ

kg

6.970

8.530

8.740

8.930

9.560

9.840

10.080

ˆ Weight TCAVIZ-TCAVSZ

kg

7.390

8.880

9.090

9.280

9.910

10.190

10.430

In the following conditions: … Air: 35°C - Water: 7/12°C. † IPLV (Integrated Part Load Value) - ARI standard 550/590. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Empty weight refers to the accessorised unit with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

Q TCAVSZ silenced versions.

AIR cooled AXIAL fans

1.015,5

AIR cooled CENTRIFUGAL fans

984,6

WATER cooled CONDENSERLESS UNITS

21020

935,5

WATER CHILLERS HEAT PUMPS

2990

863,4

WATER CHILLERS HEAT PUMPS

2940

809,3

INDUSTRIAL & PROCESS COOLING

2870

751,1

EXP Polyvalent systems

2810

710,0

CONDENSING UNITS

2750

kW

SYSTEM ACCESSORIES

2710

… Nominal cooling capacity

FAN COIL UNITS

TCAVBZ-TCAVSZ-TCAVIZ MODEL

WATER CHILLERS HEAT PUMPS

49

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Z-Power Range 50

THAVZ 2400÷2680 Cooling capacity: 384÷680 kW - Heating capacity: 409÷700 kW

• Efficient heat pumps in R134a • Extensive working limits • Production of hot water up to 55°C

Packaged air-cooled reversible heat pumps with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas.

THAVSZ 2530

Models • THAVBZ: heat pump unit. • THAVSZ: silenced heat pump unit. • THAVIZ: soundproofed heat pump unit.

FACTORY FITTED ACCESSORIES Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater, refrigerant gas delivery piping shut-off valve and compressor oil level sensor. • Electronic expansion valve: as standard on all models. • Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

Versions • B - Standard version (THAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I -Soundproofed version with soundproofed compressor cover (THAVIZ).

• Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • -10°C condensation control. • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Evaporator antifreeze heater and heat recovery exchangers if present. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

467

540

595

672

3,00

3,06

3,17

3,15

3,17

†C.O.P. †C.O.P.

2,90

2,95

3,06

3,04

3,06

… Nominal cooling capacity

kW

400

464

532

600

680

… Nominal cooling capacity

kW

384

446

511

576

653

2,70

2,81

2,88

2,97

3,00

… E.E.R. … E.E.R.

2,60

2,71

2,78

2,86

2,90

† Absorbed power

kW

141,9

158,9

177,6

196,8

220,7

† Absorbed power

kW

141,2

158,1

176,7

195,8

219,6

… Absorbed power

kW

148,2

165,4

184,7

202,4

226,4

… Absorbed power

kW

147,5

164,6

183,8

201,4

225,3

‡ Sound pressure level THAVBZ

dB(A)

80

81

81

82

82

‡ Sound pressure level THAVSZ

dB(A)

74

75

75

76

76

ˆ Sound power level THAVBZ

dB(A)

98

98

98

99

99

ˆ Sound power level THAVSZ

dB(A)

92

92

92

93

93

No.

2/6

2/6

2/6

2/6

2/6

Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

2400

2460

2530

2600

2680

W - Width

mm

6.130

6.130

6.130

6.980

7.980

H - Height

mm

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

‰ Weight THAVBZ

kg

5.000

5.310

5.470

6.300

7.235

‰ Weight THAVSZ-THAVIZ

kg

5.300

5.610

5.770

6.600

7.535

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C. ‡ At 1 m from the unit in free field (Q = 2) (average value measured on 4 sides). ˆ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Weight refers to the accessorised unit when empty with RPE - KRP. O ESEER (European Seasonal EER) - Average European seasonal efficiency.

Q THAVSZ Silenced version.

AIR cooled AXIAL fans

409

AIR cooled CENTRIFUGAL fans

kW

WATER cooled CONDENSERLESS UNITS

700

† Nominal heating capacity

WATER CHILLERS HEAT PUMPS

620

WATER CHILLERS HEAT PUMPS

2680

563

INDUSTRIAL & PROCESS COOLING

2600

486

EXP Polyvalent systems

2530

426

CONDENSING UNITS

2460

kW

SYSTEM ACCESSORIES

2400

† Nominal heating capacity

FAN COIL UNITS

THAVBZ-THAVIZ-THAVSZ MODEL

WATER CHILLERS HEAT PUMPS

51

OUTDOOR INSTALLATION

TERMINAL UNITS

HEAT PUMP

T-Power Range 52

TCATBZ 1250-2600/TCATTZ 1260-41280 H.E.

GREEN LINE

Cooling capacity: 250÷1,280 kW

• Range in CLASS A with EER up to 3.61 • Oil-free, efficient silent compressor with low starting current • H.E. version with flooded evaporator

Packaged air cooled water chillers with axial fans. Range with oil-free centrifugal compressors and R134a refrigerant gas.

Versions • B - Standard version with dry expansion evaporator (TCATBZ). • T - High energy efficiency version with flooded evaporator (TCATTZ).

Models Construction features • Compressor: high energy efficiency, oil free, centrifugal compressor with limited start, equipped with magnetic levitation bearings and complete with integral protection and suction and supply shut-off valves • Electronic expansion valve: as standard on all models. • Water side heat exchanger: dry expansion (TCATBZ) or flooded type (TCATTZ) shell and tube exchanger, complete with closed cell polyurethane foam rubber insulation, water flow differential pressure switch and threaded or Victaulic connections depending on the models. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: electronic microprocessor control with serial interface for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating • The unit is also complete with: - condensation control down to an external air temperature of –10°C; - compressor and fan thermal overload switches; - low and high pressure gauges for each refrigerant circuit.

• TCATBZ: unit designed for cooling only. • TCATTZ: unit designed for cooling only.

FACTORY FITTED ACCESSORIES • Power factor correction capacitors (cosφ > 0.94). • Bottom compartment protection grilles. • Heat exchanger antifreeze heater (TCATBZ only). • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Touch screen display.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

2600 600

3,10

3,10

3,12

3,11

3,11

3,10

3,12

4,86

5,11

4,93

5,15

5,03

5,17

5,21

kW

80,6

96,8

112,2

128,6

144,7

161,3

192,3

‡ Sound power level

dB(A)

88

88

90

90

90

90

91

ˆ Sound pressure level

dB(A)

58

58

60

60

60

60

61

No.

1/infinite

1/infinite

2/infinite

2/infinite

2/infinite

2/infinite

2/infinite

… Absorbed power

Step/compressor Circuits Main supply

No.

1

1

1

1

1

1

1

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

1250

1300

2350

2400

2450

2500

2600

W - Width

mm

3.830

3.830

4.830

4.830

5.830

5.830

6.680

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

2.260

1260

1320

2350

2400

2450

2520

2640

260

320

350

400

450

520

640

3,52

3,46

3,33

3,54

3,54

3,60

3,46

TCATTZ MODEL … Nominal cooling capacity

kW

… E.E.R. O E.S.E.E.R.

5,09

5,57

5,19

5,42

5,28

5,50

5,59

kW

73,9

92,5

105,1

113,0

127,1

144,4

185,0

‡ Sound power level

dB(A)

88

88

90

90

90

90

91

ˆ Sound pressure level

dB(A)

58

58

60

60

60

60

61

No.

1/infinite

1/infinite

2/infinite

2/infinite

2/infinite

2/infinite

2/infinite

… Absorbed power

Step/compressor Circuits Main supply

No.

1

1

1

1

1

1

1

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

1260

1320

2350

2400

2450

2520

2640

W - Width

mm

3.830

3.830

4.830

4.830

5.830

5.830

6.680

H - Height

mm

2.430

2.430

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

2.260

2.260

TCATTZ MODEL

3720

3780

3960

41040

41280

720

780

960

1040

1280

… E.E.R.

3,61

3,57

3,42

3,56

3,46

O E.S.E.E.R.

5,53

5,44

5,58

5,56

5,58

kW

199,4

218,5

280,7

292,1

369,9

‡ Sound power level

dB(A)

92

92

93

93

94

ˆ Sound pressure level

dB(A)

62

62

63

63

64

No.

3/infinite

3/infinite

3/infinite

4/infinite

4/infinite

… Nominal cooling capacity

… Absorbed power

Step/compressor Circuits Main supply

kW

No.

1

1

1

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS

3720

3780

3960

41040

41280

W - Width

mm

7.680

8.980

9.980

10.980

12.980

H - Height

mm

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

In the following conditions: … Air: 35°C - Water: 7/12°C. ‡ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ˆ At 10 m from the unit in free field (Q = 2). O ESEER (European Seasonal EER) - Average European seasonal efficiency.

AIR cooled AXIAL fans

500

AIR cooled CENTRIFUGAL fans

2500

450

WATER cooled CONDENSERLESS UNITS

2450

400

WATER CHILLERS HEAT PUMPS

2400

350

WATER CHILLERS HEAT PUMPS

2350

300

INDUSTRIAL & PROCESS COOLING

O E.S.E.E.R.

1300

250

EXP Polyvalent systems

… E.E.R.

1250

CONDENSING UNITS

kW

SYSTEM ACCESSORIES

… Nominal cooling capacity

FAN COIL UNITS

TCATBZ MODEL

WATER CHILLERS HEAT PUMPS

53

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Low consumption Mini-Y range 54

TCCEY-THCEY 105÷111

GREEN LINE

Cooling capacity: 4.8÷10.4 kW - Heating capacity: 5÷11 kW

• Compact and Plug&Play units

Packaged air-cooled water chillers and reversible heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R410A refrigerant gas.

FACTORY FITTED ACCESSORIES • Soft - start device (for models with power supply 230V). • -10°C condensation control. • Low pressure switch. • Crankcase heater compressor.

Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille. • Fan: centrifugal electric fan with directly coupled motor, fitted with internal thermal protection and protection grilles. • Control: microprocessor electronic control available in 2 versions: standard, with Adaptive Function logic, and iDRHOSS compatible, with Adaptive Function Plus logic • Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THCEY.

Models • TCCEY: unit designed for cooling only. • THCEY: heat pump unit.

Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • -10°C condensation control. • Water filter • Low pressure switch. • Antifreeze electric heater on the buffer tank. • Inlet antivibration connection. • Outlet antivibration connection. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management.

Option with control PUMP unit • Pumping group complete with: circulator, expansion tank with membrane, safety valve.

TANK & PUMP unit • Pumping group complete with: water buffer tank, circulator pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve.

• 3-way valve for the production of hot water. • External air temperature probe for set-point compensation. • Additional electric heater for heat pump, managed by regulation. • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

2,27

2,27 / 2,36

2,51

2,61

2,55 / 2,58

- E.S.E.E.R.+

2,80

2,76

2,89

2,78 / 2,84

… Absorbed power (*)

kW

2,05

2,59

3,61

4,40

† Nominal heating capacity

kW

5,0

6,3

8,3

10,6 / 11,0

† C.O.P.

2,33

2,49

2,29

2,52 / 2,62

kW

2,14

2,53

3,62

4,20

‡ Sound pressure level

dB(A)

47

48

50

51

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

† Absorbed power (*)

Circuits Fan nominal air flow External head pressure Water tank content … Circulator pump available static pressure Main supply

No.

1

1

1

1

m/h

2.450

2.400

2.650

2.600

Pa

80

70

80

70

l

19

19

30

30

kPa

60

60

87

79

V-ph-Hz

230-1-50

230-1-50 /

230-1-50 /

230-1-50 /

DIMENSIONS AND WEIGHTS

400-3+N-50

400-3+N-50

400-3+N-50

105

107

109

111

W - Width

mm

990

990

990

990

H - Height PUMP

mm

940

940

1.125

1.125

H - Height TANK & PUMP

mm

940

940

1.330

1.330

D - Depth

mm

630

630

630

630

ˆ Weight TCCEY

kg

143

145

164

178

ˆ Weight THCEY

kg

153

155

174

188

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 45/40°C. ‡ At 5 m from the unit in free field (Q = 2). ˆ The weight refers to the unit in its most complete form.

O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) Unit without pump.

Condensati AIR cooled ad ARIA Ventialtori AXIALELICOIDALI fans

2,27

2,52

AIR cooled CENTRIFUGAL fans

2,34

O E.S.E.E.R.

WATER cooled CONDENSERLESS UNITS

… E.E.R.

WATER CHILLERS HEAT PUMPS

10,0 / 10,4

WATER CHILLERS HEAT PUMPS

111

8,2

INDUSTRIAL & PROCESS COOLING

109

5,9

EXP Polyvalent systems

107

4,8

kW

CONDENSING UNITS

105

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCCEY-THCEY MODEL

WATER REFRIGERATORI CHILLERS POMPE HEATDI PUMPS CALORE

55

INDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Compact Range 56

TCCE-THCE 114÷126 Cooling capacity: 13.5÷22 kW - Heating capacity: 13.6÷24 kW

• Vertical or horizontal air discharge

Packaged air-cooled water chillers and reversible heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille. • Fan: centrifugal electric fans with directly coupled motor, fitted with internal thermal protection and protection grilles. • The condensation air supply is vertical. • Control: microprocessor electronic control available in 2 versions: standard and iDRHOSS compatible, with Adaptive Function logic. • Structure: peraluman, complete with condensation drain pan for THCE.

Models • TCCE: unit designed for cooling only. • THCE: heat pump unit.

STANDARD unit • Without pumping group and buffer tank.

TANK & PUMP unit • With standard pump. • With high-pressure pump. Pumping group complete with: water buffer tank, standard or high-pressure circulation pump for models 114-117 only, expansion tank with membrane, manual air bleed valve, safety valve and water drain tap. 

FACTORY FITTED ACCESSORIES • Horizontal condensation air outlet. • Antifreeze electric heater on the buffer tank.

Option with control • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • -10°C condensation control. • Inlet antivibration connection. • Outlet antivibration connection. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management.

Option with control • Additional electric heater for heat pump, not managed by regulation. • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

2,40

2,34

5,31

6,13

7,57

9,40

† Nominal heating capacity

kW

13,6

16,4

20,1

24,0

2,58

2,72

2,80

2,71

kW

5,27

6,02

7,18

8,86

‡ Sound pressure level

dB(A)

54

55

56

57

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

† C.O.P. † Absorbed power (*)

Circuits Fan nominal air flow External head pressure Water tank content … Available head pressure of standard pump

No.

1

1

1

1

m/h

4.720

4.110

5.040

4.485

Pa

90

80

90

80

l

55

55

80

80

kPa

50

48

170

159

… Available head pressure of high pressure pump kPa Main supply

179

165





V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

114

117

121

126

mm

1.320

1.320

1.710

1.710

DIMENSIONS AND WEIGHTS W - Width H - Height STANDARD

mm

1.305

1.305

1.305

1.305

H - Height TANK & PUMP

mm

1.600

1.600

1.600

1.600

D - Depth

mm

558

558

643

643

ˆ Weight TCCE

kg

340

360

420

460

ˆ Weight THCE

kg

350

370

440

470

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - 70% R.H. - Water: 45/40°C. ‡ At 5 m from the unit in free field (Q = 2), with ducted fans. ˆ The weight refers to the unit in its most complete form. (*) Unit without pump.

Condensati AIR cooled ad ARIA Ventialtori AXIALELICOIDALI fans

2,53

kW

AIR cooled CENTRIFUGAL fans

2,55

… Absorbed power (*)

WATER cooled CONDENSERLESS UNITS

126 22,0

WATER CHILLERS HEAT PUMPS

121 18,2

WATER CHILLERS HEAT PUMPS

117 15,5

INDUSTRIAL & PROCESS COOLING

… E.E.R.

114 13,5

EXP Polyvalent systems

kW

CONDENSING UNITS

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCCE-THCE MODEL

WATER REFRIGERATORI CHILLERS POMPE HEATDI PUMPS CALORE

57

INDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

58

TCCE-TCPE-THCE-THPE 130÷270 Cooling capacity: 30,1÷66,3 kW - Heating capacity: 34,9÷77,1 kW

Packaged air-cooled water chillers and reversible heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features • Compressor: hermetic rotary Scroll compressor. • Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: centrifugal electric fans with external motor, belt transmission and adjustable pulley. • The condensation air supply is horizontal (suction side). • Control: microprocessor electronic control. • Structure: load-bearing galvanized and painted sheet steel structure with epoxy powder coating and compressor compartment lined internally with soundproofing material.

Versions • B - Standard version with standard fans (TCCEB-THCEB) and highpressure fans (TCPEB-THPEB).

Models • TCCEB: unit designed for cooling only. • THCEB: heat pump unit. • TCPEB: unit designed for cooling only. • THPEB: heat pump unit.

FACTORY FITTED ACCESSORIES • TANK&PUMP with integrated buffer tank from 80 to 150 litres and single or double pump.

• PUMP with pumps for primary circuit or for primary circuits and secondary circuits. • CC for unit operation in cooling mode, with external air temperature up to 10 °C. • LOW AMBIENT (TCCE-TCPE only) for unit operation with low external air temperature (down to –10°C). • Vertical condensation air supply. • Protection coil grilles • Refrigerant circuit high and low pressure gauges. • Evaporator antifreeze electric heater.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • RS 485 serial interface. • RS 232 hardware key.

TANK & PUMP ACCESSORY • Built-in pumping group complete with: water buffer tank, circulation pump, expansion tank, pressure gauge, bleed and safety valve and water drain. • The pump is available in a single or double configuration, including one in stand-by, and in 4 sizes for combination with the TCCE-TCPE and THCE-THPE units.

PUMP ACCESSORY Version fitted with a maximum of 3 pumps: • P - Primary circuit pump in single configuration. • DP - Primary circuit pump in double configuration, with one in stand-by. • PU - Secondary circuit pump in single configuration. • DPU - Secondary circuit pump in double configuration, in combination with primary circuit pump.

150

160

270

37,3

47,2

59,4

66,3 77,1

kW

34,9

41,2

43,1

55,9

65,3

‡ Sound pressure level

dB(A)

54

59

57

57

60

64

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

1/1

2/2

Circuits Fan nominal air flow

No.

1

1

1

1

1

1

m/h

8.500

11.000

15.000

15.000

17.000

20.000

… Max. available static pressure fan … Absorbed power TCCEB † Absorbed power THCEB

Pa

145

155

125

125

150

155

kW

12,1

14,5

14,9

18,7

22,9

28,8

kW

11,4

13,8

13,6

17,8

21,5

28,8

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

130

135

140

150

160

270

mm

1.855

1.855

2.355

2.355

2.355

2.355

H - Height

mm

1.916

1.916

1.916

1.916

1.916

1.916

D - Depth

mm

910

910

1.010

1.010

1.010

1.010

ˆ Weight TCCEB-TCPEB

kg

646

666

781

885

946

1.022

ˆ Weight THCEB-THPEB

kg

669

687

805

910

982

1.057

Main supply DIMENSIONS AND WEIGHTS W - Width

INDUSTRIAL & PROCESS COOLING

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C. ‡ At 5 m from the unit in free field (Q = 1), with ducted fans. ˆ Weight refers to the fully accessorised unit when empty.

TANK & PUMP TCCEB-THCEB-TCPEB-THPEB MODEL Nominal flow Water tank content

130

135

140

150

160

270

l/h

5.177

5.934

6.416

8.118

10.217

11.404

l

80

80

150

150

150

150 –

Available head pressure of TANK & PUMP pump Pump P1

KPa

136

132

138

130



Pump P3

KPa

218

214

219

215





Pump P5

KPa









138

129

Pump P7

KPa









279

275

PUMP P (pump for primary circuit) TCCEB-THCEB-TCPEB-THPEB MODEL

130

135

140

150

160

270

l/h

5.177

5.934

6.416

8.118

10.217

11.404

Pump P1

KPa

141

140

139

135





Pump P3

KPa

222

222

220

215





Pump P5

KPa









141

137

Pump P7

KPa









284

280

Nominal flow

SYSTEM ACCESSORIES

Available head pressure of PUMP P pump

135

140

150

160

270

5.177

5.934

6.416

8.118

10.217

11.404

Pump P1/PU1

KPa

161

160

159

158





Pump P1/PU3

KPa

243

242

241

239





Pump P5/PU5

KPa









165

164

Pump P5/PU7

KPa









309

305

Available head pressure of PUMP P/PU pump

TERMINAL UNITS

130 l/h

Nominal flow

FAN COIL UNITS

PUMP P/PU (pumps for primary and secondary circuit) TCCEB - THCEB - TCPEB - THPEB MODEL

Condensati AIR cooled ad ARIA Ventialtori AXIALELICOIDALI fans

140

34,5

AIR cooled CENTRIFUGAL fans

135

30,1

WATER cooled CONDENSERLESS UNITS

† Nominal heating capacity

130 kW

WATER CHILLERS HEAT PUMPS

… Nominal cooling capacity

WATER CHILLERS HEAT PUMPS

TCCEB-THCEB-TCPEB-THPEB MODEL

WATER REFRIGERATORI CHILLERS POMPE HEATDI PUMPS CALORE

59

INDOOR INSTALLATION

EXP Polyvalent systems

HEAT PUMP

CONDENSING UNITS

COOLING ONLY

Low consumption Comby-Flow range 60

TCHEY-THHEY 105÷112

GREEN LINE

Cooling capacity: 5.4÷12 kW - Heating capacity: 6.5÷13.9 kW

• ESEER with Adaptive Function Plus up to 4.5 • Extremely compact and silent units

Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas.

FACTORY FITTED ACCESSORIES • Pressure switch valve • Pressure switch valve and bypass solenoid valve (only THHEY).

Option with control Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Well or water pipe side heat exchanger (disposal unit): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch (for THHEY). • Control: microprocessor electronic control available in 2 versions: standard, with Adaptive Function logic, and iDRHOSS compatible, with Adaptive Function Plus logic • Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment.

• Water circuit heat pump (for TCHEY only). • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • Water buffer tank • Buffer connection pipes • Water filter • Antivibration rubber mountings. • Antifreeze electric heater on the buffer tank. • Low pressure switch. • Remote keyboard with display. • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management.

Models • TCHEY: unit designed for cooling only. • THHEY: heat pump unit.

STANDARD unit • Without electric circulation pump. Primary side (user): expansion tank with membrane, safety valve, water drain valve, manual air bleed valve, gauge.

PUMP unit • With circulation pump. Primary side (user): pumping group complete with circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge.

Option with control • 3-way valve for the production of hot water. • External air temperature probe for set-point compensation. • Additional electric heater for heat pump, managed by regulation. • Clock card • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

3,40

3,33

3,76

3,95

3,91

- E.S.E.E.R.+

4,00

4,25

4,46

4,34

… Absorbed power (*)

kW

1,56

2,12

2,74

3,60

† Nominal heating capacity

kW

6,5

8,2

10,8

13,9

3,18

2,84

3,05

3,17 4,38

† C.O.P. † Absorbed power (*)

kW

2,04

2,88

3,54

‡ Nominal cooling capacity (radiating)

kW

7,7

10,5

13,6

17,8

5,30

5,02

5,04

4,86

‡ E.E.R. (radiating) ‡ Absorbed power (radiating) (*)

kW

1,5

2,1

2,7

3,7

ˆ Heating capacity (radiating)

kW

7,4

9,6

12,6

14,9

ˆ C.O.P. (radiating)

5,04

4,82

4,81

4,72

ˆ C.O.P. (**)

4,40

4,42

4,40

4,42

ˆ Absorbed power (radiating) (*)

kW

1,5

2,0

2,6

3,2

‰ Heating capacity (geothermal)

kW

5,1

6,7

8,3

11,0 3,33

‰ C.O.P. (geothermal)

3,40

2,91

3,07

kW

1,5

2,3

2,7

3,3

dB(A)

49,1

51,1

51,3

53,1

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

Circuits

No.

1

1

1

1

l

20

20

30

30

‰ Absorbed power (geothermal) (*) Š Sound pressure level

Water buffer tank content KA … Available head pressure of pump Main supply

kPa

47

55

82

78

V-ph-Hz

230-1-50

230-1-50

230-1-50

230-1-50

DIMENSIONS AND WEIGHTS

400-3+N-50

400-3+N-50

400-3+N-50

105

107

109

112

W - Width

mm

585

585

660

660

H - Height STANDARD - PUMP

mm

535

535

535

535

H - Height STANDARD - PUMP + KA

mm

855

855

855

855

D - Depth

mm

386

386

420

420

ΠWeight TCHEY P

kg

75

80

90

93

ΠWeight THHEY P

kg

78

83

94

97

Weight KA

kg

28

28

33

33

In the following conditions: … Chilled water: 7/12°C. - Condenser water: 30/35°C. † Hot water: 40/45°C. - Evaporator water: 10°C. - Water flow rate as in summer operation. ‡ Chilled water: 18/23°C - Condenser water: 30/35°C. ˆ Hot water: 30/35°C. - Evaporator water: 10°C. - Water flow rate as in summer operation. ‰ Hot water: 30/35°C. - Evaporator water: 0/–3°C, 30% glycol. Š At 1 m from the unit, in free field (Q = 2). Œ The weight refers to the unit in its most complete form.

O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) STANDARD unit. (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511). KA = Water buffer tank. KTC = Connection pipes.

AIR cooled AXIAL fans

3,20

3,54

AIR cooled CENTRIFUGAL fans

3,47

O E.S.E.E.R.

WATER cooled CONDENSERLESS UNITS

… E.E.R.

WATER CHILLERS HEAT PUMPS

12,0

WATER CHILLERS HEAT PUMPS

112

9,3

INDUSTRIAL & PROCESS COOLING

109

6,8

EXP Polyvalent systems

107

5,4

kW

CONDENSING UNITS

105

… Nominal cooling capacity

SYSTEM ACCESSORIES

TCHEY-THHEY MODEL

WATER CHILLERS HEAT PUMPS

61

INDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Low consumption Y-Flow range 62

TCHEY-THHEY 115÷240

GREEN LINE

Cooling capacity: 15.5÷41.8 kW - Heating capacity: 17.36÷44.9 kW

• CLASS A unit (radiant systems) • Applications with ground or city water or geothermal probes • Plug&Play unit with hydraulic connections on the top

Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Disposal unit side heat exchanger (well/water pipe/geothermal probes): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch (for THHEY). • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. • Structure: in galvanised and polyester powder coated sheet steel, fully covered with sound-absorbing panels.

Models • TCHEY: unit designed for cooling only. • THHEY: heat pump unit.

STANDARD unit Without circulation pump and hydraulic accessories.

PUMP unit With circulation pump. • Primary side (user): pumping group complete with standard or high-pressure circulation pump, expansion tank with membrane, safety valve, water supply/drainage valve, manual air bleed valve, pressure gauge.

• Disposal unit side (dry cooler/geothermal probes): pumping group complete with phase cutting pump, water supply/drainage valve, manual air bleed valve.

FACTORY FITTED ACCESSORIES • Silenced configuration. • Pressure switch valve with water flow blocking solenoid. • Pressure switch valve with water flow blocking solenoid and bypass solenoid valve. • Water circuit heat pump (for TCHEY only). • Soft-start device. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • 3-way valve for the production of hot water. • Additional electric heater for heat pump, managed by regulation. • External air temperature probe for set-point compensation. • Freecooling kit. • Water filter • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

3,4

3,7

4,7

5,3

6,9

8,5

4,56

5,02

4,86

4,95

4,41

4,95

O E.S.E.E.R

5,71

6,18

6,10

6,15

5,51

6,17

- E.S.E.E.R.+

6,28

6,80

6,77

6,83

6,17

6,91

† Heating capacity THHEY

kW

17,31

20,07

24,96

28,76

35,73

44,91

† Absorbed power (*)

kW

3,9

4,6

5,8

6,5

8,1

10,5

4,47

4,40

4,31

4,44

4,43

4,28

18,50

21,36

26,50

30,64

38,29

47,72

†C.O.P. ‡ Heating capacity THHEY

kW

† Absorbed power (*)

kW

‡ C.O.P. ‡ C.O.P. (**) (***)

3,2

3,4

4,3

4,9

6,4

7,9

5,79

6,20

6,11

6,23

5,94

6,05

5,69

6,04

5,99

6,10

5,78

5,90

ˆ Heating capacity (geothermal) THHEY

kW

14,10

16,10

19,50

22,50

28,6

35,4

ˆ Absorbed power (geothermal) (*)

kW

3,20

3,50

4,10

4,80

6,5

7,7

4,41

4,60

4,76

4,69

4,40

4,60

ˆ C.O.P. (geothermal) ˆ C.O.P. (***) ‰ Cooling capacity TCHEY/THHEY

kW

‰ Absorbed power TCHEY (*)

kW

‰ E.E.R. TCHEY ‰ E.E.R. THHEY (***)

4,37

4,55

4,72

4,65

4,35

4,55

22,17/19,89

25,88/22,98

31,80/27,94

36,67/32,21

43,50/39,02

59,06/50,78

3,3

3,8

4,9

5,7

6,7

9,0

6,69

6,76

6,51

6,45

6,46

6,55 5,36

5,57

5,54

5,45

5,42

5,50

dB(A)

53

53

57

58

59

62

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

2/2

2/2

Circuits

No.

1

1

1

1

1

1

… Available head pressure P1/P2 system side

kPa

84/157

79/141

75/163

110/135

98/119

101/127

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

115

118

122

125

230

240

Š Sound power level

Main supply DIMENSIONS AND WEIGHTS W - Width

mm

700

700

700

700

700

700

H - Height STANDARD - PUMP

mm

1.100

1.100

1.100

1.100

1.100

1.100

D - Depth

mm

560

560

780

780

780

780

‹WeightsTCHEY

kg

189

189

227

250

273

293

‹WeightsTHHEY

kg

193

193

230

254

278

298

In the following conditions: … Chilled water: 7/12°C. - Condenser water: 30/35°C. † Hot water: 40/45°C. - Evaporator water: 10°C. - Water flow rate as in summer operation. ‡ Hot water: 35/30°C. - Condenser water: 10/7°C. ˆ Hot water: 30/35°C. - Evaporator water: 0/–3°C, 30% glycol. ‰ Hot water: 18/23°C. - Condenser water: 30/35°C. Š Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744.

‹ The weight refers to the unit in its most complete form. O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (*) STANDARD unit. (**) Reference for the tax credit for the French market (in accordance with the standard EN 14511). (***) Energy ratings for standard units, calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market.

AIR cooled AXIAL fans

240 41,89/36,02

AIR cooled CENTRIFUGAL fans

230 30,58/27,44

WATER cooled CONDENSERLESS UNITS

125 26,36/23,16

WATER CHILLERS HEAT PUMPS

122 22,83/20,06

WATER CHILLERS HEAT PUMPS

kW

118 18,49/16,42

INDUSTRIAL & PROCESS COOLING

… Absorbed power TCHEY (*) … E.E.R. TCHEY

115 15,58/13,98

EXP Polyvalent systems

kW

CONDENSING UNITS

… Cooling capacity TCHEY/THHEY

SYSTEM ACCESSORIES

TCHEY-THHEY MODEL

WATER CHILLERS HEAT PUMPS

63

INDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Low consumption Y-Flow range 64

TCHEY-THHEY 245÷4450

GREEN LINE

Cooling capacity: 45.2÷450.8 kW - Heating capacity: 50÷512.7 kW

• CLASS A unit (radiant systems) • Applications with ground or city water or geothermal probes • Wide range of accessories

Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Disposal unit side heat exchanger (ground/city water/geothermal probes): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch (for THHEY). • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. • Structure: in galvanised and painted sheet steel, with polyester powder coating.

Models • TCHEY: unit designed for cooling only. • THHEY: heat pump unit.

FACTORY FITTED ACCESSORIES • Primary side (user) PUMP: with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve, water charge/drain valve, air bleed valve, pressure gauge. The pumps are available in the low or high pressure versions. £

• Plant-system PUMP (dry cooler/geothermal probes): with inverter driven single or double pump, including an automatic pump in stand-by. £ • Desuperheater. £ • 100% heat recovery. £ • Water circuit heat pump (for TCHEY only). • Electronic expansion valve. • Soft starter. • Refrigerant circuit high and low pressure gauges. • Silenced configuration. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • Modulating 3-way valve for condensation control. • Modulating 2-way valve for condensation control. • External air temperature probe for set-point compensation. • Freecooling kit. • Water filter • Antivibration rubber mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

£The units can be equipped with up to a maximum of 2 pumps. With 100% heat recovery or desuperheater accessories, the PUMP unit is not foreseen. Requests for different configurations can be made to the company.

… Absorbed power TCHEY

kW

2115

2130

2145

2165

2185

9,65

11,16

12,89

14,73

16,16

18,78

21,98

25,18

28,47

31,31

36,42

41,27

… E.E.R. TCHEY

4,69

4,78

4,70

4,69

4,70

4,80

4,69

4,66

4,60

4,65

4,54

4,48

O E.S.E.E.R.

6,67

6,73

6,78

6,52

6,63

6,45

6,32

6,30

6,16

6,14

6,14

5,97

- E.S.E.E.R.+

7,54

7,62

7,68

7,39

7,42

7,23

7,10

7,08

6,91

6,89

6,91

6,71

† Heating capacity THHEY

kW

50,00

58,84

67,59

75,41

83,66

101,76

116,26

133,25

147,33

162,82

186,13

208,84

† Absorbed power

kW

12,03

13,72

15,66

17,42

19,55

23,41

27,13

31,04

34,89

38,90

45,21

51,33

†C.O.P.

4,16

4,29

4,32

4,33

4,28

4,35

4,29

4,29

4,22

4,19

4,12

4,07

E.E.R. (**)

5,66

5,68

5,60

5,61

5,47

5,36

5,43

5,52

5,52

5,58

5,61

5,40

C.O.P. (**)

5,55

5,60

5,53

5,56

5,56

5,41

5,31

5,37

5,23

5,26

5,17

5,10

dB(A)

67

67

68

68

69

70

71

72

73

74

74

75

No.

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

No.

1

1

1

1

1

1

1

1

1

1

1

1

‡ Sound power level Scroll/step compressor Circuits Main supply

V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 245

250

260

270

275

290

2100

2115

2130

2145

2165

2185

ˆW - Width

mm

1.000

1.000

1.000

1.000

1.000

1.000

1.250

1.250

1.250

1.250

1.250

1.250

‰W - Width

mm

1.250

1.250

1.250

1.250

1.250

1.250

1.500

1.500

1.500

1.500

1.500

1.500

H - Height

mm

1.400

1.400

1.400

1.400

1.400

1.400

1.550

1.550

1.550

1.550

1.550

1.550

D - Depth

mm

870

870

870

870

870

870

870

870

870

870

870

870

DIMENSIONS AND WEIGHTS

4180

TCHEY-THHEY MODEL

P R E L I M I N A R Y

2100

103,1/96,2 117,3/109,5 131,0/121,1 145,7/134,8 165,5/152,7 184,8/170,6

4205

4235

4260

4290

4330

4360

4410

4450

… Cooling capacity TCHEY/THHEY

kW 181,4/161,0 207,4/184,2 233,2/207,3 260,9/232,2 288,4/256,1 327,1/290,9 364,4/324,9 408,7/364,2 450,8/402,5

… Absorbed power TCHEY

kW

37,00

42,30

47,58

53,42

59,20

68,32

77,68

89,24

101,20

… E.E.R. TCHEY

4,90

4,90

4,90

4,88

4,87

4,79

4,69

4,58

4,45

O E.S.E.E.R.

6,00

6,20

6,36

6,35

6,34

6,26

6,11

5,87

5,50

- E.S.E.E.R.+

6,78

7,03

7,19

7,12

7,13

7,07

6,94

6,63

6,16

† Heating capacity THHEY

kW

201,28

229,88

258,02

290,86

322,44

367,46

411,96

462,16

512,72

† Absorbed power

kW

43,36

50,54

57,62

64,74

71,72

82,96

94,14

107,40

120,82

†C.O.P.

4,64

4,55

4,48

4,49

4,50

4,43

4,38

4,30

4,24

E.E.R. (**)

5,78

5,74

5,71

5,66

5,58

5,40

5,31

5,15

4,99

C.O.P. (**)

5,98

5,83

5,70

5,68

5,64

5,55

5,42

5,27

5,12

dB(A)

77

77

78

79

80

81

82

83

84

No.

4/4

4/4

4/4

4/4

4/4

4/4

4/4

4/4

4/4

No.

2

2

2

2

2

2

2

2

2

‡ Sound power level Scroll/step compressor Circuits Main supply

V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 4180

4205

4235

4260

4290

4330

4360

4410

4450

ˆW - Width

mm

-

-

-

-

-

-

-

-

-

ˆW - Width

mm

-

-

-

-

-

-

-

-

-

H - Height

mm

-

-

-

-

-

-

-

-

-

D - Depth

mm

-

-

-

-

-

-

-

-

-

DIMENSIONS AND WEIGHTS

In the following conditions: … Chilled water: 7/12°C. - Condenser water: 30/35°C. † Hot water: 40/45°C. - Evaporator water: 10°C. - Water flow rate as in summer operation. ‡ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ˆ Width refers to the unit with standard installation or with "recovery" or "desuperheater" accessories. ‰ Width refers to the unit with a PUMP installation up to a maximum of 2 pumps (2 pumps user side or disposal unit side or 1 user side pump + 1 disposal unit side pump). O ESEER (European Seasonal EER) - Average European seasonal efficiency. - ESEER with Adaptive Function Plus software. (***) Energy ratings calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market.

AIR cooled AXIAL fans

90,1/82,3

AIR cooled CENTRIFUGAL fans

75,9/69,4

WATER cooled CONDENSERLESS UNITS

290

69,2/63,2

WATER CHILLERS HEAT PUMPS

275

60,6/55,4

WATER CHILLERS HEAT PUMPS

270

53,3/48,7

INDUSTRIAL & PROCESS COOLING

260

45,2/41,4

EXP Polyvalent systems

250

kW

CONDENSING UNITS

245

… Cooling capacity TCHEY/THHEY

SYSTEM ACCESSORIES

TCHEY-THHEY MODEL

WATER CHILLERS HEAT PUMPS

65

INDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

Z-Flow Range 66

TCHVZ 1201÷31631 H.E.

GREEN LINE

Cooling capacity: 204÷1,635 kW

• Efficiency range in CLASS A with EER >5.05 • 33 sizes up to more than 1,600 kW • Wide range of standard equipment TCHVBZ 31631 H.E.

Packaged water-cooled water chillers. Range with semihermetic screw compressors and R134a refrigerant gas. Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Water side heat exchanger (condenser): shell and tube complete with safety valve, and service valve on the high-pressure refrigerant circuit. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating.

Versions • B -Standard version (TCHVBZ). • I -Soundproofed version with soundproofed compressor cover (TCHVIZ).

Models • TCHVBZ: unit designed for cooling only. • TCHVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • Prepared for heat pump function. • Power factor correction capacitors (cosφ > 0.94). • Thermal overload switches • Inlet compressor shut-off valves • Linear capacity control compressors (50-100 % for each compressor). • Evaporator antifreeze electric heater. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 0-10V analogue input for condensation control performed by external device. • 4-20 mA analogue input for shifting set-point. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Antivibration rubber mountings. • Clock card • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

mm mm mm kg kg

kW

kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg

kW

kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg

1611 608 5,06 6,03 120,3 98 96 1/3 1 400-3-50 1611 3.450 1.740 1.000 2.697 2.952

2411 407 5,06 5,93 80,5 97 95 2/6 2 400-3-50 2411 3.880 1.840 1.300 2.386 2.816

2431 435 5,06 5,85 86,0 97 95 2/6 2 400-3-50 2431 3.880 1.840 1.300 2.413 2.843

2461 462 5,05 5,82 91,4 97 95 2/6 2 400-3-50 2461 4.000 1.840 1.300 2.458 2.888

2511 514 5,05 5,85 101,9 99 97 2/6 2 400-3-50 2511 4.070 1.960 1.300 2.953 3.383

2561 565 5,06 5,99 111,7 99 97 2/6 2 400-3-50 2561 4.070 1.960 1.300 3.297 3.727

2601 599 5,07 6,01 118,1 99 97 2/6 2 400-3-50 2601 4.070 1.960 1.300 3.320 3.750

2631 629 5,06 5,98 124,3 99 97 2/6 2 400-3-50 2631 4.070 1.960 1.300 3.337 3.767

2681 677 5,08 5,90 133,4 99 97 2/6 2 400-3-50 2681 4.070 1.960 1.300 3.404 3.834

2711 715 5,05 5,88 141,6 99 97 2/6 2 400-3-50 2711 4.070 1.960 1.300 3.447 3.877

2781 778 5,06 5,86 153,8 99 97 2/6 2 400-3-50 2781 4.120 1.840 1.300 3.920 4.350 31301 1.308 5,20 6,06 251,6 101 99 3/9 3 400-3-50 31301 4.940 2.220 1.700 6.795 7.395

In the following conditions: … Chilled water: 7/12°C. - Condenser inlet water: 30/35°C. ‡ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Empty weight.

2841 839 5,05 5,89 166,1 99 97 2/6 2 400-3-50 2841 4.000 1.840 1.300 4.406 4.836 31351 1.356 5,15 6,01 263,4 101 99 3/9 3 400-3-50 31351 4.940 2.220 1.700 6.827 7.427

2901 901 5,05 6,03 178,4 99 97 2/6 2 400-3-50 2901 4.000 1.910 1.300 4.636 5.066

2961 958 5,05 5,99 189,8 99 97 2/6 2 400-3-50 2961 4.000 1.910 1.300 4.669 5.099

31401 1.406 5,11 6,05 275,1 101 99 3/9 3 400-3-50 31401 4.940 2.220 1.700 6.852 7.452

21031 1.029 5,07 5,98 203 99 97 2/6 2 400-3-50 21031 4.000 1.950 1.300 4.779 5.209

31461 1.463 5,10 6,00 286,8 102 100 3/9 3 400-3-50 31461 4.940 2.220 1.700 6.891 7.491

21111 1.109 5,16 6,02 215 99 97 2/6 2 400-3-50 21111 4.000 1.950 1.300 4.870 5.300 31521 1.524 5,11 6,02 298,3 102 100 3/9 3 400-3-50 31521 4.940 2.220 1.700 6.980 7.580

21181 1.181 5,19 5,98 227,5 99 97 2/6 2 400-3-50 21181 4.000 1.950 1.300 5.008 5.438 31591 1.583 5,12 6,01 309,2 102 100 3/9 3 400-3-50 31591 4.940 2.220 1.700 7.068 7.668

O ESEER (European Seasonal EER) - Average European seasonal efficiency. Q TCHVIZ soundproofed version.

21261 1.258 5,20 5,97 242 99 97 2/6 2 400-3-50 21261 4.000 1.950 1.300 4.934 5.364 31631 1.635 5,11 6,02 320,1 102 100 3/9 3 400-3-50 31631 4.940 2.220 1.700 7.157 7.757

AIR cooled AXIAL fans

1531 535 5,05 5,83 105,9 98 96 1/3 1 400-3-50 1531 3.450 1.740 1.000 2.662 2.917

AIR cooled CENTRIFUGAL fans

1481 480 5,05 5,87 95,0 97 95 1/3 1 400-3-50 1481 3.450 1.640 1.000 2.413 2.668

WATER cooled CONDENSERLESS UNITS

1421 418 5,05 6,01 82,8 97 95 1/3 1 400-3-50 1421 3.450 1.640 1.000 2.374 2.629

WATER CHILLERS HEAT PUMPS

1351 354 5,05 6,00 70,1 97 95 1/3 1 400-3-50 1351 3.450 1.640 1.000 1.885 2.140

WATER CHILLERS HEAT PUMPS

kW dB(A) dB(A) No. No. V-ph-Hz

1311 309 5,05 5,80 61,1 97 95 1/3 1 400-3-50 1311 3.440 1.460 1.000 1.733 1.988

INDUSTRIAL & PROCESS COOLING

kW

1281 283 5,07 5,84 55,9 97 95 1/3 1 400-3-50 1281 3.440 1.460 1.000 1.715 1.970

EXP Polyvalent systems

mm mm mm kg kg

1231 231 5,05 5,83 45,7 94 92 1/3 1 400-3-50 1231 3.460 1.460 1.000 1.369 1.624

CONDENSING UNITS

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

kW dB(A) dB(A) No. No. V-ph-Hz

1201 204 5,06 6,00 40,4 94 92 1/3 1 400-3-50 1201 3.460 1.460 1.000 1.343 1.598

SYSTEM ACCESSORIES

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

kW

FAN COIL UNITS

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

WATER CHILLERS HEAT PUMPS

67

INDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Z-Flow Range 68

TCHVZ 1200÷31630 Cooling capacity: 199,7÷1.629,2 kW

• Efficiency range with EER >4.75 • 33 sizes up to more than 1,600 kW • Heat pump unit with water production up to 55°C

Packaged water-cooled water chillers. Range with semihermetic screw compressors and R134a refrigerant gas. Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Water side heat exchanger (condenser): shell and tube complete with safety valve, and service valve on the high-pressure refrigerant circuit. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating.

Versions • B -Standard version (TCHVBZ). • I -Soundproofed version with soundproofed compressor cover (TCHVIZ).

Models • TCHVBZ: unit designed for cooling only. • TCHVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES • Desuperheater. • 100% heat recovery. • Thermostat with display for the heat recovery/desuperheater. • Prepared for heat pump function. • Power factor correction capacitors (cosφ > 0.94). • Thermal overload switches • Inlet compressor shut-off valves • Linear capacity control compressors (50-100 % for each compressor). • Evaporator antifreeze electric heater. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Compressor oil level sensor. • Control of min/max power supply voltage. • 0-10V analogue input for condensation control performed by external device. • 4-20 mA analogue input for shifting set-point. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Antivibration rubber mountings. • Clock card • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

mm mm mm kg kg

kW

kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg

kW

kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg

1590 589,3 4,92 6,00 119,8 98 96 1/3 1 400-3-50 1590 3.450 1.740 1.000 2.687 2.942

2400 391,7 4,90 5,70 80,0 97 95 2/6 2 400-3-50 2400 3.880 1.840 1.300 2.366 2.796

2420 413,0 4,81 5,68 85,8 97 95 2/6 2 400-3-50 2420 3.880 1.840 1.300 2.393 2.823

2440 432,0 4,75 5,60 91,0 97 95 2/6 2 400-3-50 2440 4.000 1.840 1.300 2.438 2.868

2510 506,8 4,80 5,68 105,6 99 97 2/6 2 400-3-50 2510 4.070 1.960 1.300 2.923 3.353

2560 550,8 4,94 5,93 111,5 99 97 2/6 2 400-3-50 2560 4.070 1.960 1.300 3.257 3.687

2600 592,0 4,92 5,95 120,3 99 97 2/6 2 400-3-50 2600 4.070 1.960 1.300 3.280 3.710

2630 621,6 4,93 5,83 126,1 99 97 2/6 2 400-3-50 2630 4.070 1.960 1.300 3.297 3.227

2680 676,8 4,93 5,73 137,3 99 97 2/6 2 400-3-50 2680 4.070 1.960 1.300 3.364 3.794

2710 709,8 4,93 5,71 144,1 99 97 2/6 2 400-3-50 2710 4.070 1.960 1.300 3.407 3.837

2750 742,0 4,88 5,69 152,0 99 97 2/6 2 400-3-50 2750 4.120 1.840 1.300 3.880 4.310 31300 1.282,9 4,98 6,00 257,7 101 99 3/9 3 400-3-50 31300 4.940 2.220 1.700 6.735 7.335

In the following conditions: … Chilled water: 7/12°C. - Condenser inlet water: 30/35°C. ‡ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Empty weight.

2790 787,0 4,83 5,72 162,8 99 97 2/6 2 400-3-50 2790 4.000 1.840 1.300 4.366 4.796 31350 1.330,0 4,93 5,89 270,0 101 99 3/9 3 400-3-50 31350 4.940 2.220 1.700 6.767 7.367

2880 879,1 4,92 5,98 178,7 99 97 2/6 2 400-3-50 2880 4.000 1.910 1.300 4.596 5.026

2930 927,2 4,81 5,82 192,8 99 97 2/6 2 400-3-50 2930 4.000 1.910 1.300 4.629 5.059

31390 1.377,2 4,87 5,87 282,9 101 99 3/9 3 400-3-50 31390 4.940 2.220 1.700 6.792 7.392

21030 1.016,6 4,84 5,81 210,0 99 97 2/6 2 400-3-50 21030 4.000 1.950 1.300 4.739 5.169

31460 1.437,5 4,87 5,83 295,4 102 100 3/9 3 400-3-50 31460 4.940 2.220 1.700 6.831 7.431

21110 1.087,3 4,88 5,96 222,8 99 97 2/6 2 400-3-50 21110 4.000 1.950 1.300 4.830 5.260 31520 1.518,5 4,91 5,90 309,0 102 100 3/9 3 400-3-50 31520 4.940 2.220 1.700 6.920 7.520

21180 1.155,8 4,92 5,86 2,34,9 99 97 2/6 2 400-3-50 21180 4.000 1.950 1.300 4.878 5.308 31590 1.580,8 4,91 5,89 321,7 102 100 3/9 3 400-3-50 31590 4.940 2.220 1.700 7.008 7.608

O ESEER (European Seasonal EER) - Average European seasonal efficiency. Q TCHVIZ soundproofed version.

21260 1.208,4 4,87 5,85 248,0 99 97 2/6 2 400-3-50 21260 4.000 1.950 1.300 4.914 5.344 31630 1.629,2 4,87 5,90 334,2 102 100 3/9 3 400-3-50 31630 4.940 2.220 1.700 7.097 7.697

AIR cooled AXIAL fans

1530 524,9 4,90 5,72 107,2 98 96 1/3 1 400-3-50 1530 3.450 1.740 1.000 2.642 2.897

AIR cooled CENTRIFUGAL fans

1460 462,4 4,90 5,75 94,3 97 95 1/3 1 400-3-50 1460 3.450 1.640 1.000 2.393 2.648

WATER cooled CONDENSERLESS UNITS

1410 404,6 4,93 5,89 82,1 97 95 1/3 1 400-3-50 1410 3.450 1.640 1.000 2.354 2.609

WATER CHILLERS HEAT PUMPS

1350 347,6 4,93 5,97 70,5 97 95 1/3 1 400-3-50 1350 3.450 1.640 1.000 1.865 2.120

WATER CHILLERS HEAT PUMPS

kW dB(A) dB(A) No. No. V-ph-Hz

1310 306,3 4,89 5,69 62,7 97 95 1/3 1 400-3-50 1310 3.440 1.460 1.000 1.713 1.968

INDUSTRIAL & PROCESS COOLING

kW

1280 277,3 4,91 5,73 56,5 97 95 1/3 1 400-3-50 1280 3.440 1.460 1.000 1.695 1.950

EXP Polyvalent systems

mm mm mm kg kg

1230 226,3 4,92 5,72 46,0 94 92 1/3 1 400-3-50 1230 3.460 1.460 1.000 1.359 1.614

CONDENSING UNITS

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

kW dB(A) dB(A) No. No. V-ph-Hz

1200 199,7 4,93 5,97 40,5 94 92 1/3 1 400-3-50 1200 3.460 1.460 1.000 1.333 1.588

SYSTEM ACCESSORIES

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

kW

FAN COIL UNITS

TCHVBZ-TCHVIZ MODEL … Nominal cooling capacity … E.E.R. O E.S.E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCHVBZ ‰ Weight TCHVIZ

WATER CHILLERS HEAT PUMPS

69

INDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Mini-Q Flow E Range (mod. 105-115) - Compact Flow E Range (mod. 120-165) - Q-Flow E Range (mod. 280-4260) 70

TCEE 105÷4260 Cooling capacity: 5.5÷249 kW

Cooling-only condenserless units to be connected to CCAM remote condensers. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Water side heat exchanger: stainless steel plate exchanger complete with water flow differential pressure switch. • Control: microprocessor electronic control. • Structure: in galvanised and polyester powder coated sheet steel, complete with soundproofed compressor (for mod. 105-165).For mod. 280-4260, the unit is also complete with: - high and low pressure gauges complete with capillaries.

Versions • B -Standard version (TCEEB). • I - Soundproofed version with soundproofed compressor cover (TCCEI) for models 280-4260.

Models • TCEEB: unit designed for cooling only. • TCCEI: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES • Modulating condensation control (in combination with CCAM only). • Refrigerant circuit high and low pressure gauges (for models 105-165 only).

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • Remote keyboard with display. • Serial interface for connection to BMS (proprietary protocol, Modbus RTU). • RS 485/RS232 serial converter in the event of centralised unit management. • CCAM remote condensers. • Pumping group with PBHI buffer tank (for models 155-165 and 280-4260 only).

Main supply

155

165

37,1

50,2

62,2

3,30

3,58

3,52

3,58

3,68

3,74

3,40

3,49

2,0

4,1

6,0

8,4

10,8

12,7

17,1

20,8

dB(A)

51

57

60

64

67

68

71

72

No.

1/1

1/1

1/1

1/1

1/1

1/1

1/1

1/1

No.

1

1

1

1

1

1

1

1

V-ph-Hz

230-1-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

DIMENSIONS AND WEIGHTS

105

115

120

125

135

140

155

165

W - Width

mm

750

750

750

750

750

750

987

987

H - Height

mm

869

869

869

869

869

869

869

869

D - Depth

mm

615

615

615

615

615

615

636

636

kg

154

172

211

224

247

270

490

505

280

2110

2130

4160

4190

4220

4240

4260

kW

74,2

100,4

124,5

148,4

174,6

200,8

224,9

249,0

3,47

3,44

3,51

3,47

3,46

3,44

3,48

3,51

kW

25,4

34,2

41,7

50,8

59,6

68,4

75,9

83,4

† Sound power level

dB(A)

71

74

75

76

78

79

80

80

† Sound power level

dB(A)

69

72

73

74

76

77

78

78

Scroll/step compressor

No.

2

2

2

4

4

4

4

4

Circuits

No.

1

1

1

2

2

2

2

2

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

280

2110

2130

4160

4190

4220

4240

4260

W - Width

mm

1.214

1.214

1.214

2.407

2.407

2.407

2.407

2.407

H - Height

mm

1.703

1.703

1.703

1.079

1.709

1.709

1.709

1.709

D - Depth

mm

873

873

873

873

873

873

873

873

kg

645

790

808

906

1.015

1.121

1.140

1.157

TCEEB-TCEEI MODEL … Nominal cooling capacity … E.E.R. … Absorbed power

Main supply DIMENSIONS AND WEIGHTS

Weight TCEE

Q TCEEI soundproofed version.

In the following conditions: …Chilled water: 12/7°C - Dew point: 50°C. † Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‡ At 10 m from the unit in free field (Q = 2).

CONDENSING UNITS

Weight TCEEB

Recommended combinations with CCAM remote condensers TCEEB MODEL

105

115

120

125

135

140

155

165





120 N

125 N

135 N

140 N

155 N

165 N

CCAM MODEL Version N “Normal” ‡ Sound pressure level CCAM MODEL Version S “Silenced” ‡ Sound pressure level CCAM MODEL Version Q “Supersilenced” ‡ Sound pressure level TCEEB-TCEEI MODEL CCAM MODEL Version N “Normal” ‡ Sound pressure level CCAM MODEL Version S “Silenced” ‡ Sound pressure level CCAM MODEL Version Q “Supersilenced” ‡ Sound pressure level





43

44

46

46

48

49

105 S

115 S

120 S

125 S

135 S

140 S

155 S

165 S

36

34

37

37

39

46

46

47

105 Q

115 Q

120 Q

125 Q

135 Q

140 Q

155 Q

165 Q

29

32

32

35

37

35

40

38

280 280 N 59

2110 2110 N 61

2130 2130 N 61

280 S

2110 S

2130 S

52

49

49

280 Q

2110 Q

2130 Q

46

43

45

(*) Each model must be combined with two condensers (one per circuit) from the CCAM range.

Circuiti

4160(*)

4190(*)

4220(*)

4240(*)

(1)

280 N

280 N

2110 N

2110 N

4260(*) 2130 N

(2)

280 N

2110 N

2110 N

2130 N

2130 N

(1/2)

59/59

59/61

61/61

61/61

61/61

(1)

280 S

280 S

2110 S

2110 S

2130 S 2130 S

(2)

280 S

2110 S

2110 S

2130 S

(1/2)

52/52

52/49

49/49

49/49

49/49

(1)

280 Q

280 Q

2110 Q

2110 Q

2130 Q

(2)

280 Q

2110 Q

2110 Q

2130 Q

2130 Q

(1/2)

46/46

46/43

43/43

43/45

45/45

AIR cooled AXIAL fans

140

31,8

AIR cooled CENTRIFUGAL fans

Circuits

135

24,3

WATER cooled CONDENSERLESS UNITS

Scroll/step compressor

125

17,2

WATER CHILLERS HEAT PUMPS

† Sound power level

kW

120

11,6

WATER CHILLERS HEAT PUMPS

… Absorbed power

115

5,5

INDUSTRIAL & PROCESS COOLING

… E.E.R.

105

EXP Polyvalent systems

kW

SYSTEM ACCESSORIES

… Nominal cooling capacity

FAN COIL UNITS

TCEEB MODEL

WATER CHILLERS HEAT PUMPS

71

INDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Z-Flow E Range 72

TCEVZ 1200÷31630 Cooling capacity: 171,9÷1.424,8 kW

• Efficient condenserless units in R134a • 33 sizes in the standard and soundproofed versions • Wide range of standard equipment Cooling-only conderserless units. Range with semi-hermetic screw compressors and R134a refrigerant gas. Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-off valve. • Electronic expansion valve: as standard on all models. • Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating.

Versions • B - Standard version (TCEVBZ). • I -Soundproofed version with soundproofed compressor cover (TCEVIZ).

Models • TCEVBZ: unit designed for cooling only. • TCEVIZ: soundproofed unit designed for cooling only.

FACTORY FITTED ACCESSORIES • Power factor correction capacitors (cosφ > 0.94). • Thermal overload switches • Inlet compressor shut-off valves • Linear capacity control compressors (50-100 % for each compressor). • Evaporator antifreeze electric heater. • Digital input for double set-point • Compressor oil level sensor. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Antivibration rubber mountings. • Clock card • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

TCEVBZ-TCEVIZ MODEL … Nominal cooling capacity … E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCEVBZ ‰ Weight TCEVIZ

mm mm mm kg kg

kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg

kW kW dB(A) dB(A) No. No. V-ph-Hz mm mm mm kg kg

1590 508,9 3,4 149,7 98 96 1/3 1 400-3-50 1590 3.460 1.740 1.000 2.281 2.536

2400 335,8 3,3 100,7 97 95 2/6 2 400-3-50 2400 3.870 1.490 1.300 1.797 2.227

2420 356,6 3,3 108,3 97 95 2/6 2 400-3-50 2420 3.870 1.490 1.300 1.811 2.241

2440 372,1 3,2 115,7 97 95 2/6 2 400-3-50 2440 3.870 1.490 1.300 1.819 2.249

2510 431,9 3,3 130,6 99 97 2/6 2 400-3-50 2510 4.070 1.610 1.300 2.311 2.741

2560 473,4 3,3 144,4 99 97 2/6 2 400-3-50 2560 4.070 1.610 1.300 2.629 3.059

2600 506,4 3,3 151,5 99 97 2/6 2 400-3-50 2600 4.070 1.610 1.300 2.637 3.067

2630 529,3 3,3 158,4 99 97 2/6 2 400-3-50 2630 4.070 1.610 1.300 2.638 3.068

2680 581,4 3,5 168,0 99 97 2/6 2 400-3-50 2680 4.070 1.610 1.300 2.698 3.128

2710 614,1 3,5 176,6 99 97 2/6 2 400-3-50 2710 4.070 1.610 1.300 2.733 3.163

2750 647,8 3,4 192,1 99 97 2/6 2 400-3-50 2750 4.120 1.490 1.300 3.176 3.606 31300 1.129,6 3,6 314,1 101 99 3/9 3 400-3-50 31300 4.940 1.620 2.000 5.555 6.155

In the following conditions: … Chilled water: 12/7°C - Dew point: 50°C. ‡ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744. ‰ Weight of fully accessorised unit when empty.

2790 681,6 3,3 207,6 99 97 2/6 2 400-3-50 2790 4.000 1.490 1.300 3.631 4.061 31350 1.178,3 3,6 331,8 101 99 3/9 3 400-3-50 31350 4.940 1.620 2.000 5.570 6.170

2880 753,9 3,3 226,5 99 97 2/6 2 400-3-50 2880 4.000 1.560 1.300 3.844 4.272

2930 801,4 3,3 244,4 99 97 2/6 2 400-3-50 2930 4.000 1.560 1.300 3.859 4.289

31390 1.227,0 3,5 349,5 101 99 3/9 3 400-3-50 31390 4.940 1.620 2.000 5.585 6.185

21030 896,1 3,5 257,9 99 97 2/6 2 400-3-50 21030 4.000 1.600 1.300 3.936 4.366

31460 1.287,5 3,5 367,1 102 100 3/9 3 400-3-50 31460 4.940 1.620 2.000 5.600 6.200

Q TCEVIZ soundproofed version.

21110 959,4 3,5 271,0 99 97 2/6 2 400-3-50 21110 4.000 1.600 1.300 3.993 4.423 31520 1.340,1 3,5 380,4 102 100 3/9 3 400-3-50 31520 4.940 1.620 2.000 5.678 6.278

21180 1.027,8 3,6 285,5 99 97 2/6 2 400-3-50 21180 4.000 1.600 1.300 4.024 4.454 31590 1.388,5 3,5 393,4 102 100 3/9 3 400-3-50 31590 4.940 1.620 2.000 5.710 6.310

21260 1.101,5 3,7 299,4 99 97 2/6 2 400-3-50 21260 4.000 1.600 1.300 4.044 4.474 31630 1.424,8 3,5 406,4 102 100 3/9 3 400-3-50 31630 4.940 1.620 2.000 5.790 6.390

AIR cooled AXIAL fans

1530 446,4 3,3 135,3 98 96 1/3 1 400-3-50 1530 3.460 1.740 1.000 2.252 2.507

AIR cooled CENTRIFUGAL fans

1460 399,7 3,3 122,2 97 95 1/3 1 400-3-50 1460 3.450 1.640 1.000 2.038 2.293

WATER cooled CONDENSERLESS UNITS

1410 346,2 3,3 104,0 97 95 1/3 1 400-3-50 1410 3.450 1.640 1.000 2.032 2.287

WATER CHILLERS HEAT PUMPS

1350 300,6 3,4 88,1 97 95 1/3 1 400-3-50 1350 3.450 1.640 1.000 1.557 1.812

WATER CHILLERS HEAT PUMPS

kW dB(A) dB(A) No. No. V-ph-Hz

1310 260,4 3,3 79,0 97 95 1/3 1 400-3-50 1310 3.440 1.460 1.000 1.414 1.669

INDUSTRIAL & PROCESS COOLING

kW

1280 238,1 3,3 72,2 97 95 1/3 1 400-3-50 1280 3.420 1.460 1.000 1.410 1.665

EXP Polyvalent systems

mm mm mm kg kg

1230 190,8 3,3 58,1 94 92 1/3 1 400-3-50 1230 3.440 1.460 1.000 1.093 1.348

CONDENSING UNITS

TCEVBZ-TCEVIZ MODEL … Nominal cooling capacity … E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCEVBZ ‰ Weight TCEVIZ

kW dB(A) dB(A) No. No. V-ph-Hz

1200 171,9 3,4 50,5 94 92 1/3 1 400-3-50 1200 3.440 1.460 1.000 1.078 1.333

SYSTEM ACCESSORIES

TCEVBZ-TCEVIZ MODEL … Nominal cooling capacity … E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCEVBZ ‰ Weight TCEVIZ

kW

FAN COIL UNITS

TCEVBZ-TCEVIZ MODEL … Nominal cooling capacity … E.E.R. … Absorbed power ‡ Sound power level ‡ Sound power level Screw compressor/steps Circuits Main supply DIMENSIONS AND WEIGHTS W - Width H - Height D - Depth ‰ Weight TCEVBZ ‰ Weight TCEVIZ

WATER CHILLERS HEAT PUMPS

73

INDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Industrial & Process Cooling Range 74

INDUSTRIAL line

A complete range in R410A for industrial applications. • An industrial application is different from comfort installations due to some specific requirements that are fulfilled by the new range in R410A. • The models were designed to permit maximum flexibility of use, guarantee the production of chilled water between –10°C and 20°C and offer a wide range of accessories to meet the various installation needs. • The design pays scrupulous attention to the technical and constructive details of industrial installations in unpressurised systems. • The applications for which this range is best suited

include plastic & rubber processing, the food sector, the chemical and pharmaceutical industries and the electronic and automobile sectors. • All models in the industrial range are equipped with the exclusive Adaptive Function Plus software, in addition to the system's advantages, and ensure that the temperature of the water delivered to the system will be stable also at a partial load. • Thanks to its performance, the range is Eurovent and ECA certified (Enhanced Capital Allowances).

Industrial & Process Cooling Range

WINE line

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING

processes is not only represented by the obtainment of fine wines, but also by the limiting of energy consumption. With RHOSS's technology applied to the chillers, the thermo-ventilating units and the air handling units, it is possible to reduce production and management costs and protect the environment.

EXP Polyvalent systems

1300

CONDENSING UNITS

• The transformation of the best grapes into excellent wines is no longer only entrusted to oenologists. Technology has become a mandatory partner in wine's productive cycle. • The new WINE range of chillers specifically studied by RHOSS makes it possible to carefully and delicately control the temperature, humidity and thermal exchanges in order to optimise and improve the production of the must and its fermentation, for the subsequent evolution and refinement of the wine. • The final success achieved with these productive

75

SYSTEM ACCESSORIES

RHOSS technology at the service of tradition for a superior result and guaranteed savings.

60

FAN COIL UNITS

5

TERMINAL UNITS

kW

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

75

Industrial & Process Cooling Range 76

TCAEY 118÷2189

GREEN LINE

Cooling capacity: 15.4÷161.9 kW

• Efficient and flexible industrial range in R410A • 17 sizes for open circuits • Wide range of standard equipment and accessories

Packaged air cooled water chillers with axial fans. Range with hermetic Scroll compressors and R410A refrigerant. Construction features The units are made to operate on open circuits. • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater (mod. 135-2189). 2 or 3 capacity steps with high efficiency at partial loads (mod. 2532189). • Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. • Air side heat exchanger: finned coil with copper pipes and aluminium fins, complete with metal protection filters. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control with Adaptive Function Plus logic. • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - compressor and fan thermal overload switches.

Models • TCAEY: unit designed for cooling only.

STANDARD unit (for mod. 279÷2189 only) Without pumping group and buffer tank.

FACTORY FITTED ACCESSORIES • PUMP (models 279÷2189) with single or double pump, including an automatic pump in standby, complete with air bleed valve, water side pressure gauge, level indicator and top-up from above.

The pumps are available in the low or high pressure versions. • TANK&PUMP with inertial water buffer tank, complete with antifreeze electric heater and single or double pump, including an automatic pump in standby (for mod. 253-2189 only), air bleed valves, water side pressure gauge, level indicator and top-up from above. Depending on the models, the pumps are available in low or high pressure versions. • NON FERROUS option (mod. 279÷2189) with pump and/or water buffer tank in stainless steel, copper and/or plastic pipes for demineralised water. • Chilled water production, down to –10°C (mod. 279-2189). • Crankcase heater compressor (mod. 118÷131). • Soft - start device (mod. 279÷2189). • Power factor correction capacitors (cosφ > 0.94) (mod. 279-2189). • Stainless steel metal filters for coil protection (mod. 279÷2189). • Refrigerant circuit high and low pressure gauges (mod. 279-2189). • Pump antifreeze heaters (mod. 279÷2189). • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

2,76

2,67

2,76

2,62

2,50

2,56

2,55

2,60

2,68

O E.S.E.E.R.

3,15

3,11

3,44

3,09

2,89

2,85

3,78

4,31

4,38

… Absorbed power (*)

kW

5,6

6,5

8,2

9,3

11,8

13,3

17,4

19,7

22,1

† Nominal cooling capacity

kW

18,6

21,0

27,7

29,3

34,7

40,5

53,2

61,1

70,5

3,85

3,73

3,88

3,69

3,30

3,38

3,52

3,53

3,62

kW

4,8

5,6

7,1

7,9

10,5

11,7

15,0

17,3

19,4

‡ Sound pressure level

dB(A)

50,0

50,0

50,5

50,5

55,0

52,1

54,0

54,0

54,5

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

1/1

1/1

2/3

2/3

2/3

Circuits

No.

1

1

1

1

1

1

1

1

1

l

42

42

51

51

55

80

150

150

150

kPa

420

390

336

335

271

520

480

450

425

† E.E.R. † Absorbed power (*)

Water tank content † Available nominal head pressure of pump Main supply

V-ph-Hz 400-3+N-50

400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50

118

121

128

131

135

140

253

261

270

mm

510

510

510

510

610

1.710

2.315

2.315

2.315

H - Height

mm

1.305

1.305

1.505

1.505

1.740

1.570

1.570

1.570

1.570

D - Depth

mm

1.525

1.525

1.525

1.525

1.825

1.070

1.070

1.070

1.070

ˆ Weight

kg

230

240

290

300

390

470

645

660

680

DIMENSIONS AND WEIGHTS W - Width

279

299

2109

2119

2139

2149

2169

2189

64,5

79,7

88,5

101,0

115,3

126,9

145,0

161,9

… E.E.R.

2,91

2,99

2,90

2,91

2,92

2,90

2,90

2,90

O E.S.E.E.R.

3,52

3,64

3,48

3,52

3,53

3,48

3,49

3,48

TCAEY MODEL … Cooling capacity

kW

… Absorbed power (*)

kW

22,2

36,7

30,4

34,6

39,5

43,7

50,0

55,9

† Nominal cooling capacity

kW

75,6

93,5

104,0

119,2

136,0

149,8

170,8

190,9

† E.E.R.

3,92

4,03

3,90

3,91

3,88

3,87

3,86

3,86

kW

19,3

23,3

26,7

30,5

35,1

38,7

44,3

49,4

‡ Sound pressure level

dB(A)

50,0

51,0

52,0

52,0

55,0

55,0

56,0

56,0

Scroll/step compressor

No.

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

Circuits

No.

2

2

2

2

2

2

2

2

l

250

250

250

250

450

450

450

450

†Available nominal head pressure of P1 pump kPa

317

273

295

294

278

266

316

284

†Available nominal head pressure of P2 pump kPa

415

375

379

390

371

355

443

412

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

279

299

2109

2119

2139

2149

2169

2189

W - Width

mm

3.150

3.150

3.150

3.150

3.250

3.250

3.250

3.250

H - Height

mm

1.520

1.520

1.520

1.520

2.000

2.000

2.000

2.000

D - Depth

mm

1.210

1.210

1.210

1.210

1.520

1.520

1.520

1.520

ˆ Weight

kg

1.070

1.080

1.200

1.320

1.550

1.620

1.655

1.685

† Absorbed power (*)

Water tank content

Main supply DIMENSIONS AND WEIGHTS

In the following conditions: … Air: 35°C - Water: 7/12°C. †Air: 27°C - Water: 10/15°C. ‡ At 10 m from the unit in free field (Q = 2). ˆ The weight refers to the unit in its most complete form.

O ESEER (European Seasonal EER) - Average European seasonal efficiency. (*) Unit without pump.

AIR cooled AXIAL fans

… E.E.R.

AIR cooled CENTRIFUGAL fans

270 59,2

WATER cooled CONDENSERLESS UNITS

261 51,3

WATER CHILLERS HEAT PUMPS

253 44,2

WATER CHILLERS HEAT PUMPS

140 34,0

INDUSTRIAL & PROCESS COOLING

135 29,1

EXP Polyvalent systems

131 24,3

CONDENSING UNITS

128 22,7

SYSTEM ACCESSORIES

121 17,4

kW

FAN COIL UNITS

118 15,4

TCAEY MODEL … Cooling capacity

WATER CHILLERS HEAT PUMPS

77

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

78

GREEN LINE

EXP Polyvalent systems

kW 5

Polyvalent ecological system. Applications of EXPsystems • EXPsystems is the polyvalent ecological system designed by RHOSS to satisfy chilled and hot water demands simultaneously or independently with a single unit, according to the operating mode chosen, i.e. AUTOMATICor SELECT. It is designed for use in 2 and 4-pipe systems, at any time of year.

How does it work? • The evolved microprocessor control manages the two EXPsystems operating modes, AUTOMATIC and SELECT, catering to the demands of 2 or 4-pipe systems. - AUTOMATIC allows for the simultaneous or separate production of chilled and hot water, in a completely automatic fashion. - SELECT allows for the production of hot water and heating water on the basis of system demands and the priorities assigned by the user.

60

75

950

2-pipe systems • Air conditioning and the production of hot water in a 2-pipe system is a typical application in residential units, hotels, hospitals, gyms and hospitality structures in general. • EXPsystems in AUTOMATIC mode is used in the summer months for cooling and the production of hot water. • EXPsystems in SELECT mode is used in between seasons or in winter for heating and the production of hot water on the basis of the priority assigned.

4-pipe systems • Increasingly frequently, modern HVAC installations require the simultaneous production of hot and chilled water. This can occur more often because of: - the development of new types of thermal insulation for buildings; - increase in internal loads (CED, WEB, etc.); - lighting systems; - the presence of large windows; - the growing importance attributed to air quality, which requires the use of conditioning systems year-round. • In these types of EXPsystems application, it can be used in AUTOMATIC mode throughout the year, catering to simultaneous or separate hot and chilled water demands in a completely automatic manner.

COLD WATER

HOT WATER

HOT WATER

4-pipe systems AUTOMATIC mode for the entire year

Summer season

Mid season

cooling

cooling and heating

Winter months heating NORTH

CHILLED WATER

HOT WATER

CHILLED WATER

HOT WATER

CHILLED WATER

HOT WATER

AIR cooled AXIAL fans AIR cooled CENTRIFUGAL fans

TERMINAL UNITS

FAN COIL UNITS

SOUTH

SYSTEM ACCESSORIES

4

CONDENSING UNITS

EXP Polyvalent systems

HOT WATER

INDUSTRIAL & PROCESS COOLING

water

WATER cooled CONDENSERLESS UNITS

Winter season“SELECT”heating and hot water

Summer season“AUTOMATIC”coolingandhot

WATER CHILLERS HEAT PUMPS

2-pipe systems AUTOMATIC or SELECT mode

WATER CHILLERS HEAT PUMPS

2

WATER CHILLERS HEAT PUMPS

79

Compact-Y EXP Range 80

GREEN LINE

TXAEY 117÷133 Cooling capacity: 17.4÷34 kW - Heating capacity: 17.9÷39.1 kW

EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.

TANK&PUMP unit (for mod. 133 only)

Construction features

FACTORY FITTED ACCESSORIES

• Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Main and secondary heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. • Structure: in galvanised and painted sheet steel, complete with condensation drain pan.

• Silenced configuration. • Antifreeze electric heater on the buffer tank. • Unit base antifreeze electric heater for operation in heat pump mode at low external air temperatures (mod.117-130). • Protection coil grilles. • Single pump with increased head pressure (mod. 133). • Single pump with increased head pressure + buffer (mod. 133) • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

Models • TXAEY: standard EXPsystems unit.

STANDARD unit (for mod. 133 only) • Without pumping group and buffer tank.

PUMP unit • Pumping group for main circuit complete with: circulation pump, expansion tank with membrane, manual bleed valve and safety valve, pressure gauge.

• Pumping group for main circuit only complete with: water buffer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve and safety valve, pressure gauge.

ACCESSORIES SUPPLIED LOOSE • Protection coil grilles • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

… Nominal cooling capacity

124

130

133

kW

17,4

23,6

28,6

34,0

kW

20,8

30,4

37,2

44,2

kW

17,9

26,1

34,4

39,1

kW

6,4

9,4

11,7

13,3

kW

4,9

7,4

9,8

11,5

kW

6,1

8,9

11,1

13,3

6,62

6,72

6,13

6,25 54

(AUTOMATIC 1) ˆ Recovery heating capacity (AUTOMATIC 2) † Nominal heating capacity

AIR cooled AXIAL fans

117

TXAEY MODEL

WATER CHILLERS HEAT PUMPS

81

OUTDOOR INSTALLATION

(AUTOMATIC 2) † Absorbed power (*)

AIR cooled CENTRIFUGAL fans

ˆ Absorbed power (*)

WATER cooled CONDENSERLESS UNITS

(AUTOMATIC 1)

WATER CHILLERS HEAT PUMPS

… Absorbed power (*)

WATER CHILLERS HEAT PUMPS

(SELECT 1-2 AUTOMATIC 3)

dB(A)

50

52

53

‡ Silenced version sound pressure level

dB(A)

46

49

50

51

Scroll/step compressor

No.

1/1

1/1

1/1

1/1

Circuits

No.

1

1

1

1

l







80

Water tank content … Available head pressure of standard pump

kPa

130

131

110

134

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

117

124

130

133

mm

1.522

1.522

1.822

1.660

H - Height

mm

1.090

1.280

1.510

1.570

D - Depth

mm

580

600

695

1.000

kg

220

280

370

470

Main supply DIMENSIONS AND WEIGHTS W - Width

Weight TXAEY In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C.

2

Production of chilled or hot water for Summer or Winter air conditioning and/ or hot water for domestic use through EXPsystems units with air cooling (ex. residential environments).

TERMINAL UNITS

FAN COIL UNITS

2-pipe systems

‡ At 5 m from the unit in free field (Q = 2). ˆ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow. (*) Unit without pump.

EXP Polyvalent systems

‡ Sound pressure level

CONDENSING UNITS

(AUTOMATIC 2)

SYSTEM ACCESSORIES

ˆ C.O.P.

INDUSTRIAL & PROCESS COOLING

(SELECT 1-2 AUTOMATIC 3)

Compact-Y EXP Range 82

GREEN LINE

TXAEY 245÷265 Cooling capacity: 42.6÷61.9 kW - Heating capacity: 47.8÷67.9 kW

EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Main and secondary heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. • Structure: in galvanised and painted sheet steel.

Models • TXAEY: standard EXPsystems unit.

FACTORY FITTED ACCESSORIES • PUMP (for main circuit only) with single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valves, safety valve and water side pressure gauge.

The pumps are available in the low or high pressure versions. • TANK&PUMP (for main circuit only) with water buffer tank and single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. • Silenced configuration. • Refrigerant circuit high and low pressure gauges. • Protection coil grilles. • Antifreeze electric heater for buffer tank and pumps. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

ACCESSORIES SUPPLIED LOOSE • Protection coil grilles • Antivibration rubber mountings. • Water filter • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

250

260

265

kW

42,6

50,6

58,2

61,9

kW

54,4

65,0

71,8

81,1

kW

47,8

55,8

62,2

67,9

kW

16,8

18,5

21,6

24,0

kW

13,6

15,5

17,1

19,0

kW

16,6

18,6

20,5

23,3

6,94

7,30

7,32

7,48

‹ E.E.R. (EN 14511:2004)

3,36

3,34

3,39

3,44

‹ C.O.P. (EN 14511:2004)

3,93

3,94

3,93

3,97 57

… Nominal cooling capacity (AUTOMATIC 1) ˆ Recovery heating capacity (AUTOMATIC 2) † Nominal heating capacity

AIR cooled AXIAL fans

245

TXAEY MODEL

WATER CHILLERS HEAT PUMPS

83

OUTDOOR INSTALLATION

(AUTOMATIC 2) † Absorbed power (*)

AIR cooled CENTRIFUGAL fans

ˆ Absorbed power (*)

WATER cooled CONDENSERLESS UNITS

(AUTOMATIC 1)

WATER CHILLERS HEAT PUMPS

… Absorbed power (*)

WATER CHILLERS HEAT PUMPS

(SELECT 1-2 AUTOMATIC 3)

56

57

‡ Silenced version sound pressure level

dB(A)

53

53

54

54

No.

2/1

2/1

2/1

2/1

Scroll/step compressor

No.

1

1

1

1

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

245

250

260

265

mm

2.260

2.260

2.260

2.260

H - Height

mm

1.570

1.570

1.570

1.570

D - Depth

mm

1.000

1.000

1.000

1.000

kg

735

775

795

825

Circuits Main supply DIMENSIONS AND WEIGHTS W - Width

Weight TXAEY

In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C D.B. - 6°C W.B. - Water: 40/45°C. ‡ At 5 m from the unit in free field (Q = 2). ˆ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow.

‹Energy rates calculated in compliance with Standard EN 14511:2004, in the condition prescribed by the italian gouvernment (D.M. 7 August 2009). Only for italian market. (*) Unit without pump.

EXP Polyvalent systems

56

CONDENSING UNITS

dB(A)

SYSTEM ACCESSORIES

‡ Sound pressure level

FAN COIL UNITS

(AUTOMATIC 2)

TERMINAL UNITS

ˆ C.O.P.

INDUSTRIAL & PROCESS COOLING

(SELECT 1-2 AUTOMATIC 3)

Q-Pack EXP Range 84

GREEN LINE

TXAE 475÷4315 Cooling capacity: 70.4÷307 kW - Heating capacity: 71.4÷340 kW

TXAES 4150

EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with hermetic Scroll compressors and R407C refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Main and secondary heat exchangers: crossed-flow stainless steel plate exchangers, complete with closed cell polyurethane foam rubber insulation and water flow differential pressure switch. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment. • The unit is also complete with: - compressor and fan thermal overload switches.

Models • TXAEB: standard EXPsystems unit. • TXAES: silenced EXPsystems unit.

FACTORY FITTED ACCESSORIES • PUMP (for main circuit only) with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water side pressure gauge. The pumps are available in the low or high pressure versions. • TANK&PUMP (for main circuit only) with built-in buffer tank from 420 to 1,100 litres and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. • Power factor correction capacitors (cosφ > 0.91). • Refrigerant circuit high and low pressure gauges. • Metal filters or coil protection grilles. • Copper/copper, copper/tin-plated copper or copper/pre-painted aluminium coils. • Digital input for double set-point • 4-20 mA analogue input for shifting set-point. • Evaporator antifreeze heater, buffer tank, pumps and heat exchangers for heat recovery if present. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE Versions • B - Standard version complete with soundproofed compressor compartment (TXAEB). • S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TXAES).

• Antivibration rubber mountings. • Spring antivibration mountings (mod. 4200-4315). • Remote keyboard with display. • Clock card

… Nominal cooling capacity

495

4150

4200

4255

4315

kW

71,6

103,0

149,0

198,0

240,0

307,0

kW

91,7

132,7

198,8

260,4

320,4

409,3

kW

75,8

106,0

159,0

212,0

262,0

340,0

kW

26,2

36,3

58,2

75,9

94,1

122,0

kW

24,5

35,3

55,9

73,3

89,6

121,2

kW

28,0

38,7

57,4

79,9

96,0

124,0

6,48

6,52

6,11

6,10

6,15

5,75

(AUTOMATIC 1) ˆ Recovery heating capacity (AUTOMATIC 2) † Nominal heating capacity

AIR cooled AXIAL fans

475

 TXAEB MODEL

WATER CHILLERS HEAT PUMPS

85

OUTDOOR INSTALLATION

(AUTOMATIC 2) † Absorbed power

AIR cooled CENTRIFUGAL fans

ˆ Absorbed power

WATER cooled CONDENSERLESS UNITS

(AUTOMATIC 1)

WATER CHILLERS HEAT PUMPS

… Absorbed power

WATER CHILLERS HEAT PUMPS

(SELECT 1-2 AUTOMATIC 3)

kW

60

63

64

64

69

495

4150

4200

4255

4315

70,4

102,0

147,0

195,0

230,0

298,0

91,7

132,7

198,8

260,4

320,4

409,3

71,4

100,0

150,0

201,0

248,0

317,0

26,1

37,0

57,2

75,9

97,1

120,0

24,5

35,3

55,9

73,3

89,6

121,2

27,2

37,8

56,2

78,8

93,8

119,0

(AUTOMATIC 1) ˆ Recovery heating capacity

kW

(AUTOMATIC 2) † Nominal heating capacity

kW

(SELECT 1-2 AUTOMATIC 3) … Absorbed power

kW

(AUTOMATIC 1) ˆ Absorbed power

kW

(AUTOMATIC 2) † Absorbed power

kW

(SELECT 1-2 AUTOMATIC 3) ‡ Sound pressure level

dB(A)

TXAEB-TXAES MODEL

56

56

58

60

60

64

475

495

4150

4200

4255

4315 4/2

Scroll/step compressor

No.

4/2

4/2

4/2

4/2

4/2

Circuits

No.

2

2

2

2

2

2

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

475

495

4150

4200

4255

4315

W - Width

mm

3.353

3.353

3.797

4.902

4.902

4.902

H - Height

mm

2.049

2.049

2.049

2.049

2.049

2.100

D - Depth

mm

2.062

2.062

2.062

2.062

2.062

2.062

kg

1.802

1.896

2.276

3.030

3.190

3.280

Main supply DIMENSIONS AND WEIGHTS

‰ Weight TXAEB-TXAES In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C, 70%, D.B - 6°C W.B. - Water: 40/45°C.

‡ At 5 m from the unit, coil side, in free field (Q = 2). ˆ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow. ‰ Weight of fully accessorised unit when empty.

EXP Polyvalent systems

… Nominal cooling capacity

60 475

CONDENSING UNITS

dB(A)

TXAES MODEL

SYSTEM ACCESSORIES

‡ Sound pressure level

FAN COIL UNITS

(AUTOMATIC 2)

TERMINAL UNITS

ˆ C.O.P.

INDUSTRIAL & PROCESS COOLING

(SELECT 1-2 AUTOMATIC 3)

Z-Power Range EXP 86

GREEN LINE

TXAVZ 2400÷2680 Cooling capacity: 384÷680 kW - Heating capacity: 409÷700 kW

TXAVSZ 2680

TXAVSZ 2530

EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with semihermetic screw compressors and R134a refrigerant gas.

Versions • B - Standard version (TXAVBZ). • S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). • I -Soundproofed version with soundproofed compressor cover (TXAVIZ).

Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater, refrigerant gas delivery piping shut-off valve and compressor oil level sensor. • Electronic expansion valve: as standard on all models. • Main and secondary heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

Models • TXAVBZ: standard EXPsystems unit. • TXAVSZ: silenced EXPsystems unit. • TXAVIZ: soundproofed EXPsystems unit.

FACTORY FITTED ACCESSORIES • Power factor correction capacitors (cosφ > 0.94). • Compressor and fan thermal overload switches. • Inlet compressor shut-off valves. • Bottom compartment protection grilles. • Main and secondary heat exchanger antifreeze heater. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Copper/pre-painted aluminium/ copper/copper or copper/tinplated copper coils. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Protection coil grilles. • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

… Nominal cooling capacity

2460

2530

2600

2680

kW

400

464

532

600

680

kW

528

605

691

773

872

kW

426

486

563

620

700

kW

148,2

165,4

184,7

202,4

226,4

kW

132,2

145,4

164,7

178,4

198,4

kW

141,9

158,9

177,6

196,8

220,7

2,70

2,81

2,88

2,97

3,00

3,00

3,06

3,17

3,15

3,17

(AUTOMATIC 1) ˆ Recovery heating capacity (AUTOMATIC 2) † Nominal heating capacity

AIR cooled AXIAL fans

2400

 TXAVB MODEL

WATER CHILLERS HEAT PUMPS

87

OUTDOOR INSTALLATION

(AUTOMATIC 2) † Absorbed power

AIR cooled CENTRIFUGAL fans

ˆ Absorbed power

WATER cooled CONDENSERLESS UNITS

(AUTOMATIC 1)

WATER CHILLERS HEAT PUMPS

… Absorbed power

WATER CHILLERS HEAT PUMPS

(SELECT 1-2 AUTOMATIC 3)

dB(A)

TXAVSZ MODEL … Nominal cooling capacity

kW

80

81

81

82

82

2400

2460

2530

2600

2680

384

446

511

576

653

528

605

691

773

872

409

467

540

595

672

147,5

164,6

183,8

201,4

225,3

132,2

145,4

164,7

178,4

198,4

141,2

158,1

176,7

195,8

219,6

2,60

2,71

2,78

2,86

2,90

2,90

2,95

3,06

3,04

3,06

(AUTOMATIC 1) ˆ Recovery heating capacity

kW

(AUTOMATIC 2) † Nominal heating capacity

kW

(SELECT 1-2 AUTOMATIC 3) … Absorbed power

kW

(AUTOMATIC 1) ˆ Absorbed power

kW

(AUTOMATIC 2) † Absorbed power

kW

(SELECT 1-2 AUTOMATIC 3) E.E.R. (AUTOMATIC 1) C.O.P. (SELECT 1-2 AUTOMATIC 3) ‡ Sound pressure level

dB(A)

MODEL

74

75

75

76

76

2400

2460

2530

2600

2680 2/6

Screw compressor/steps

No.

2/6

2/6

2/6

2/6

Circuits

No.

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

DIMENSIONS AND WEIGHTS TXAVBZ-TXAVSZ

2400

2460

2530

2600

2680

W - Width

mm

6.130

6.130

6.130

6.980

7.980

H - Height

mm

2.430

2.430

2.430

2.430

2.430

D - Depth

mm

2.260

2.260

2.260

2.260

2.260

kg

5.900

6.220

6.340

7.300

8.370

Main supply

‰ Weight TXAVBZ In the following conditions: … Air: 35°C - Water: 7/12°C. † Air: 7°C, 70%, D.B - 6°C W.B. - Water: 40/45°C.

‡ At 1 m from the unit, coil side, in free field (Q = 2). ˆ Evaporator water: 7/12°C. Recovery outlet water 45°C - Nominal flow. ‰ Empty weight.

EXP Polyvalent systems

‡ Sound pressure level

CONDENSING UNITS

(SELECT 1-2 AUTOMATIC 3)

SYSTEM ACCESSORIES

C.O.P.

FAN COIL UNITS

(AUTOMATIC 1)

TERMINAL UNITS

E.E.R.

INDUSTRIAL & PROCESS COOLING

(SELECT 1-2 AUTOMATIC 3)

Comby-Flow EXP Range 88

GREEN LINE

TXHEY 105÷112 Cooling capacity: 5.4÷12 kW - Heating capacity: 6.5÷14.5 kW

EXPsystems - Polyvalent ecological watercooled system. Range with hermetic Scroll compressors and R410A refrigerant gas.

FACTORY FITTED ACCESSORIES

Construction features

• Digital input for double set-point • 4-20 mA analogue input for shifting set-point.

• Compressor: hermetic, rotary Scroll compressor, complete with thermal protection. • Primary side heat exchanger (user), secondary side exchanger (recovery) and disposal unit: adequately insulated stainless steel plates, complete with antifreeze electric heater and water flow differential pressure switch. • Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. • Condensation control: pressure switch valve and bypass solenoid valve. • Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment.

Models • TXHEY: standard EXPsystems unit.

PUMP unit • Primary side (user): pumping group complete with circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge. • Well/tower side (disposal unit): drain valve and bleed valve. Internal cock for primary side (use) system supply from external network (disposal unit side: well or tower).

• Secondary side (recovery): pumping group complete with circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge.

ACCESSORIES SUPPLIED LOOSE • Water buffer tank • Buffer connection pipes • Water filter • Antivibration rubber mountings. • Antifreeze electric heater on the buffer tank. • Remote keyboard with display. • Clock card • Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). • Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. • Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. • GSM 900/1800 modem kit for remote unit management. • RHOSS supervision software for unit monitoring and remote management.

… Nominal cooling capacity

107

109

112

kW

5,4

6,8

9,3

12,0

kW

6,7

8,7

11,3

14,5

kW

6,5

8,2

10,8

13,9

kW

1,56

2,12

2,74

3,60

kW

2,00

2,83

3,57

4,75

kW

2,04

2,88

3,54

4,38

5,72

5,14

5,42

5,67

(AUTOMATIC 1) † Recovery heating capacity (AUTOMATIC 2) ‡ Nominal heating capacity

AIR cooled AXIAL fans

105

TXHEY P MODEL

WATER CHILLERS HEAT PUMPS

89

INDOOR INSTALLATION

(AUTOMATIC 2) ‡ Total absorbed power (*)

AIR cooled CENTRIFUGAL fans

† Total absorbed power (*)

WATER cooled CONDENSERLESS UNITS

(AUTOMATIC 1)

WATER CHILLERS HEAT PUMPS

… Total absorbed power (*)

WATER CHILLERS HEAT PUMPS

(SELECT 1-2 AUTOMATIC 3)

dB(A)

49,1

51,1

51,3

53,1

Scroll/step compressor

No.

1

1

1

1

Circuits

No.

1

1

1

1

l

20

20

30

30

kPa

47,0

54,7

82,2

78,2

kPa

32,4

42,4

72,1

66,7

V-ph-Hz

230-1-50

Water buffer tank content KA … Nominal available head pressure at pump on main exchanger † Nominal available head pressure on secondary recovery exchanger Main supply

230-1-50

230-1-50

230-1-50

400-3+N-50

400-3+N-50

400-3+N-50

105

107

109

112

W - Width

mm

585

585

660

660

H - Height TXHEY P

mm

535

535

535

535

H - Height TXHEY P + KA

mm

855

855

855

855

D - Depth

mm

520

520

560

560

Weight TXHEY

kg

112

118

122

130

Weight KA

kg

38

38

43

43

In the following conditions: … Condenser water: 30/35°C - Chilled water: 7/12°C. † Chilled water: 7/12°C - Regenerator water: 40/45°C ‡ Evaporator water: 10°C - Water flow rate as in summer operation. Hot water 40/45°C. ˆ At 1 m from the unit in free field (Q = 2).

(*) Unit without pumps. KA = Water buffer tank. KTC = Connection pipes.

SYSTEM ACCESSORIES

DIMENSIONS AND WEIGHTS

EXP Polyvalent systems

ˆ Sound pressure level

CONDENSING UNITS

(AUTOMATIC 2)

FAN COIL UNITS

2 2-pipe systems

Production of chilled or hot water for Summer or Winter air conditioning and/or hot water for domestic use through EXPsystems units with water cooling (ex. residential environments).

TERMINAL UNITS

†C.O.P.

INDUSTRIAL & PROCESS COOLING

(SELECT 1-2 AUTOMATIC 3)

Z-Flow Range EXP 90

GREEN LINE

TXHVZ 2390÷2800 Cooling capacity: 411÷850 kW - Heating capacity: 462÷953 kW

TXHVIZ 2710

EXPsystems - Polyvalent ecological watercooled system. Range with semihermetic screw compressors and R134a refrigerant gas.

Versions • B - Standard version (TXHVBZ). • I -Soundproofed version with soundproofed compressor cover (TXHVIZ).

Models Construction features • Compressor: high energy efficiency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater, refrigerant gas delivery piping shut-off valve and compressor oil level sensor. • Electronic expansion valve: as standard on all models. • Primary side heat exchanger (user), secondary side exchanger (recovery) and disposal unit: dry expansion shell and tube exchangers, complete with closed cell polyurethane rubber foam insulation, water flow differential pressure switch and Victaulic connections. • Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). • Structure: in galvanised and painted sheet steel, with polyester powder coating. • The unit is also complete with: - low and high pressure gauges for each refrigerant circuit.

• TXHVBZ: standard EXPsystems unit. • TXHVIZ: soundproofed EXPsystems unit.

FACTORY FITTED ACCESSORIES • Power factor correction capacitors (cosφ > 0.94). • Compressor thermal overload switches. • Inlet compressor shut-off valves. • Heat exchanger antifreeze heater. • Digital input for double set-point • Display of refrigerant circuit high/low pressure. • Control of min/max power supply voltage. • 4-20 mA analogue input for shifting set-point. • Serial interface for connection with external BMS.

ACCESSORIES SUPPLIED LOOSE • Spring antivibration mountings. • Remote keyboard with display. • Rhoss sequencer for the integrated management of several water chillers.

… Nominal cooling capacity

2430

2480

2560

2630

2710

2800

kW

411,0

455,0

508,0

599,0

668,0

748,0

850,0

kW

387,0

431,0

480,0

566,0

630,0

706,0

800,0

kW

439,0

495,0

540,0

640,0

709,0

804,0

906,0

kW

462,0

521,0

568,0

671,0

747,0

848,0

953,0

kW

80,4

89,4

94,7

109,3

124,2

141,0

161,2

kW

88,3

98,3

103,8

120,8

135,0

154,0

176,7

kW

105,7

119,1

123,8

145,0

160,5

184,4

210,5

kW

107,7

121,4

126,1

147,5

164,0

188,1

214,6

5,11

5,09

5,36

5,48

5,38

5,30

5,27

4,38

4,38

4,62

4,69

4,67

4,58

4,53

4,29

4,29

4,50

4,55

4,55

4,51

4,44 2800

(AUTOMATIC 1) † Nominal cooling capacity (AUTOMATIC 1) ‡ Recovery heating capacity

(AUTOMATIC 1) † Total absorbed power

AIR cooled CENTRIFUGAL fans

… Total absorbed power

WATER cooled CONDENSERLESS UNITS

(SELECT 1-2 AUTOMATIC 3)

WATER CHILLERS HEAT PUMPS

ˆ Nominal heating capacity

WATER CHILLERS HEAT PUMPS

(AUTOMATIC 2)

… E.E.R. (AUTOMATIC 1) † E.E.R. (AUTOMATIC 1) ˆ C.O.P. (SELECT 1-2 AUTOMATIC 3)

2390

2430

2480

2560

2630

2710

dB(A)

97

97

98

99

99

99

99

No.

2/6

2/6

2/6

2/6

2/6

2/6

2/6

TXHVBZ MODEL ‰ Sound power level Screw compressor/steps Circuits Main supply

No.

2

2

2

2

2

2

2

V-ph-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

2390

2430

2480

2560

2630

2710

2800

W - Width

mm

4.420

4.420

4.420

4.420

4.420

4.420

4.420

H - Height

mm

2.030

2.030

2.030

2.030

2.030

2.030

2.030

D - Depth

mm

1.620

1.620

1.620

1.620

1.620

1.620

1.620

DIMENSIONS AND WEIGHTS

In the following conditions: … Chilled water (user): 7/12°C - Condenser water (disposal unit-source): 14/30°C. † Chilled water (user): 7/12°C - Condenser water: 30/35°C. ‡ Chilled water (user): 7/12°C - Condenser wate (regenerator)r: 40/45°C. ˆ Condenser water (source): 14°C - Water flow rate as in summer operation (…). Hot water (user): 40/45°C. ‰ Total sound power level in dB(A) on the basis of measurements taken in accordance with ISO 3744.

EXP Polyvalent systems

(SELECT 1-2 AUTOMATIC 3)

CONDENSING UNITS

ˆ Total absorbed power

SYSTEM ACCESSORIES

(AUTOMATIC 2)

FAN COIL UNITS

‡ Total absorbed power

INDUSTRIAL & PROCESS COOLING

(AUTOMATIC 1)

TERMINAL UNITS

P R E L I M I N A R Y

AIR cooled AXIAL fans

2390

TXHVBZ - TXHVIZ MODEL

WATER CHILLERS HEAT PUMPS

91

INDOOR INSTALLATION

92

MCAE-MHAE 105÷127 Cooling capacity: 5.1÷26.3 kW - Heating capacity: 6÷29.9 kW

Air-cooled condensing units and reversible condensing units, with axial fans. Range with hermetic compressors and R407C refrigerant gas.

Models

Construction features

• MCAE: unit designed for cooling only. • MHAE: heat pump unit.

• Compressor: hermetic rotary blade compressor complete with thermal protection (mod. 105÷106); hermetic Scroll compressor, complete with thermal protection (mod. 108÷127). • Air side heat exchanger: featuring finned coil with copper pipes and aluminium fins, complete with protection grille. • Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. • Control: microprocessor electronic control. • Structure: galvanised and painted sheet steel with epoxy finish, complete with rubber antivibration mountings and cataphoresis-

treated sheet steel base (mod. 105-110), in peraluman with galvanised sheet steel base and soundproofed compressor compartment (mod. 115-127).

ACCESSORIES SUPPLIED LOOSE • Wall-support shelves (mod.105÷110). • Connection cover (mod. 105÷110). • Low pressure switch (mod. 105-106). • Rubber antivibration mountings (mod. 115÷127) • -10°C condensation control. • RS 485 serial interface (mod.115÷127). • RS 232 hardware key (mod. 115÷127).

3,00

3,40

105

106

108

110

6,0

7,2

9,0

10,4

† Nominal heating capacity

kW

… Nominal cooling capacity

kW

5,1

6,3

7,6

8,5

† Absorbed power

kW

1,75

2,10

2,81

3,20 110

105

106

108

dB(A)

54

53

55

54

V-ph-Hz

230-1-50

230-1-50

230-1-50

400-3+N-50

105

106

MCAE-MHAE MODEL ‡Sound pressure level Main supply

400-3+N-50 108

110

W - Width

mm

790

790

830

830

H - Height

mm

600

600

900

900

D - Depth

mm

300

300

300

300

Weight MCAE

kg

59

65

84

85

Weight MHAE

kg

60

66

88

90

115

118

122

127

… Nominal cooling capacity

kW

14,7

17,6

21,8

26,3

… Absorbed power

kW

4,91

5,65

7,41

8,92

115

118

122

127

kW

15,8

19,9

24,5

29,9

… Nominal cooling capacity

kW

14,7

17,6

21,8

26,3

† Absorbed power

kW

5,12

5,63

7,23

8,40

115

118

122

127

dB(A)

49

50

51

52

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

115

118

122

127

mm

1.326

1.326

1.716

1.716

H - Height

mm

1.230

1.230

1.230

1.230

D - Depth

mm

527

527

615

615

Weight MCAE

kg

180

200

260

290

Weight MHAE

kg

200

210

280

300

DIMENSIONS AND WEIGHTS

MCAE MODEL

MHAE MODEL † Nominal heating capacity

MCAE-MHAE MODEL ‡Sound pressure level Main supply DIMENSIONS AND WEIGHTS W - Width

In the following conditions: … Air: 35°C - Suctioned saturated gas: 7°C. †Air: 6°C W.B. - Condensation: 45°C (mod. 105-110); 50°C (mod. 115-127). ‡ At 5 m from the unit in free field (Q = 2).

AIR cooled AXIAL fans

2,45

AIR cooled CENTRIFUGAL fans

1,87

WATER cooled CONDENSERLESS UNITS

kW

WATER CHILLERS HEAT PUMPS

8,5

… Absorbed power MHAE MODEL

110

WATER CHILLERS HEAT PUMPS

7,6

INDUSTRIAL & PROCESS COOLING

6,3

EXP Polyvalent systems

108

5,1

CONDENSING UNITS

106

kW

SYSTEM ACCESSORIES

105

… Nominal cooling capacity

MCAE MODEL

WATER CHILLERS HEAT PUMPS

93

OUTDOOR INSTALLATION

FAN COIL UNITS

HEAT PUMP

TERMINAL UNITS

COOLING ONLY

94

MCAE 131÷2181 Cooling capacity: 30.5÷181.1 kW

Air-cooled condensing units with axial fans. Range with hermetic compressors and R407C refrigerant gas. Construction features • Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. • Air side heat exchanger: finned coil exchanger with copper pipes and aluminium fins. • Fan: electric axial fans with external rotor, equipped with internal thermal protection, proportional electronic device for continuous fan rotation speed regulation and protection grilles. • Control: microprocessor electronic control. • Structure: in galvanised and painted sheet steel, with polyurethane powder coating.

Models • MCAE: unit designed for cooling only.

FACTORY FITTED ACCESSORIES • Compressor compartment soundproofing. • Coil protection metal filters. • Refrigerant circuit high and low pressure gauges. • Liquid receiver. • Liquid and gas line shut-off valves.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • Thermostatic valve kit. • Remote keyboard with display. • Serial interface for connection with external BMS.

… Absorbed power

kW

8,6

10,8

12,9

12,5

15,1

17,1

19,3

Scroll/step compressor

No.

1/1

1/1

1/1

2/2

2/2

2/2

2/2

Circuits

No.

1

1

1

1

1

1

1

dB(A)

52,5

52,5

52,5

52,5

52,5

52,5

52,5

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

131

139

145

243

252

261

268

mm

1.870

1.870

1.870

1.870

1.870

2.608

2.608

H - Height

mm

1.406

1.406

1.406

1.406

1.406

1.759

1.759

D - Depth

mm

850

850

850

850

850

1.105

1.105

kg

320

331

342

545

560

690

705

‡Sound pressure level Main supply DIMENSIONS AND WEIGHTS W - Width

Weight

276

291

2103

2121

2136

2146

2163

2181

… Nominal cooling capacity

kW

75,5

90,1

103,0

120,5

135,5

140,4

163,2

181,1

… Absorbed power

kW

21,5

25,8

30,0

34,1

38,2

40,3

46,4

50,5

Scroll/step compressor

No.

2/2

2/2

2/2

2/2

2/2

2/2

2/2

2/2

Circuits

No.

1

1

1

1

1

1

1

1

dB(A)

53,5

53,5

55,5

56,0

56,4

56,6

57,0

57,5

V-ph-Hz

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

400-3+N-50

276

291

2103

2121

2136

2146

2163

2181

MCAE MODEL

‡Sound pressure level Main supply DIMENSIONS AND WEIGHTS W - Width

mm

2.608

2.608

3.608

3.608

3.608

3.608

3.608

3.608

H - Height

mm

1.759

1.759

1.759

1.759

1.759

1.759

2.179

2.179

D - Depth

mm

1.105

1.105

1.105

1.105

1.105

1.105

1.105

1.105

kg

740

790

1.040

1.120

1.170

1.200

1.300

1.480

Weight In the following conditions: … Air: 35°C - Suctioned saturated gas: 5°C. ‡ At 10 m from the unit in free field (Q = 2).

AIR cooled AXIAL fans

268 67,6

AIR cooled CENTRIFUGAL fans

261 61,1

WATER cooled CONDENSERLESS UNITS

252 52,2

WATER CHILLERS HEAT PUMPS

243 43,0

WATER CHILLERS HEAT PUMPS

145 45,2

INDUSTRIAL & PROCESS COOLING

139 37,0

EXP Polyvalent systems

131 30,5

CONDENSING UNITS

kW

SYSTEM ACCESSORIES

… Nominal cooling capacity

FAN COIL UNITS

MCAE MODEL

WATER CHILLERS HEAT PUMPS

95

OUTDOOR INSTALLATION

TERMINAL UNITS

COOLING ONLY

Remote condensers 96

CCAM 105÷2130

Remote air condensers with axial fans for direct expansion units operating with R407C refrigerant gas. Construction features • Heat exchanger: featuring high efficiency finned coil with copper pipes joined to aluminium fins by mechanical expansion. The unit undergoes pressure and seal tests, guaranteeing a maximum working pressure of 31 bar. • The refrigerant circuits connections need brazing. • The units are supplied pressurised with nitrogen. • Fans: axial fans with external rotor; rotating body of motor and fan blades with aerodynamic configuration that guarantees quiet operation and high performance. The electric fans are also speed-adjustable (by means of the TCEE 105÷2130 evaporator unit PSC accessory) and are protected against overloads by thermal overload switches. • Structure: in galvanised and painted sheet steel with epoxy powder coating. • The remote condensers come equipped with a support bracket kit for vertical/horizontal air flow. The support brackets are made from stainless steel for the condensers with fans measuring from 400-

500 mm, and in galvanised and painted steel for the condensers with fans measuring from 630÷1,000 mm. • The brackets are of an optimum length for uniform air suction into the coil. • The motors are wired in compliance with VDE 0530/12.84. • IP54 protection, in compliance with DIN 40050. • Electrical panel compliant with IEC standards. Sealed box with IP55 protection, complete with: - Main isolating switch complete with door interlocking isolator; - Power contactors; - Thermal overload switch; - Indicator lights and remote-controlled alarms. - The electric panel for condensers with fans measuring from 400 to 500 mm is not installed upon delivery. The client is responsible for its installation.

Versions • The CCAM 105÷2130 range remote condensers are available in 3 construction options that meet the different system requirements concerning ambient noise emission: - Version “N” Normal (mod. 105-115 excluded); - Version “S” Silenced; - Version “Q” Supersilenced.

155N

165N

280N

2110N

2130N

… Nominal heating capacity

kW

23,1

36,5

45,2

54,8

67,8

85,3

99,8

133,9

161,4

dB(A)

43

44

46

46

48

49

59

61

61

Refrigerant circuits

No.

1

1

1

1

1

1

1

1

1

Fans

No.

1

2

2

3

3

4

2

3

3

Fan nominal air flow

m/h

7.091

13.102

14.423

19.653

21.635

28.847

35.520

51.510

48.780

Rotation speed

rpm

1.390

1.180

1.390

1.180

1.390

1.390

1.310

1.310

1.310

kW

0,72

1,10

1,44

1,65

2,16

2,88

5,20

7,80

7,80

† Sound pressure level

… Absorbed power Main supply

V-ph-Hz 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50

CCAM MODEL

105S

115S

120S

125S

135S

140S

155S

165S

280S

2110S

2130S

AIR cooled AXIAL fans

140N

AIR cooled CENTRIFUGAL fans

135N

WATER cooled CONDENSERLESS UNITS

125N

WATER CHILLERS HEAT PUMPS

120N

VERSION N “Normal”

WATER CHILLERS HEAT PUMPS

CCAM MODEL

WATER CHILLERS HEAT PUMPS

97

OUTDOOR INSTALLATION

11,7

15,1

23,4

33,2

45,4

54,8

63,4

77,5

96,0

123,3

172,3

36

34

37

37

39

46

46

47

52

49

49

Refrigerant circuits

No.

1

1

1

1

1

1

1

1

1

1

1

Fans

No.

2

1

2

2

3

3

3

4

1

2

3

Fan nominal air flow

m/h

4.994

4.964

10.471

9.449

14.892

19.653

18.330

24.901

29.530

31.940

50.100

Rotation speed

rpm

940

930

930

930

930

1.180

1.180

1.180

890

660

680

kW

0,32

0,27

0,54

0,54

0,81

1,65

1,65

2,20

3,60

2,50

3,15

V-ph-Hz

230/1/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

105Q

115Q

120Q

125Q

135Q

140Q

155Q

165Q

280Q

2110Q

2130Q

CCAM MODEL

400/3+N/50 400/3+N/50

VERSION Q “Supersilenced” … Nominal heating capacity

kW

12,0

15,3

24,1

30,4

45,5

52,8

65,7

81,8

104,0

134,8

170,1

dB(A)

29

32

32

35

37

35

40

38

46

43

45

Refrigerant circuits

No.

1

1

1

1

1

1

1

1

1

1

1

Fans

No.

1

1

2

2

3

4

4

2

4

2

3

Fan nominal air flow

m/h

3.598

4.218

7.236

8.436

12.653

13.728

18.898

19.610

31.400

34.180

60.870

Rotation speed

rpm

665

800

680

800

800

680

930

440

690

420

420

kW

0,13

0,19

0,30

0,38

0,57

0,60

1,08

0,74

1,92

1,72

2,58

V-ph-Hz

230/1/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

400/3+N/50

† Sound pressure level

… Absorbed power Main supply

400/3+N/50 400/3+N/50

CONDENSING UNITS

In the following conditions: … External temperature: 35°C D.B., 24°C W.B. - Dew point: 50°C. - Subcooling 3°K Superheating 25°K. - Maximum speed. † At 10 m from the unit in free field (Q = 2).

Sound pressure level correction for distances other than 10 m Distance Correlation

(m)

2

3

4

5

7

10

15

20

30

40

50

60

80

dB(A)

11

8,5

7

5

2,5

0

–3

–5,5

–9

–11

–12

–14

–16

SYSTEM ACCESSORIES

Main supply

FAN COIL UNITS

… Absorbed power

EXP Polyvalent systems

kW dB(A)

† Sound pressure level

TERMINAL UNITS

… Nominal heating capacity

INDUSTRIAL & PROCESS COOLING

VERSION S "Silenced"

Cooling towers 98

CEHV CEHP 46÷2791

• Wide range of models up to 2,800 kW • Silenced version with considerable noise reduction • Compact easy to install units

Cooling towers for water chillers with water condensation. Axial fans Construction features • Distribution system: polyvinyl chloride pipes and plastic spray nozzles. • Heat exchange package: panel exchanger with plastic cellular structure with large slots. • Drop separator: plastic. • Fan: axial fan directly coupled with protection grille. • Condensation drain pan: in polyester resin strengthened with fibreglass complete with spray protection fins, drain connections, float re-integration and overflow. • Structure: in polyester resin strengthened with fibreglass and loadbearing for models of the CEHV range; with hot- galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with fibreglass for models of the CEHP-CEHPS range.

Models • CEHV 46÷639 Cooling towers with load-bearing polyester resin structure strengthened with fibreglass. • CEHP 744÷2791 Cooling towers with hot- galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with fibreglass. • CEHPS 744÷2791 Silenced cooling towers with hot- galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with fibreglass.

FACTORY FITTED ACCESSORIES CEHV Range • Inspection pothole. • Electrical anti-freeze heater on condensation drain pan complete with minimum level switch.

CEHP – CEHPS range • Manhole. • Dismantable side wall. • Electrical anti-freeze heater on condensation drain pan complete with minimum level switch.

87

105

139

169

203

238

337

395

477

506

599

639

46,5

87,2

104,7

139,5

168,6

203,5

238,4

337,2

395,3

476,7

505,8

598,8

639,5

0,75

0,75

1,1

1,1

1,1

1,1

2,2

2,2

4

4

4

4

74

75

75

75

75

77

77

80

80

83

83

85

85

dB(A)

46

47

47

47

47

49

49

52

52

55

55

57

57

169

203

238

337

395

477

506

599

639

1200

1200

1400

1400

1740

1740

2100

2100

2300

2300

H - Height

mm

2110

2595

2595

2800

2800

2860

2860

3140

3140

3380

3380

3450

3450

D - Depth

mm

800

1000

1000

1200

1200

1400

1400

1740

1740

1900

1900

2100

2100

Empty weight

kg

75

85

95

155

170

195

210

380

410

500

525

555

580

Operating weight

kg

180

215

285

470

485

755

780

1380

1410

1800

1825

1955

1980

744

CEHP MODEL … Nominal heating capacity consumption

kW 744,2

826

878

971

1070 1186 1256 1395 1488 1651

825,6 877,9 970,9 1069,8

1756

1948 2139 2366

2512 2791

1186 1255,8 1395,3 1488,4 1651,2 1755,8 1947,7 2139,5 2366,3 2511,6 2790,7

kW)

4

5,5

5,5

7,5

7,5

11

11

11

Sound power level

dB(A)

90

90

92

92

94

94

95

95

93

93

95

95

97

97

98

98

†Sound pressure level

dB(A)

62

62

64

64

66

66

67

67

65

65

67

67

69

69

70

70

Installed fan electrical power

Main supply

2X4 2X5,5 2X5,5 2X7,5 2X7,5

2X11

2X11 2X11

380/660-3-50

V-ph-Hz 744

826

878

971

1070 1186 1256 1395 1488 1651

1756

1948 2139 2366

2512 2791

W - Width

mm

2025

2025

2365

2365

2875

2875

3370

3370

4080

4080

4750

4750 5770

5770

6770 6770

H - Height

mm

3650

3650

3650

3650

3650

3650

3650

3650

3650

3650

3650

3650 3950

3950

3950 3950

D - Depth

mm

2365

2365

2365

2365

2365

2365

2365

2365

2365

2365

2365

2365 2365

2365

2365 2365

Empty weight

kg

885

920

965

1000

1115

1165

1220

1270

1630

1700

1790

1860 2125

2225

2375 2475

Operating weight

kg

2485

2520

2865

2900

3815

3865

4320

4370

4680

4750

5430

5500 7325

7425

8375 8475

826

878

971

1070 1186 1256 1395 1488 1651

1756

1948 2139 2366

2512 2791

DIMENSIONS AND WEIGHTS

744

CEHPS MODEL … Nominal heating capacity consumption

kW 744,2

825,6 877,9 970,9 1069,8

1186 1255,8 1395,3 1488,4 1651,2 1755,8 1947,7 2139,5 2366,3 2511,6 2790,7

kW

5,5

5,5

7,5

7,5

11

11

11

11 2X5,5 2X5,5 2X7,5 2X7,5 2X11

Sound power level

dB(A)

79

79

80

80

82

82

83

83

82

82

83

83

85

85

86

86

†Sound pressure level

dB(A)

51

51

52

52

54

54

55

55

54

54

55

55

57

57

58

58

Installed fan electrical power

Main supply

2X11

2X11 2X11

380/660-3-50

V-ph-Hz 744

826

878

971

1070 1186 1256 1395 1488 1651

1756

1948 2139 2366

2512 2791

W - Width

mm

2025

2025

2365

2365

2875

2875

3370

3370

4080

4080

4750

4750 5770

5770

6770 6770

H - Height

mm

3905

3905

3905

3905

3905

3905

3905

3905

3905

3905

3905

3905 4205

4205

4205 4205

D - Depth

mm

2365

2365

2365

2365

2365

2365

2365

2365

2365

2365

2365

2365 2365

2365

2365 2365

Empty weight

kg

885

920

965

1000

1115

1165

1220

1270

1630

1700

1790

1860 2125

2225

2375 2475

Operating weight

kg

2485

2520

2865

2900

3815

3865

4320

4370

4680

4750

5430

5500 7325

7425

8375 8475

DIMENSIONS AND WEIGHTS

In the following conditions: …Air: 24°C W.B. - Water: 35/30°C.  At 10 m from the unit in free field (Q = 2).

AIR cooled CENTRIFUGAL fans

139

1000

WATER cooled CONDENSERLESS UNITS

105

1000

WATER CHILLERS HEAT PUMPS

87

800

W - Width

INDUSTRIAL & PROCESS COOLING

46 mm

DIMENSIONS AND WEIGHTS

WATER CHILLERS HEAT PUMPS

220/380-3-50

V-ph-Hz

EXP Polyvalent systems

Main supply

0,55

CONDENSING UNITS

†Sound pressure level

kW) dB(A)

SYSTEM ACCESSORIES

Sound power level

FAN COIL UNITS

Installed fan electrical power

TERMINAL UNITS

… Nominal heating capacity consumption

AIR cooled AXIAL fans

46 kW

CEHV MODEL

WATER CHILLERS HEAT PUMPS

99

OUTDOOR INSTALLATION

Pumping groups 100

AS 0300÷2500

• Water buffer tank from 300 to 2,500 l • Multiple choices for pump user-side • Connection to the system on the water outlet, on the water return

Pumping groups with buffer tank. Construction features • Water buffer tank: in carbon steel with a capacity of 300, 500, 750, 1,000, 1,500, or 2,500 litres. • Hydraulic components: single or double centrifugal pump, inlet and outlet shut-off ball valve of each pump, automatic reintegration tap, manual re-integration tap, safety valve, automatic air bleed valve, tank water drain tap, expansion tank with membrane, no-return valve (with double pump only), pressure gauge. • The water circuit is insulated with closed cell expanded polyurethane of adequate thickness. • Structure: Load-bearing structure made of aluminium sheet metal panelling and base in galvanised and painted steel. • Control: electromechanical.

Versions • AS – Standard version with two connections.

Models • AS 0300 PU or DPU 1÷5: pumping group equipped with single pump on user side (PU) or double pump on user side (DPU). • AS 0500 PU or DPU 1÷5: pumping group equipped with single pump on user side (PU) or double pump on user side (DPU). • AS 0750 PU or DPU 6÷10: pumping group equipped with single pump on user side (PU) or double pump on user side (DPU). • AS 1000 PU or DPU 6÷10: pumping group equipped with single pump on user side (PU) or double pump on user side (DPU). • AS 1500 PU or DPU 6÷14: pumping group equipped with single pump on user side (PU) or double pump on user side (DPU). • AS 2500 PU or DPU 6÷14: pumping group equipped with single pump on user side (PU) or double pump on user side (DPU).

ACCESSORIES SUPPLIED LOOSE • Victaulic connections. • Tank antifreeze electric heater with activator.

6-7-8-9-10-11-12-13-14

l

25

25

25

25

2X25

X25

Expansion tank calibration

bar

1,5

1,5

1,5

1,5

1,5

1,5

Safety valve calibration

bar

3,0

3,0

3,0

3,0

3,0

3,0

Maximum working pressure

bar

3,0

3,0

3,0

3,0

3,0

3,0

W

1.300

1.300

1.300

1.300

1.300X2

1.300X2

Expansion tank capacity

Electric heater (optional) Hydraulic connections (female) Main supply

ø (Gas)

21/2”

21/2”

3”

3”

4”

4”

V-pH-Hz

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

AS 0300

AS 0500

AS 0750

AS 1000

AS 1500

AS 2500

W - Width

mm

1.504

1.504

2.044

2.044

2.260

2.260

H - Height

mm

1.265

1.265

1.510

1.510

1.782

1.782

D - Depth

mm

1.120

1.120

1.200

1.200

1.900

1.900

Weight (*)

kg

231

253

501

528

878

930

DIMENSIONS AND WEIGHTS

(*) Weight of fully accessorised unit when empty.

PUMP

TANK

Flow rate

Available head pressure (*)

Flow rate

Available head pressure(*)

Flow rate

Available head pressure (*)

Model

litres

m/h

m water column

m/h

m water column.

m/h

m water column.

1

300 o 500

12

15,5

15

13,5

18

11,1

2

300 o 500

12

19,0

15

17,0

18

14,7

3

300 o 500

21

12,4

24

10,8

30

7,5

4

300 o 500

21

18,2

24

16,6

30

13,3

5

300 o 500

21

20,4

24

18,8

30

15,6

6

750 o 1.000

36

17,0

42

16,0

48

14,1

7

750 o 1.000

42

27,4

48

25,2

60

20,5

8

750 o 1.000

60

17,9

72

15,0

84

12,0

9

750 o 1.000

72

20,5

84

17,5

96

15,0

10

750 o 1.000

72

29,0

84

26,0

96

23,0

11

1.500 o 2.500

72

36,0

84

33,0

96

30,0

12

1.500 o 2.500

108

29,0

120

27,0

138

24,0

13

1.500 o 2.500

108

34,0

120

32,5

138

30,0

14

1.500 o 2.500

108

43,1

120

41,0

138

37,0

(*) Weight of fully accessorised unit when empty.

Diagram with AS pumping group on the water outlet

Diagram with AS pumping group on water return

AIR cooled AXIAL fans

6-7-8-9-10

AIR cooled CENTRIFUGAL fans

2.500

1-2-3-4-5

Pump model

WATER cooled CONDENSERLESS UNITS

AS 2500

1.500

WATER CHILLERS HEAT PUMPS

AS 1500

1.000

WATER CHILLERS HEAT PUMPS

AS 1000

750

INDUSTRIAL & PROCESS COOLING

AS 0750

500

EXP Polyvalent systems

AS 0500

300

CONDENSING UNITS

AS 0300

SYSTEM ACCESSORIES

l

FAN COIL UNITS

Tank capacity

TERMINAL UNITS

MODEL

WATER CHILLERS HEAT PUMPS

101

Pumping groups 102

PBHI 0200-0400 Cooling capacity: 50,2÷249 kW

• Primary and secondary circuit • FREECOOLING version • Pump option with integrated inverter

Pumping groups with buffer tank for combination with TCHE - THHE - TCEE units with hermetic Scroll compressors (models 155 - 4260). Construction features • Water buffer tank: in carbon-plated and pre-painted steel sheet, with a 200 or 425 litre capacity. • Water circuit components: primary circuit complete with single pump, secondary circuit complete with single standard head pressure pump, buffer tank, expansion tank, safety valve, shut-off valves, tank water charge/drain taps and automatic and manual air bleed valves. • Heat exchanger: brazed plate exchanger complete with adjustable flow switch (freecooling version only). • Control: electromechanical. • Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The panels are removable in order to allow for easy access to the internal components.

Versions • B - Standard version: with single primary and secondary circuit pump (standard head pressure). • F -Freecooling version: fitted with indirect freecooling heat exchanger.

Models • PBHI 0200 B: standard pumping group for combination with units TCHE-THHE-TCEE - 155-165 • PBHI 0400 B: standard pumping group for combination with units TCHE-THHE-TCEE - 280-4260 • PBHI 0200 B: freecooling version pumping group for combination with units TCHE-THHE-TCEE - 155-165 • PBHI 0400 B: freecooling version pumping group for combination with units TCHE-THHE-TCEE - 280-4260

FACTORY FITTED ACCESSORIES • Single secondary circuit pump with increased head pressure. • Double secondary circuit pump with standard or increased head pressure, including one in standby with automatic activation. • Single centrifugal pump with built-in inverter, able to maintain a constant pressure despite variations in system demands. • Antifreeze heater 300 W (230V) with activator.

ACCESSORIES SUPPLIED LOOSE • Antivibration rubber mountings. • Flexible tubes for connection to the water chiller/heat pump.

kPa

600

600

Maximum working pressure

kPa

600

600

W

300

300

ø (Gas)

2" F

21/2" F

Electric heater (optional)

dB(A)

71

74

V-ph-Hz

400-3+N-50

400-3+N-50

Sound power level Main supply

0200

0400

W - Width

mm

1.340

1.919

H - Height

mm

1.206

1.706

D - Depth

mm

861

863

DIMENSIONS AND WEIGHTS

PBHI water circuit with single pump on user side FREECOOLING ONLY FREECOOLING

VSA VSM

PZ R

R1

P

R

FL

PZ PHF

PZ

PZ

RA VE

USER UTENZA

SECONDARY CIRCUIT CIRCUITO SECONDARIO

PRIMARY CIRCUIT CIRCUITO PRIMARIO M

R

R

VS

SA

MAC

R1 S

PU

SECONDARY CIRCUIT PUMP ACCESSORIES: PBHI water circuit with double pump on user side FREECOOLING ONLY FREECOOLING

VSA VSM

PZ R

R1

P

R

FL

PZ PHF

PZ

P = Primary circuit circulation pump. PU = Secondary circuit circulation pump. DPU = Double secondary circuit circulation pump (factory fitted accessory). PUI = Secondary circuit circulation inverter pump (factory fitted accessory). FL = Flow switch. M = Pressure gauge. PZ = Pit with internal diameter 6.2 mm. PHF = Plate heat exchanger for freecooling. RA = Buffer tank antifreeze heater (factory fitted accessory). R = Tap. R1 = Tap to be fitted by the installer (provided). S = Water drain/charge tap (outside the buffer tank). SA = Water buffer tank. VE = Expansion tank calculated to contain the water from the buffer tank only (–10°C - +60°C). VR = Non-return valve. VS = Safety valve. VSA = Automatic air bleed valve. VSM = Manual air bleed valve. = Connections.

PZ

RA VE

SECONDARY CIRCUIT CIRCUITO SECONDARIO

UTENZA

VR

PRIMARY CIRCUIT CIRCUITO PRIMARIO

M

R

R

VS

SA

VR

MA

R1

DPU S

PBHI water circuit with single inverter pump on user side FREECOOLING ONLY FREECOOLING

VSA VSM

PZ R

R1

P

R

FL

PZ

PZ PHF

PZ

RA VE UTENZA USER

CIRCUITO SECONDARIO SECONDARY CIRCUIT

R

R PUI

PUMP WITH INVERTER Regulation at constant pressure

50 Hz

H - Head pressure kPa

USER

25 Hz

VS CIRCUITO PRIMARIO PRIMARY CIRCUIT

SA M

MA

R1 S

Q - Flow rate m/h

TERMINAL UNITS

Hydraulic connection (female)

AIR cooled AXIAL fans

Safety valve calibration

AIR cooled CENTRIFUGAL fans

150

WATER cooled CONDENSERLESS UNITS

150

WATER CHILLERS HEAT PUMPS

12

kPa

Expansion tank calibration

WATER CHILLERS HEAT PUMPS

8

INDUSTRIAL & PROCESS COOLING

l

EXP Polyvalent systems

425

Expansion tank capacity

CONDENSING UNITS

200

SYSTEM ACCESSORIES

0400

l

FAN COIL UNITS

0200

Tank capacity

PBHI MODEL

WATER CHILLERS HEAT PUMPS

103

Water chiller management software 104

RHOSS SEQUENCER

• Control of multiple water chillers connected in parallel • Summer/winter mode for heat pump units • System setpoint management • Control of all operating parameters • Alarm display

• The Rhoss Multichiller Sequencer makes it possible to manage water chillers connected in parallel in medium/large HVAC systems. • The optimisation of operating times and the insertion of the individual units is controlled by logics that focus on energy efficiency, guaranteeing reliability over time. • The management mode of the units can be selected from between FL-Full Load Unit Manager (specific for screw compressor water chillers) and PL-Part Load Unit Manager (specific for water chillers with scroll compressors).

• The software at the heart of the system was designed and tested by the Rhoss R&D structure and is able to acquire and manage the main variables of the connected water chillers. The sequencer also interfaces with the main BMS available on the market, guaranteeing complete control in all system types.

50% operation

50% operation

50% operation

50% operation

PL MODE SERIAL NETWORK FL MODE

RHOSS sequencer 100% operation

100% operation

50% operation

Off

Supervision software

RHOSS SUPERVISOR

105

RHOSS SUPERVISOR FOR FAN COIL UNITS AND TERMINAL UNITS:

RHOSS SUPERVISOR allows:  control of unit start-up and shutdown;

RHOSS SUPERVISOR allows:  control of unit start-up and shutdown;

 display and modification of summer/winter operation of the heat pump units;

 display and modification of fan speed;

 display and modification of set-point values;  display of temperature of water coming into and going out of the unit;  display of the three power supply voltages (Y-Pack range, Compact-Y range, Mini-Y range, Q-Pack range);  display of alarms;  scheduling of actions to be performed in the event of an alarm in a unit. In fact, it is possible to send a fax or e-mail with all information required for remote service of the cooling unit.  scheduling/programming of periodic maintenance.

 display and modification of operating mode (Auto, Cool, Dry, Fan, Heat, Heater);  display and modification of set-point values;  display of alarms;  scheduling of actions to be performed in the event of an alarm in a unit. In fact, it is possible to send a fax or e-mail with all information on the event);  set daily time zones with start/stop function, modification of setpoint and setting of operating mode.

RHOSS SUPERVISOR RHOSS supervision software

RHOSS SUPERVISOR FOR CHILLERS AND HEAT PUMPS

iDRHOSS Integrated solutions for system management PAG. 108

• RHOSS SUPERVISOR is easy to use both in terms of system configuration and access to characteristic unit parameters because it uses the Microsoft Internet Explorer interface.

• RHOSS SUPERVISOR makes it possible to set up a local supervision system via serial connection of the microprocessor cards of the RHOSS units to a computer. If the local computer is connected to the information system network of the building (Ethernet with TCP/IP protocol), the information can be shared with any other computer on the network. Supervision can also be carried out remotely via GSM modem connection. In both cases, access to supervisor information can be protected by various levels of password.

• RHOSS SUPERVISOR is the Rhoss supervision system that allows monitoring and remote management of Rhoss units used in a hydronic system. This makes it possible to monitor, via a computer, the operation of Rhoss chillers, heat pumps or terminal units, or the entire iDRHOSS integrated hydronics system.

RHOSS SEQUENCER Water chiller management software

SELECTION SOFTWARE for Chillers - Fan-coils PAG. 20

• RHOSS hydronic unit monitoring and remote control • Local supervision on the computer • Remove management via the GSM modem

Integrated solutions for system management 106

• iDRHOSS is an advanced system for the management of hydronic air conditioning systems, developed to meet the comfort needs of any civil or residential location. • iDRHOSS offers a series of functions, such as centralized management, automatic summerwinter changeover and operating times, whilst always working towards energy saving.

Controls for terminal units

Flush panel

Area terminal The control panel for centralized management of all the units in the system.

Recessed panel Wall-mounted receiver

Remote control

Chiller

SELECTION SOFTWARE for Chillers - Fan-coils PAG. 20

107

iDRHOSS SYSTEM AREA CONTROLLER FUNCTIONS  Start-up and/or shutdown of the entire system (chiller/heat pump and terminal units).

 Centralised management of a number of zones and modification of the terminal units (ON/OFF, set-point, operating mode, fan speed, sleep/economy mode).  Management of daily and weekly time bands (ON/OFF) for the terminals, different for each zone, and for the chiller/heat pump with possible variations of set-point.  Automatic seasonal switchover and real time status and system operating display in real time (ON/ON by timer - OFF/OFF by timer - OFF by alarm, SUMMER/WINTER/BOILER).

RHOSS SEQUENCER Software for managing chillers PAG. 106

 Display and modification of central unit parameters.

 Automatic boiler management (and of any bypass valve on the water system) in the event of shutdown of the heat pump.

 Display and setting of current date and time.  Configuration of the serial network and of the terminals installed in the zones.

FAN COIL UNITS AND TERMINAL UNITS BrioEV

YardyEV

YardyDUCT

YardyHP

UTNC-EV

UTNB

UTNA

iDRHOSS Integrated solutions for system management

 Display for the main unit and for the terminal units of possible alarm conditions (identified by a code and corresponding description).

RHOSS SUPERVISOR Rhoss supervision software PAG. 107

 Start-up and shutdown by GSM.

CONTROLS for fan coil units and terminal units

£ KCV2

wall mounted

X

£ KTCV2 wall mounted £ KBTCV2 - Y TCV2

X

X

X

X

£ KTCVA wall mounted £ KBTCVA - Y TCVA

X

X

X

X

AUTOMATIC SPEED

REGULATION ±5°C

X

X

Control interface for 4 fan coil units

4-pipe systems

2-pipe systems

Continuous/ thermostatcontrolled ventilation

X

X

Electric heater control

X

£ KTA - Y TATM

ON/OFF valves control

X

X

Summer/winter switch

X

Air sensor with remote control option

X

£ KC - Y C on board KC

Minimum thermostat

INSTALLATION:

Room thermostat

STANDARD CONTROLS

3-speed ON/OFF switch

108

C

on board KTA

TATM

X

KCV2

X

X

AUTOMATIC

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Serial interface.

INSTALLATION:

X

X

Electric heater

CONTROLS

X

SPEED MINIMUM

X

ON/OFF valves control

on board

X

4-pipe systems

KTCVR

X

AUTOMATIC

X

2-pipe systems

£ KTCVR wall mounted £ KBTCVR - Y TCVR

X

Master/slave function

on board

X

Comfort functions

KTCVA

on board

Regulation functions

KTCV2

£ Y Electronic on board panel

£ Y Master on board electronic card

£ Wall-mounted electronic panel

£ Y MASTER electronic card

£ Recessed electronic panel

£ Y MASTER electronic card

£ Remote control £ Y MASTER electronic card

RICEVITORE

£ Y On board or wall mounted receiver

£ Y SLAVE electronic card

Additional modules:

£ Y Probe for additional coil £ Y ON/OFF valve module £ Y Electric heater module

Key: Y Factory fitted £ Supplied loose

X X X

X X X

DRY Dehumidification.

ON/OFF remote control Remote start-up and shutdown.

FAN - AUTOFAN Manual/automatic ventilation.

SUMMER/WINTER remote control Summer/winter remote signal

HEAT (HEAT+ELECTRIC HEATER) Heating (Heating with electrical heater).

SECURITY control External security (window contact).

COMFORT FUNCTIONS

PROBE IN/PROBE OUT Remote working probe.

ORIENTING/SWING Fixed/swinging louver.

CONTINUOUS VENTILATION Continuous ventilation thermostat.

CONT SLAVE 1

SLAVE 2

SLAVE 3

SLAVE 99

MASTER

CLOCK Display of set time.

COMFORT CONTROL Regulation +/- 3°C

TIMER Programmed on/off.

OCCUPANCY Occupancy for hotel rooms

SLEEP Night-time air conditioning.

ALARM Alarm signals.

HOT START Winter on/off signal

MASTER - SLAVE Master/slave function

• Centralised management of a maximum of 5 SLAVE units via a single MASTER unit without a serial interface.

TOO COOL Summer on/off signal.

MASTER/SLAVE FUNCTION - 100 units

MEMORY Memorisation of operating mode.

• Centralised management of a maximum of 99 SLAVE units via a single MASTER unit without a serial interface.

SYSTEM ACCESSORIES

MASTER/SLAVE FUNCTION - 6 units

FAN COIL UNITS AND TERMINAL UNITS BrioEV

YardyEV

YardyDUCT

YardyHP

UTNC-EV

UTNB

UTNA

AIR cooled AXIAL fans AIR cooled CENTRIFUGAL fans

LOCK FUNCTION Locked operation for hotel room.

WATER cooled CONDENSERLESS UNITS

COOL Cooling.

WATER CHILLERS HEAT PUMPS

ECONOMY (ECO) Energy savings.

WATER CHILLERS HEAT PUMPS

FULL AUTO Automatic management.

INDUSTRIAL & PROCESS COOLING

ADVANCED FUNCTIONS

EXP Polyvalent systems

MASTER/SLAVE FUNCTION

REGULATION FUNCTIONS

CONTROLSFAN COIL UNITS for fan coil units and terminal units

RECEIVER

CONDENSING UNITS

ELECTRONIC CONTROL FOR TERMINAL UNITS

WATER CHILLERS HEAT PUMPS

109

110 Cooling capacity: 1.9÷3.9 kW - Heating capacity: 2.5÷5.4 kW

• New range with display • Reduced wall mounted dimensions • On board 3-way valve Remote control



Wall-mounted control panel

Hi-wall fan coil. Construction features • Heat exchanger: with finned coil. • Fan: tangential 3-speed. • Louver: motorised with different positions. • Control: microprocessor electronic control. • Regulation functions: full auto, cool, dry, fan, autofan, heat. • Comfort functions: orienting, swing, timer, sleep, hot start, memory. • Master/slave function for managing a total of up to 32 units. • Structure: in heat-resistant ABS polymer complete with renewable polypropylene filter, direction-adjustable fins and condensation drain pan with natural drainage. • Remote control supplied as standard.

Versions • MPCV - Heating and cooling unit complete with 3-way ON/OFF valve.

ACCESSORIES

£ Recessed box.

CONTROLS

£ Electronic control panel for wall mounting. Key: Y Factory fitted £ Supplied loose SLAVE 1

SLAVE 2

SLAVE 3

SLAVE 31

MASTER

MANAGEMENT OF UP TO 32 UNITS VIA A MASTER/SLAVE CONNECTION

3,87

MED

kW

1,82

2,51

2,80

3,30

MIN

kW

1,70

1,92

2,28

2,69

MAX

kW

2,54

4,01

4,64

5,36

MED

kW

2,50

3,44

3,95

4,62

MIN

kW

2,30

2,71

3,17

3,84

‡ Heating capacity (70°C)

MAX

kW

4,22

6,27

7,03

8,56

Air flow speed

MAX

m/h

480

680

710

825

MED

m/h

385

482

570

630

MIN

m/h

310

350

480

530

MAX

dB(A)

50

53

53

54

MED

dB(A)

45

46

47

47

MIN

dB(A)

39

41

43

44

MAX

dB(A)

42

45

45

46

MED

dB(A)

37

38

39

39

MIN

dB(A)

31

33

35

36

W

30

49

58

64

230-1-50

230-1-50

230-1-50

230-1-50

† Heating capacity (50°C)

Sound power level

ˆ Sound pressure speed

Maximum absorbed power Main supply

V-ph-Hz

DIMENSIONS AND WEIGHTS

20

30

35

40

mm

800

1.010

1.090

1.090

H - Height

mm

285

320

330

330

D - Depth

mm

215

225

250

250

kg

11

14

15

15

W - Width

Weight

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. † Air: 20°C - Water: 50°C, flow rate as in cooling. ‡ Air: 20°C - Water: 70/60°C. ˆ At 1 m from air outlet with directionality factor of 2.

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING

3,35

EXP Polyvalent systems

40

2,95

CONDENSING UNITS

35

1,89

SYSTEM ACCESSORIES

30

kW

FAN COIL UNITS

P R E L I M I N A R Y

20 MAX

… Total cooling capacity

TERMINAL UNITS

Idrowall MODEL

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

111

112 Cooling capacity: 1÷6.9 kW - Heating capacity: 1.3÷16.5 kW

• Exclusive design • Wide range of colours • Adjustable outlet grille • Acoustic comfort • Remote control

Floor and ceiling fan coil units with cabinet. Construction features • Heat exchanger: with finned coil with left-hand connections reversible to right. • Fan: centrifugal 3-speed. • Structure: cover panel in painted galvanized sheet metal complete with renewable filter and condensation drain pan with natural drainage; direction-adjustable grilles in heat-resistant ABS polymer.

Versions • MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. • MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation. • MOP - Horizontal unit with cabinet equipped with rear air inlet and front outlet for ceiling installation. • MOT - Horizontal unit with cabinet equipped with lower air inlet and front outlet for ceiling installation.

ACCESSORIES

£YAdditional water heating coil. £YElectric heater. £YValve and balancing valve. £YON/OFF 2-way valves for 2 and 4-pipe-systems. £YON/OFF 3-way valves for 2 andr 4-pipe-systems. £YAuxiliary condensation drain pan. £ Manual damper. £ Motorized damper.

Recessed control panel



Remote control



Wall-mounted control panel

For installation on machine ( MVP and MVT versions)

£YPanel with speed switch. £YPanel with room thermostat, summer/winter switch and speed switch. £YMinimum temperature thermostat. £YPanel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater.

For installation on machine. £YMaster/slave electronic card. £YTemperature probe for hot row. £YModule for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.

Key: Y Factory fitted £ Supplied loose

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING EXP Polyvalent systems

£ On board remote control and receiver. £ Electronic panel for wall or onboard mounting. £ Recessed electronic panel.

CONDENSING UNITS

CONTROLS

SYSTEM ACCESSORIES

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. £ Minimum temperature thermostat (for installation on the machine). £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.

FAN COIL UNITS

STANDARD CONTROLS For wall installation

£YElectronic panel with automatic summer/winter changeover for 2-pipe systems. £YElectronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £Interface card for controlling up to 4 fan coil units.

TERMINAL UNITS

£ Rear panel. £ Rear closure panel. £ Rear closure panel with grille and filter. £ Support feet with pipe cover.

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

113

114 Cooling capacity: 1÷6,9 kW - Heating capacity: 1,3÷16,5 kW

• Exclusive design • Wide range of colours • Adjustable outlet grille • Acoustic comfort • Remote control

VERSIONS:

RANGE OF COLOURS:

STANDARD

RHOSS special colours (*)

PEARL WHITE

BI-COLOUR

METALLIC SILVER GREY

METALLIC NIGHT BLUE

MONO-COLOUR

SATIN-FINISH BRONZE

GRAPHITE BLACK

COLORI RAL (*) Customised Scelta personalizzata colour selection del colore È possibile It is possiblescegliere to choose il colore the desired desiderato colourall’interno from the dellarange. RAL gamma I.e.RAL. Es. RAL 2000

METALLIC PURPLE

(*)The RHOSS special colours and the RAL colours are available with BI-COLOUR and MONO-COLOUR set-up.

35

40

50

60

70

2,16

2,71

3,26

3,91

4,71

5,92

6,92

MED

kW

0,74

1,14

1,49

1,95

2,37

2,74

3,12

3,78

5,11

5,97

MIN

kW

0,62

1,09

1,14

1,56

1,71

1,99

2,70

3,23

4,28

5,51

MAX

kW

1,30

1,82

2,52

2,99

3,67

4,24

4,79

6,08

7,83

9,58

MED

kW

1,02

1,42

2,00

2,58

2,99

3,61

3,91

4,64

6,70

8,65

MIN

kW

0,80

1,26

1,56

2,08

2,26

2,79

3,19

4,02

5,87

7,83

† Heating capacity (70°C)

MAX

kW

2,21

3,39

4,30

5,12

6,27

7,22

8,07

10,37

13,33

16,49

† Heating capacity

MAX

kW

1,34

1,96

2,05

2,78

2,99

3,81

4,03

5,46

5,87

6,52

additional coil

MED

kW

1,15

1,64

1,81

2,37

2,55

3,40

3,40

4,53

5,67

6,20

MIN

kW

0,98

1,47

1,51

1,96

2,06

2,88

3,00

4,02

5,56

5,64

MAX

m/h

183

238

339

405

483

587

627

916

1.109

1.388

MED

m/h

138

177

238

339

383

472

474

662

882

1.171

MIN

m/h

100

155

177

252

281

365

392

537

757

994

MAX

dB(A)

40

41

48

42

47

48

50

56

60

65

MED

dB(A)

33

34

40

37

42

43

43

47

54

60

MIN

dB(A)

30

31

32

29

34

35

39

41

50

57

MAX

dB(A)

32

33

40

34

39

40

42

48

52

57

MED

dB(A)

25

26

32

29

34

35

35

39

46

52

MIN

dB(A)

22

23

24

21

26

27

31

33

42

49

W

26

23

38

34

54

58

61

95

139

161

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

15

20

22

25

30

35

40

50

60

70

mm

700

800

800

1.000

1.000

1.200

1.200

1.500

1.500

1.500

H - Height

mm

583

583

583

583

583

583

583

583

583

583

Height of feet

mm

100

100

100

100

100

100

100

100

100

100

D - Depth

mm

220

220

220

220

220

220

220

220

220

220

kg

16

20

20

20

22

27

28

35

35

36

Air flow speed

Sound power level

ˆ Sound pressure speed

Maximum absorbed power Main supply

V-ph-Hz

DIMENSIONS AND WEIGHTS W - Width

Weight MOP

MOT

MVP

P H L

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. † Air: 20°C - Water: 50°C, flow rate as in cooling. ‡ Air: 20°C - Water: 70/60°C. ˆ At 1 m from air outlet with directionality factor of 2.

MVP+feet

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS MVT

TERMINAL UNITS

† Heating capacity (50°C)

INDUSTRIAL & PROCESS COOLING

30

1,92

EXP Polyvalent systems

25

1,49

CONDENSING UNITS

22

0,94

SYSTEM ACCESSORIES

20

kW

… Total cooling capacity

FAN COIL UNITS

15 MAX

BrioEV MODEL

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

115

116 Cooling capacity: 1÷7.2 kW - Heating capacity: 1.4÷17.4 kW

• Installation flexibility • Acoustic comfort • Preinstalled accessories and controls

Floor and ceiling fan coil units with cabinet. Construction features • Heat exchanger: with finned coil with left-hand connections reversible to right. • Centrifugal fan: 3-speed. • Structure: covering cabinet in pre-painted sheet metal complete with renewable filter, grilles in ABS polymer and condensation drain pan with natural drainage.

Versions • MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. • MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation. • MOP - Horizontal unit with cabinet equipped with rear air inlet and front outlet for ceiling installation. • MOT - Horizontal unit with cabinet equipped with lower air inlet and front outlet for ceiling installation.

ACCESSORIES

£YAdditional water heating coil. £YElectric heater. £YValve and balancing valve. £YON/OFF 2-way valves for 2 and 4-pipe-systems. £YON/OFF 3-way valves for 2 andr 4-pipe-systems. £YAuxiliary condensation drain pan. £ Manual damper. £ Motorized damper. £ Rear panel. £ Rear closure panel. £ Rear closure panel with grille and filter. £ Support feet with pipe cover.

STANDARD CONTROLS For wall installation

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed

switch, ON/OFF valve signal and electric heater. £ Minimum temperature thermostat (for installation on the machine). £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.

For installation on machine ( MVP and MVT versions)

£YPanel with speed switch. £YPanel with room thermostat, summer/winter switch and speed switch. £YMinimum temperature thermostat. £YPanel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. £YElectronic panel with automatic summer/winter changeover for 2-pipe systems. £YElectronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £Interface card for controlling up to 4 fan coil units.

CONTROLS

£ Remote control receiver. £ Electronic panel for wall or onboard mounting. £ Recessed electronic panel.

For installation on machine.

£YMaster/slave electronic card. £YTemperature probe for hot row. £YModule for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Y Factory fitted £ Supplied loose

35

40

45

55

65

75

1,92

2,42

2,96

3,61

4,12

5,23

6,37

7,20

MED

kW

0,87

1,32

1,49

1,95

2,49

2,74

3,19

4,27

5,28

5,97

MIN

kW

0,62

1,09

1,14

1,56

2,00

2,38

2,89

3,78

4,28

5,51

MAX

kW

1,41

2,20

2,52

3,30

3,82

4,87

5,25

6,83

8,36

10,1

MED

kW

1,19

1,66

2,22

2,58

3,20

3,61

3,91

5,47

6,90

8,65

MIN

kW

0,80

1,39

1,56

2,08

2,54

3,10

3,61

4,64

5,87

7,83

‡ Heating capacity (70°C)

MAX

kW

2,40

3,74

4,30

5,66

6,51

8,32

8,88

11,70

14,23

17,37

† Heating capacity

MAX

kW

1,40

2,16

2,07

3,01

3,23

3,91

3,91

6,08

6,29

6,78

additional coil

MED

kW

1,16

1,72

1,74

2,55

2,77

3,40

3,40

5,13

5,77

6,18

MIN

kW

0,98

1,47

1,44

2,06

2,29

3,02

3,04

4,53

5,56

5,61

MAX

m/h

209

288

339

484

547

676

681

1.077

1.235

1.480

MED

m/h

163

207

238

339

434

472

474

802

948

1.171

MIN

m/h

100

155

177

252

329

390

431

662

757

994

MAX

dB(A)

43

44

50

48

50

51

52

58

62

66

MED

dB(A)

35

35

40

38

45

43

43

52

56

61

MIN

dB(A)

26

30

34

30

39

38

41

47

50

57

MAX

dB(A)

35

36

42

40

42

43

44

50

54

58

MED

dB(A)

27

27

32

30

37

35

35

44

48

53

MIN

dB(A)

18

22

26

22

31

30

33

39

42

49

W

32

30

38

45

60

72

70

115

161

184

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

15

20

22

25

35

40

45

55

65

75

mm

700

800

800

1.000

1.000

1.200

1.200

1.500

1.500

1.500

H - Height

mm

570

570

570

570

570

570

570

570

570

570

Height of feet

mm

100

100

100

100

100

100

100

100

100

100

D - Depth

mm

220

220

220

220

220

220

220

220

220

220

kg

16

20

20

20

21

27

28

35

35

37

† Heating capacity (50°C)

Air flow speed

Sound power level

ˆ Sound pressure speed

Maximum absorbed power Main supply

V-ph-Hz

DIMENSIONS AND WEIGHTS W - Width

Weight

MOT

MVP

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. † Air: 20°C - Water: 50°C, flow rate as in cooling. ‡ Air: 20°C - Water: 70/60°C. ˆ At 1 m from air outlet with directionality factor of 2.

MVP+feet

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS MVT

TERMINAL UNITS

MOP

INDUSTRIAL & PROCESS COOLING

25

1,71

EXP Polyvalent systems

22

1,02

CONDENSING UNITS

20

kW

SYSTEM ACCESSORIES

15

MAX

YardyEV MOP-MOT-MVP-MVT MODEL … Total cooling capacity

FAN COIL UNITS

RECEIVER

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

117

118 Cooling capacity: 1÷7.2 kW - Heating capacity: 1.4÷17.4 kW

• Installation flexibility • Acoustic comfort • Preinstalled accessories and controls

Recessed or false ceiling fan coil units Construction features • Heat exchanger: with finned coil with left-hand connections reversible to right. • Centrifugal fan: 3-speed. • Structure: in galvanized sheet steel, complete with condensation drain pan with natural drainage and renewable filter.

Versions • IVP - Recessed vertical unit equipped with lower air inlet and upper outlet for wall installation. • IVF - Recessed vertical unit equipped with lower air inlet and front outlet for wall installation. • IOP - Recessed horizontal unit equipped with rear air inlet and front outlet for ceiling installation.

ACCESSORIES

£YAdditional water heating coil. £YElectric heater. £YValve and balancing valve. £YON/OFF 2-way valves for 2 and 4-pipe-systems. £YON/OFF 3-way valves for 2 and 4-pipe-systems. £YAuxiliary condensation drain pan. £ Motorized damper. £ Frame with filter (G2) that can be extracted in any direction. £ Straight outlet and inlet connection. £ 90° outlet and inlet connection. £ Telescopic outlet/inlet connection. £ Inlet grille with filter. £ Outlet grille. £ Cover panel with grilles (only IVF and IOP).

STANDARD CONTROLS For wall installation

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. £ Minimum temperature thermostat (for installation on the machine). £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £ Interface card for controlling up to 4 fan coil units (for on board installation)

CONTROLS

£ Remote control receiver. £ Electronic control panel for wall mounting. £ Recessed electronic panel.

For installation on machine.

£YMaster/slave electronic card. £YTemperature probe for hot row. £YModule for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Y Factory fitted £ Supplied loose

RECEIVER

Recessed control panel



Remove control with wall-mounted receiver



Wall-mounted control panel

40

45

55

65

75

2,42

2,96

3,61

4,12

5,23

6,37

7,20

MED

kW

0,87

1,32

1,49

1,95

2,49

2,74

3,19

4,27

5,28

5,97

MIN

kW

0,62

1,09

1,14

1,56

2,00

2,38

2,89

3,78

4,28

5,51

MAX

kW

1,41

2,20

2,52

3,30

3,82

4,87

5,25

6,83

8,36

10,1

MED

kW

1,19

1,66

2,22

2,58

3,20

3,61

3,91

5,47

6,90

8,65

MIN

kW

0,80

1,39

1,56

2,08

2,54

3,10

3,61

4,64

5,87

7,83

‡ Heating capacity (70°C)

MAX

kW

2,40

3,74

4,30

5,66

6,51

8,32

8,88

11,70

14,23

17,37

† Heating capacity

MAX

kW

1,40

2,16

2,07

3,01

3,23

3,91

3,91

6,08

6,29

6,78

additional coil

MED

kW

1,16

1,72

1,74

2,55

2,77

3,40

3,40

5,13

5,77

6,18

MIN

kW

0,98

1,47

1,44

2,06

2,29

3,02

3,04

4,53

5,56

5,61

MAX

m/h

209

288

339

484

547

676

681

1.077

1.235

1.480

MED

m/h

163

207

238

339

434

472

474

802

948

1.171

MIN

m/h

100

155

177

252

329

390

431

662

757

994

MAX

dB(A)

43

44

50

48

50

51

52

58

62

66

MED

dB(A)

35

35

40

38

45

43

43

52

56

61

MIN

dB(A)

26

30

34

30

39

38

41

47

50

57

MAX

dB(A)

35

36

42

40

42

43

44

50

54

58

MED

dB(A)

27

27

32

30

37

35

35

44

48

53

MIN

dB(A)

18

22

26

22

31

30

33

39

42

49

W

32

30

38

45

60

72

70

115

161

184

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

15

20

22

25

35

40

45

55

65

75

mm

450

550

550

750

750

950

950

1.250

1.250

1.250

H - Height

mm

545

545

545

545

545

545

545

545

545

545

D - Depth

mm

212

212

212

212

212

212

212

212

212

212

kg

14,5

16,5

16,5

20,5

20,5

24,0

25,5

34,5

34,5

36,5

† Heating capacity (50°C)

Air flow speed

Sound power level

ˆ Sound pressure speed

Maximum absorbed power Main supply

V-ph-Hz

DIMENSIONS AND WEIGHTS W - Width

Weight

IVP

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. † Air: 20°C - Water: 50°C, flow rate as in cooling. ‡ Air: 20°C - Water: 70/60°C. ˆ At 1 m from air outlet with directionality factor of 2.

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS IVF

TERMINAL UNITS

IOP

INDUSTRIAL & PROCESS COOLING

35

1,92

EXP Polyvalent systems

25

1,71

CONDENSING UNITS

22

1,02

SYSTEM ACCESSORIES

20

kW

FAN COIL UNITS

15

MAX

YardyEV IOP-IVP-IVF MODEL … Total cooling capacity

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

119

120 Cooling capacity: 2÷5.1 kW - Heating capacity: 2.4÷12 kW

• Vertical and horizontal installation • Six selectable speeds • Remote control

Ductable fan coil units for built in horizontal or vertical installation. Construction features • Heat exchanger: with finned coil with left-hand connections reversible to right. • Centrifugal fan: 6-speed. • Structure: in galvanized sheet steel, complete with condensation drain pan with natural drainage and renewable filter.

ACCESSORIES

£YAdditional water heating coil. £YElectric heater. £YValve and balancing valve. £YON/OFF 2-way valves for 2 and 4-pipe-systems. £YON/OFF 3-way valves for 2 and 4-pipe-systems. £YAuxiliary condensation drain pan. £ Motorized damper. £ Flanged frame for connection to the inlet or outlet duct. £ Frame with filter (G2) that can be extracted in any direction. £ Straight outlet and inlet connection. £ 90° outlet and inlet connection. £ Telescopic outlet/inlet connection. £ Inlet grille with filter. £ Outlet grille. £ Antivibration connection for connection to the inlet or outlet duct. £ Inlet/outlet plenum with circular nozzles.

STANDARD CONTROLS For wall installation

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. £ Minimum temperature thermostat (for installation on the machine). £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £ Interface card for controlling up to 4 fan coil units (for on board installation).

CONTROLS

£ Remote control receiver. £ Electronic control panel for wall mounting. £ Recessed electronic panel.

For installation on machine.

£YMaster/slave electronic card. £YTemperature probe for hot row. £YModule for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Y Factory fitted £ Supplied loose

RECEIVER

Recessed control panel



Remove control with wall-mounted receiver



Wall-mounted control panel

not ducted

not ducted

(Speed)

4,12 (VI)

1,97 (VI)

5,23 (VI)

2,70 (VI)

6,37 (VI)

3,94 (VI)

7,20 (VI)

5,10 (VI)

kW

(Speed)

3,19 (V)

1,82

(V)

4,27 (IV)

2,32 (IV)

5,28 (IV)

3,27 (IV)

5,97 (IV)

4,57 (IV)

kW

(Speed)

2,89 (III)

1,21 (III)

3,78 (II)

1,62

4,28

2,48

5,51

4,18

kW

(Speed)

5,25 (VI)

2,42 (VI)

6,83 (VI)

3,46 (VI)

8,36 (VI)

5,18 (VI)

10,10 (VI)

7,06 (VI)

kW

(Speed)

3,91 (V)

2,22

(V)

5,47 (IV)

3,01 (IV)

6,90 (IV)

4,30 (IV)

8,65 (IV)

6,50 (IV)

kW

(Speed)

3,61 (III)

1,42 (III)

4,64 (II)

2,05

5,87

3,39

7,83

kW

(Speed)

8,88 (VI)

4,06 (VI)

11,70 (VI)

5,91 (VI)

‡ Heating capacity (70°C)

kW

(Speed)

3,91 (VI)

2,21 (VI)

6,08 (VI)

4,42 (VI)

6,29 (VI)

4,39 (VI)

6,78 (VI)

5,18 (VI)

of additional coil

kW

(Speed)

3,40 (V)

2,08

5,13 (IV)

3,56 (IV)

5,77 (IV)

4,07 (IV)

6,18 (IV)

4,99 (IV)



kW

(Speed)

3,04 (III)

1,50 (III)

4,53 (II)

Air flow/static pressure

kW

(Speed)

681 / 0 (VI)

275 / 55 (VI)

1077 / 0(VI)

kW

(Speed)

474 / 0 (V)

250 / 50 (V)

802 / 0 (IV)

382 / 50 (IV)

kW

(Speed)

431 / 0 (III)

155 / 30 (III)

662 / 0 (II)

250 / 30 (II)

dB(A)

(Speed)

dB(A) dB(A)

† Heating capacity (50°C)

‡ Heating capacity (70°C)

ˆ Sound power level

‰ Sound pressure level

(V)

2,40

(II)

(II)

450 / 65 (VI)

(II)

(II)

14,23 (VI)

5,56

(II)

8,84 (VI)

(II)

1235 / 0 (VI)

(II)

3,71

(II)

(II)

(II)

5,88

17,37 (VI)

5,61

(II)

4,73

938 / 60 (VI)

948 / 0 (IV)

539 / 50 (IV)

1171 / 0 (IV)

820 / 50 (IV)

757 / 0 (II)

400 / 40 (II)

994 / 0 (II)

751 / 35 (II)

66 (VI)

(Speed)

43 (V)

52 (IV)

56 (IV)

61 (IV)

(Speed)

41 (III)

47 (II)

50 (II)

57 (II)

dB(A)

(Speed)

44 (VI)

50 (VI)

54 (VI)

58 (VI)

dB(A)

(Speed)

35 (V)

44 (IV)

48 (IV)

53 (IV)

dB(A)

(Speed)

33 (III)

39 (II)

42 (II)

49 (II)

70

115

161

184

230-1-50

230-1-50

230-1-50

230-1-50

V-ph-Hz

(II)

1480 / 0 (VI)

62 (VI)

Main supply

(II)

683 / 60 (VI)

58 (VI)

W

(II)

DIMENSIONS AND WEIGHTS

40

50

60

70

W - Width

mm

950

1.250

1.250

1.250

H - Height

mm

545

545

545

545

D - Depth

mm

212

212

212

212

Weight

kg

25,5

34,5

34,5

36,5

DUCT

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C, data referred to 3 speed on 6 available. † Air: 20°C - Water: 50°C, flow rate as in cooling, data referred to 3 speed on 6 available. ‡ Air: 20°C - Water: 70/60°C, data referred to 3 speed on 6 available. ˆ Non-ducted unit. ‰ At 1 m from air outlet with directionality factor of 2.

HORIZONTAL installation VERTICAL installation

AIR cooled AXIAL fans AIR cooled CENTRIFUGAL fans

12,07 (VI)

52 (VI)

Maximum absorbed power

WATER cooled CONDENSERLESS UNITS

ducted

kW

(II)

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING

70 ducted

EXP Polyvalent systems

ducted

TERMINAL UNITS

P R E L I M I N A R Y

60

not ducted

CONDENSING UNITS

… Total cooling capacity

ducted

SYSTEM ACCESSORIES

50

not ducted

FAN COIL UNITS

40

MODEL YardyEV DUCT

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

121

122 Cooling capacity: 7.2÷20.5 kW - Heating capacity: 9.6÷32.8 kW

• Vertical and horizontal installation • Filters with different efficiency class • Remote control

RECEIVER

Recessed control panel



Remove control with wall-mounted receiver



Wall-mounted control panel

HORIZONTAL installation

VERTICAL installation

High static pressure, ductable fan coil unit for recessed horizontal or vertical installation. Construction features • Heat exchanger: with finned coil with left-hand connections reversible to right. • Centrifugal fan: 3-speed. • Structure: load-bearing, in galvanised sheet metal for horizontal installation in a false ceiling or vertical recessed installation, complete with naturally draining condensation collection pan and connection for attachment to inlet and outlet duct

Versions • BA-3R - Unit with 3-row coil. • BA-4R - Unit with 4-row coil. • BA-5R - Unit with 5-row coil (for mod. 250-300 only).

ACCESSORIES

£YElectrical box for connection terminal board. £YAdditional water heating coil (1 row) for 4-pipe systems (KBAA for version BA-3R only). £ External plenum with additional water heating coil for 4-pipe systems (PBAB).

£YON/OFF 2-way valves for 2-pipe and 4-pipe systems. £YOn/OFF 3-way valves for 2-pipe and 4-pipe systems. £YAuxiliary condensation drain pan. £ Frame with filter that can be extracted in any direction (efficiency rating G1/G2/G3). £ Straight outlet and inlet connection. £ 90° outlet and inlet connection. £ Flange for connection to duct. £ Antivibration connection for connection to the inlet/outlet duct. £ Panel with circular nozzles to be connected to the outlet/inlet connections.

STANDARD CONTROLS For wall installation

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £ Air sensor with remote control option. £ Interface card for controlling up to 4 fan coil units (models 100150-200 only, for on board installation).

CONTROLS

£ Remote control receiver. £ Electronic control panel for wall mounting. £ Recessed electronic panel.

For installation on machine.

£YMaster/slave electronic card. £YTemperature probe for hot row. £YModule for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU) £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Y Factory fitted £ Supplied loose

250

300

10,13

13,53

15,23 21,79

† Heating capacity (50°C)

BA-3R

kW

9,62

11,71

14,28

19,06

… Total cooling capacity

BA-4R

kW

8,41

9,51

11,37

16,55

18,75

† Heating capacity (50°C)

BA-4R

kW

10,84

12,71

15,42

22,28

25,70

… Total cooling capacity

BA-5R

kW

-

-

-

18,70

20,50

† Heating capacity (50°C)

BA-5R

kW

-

-

-

24,90

28,04

‡ Heating capacity of additional coil (70°C)

KBAA

kW

6,69

6,78

9,35

10,44

11,31

‡ Heating capacity of additional coil (70°C)

PBAB

kW

12,90

14,14

16,40

29,73

32,77

ˆ Air flow/Speed static pressure (BA-3R)

MAX

m/h

1.552 / 60

1.840 / 60

2.339 / 60

3.312 / 60

3.875 / 60

MED

m/h

1.369 / 50

1.430 / 50

1.717 / 50

2.189 / 50

3.075 / 50

MIN

m/h

1.013 / 35

1.313 / 35

1.414 / 35

1.329 / 35

2.415 / 35

MAX

dB(A)

66

68

68

69

73

MED

dB(A)

64

67

66

65

69

MIN

dB(A)

61

65

63

62

66

MAX

dB(A)

52

54

54

55

59

MED

dB(A)

50

53

52

51

55

MIN

dB(A)

47

51

49

48

52

W

270

340

400

700

710

230-1-50

230-1-50

230-1-50

230-1-50

230-1-51

100

150

200

250

300

mm

1.295

1.295

1.295

1.295

1.295

H - Height

mm

250

250

285

335

335

D - Depth YARDY HP

mm

555

555

670

720

720

D - Depth PBAB

mm

200

200

200

200

200

kg

35

35

44

52

52

‰ Inlet sound power (BA-3R)

‰ Speed sound pressure (BA-3R)

Maximum absorbed power (BA-3R) Main supply

V-ph-Hz

DIMENSIONS AND WEIGHTS W - Width

Weight YARDY HP

KCF Filter holder frame

Yardy HP Base unit

PBAB Plenum with additional coil

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS TERMINAL UNITS

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Maximum speed. † Air: 20°C - Water: 50°C, flow rate as in cooling. Maximum speed. ‡ Air: 20°C - Water: 70/60°C. Maximum speed. ˆ 3-row coil (BA-3R) without filter. ‰ With G2 filter. Š At 2 m from the air outlet point with directionality factor of 2 and G2 filter.

INDUSTRIAL & PROCESS COOLING

200

8,37

EXP Polyvalent systems

150

7,16

CONDENSING UNITS

BA-3R

SYSTEM ACCESSORIES

… Total cooling capacity

FAN COIL UNITS

100 kW

YARDY HP MODEL

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

123

124 Cooling capacity: 2.4÷9.8 kW - Heating capacity: 3.2÷23.8 kW

• Cassette for 2-pipe and 4-pipe systems • Electric heater • Preinstalled 3-way valve on demand

Cassette-type fan coil units

STANDARD CONTROLS For wall installation

• Fan coils: cassette-type for installation in false ceilings, with air inlet and outlet directly into the room. • Heat exchanger: with finned coil. • Fan: 3-speed. • Structure: load-bearing, in galvanised sheet metal, complete with condensation drain pump (up to 200 mm above the unit). • Air supply panel: in ABS polymer with manually adjustable outlet fins, inlet grille and renewable filter.

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £Interface card for controlling up to 4 fan coil units.

Versions

CONTROLS

Construction features

• Standard - for 2-pipes-systems . • B4 - for 4-pipe systems. • REL - for 2-pipes-systems supplementary electric heater.

£ Remote control. £ Electronic control panel for wall mounting. £ Recessed electronic panel.

FACTORY FITTED ACCESSORIES

For installation on machine.

• ON/OFF 3-way valves for 2-pipe and 4-pipe-systems and auxiliary pan.

ACCESSORIES SUPPLIED LOOSE • ON/OFF 3-way valves for 2-pipe and 4-pipe-systems and auxiliary pan. • Primary air kit. • Auxiliary condensation drain pan. • Outlet nozzle lock. • Photocatalytic and passive electrostatic filter.

£ Master/slave electronic card. £ Temperature probe for hot row. £ Module for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU) £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: £ Supplied loose

Recessed control panel



Remote control with bracket for wall installation



Wall-mounted control panel

40

50

UTNC/B4 UTNC-UTNC/REL UTNC-UTNC/REL UTNC-UTNC/REL 50

60

85

110

UTNC/B4 110

4,70

4,00

6,30

7,60

10,0

9,80

MAX

kW

2,40

1,90

4,00

3,23

MED

kW

1,80

1,43

2,85

2,42

3,5

3,05

4,50

5,10

7,10

7,30

MIN

kW

1,55

1,23

1,90

1,61

2,85

2,50

3,40

3,17

3,90

4,10

MAX

kW

3,15



4,19



6,02



8,11

10,8

12,9



MED

kW

2,49



3,43



4,38



5,87

7,30

9,28



MIN

kW

2,16



2,02



3,69



4,38

4,30

5,01



‡ Heating capacity (70°C)

MAX

kW

5,55



7,03



10,42



13,76

18,36

23,77



† Heating capacity

MAX

kW



1,90



4,25



4,61







8,11

† Heating capacity (50°C)

MED

kW



1,44



3,18



3,50







7,12

MIN

kW



1,24



2,13



2,73







4,60

Electric heater REL

230-1-50 V

kW

1,5



2,5



2,5



3,0

3,0

3,0



Air flow speed

MAX

m/h

662

662

698

698

850

850

1.019

1.217

1.685

1.685

MED

m/h

450

450

490

490

601

601

731

871

1.134

1.134

MIN

m/h

360

360

310

310

472

472

540

529

641

641

MAX

dB(A)

49

49

54

55

59

58

49

56

63

63

MED

dB(A)

38

38

45

45

50

50

41

49

55

55

MIN

dB(A)

34

35

34

33

44

42

36

41

42

42

MAX

dB(A)

41

41

46

47

51

50

41

48

55

55

MED

dB(A)

30

30

37

37

42

42

33

41

47

47

MIN

dB(A)

26

27

26

25

36

34

28

33

34

34

W

70

70

90

85

100

106

90

120

200

200

230-1-50

230-1-50

230-1-50 230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

25

25

50

50

60

85

110

110

additional coil B4

Sound power level

ˆ Sound pressure speed

Maximum absorbed power Main supply

V-ph-Hz

DIMENSIONS AND WEIGHTS W2/H2/D2 - Width/Height/Depth

mm 575/298/575 575/298/575

40

40

575/298/575 575/298/575 575/298/575 575/298/575 825/298/825 825/298/825 825/298/825 825/298/825

720/30/720

720/30/720

720/30/720

720/30/720

960/30/960

960/30/960

Weight UTNC - UTNC/REL

kg

18,5



20



20



37

39

39



Weight UTNC/B4

kg



18,5



20



20







40

Panelling weight

kg

4

4

4

4

4

4

6

6

6

6

W/H/D - Width/Height/Depth mm

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. † Air: 20°C - Water: 50°C, flow rate as in cooling. ‡ Air: 20°C - Water: 70/60°C. ˆ At 1 m from air outlet with directionality factor of 2.

720/30/720 720/30/720

960/30/960 960/30/960

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING

UTNC/B4 UTNC-UTNC/REL

EXP Polyvalent systems

40

CONDENSING UNITS

UTNC-UTNC/REL

25

SYSTEM ACCESSORIES

UTNC/B4

25

FAN COIL UNITS

… Total cooling capacity

UTNC-UTNC/REL

TERMINAL UNITS

UTNC-EV MODEL

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

125

126 Cooling capacity: 2.5÷7.8 kW - Heating capacity: 3.7÷18.7 kW

• Cassette for 2-pipe systems • Motorised adjustable fins • Standard remote control

Cassette-type fan coil units

Versions Standard - for 2-pipes-systems .

Construction features • Fan coils: cassette-type for installation in false ceilings, with air inlet and outlet directly into the room. • Heat exchanger: with finned coil. • Fan: 3-speed. • Structure: load-bearing, in galvanised sheet metal, complete with condensation drain pump (up to 200 mm above the unit) and auxiliary condensation drain pan. • Air supply panel: in ABS polymer (RAL9010) with motorised outlet fins adjustable in various positions, inlet grille and renewable filter. • Remote control: supplied as standard.

ACCESSORIES SUPPLIED LOOSE • 3-way ON/OFF valve for 2-pipe-systems. • Outlet nozzle lock.

STANDARD CONTROLS For wall installation

£Electronic control panel for wall mounting. £ Centralised control panel for up to 64 units via a serial connection, with daily and weekly time band management. £ Serial interface for connection with the control panel (proprietary protocol). Key: £ Supplied loose

MANAGEMENT OF UP TO 64 UNITS VIA A SERIAL CONNECTION Centralised control panel with daily/weekly time bands management.

Air flow speed

Sound power level

ˆ Sound pressure speed

85

kW

2,50

3,06

4,83

5,75

7,83

MED

kW

2,29

2,79

4,57

4,38

7,13

MIN

kW

2,01

2,47

3,95

3,13

5,92

MAX

kW

3,70

4,09

7,20

8,25

11,1

MED

kW

3,40

3,78

6,68

6,24

9,83

MIN

kW

3,28

3,18

5,63

4,90

8,96

MAX

kW

6,18

6,84

9,98

13,81

18,65

MAX

m/h

603

680

914

1.401

1.720

MED

m/h

524

599

842

1.176

1.585

MIN

m/h

416

468

756

967

1.333

MAX

dB(A)

51

52

61

61

62

MED

dB(A)

46

47

59

52

55

MIN

dB(A)

43

43

57

46

54

MAX

dB(A)

43

44

53

53

54

MED

dB(A)

38

39

51

44

47

MIN

dB(A)

32

35

49

38

46

W

69

69

102

118

184

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

25

30

50

60

85

580/254/580

580/254/580

580/254/580

840/240/840

840/310/840

V-ph-Hz

DIMENSIONS AND WEIGHTS W2/H2/D2 - Width/Height/Depth

mm

650/30/650

650/30/650

650/30/650

950/40/950

950/40/950

Weight VTNC

kg

21

21

21

36

40

Panelling weight

kg

3

3

3

6

6

W/H/D - Width/Height/Depth mm

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. † Air: 20°C - Water: 50°C, flow rate as in cooling. ‡ Air: 20°C - Water: 70/60°C. ˆ At 1 m from air outlet with directionality factor of 2.

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING

VTNC

EXP Polyvalent systems

60

MAX

Maximum absorbed power Main supply

VTNC

50

CONDENSING UNITS

‡ Heating capacity (70°C)

VTNC

30

SYSTEM ACCESSORIES

† Heating capacity (50°C)

VTNC

25

FAN COIL UNITS

… Total cooling capacity

VTNC

TERMINAL UNITS

VTNC MODEL

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

127

128

UTNB 011÷017 Cooling capacity: 4.1÷10.5 kW - Heating capacity: 10.3÷23 kW

UTNB: air inlet with inlet panelling and multi-duct outlet.

Ductable terminal air handling units in sections Construction features • Air handling unit: in modules for installation in false ceiling, with ducting or panelling (29 cm in height). • Heat exchanger: with finned coil with right-hand connections reversible to left. • Fan: centrifugal 3-speed (IP44). • Structure: load-bearing in galvanized sheet metal complete with thermo-acoustic insulation, renewable filter, connection for attachment to inlet duct and condensation drain pan with natural drainage.

STANDARD CONTROLS For wall installation £ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal. £ Humidistat panel. £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. £Interface card for controlling up to 4 fan coil units.

CONTROLS

£ Remote control receiver. £ Electronic control panel for wall mounting. £ Recessed electronic panel. For installation on machine. £ Master/slave electronic card. £ Temperature probe for hot row. £ Module for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU) £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.

Accessories supplied loose • Additional water heating coil. • inlet/outlet plenum (KPAM). • Electric coil module of 1.5-3-4.5 kW (KBAE). • Plenum with steam humidifier (KUMI). • Outlet nozzles module (KBOM). • Inlet panelling. • Solid panelling. • Outlet panelling.

Key: £ Supplied loose

RECEIVER

Recessed control panel



Remove control with wall-mounted receiver



Wall-mounted control panel

011 4R

011 6R

014 2R

014 4R

014 6R

017 2R

017 4R

kW

4,11

6,76

7,78

4,82

8,23

9,64

5,14

8,92

10,52

† Heating capacity

kW

10,35

(•)

(•)

12,66

18,83

(•)

13,76

20,78

23,04 13,49

† Heating capacity of additional coil Air flow speed

‡ Sound pressure speed

kW

10,02

10,02

10,02

12,37

12,37

12,37

13,49

13,49

MAX

m/h

1.100

1.100

1.100

1.480

1.480

1.480

1.680

1.680

1.680

MED

m/h

990

990

990

1.260

1.260

1.260

1.440

1.440

1.440

MIN

m/h

850

850

850

1.100

1.100

1.100

1.200

1.200

1.200

MAX

dB(A)

41

41

41

47

47

47

50

50

50

MED

dB(A)

40

40

40

44

44

44

46

46

46

MIN

dB(A)

38

38

38

41

41

41

41

41

41

W

165

165

165

205

205

205

245

245

245

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

230-1-50

011 2R

011 4R

011 6R

014 2R

014 4R

014 6R

017 2R

017 4R

017 6R

Maximum absorbed power Main supply

017 6R

V-ph-Hz

DIMENSIONS AND WEIGHTS W - Width

mm

990

990

990

990

990

990

990

990

990

H - Height

mm

290

290

290

290

290

290

290

290

290

KPAM - Depth

mm

290

290

290

290

290

290

290

290

290

UTNB - Depth

mm

738

738

738

738

738

738

738

738

738

KBAE - Depth

mm

130

130

130

130

130

130

130

130

130

KUMI - Depth

mm

290

290

290

290

290

290

290

290

290

KBOM - Depth

mm

100

100

100

100

100

100

100

100

100

kg

38

42

46

38

42

46

40

44

48

Weight UTNB

In the following conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Maximum speed, with open outlet. † Air: 20°C - Water: 70/60°C. Maximum speed, with open outlet. ‡ At 3 m from the point of air outlet, with open outlet.

(•) Not to be used with water at 70°C, capacities at different temperatures are shown in the technical catalogue.

WATER CHILLERS HEAT PUMPS

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

INDUSTRIAL & PROCESS COOLING

011 2R

… Total cooling capacity

EXP Polyvalent systems

KBOM Outlet nozzles module

CONDENSING UNITS

KUMI Plenum with humidifier

SYSTEM ACCESSORIES

UTNB MODEL

KBAE Electric coil module

FAN COIL UNITS

UTNB Base unit

TERMINAL UNITS

KPAM Inlet/outlet plenum

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

(*) Unit dimensions in combination with KPAM plenum .

AIR cooled AXIAL fans

129

130

UTNA 015÷150 Cooling capacity: 7.2÷108 kW - Heating capacity:11.3÷174 kW Complete composition

KSER Damper

KB2R Additional heating coil

SIL Plenum with silencer

PRV Steam producer

KPBC Panel with circular nozzles PMA Inlet/outlet plenum

BA Coil module

MUV Plenum with humidifier

SV Fan module

Ductable terminal air handling units in sections Construction features • Air handling unit: in sections for horizontal installation either with or without ducting. • Structure: in galvanized steel sheet metal, with fully removable pre-painted sheet metal panelling, complete with selfextinguishing thermo-acoustic insulation. • Module BA 2R, BA 4R, BA 6R: complete with pleated filter in 2 sections with degree of efficiency G3, can be slid out in all directions; heat exchanger with finned coil, with 2 or 4 or 6 rows with reversible right-hand connections; condensation drain pan with natural drainage. • Fan module SV: complete with centrifugal fan with double inlet with motor (IP55) directly coupled, 3-speed for models 015÷038; 2-speed for model 051; with 4-pole single speed motor (4/6 or 4/8 poles on request) coupled by means of trapezoidal belt and variable pulley for models 078-150. • Electrical board: standard for models 051÷150; accessory for models 015÷038.

Accessory modules • Inlet/outlet plenum with pre-cut side outlets (PMA). • Plenum with absorbent cartridge silencer to be placed for inlet or outlet (SIL). • Plenum with steam humidifier and external electric generator (MUV - PRV).

ACCESSORIES SUPPLIED LOOSE • Additional water heating coil to be inserted in module BA. • Supplementary electric heater from 1.5 kW to 36 kW, to be inserted in module BA. • Droplet eliminator for models 078÷150, to be inserted in module BA. • Combined fresh air damper (max 25%) and re-circulation, to be attached to the PMA inlet plenum.

PMA Inlet/outlet plenum

KPBM Panel with outlet nozzle

• Solid pre-cut panel for connection to duct, to be attached to the PMA inlet plenum. • Panel with rectangular outlet nozzle with double row of adjustable fins, to be attached to PMA outlet plenum. • Panel with circular nozzles, to be attached to PMA inlet/outlet plenum (only for models 015÷051). • Manual control for KSER damper. • Electrical panel in waterproof box (IP55 for UTNA 015÷038).

STANDARD CONTROLS For wall installation

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal. £ Humidistat panel. £ Electronic panel with automatic summer/winter changeover for 2-pipe-systems. £ Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.

CONTROLS

£ Remote control receiver. £ Electronic control panel for wall mounting. £ Wall-mounted electronic panel

For installation on machine.

£ Master/slave electronic card. £ Temperature probe for hot row. £ Module for management of ON/OFF valves and electric heater. £ Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU) £ Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. £ Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Y Factory fitted £ Supplied loose

029

038

051

078

107

130

150

20,7

25,8

35,2

57,5

82,6

92,7

106,0

… Cooling capacity

BA 4R

kW

7,2

8,8

13,9

17,3

21,4

41,8

60,6

67,8

77,1

† Heating capacity

BA 4R

kW

18,5

24,0

33,7

42,8

57,6

92,9

133,0

152,0

174,0

… Cooling capacity

BA 6R

kW

9,9

12,5

17,9

22,4

30,9

55,6

82,7

94,4

108,0

† Heating capacity

BA 6R

kW

(•)

(•)

(•)

(•)

(•)

(•)

(•)

(•)

(•)

Electric heater power

230V-1ph-50Hz

kW

1,5-3-4,5

3-4,5-6

4,5-6-9

6-9-12











400V-3ph-50Hz

kW

1,5-3-4,5

3-4,5-6

4,5-6-9

6-9-12

9-12-18

12-18-24

18-24-36

18-24-36

24-36 16.500 (*)

Air flow speed

MAX

m/h

1.800

2.640

3.220

4.260

6.120

8.580 (*)

11.770 (*)

14.300 (*)

MED

m/h

1.370

2.240

2.400

3.500











MIN

m/h

1.060

1.480

1.560

2.850

4.390









ˆ Speed static pressure

MAX

Pa

90

90

90

90

130

170

160

145

140

‡ Speed sound pressure

MAX

dB(A)

50,9

55,6

54,9

59,8

61,5

59,7

61,7

65,4

61,9

MED

dB(A)

44,3

50,2

48,3

55,7











MIN

dB(A)

37,1

42,1

38,7

51,4

54,4









ˆAbsorbed power Main supply

W V-ph-Hz

DIMENSIONS AND WEIGHTS

370

700

700

1.250

1.850

1.500

1.500

2.200

3.000

230-1-50

230-1-50

230-1-50

230-1-50

400-3-50

400-3-50

400-3-50

400-3-50

400-3-50

015

020

029

038

051

078

107

130

150

mm

928

928

1.228

1.228

1.328

1.658

2.058

2.058

2.058

H - Height

mm

398

398

463

518

568

768

918

918

1.018

PMA - Depth

mm

370

370

435

490

540

740

890

890

990

BA - Depth

mm

645

645

645

645

645

910

910

910

910

SV - Depth

mm

370

370

435

490

490

1.040

1.040

1.040

1.040

SIL-MUV - Depth

mm

960

960

960

960

960

1.040

1.040

1.040

1.040

‰ Weight UTNA

kg

51

51

68

71

79

140

200

200

220

W - Width

conditions: … Air: 27°C D.B.; 19°C W.B. - Water: 7/12°C. Maximum speed. † Air: 20°C - Water: 70/60°C. Maximum speed. ‡ At 3 m from the point of air outlet, with open outlet. ˆ 4-row coil (BA 4R) and filter. ‰ Empty weight BA 6R. (•) Not to be used with water at 70°C, capacities at different temperatures are shown in the technical catalogue. (*) Belt transmission with variable ratio.

BA Coil module

SV Fan module

Base composition

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

AIR cooled AXIAL fans

WATER CHILLERS HEAT PUMPS INDUSTRIAL & PROCESS COOLING

020 14,2

EXP Polyvalent systems

015 11,3

CONDENSING UNITS

kW

SYSTEM ACCESSORIES

† Heating. capacity of . additional coil BA 2R/KB2R

FAN COIL UNITS

UTNA MODEL

TERMINAL UNITS

RICEVITORE

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

131

132

UTNR 012÷041 Recovery capacity: 5.4÷18.6 kW

• Horizontal or vertical installation • Coil module for summer or winter integration • Accessories for simple installation Air renewal terminal units with heat recovery. Construction features • Unit for environment air renewal with heat recovery: for horizontal or vertical installation with dedicated accessory (KPAV). • Structure: load-bearing frame with extruded 30-mm aluminium sections, glass-loaded nylon or painted aluminium nylon corners, and seals. • Sandwich panels with a total thickness of 25 mm, in double galvanised sheet steel, hot-injected polyurethane insulation, density 45 kg/m. • Module with recovery unit: aluminium air-air type package recovery unit with rough surface plates, housed in a built-in condensation collection tray in galvanised steel. • Filters: folded, thickness 48 mm (thickness 98 mm on UTNR 032 and 041), as standard on external air, with efficiency rating of G3, extractable from below. • Fan module: double inlet centrifugal electric fans directly connected at 3 speeds with protection rating IP44 (IP 20 on UTNR 041).

ACCESSORY MODULES • MBF - External module with additional water 4-row coil, complete with condensation drain pan for heating and/or cooling (for horizontal installations only). • KPAV - Plenum with side openings for vertical unit installation, designed to house the filter accessory and dampers.

ACCESSORIES SUPPLIED LOOSE • Two-range additional water heating coils, with left-hand connections. • Electric heater in carbon steel with galvanised steel fins (available in versions with single-phase and three-phase power supply). • Air outlet synthetic filters. • Air outlet metal filters. • Galvanised steel damper on external air inlet and/or outlet.

STANDARD CONTROLS For wall installation

£ Panel with speed and summer/winter switch. £ Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater.

Key: £ Supplied loose

UTNR

UTNR

UTNR

Additional module with cold/hot coil (MBF) Plenum for vertical installation (KPAV)

WATER CHILLERS HEAT PUMPS

AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS

INTERNAL

EXTERNAL

INTERNAL

WATER CHILLERS HEAT PUMPS

WATER CHILLERS HEAT PUMPS

VERTICAL installation

HORIZONTAL installation

AIR cooled AXIAL fans

133

023

032

50

52

52

50

50

… Recovery capacity

kW

5,44

8,02

10,89

14,51

18,59

† Heating capacity of additional coil ‡ Air flow rate/

MAX

041

kW

10,30

15,68

21,08

28,78

37,59

m/h / Pa

1.200 / 100

1.700 / 120

2.300 / 150

3.200 / 120

4.100 / 160

Static supply pressure.

MED

m/h / Pa

1.050 / 100

1.450 / 120

1.850 / 150

2.600 / 120

3.400 / 160

Speed

MIN

m/h / Pa

925 / 100

1.150 / 120

1.550 / 150

2.100 / 120

2.600 / 160

ˆ Sound pressure level

MAX

dB(A)

57

56

58

60

60

supply. Speed

MED

dB(A)

54

53

56

58

58

MIN

dB(A)

52

52

53

52

55

MAX

m/h / Pa

1.200 / 100

1.550 / 120

2.300 / 150

2.880 / 120

4.000 / 160

‡ Air flow rate/ Static return pressure

MED

m/h / Pa

1.050 / 100

1.300 / 120

1.650 / 150

2.430 / 120

2.850 / 160

Speed

MIN

m/h / Pa

925 / 100

1.150 / 120

1.020 / 150

2.020 / 120

1.850 / 160

ˆ Sound pressure level

MAX

dB(A)

53

55

58

62

58

return. Speed

MED

dB(A)

52

54

54

59

55

MIN

dB(A)

49

50

49

54

50

‰ Air flow rate/Stat. supply pres. additional module MBF speed MAX m³/h - Pa

1.000 / 56

1.500 / 88

2.100 / 93

2.800 / 73

3.950 / 81

Š Total cooling capacity additional module MBF speed MAX kW

7,00

11,84

16,02

21,06

28,62

‹ Heating capacity additional module MBF speed MAX kW

9,41

14,02

19,1

24,32

34,1

415/315

545/480

590/655

810/895

1.245/1.245

230-1-50

230-1-50

230-1-50

230-1-50

012

017

023

032

041

1.000/440/1.260

1.140/520/1.380

1.200/520/1.500

1.260/600/1.700

1.480/620/1.760

Maximum absorbed supply/return power Main supply

W V-ph-Hz 230-1-50

DIMENSIONS AND WEIGHTS W/H/D - Width/Height/Depth UTNR

mm

W΄/H΄/D΄ - Width/Height/Depth MBF

mm

650/440/670

750/520/670

750/520/670

850/600/670

950/620/670

W˝/H˝/D˝ - Width/Height/Depth KPAV

mm

1.000/440/440

1.140/520/520

1.200/520/520

1.260/600/600

1.480/620/620

UTNR weight (with water coil)

kg

90

90

90

150

230

Weight MBF

kg

37

45

45

54

60

Weight KPAV

kg

20

24

28

30

35

In the following conditions: … Expulsed air: 20°C D.B. - 50% R.H.; Renewal air –5°C D.B., 80% R.H. Maximum speed. † Water 70°C with Δt 10°C. Maximum speed. ‡ Unit without accessories, with standard filter. ˆ At 3 m from air outlet, with free nozzle and directionality factor of 2. ‰ Unit with standard filter and external MBF module. Š Water 7/12°C. Maximum speed. ‹ Water 45/40°C. Maximum speed.

INDUSTRIAL & PROCESS COOLING

017

%

EXP Polyvalent systems

012

Recovery efficiency

CONDENSING UNITS

UTNR MODEL

SYSTEM ACCESSORIES

EXTERNAL

FAN COIL UNITS

Plenum for vertical installation (KPAV)

TERMINAL UNITS

INTERNAL

EXTERNAL

HORIZONTAL installation with MBF module

K17000EN_2010 3.000 - Printed: gfp.it

2010

APPLIED SYSTEMS Product Catalogue RHOSS S.P.A. Via Oltre Ferrovia, 32 - 33033 Codroipo (UD) - Italy tel. +39 0432 911611 - fax +39 0432 911600 [email protected] - www.rhoss.it - www.rhoss.com

La RHOSS S.P.A. declines all responsibility for possible mistakes in this document and reserves the right to alter the features of their products without notice.

IR GROUP S.A.S.U. 7 rue du Pont à Lunettes - 69390 Vourles - France tél. +33 (0)4 72 31 86 31 - fax +33 (0)4 72 31 86 30 [email protected] RHOSS Deutschland GmbH Hölzlestraße 23, D-72336 Balingen, OT Engstlatt - Germany tel. +49 0 7433 - 260270 - fax +49 0 7433 [email protected] - www.rhoss.de RHOSS MERCOSUR Benjamin Constant 576 - 1er Piso C.P. 1214 - Asuncion Paraguay tel/fax +595 21 493 897 - www.rhossmercosur.com Commercial offices Italy: / Italy branch offices: North-East Area:: 33033 Codroipo (UD) - Via Oltre Ferrovia, 32 tel. +39 0432 911611 - fax +39 0432 911600 North-West Area: 20041 Agrate Brianza (MI) Centro Colleoni - Palazzo Taurus, 1 tel. +39 039 6898394 - fax +39 039 6898395 Central-South Area: 00199 Rome - Viale Somalia, 109 tel. +39 06 8600699 - 8600707 - fax +39 06 8600747 South Area: 81100 Caserta - Via Cesare Battisti, 51 tel. +39 0823 329580 - fax +39 0823 329580

Rhoss is involved in the Eurovent certification programme. The products in question are included in the guide to Eurovent certified products, which can be found at www.eurovent-certification.com