Menu Selection: ... MCZ33905_4 5V P3.2 32ld/54ld SOIC WB EP Qualification ... '
xx+3' indicates an additional 3 units have been added to the sample size to be ...
Test Program ID: MA3390XX_DX Menu Selection: Canvas_905BD _5v_QA Test Program Rev: DX
Plan or Results: Results Revision #: 1.0 Date: 24SEP10
Part Name: CANvas Qual Vehicle PN: MCZ33905D5EK P3.0/P3.1 Technology: SMOS8MV / C027TXXQ Package Description: (2017) 54LD SOIC WB 4.6 EP (2020) 32LD SOIC WB 4.7 EP Fab site: Assembly site: Final Test site: Rel Test site:
TEST GROUP B - ACCELERATED LIFETIME SIMULATION TESTS Stress
HTOL
JEDEC22 AEC-Q100 Reference
A108
Test Conditions
End Point Requirements
High Temperature Operating Life TEST @ RHC Drift R&R (HTOL): HTOL = 125°C for 168 hrs Required 504 hrs For Info Only Bias: Vsup3=19V, Vdut1=5V, Vdut4=5V, Vdut2=8.5V
Minimum Sample Size per lot
# of Lots
Total Units including spares
77
1
80
Lot A
Results Lot B
Lot C
168hrs: 0/80u 500hrs: 0/80u Drift R&R: PASS
Comments (Generic Data: Note 2)
Performed on MCZ33905BD5EK P3.2 For HTOL drift analysis requirements, see Notes 5 & 6.
TEST GROUP E - ELECTRICAL VERIFICATION TESTS Stress
ED
JEDEC AEC-Q100 FSL Reference
Test Conditions
AEC-Q100- Electrical Distribution (ED) 009, Freescale 48A spec
Performed on 5V configuration MCZ33905BD5EK P3.2, MCZ33905BS5EK P3.2, and MCZ33904B5EK P3.2
General Notes: 1- Optional Spare Units: 'xx+3' indicates an additional 3 units have been added to the sample size to be used ONLY in the event of lost or mechanically damaged units so as to have the required number of samples at test completion; these 'spares' shall not be used to replace failing units; ALL failures found in the total sample size shall be recorded and acted upon accordingly. 2- Generic Data: Document source of all generic data in the Generic Data Reference List below. 3- CSAM SS=11 units for each stress test for each lot when required. 5- HTOL Drift Analysis (%drift): Drift analysis will be performed on all 3 HTOL lots, 80 units per lot, and will consist of evaluating the T0 to Treadpoint parametric means of the populations at each readpoint looking for drift that exceeds 10%; [% of drift = (Average value @ Treadpoint - Average value @ T0) / (Limit Max- Limit Min)] 6- HTOL Drift Analysis (Cpk): Any parameter with a Cpk less than 2 after the final readpoint will be identified. Generic Data Reference List: References shall include (as applicable) Part Number, PPAP#, QUARTZ#, and date data generated. Generic data can not be older than 2 years and must not have ANY valid rejects. CofDC's must be available for all devices used as generic data in order to show applicability to the part being qualified. Part Number PPAP# Quartz# Date Generated Date CAB approved MCZ33905D5EK (P3.0) APDPPAP2009018 153500, 158117, 158437 20-Jul-09 to 14-Oct-09 15-Oct-2009 Results Revision History Table: Rev 0: 09-Sep-2010 Initial Qual Results Rev 1: 24-Sep-2010 Update with ED results, add approval signatures,