Since 2001, the Thomas & Betts manufacturing facility has been ISO 9001 ....
tests and reports on the status of all emergency lights and exit signs can be done
... is silenced and the LED indicator changes to a flashing mode until the problem
.
Lights the way to safety
LIFE SAFETY EQUIPMENT
Table of Contents Company Profile. . . . . . . . . . . . . . . . . . . . . . . . . Nexus® System. . . . . . . . . . . . . . . . . . . . . . . . . . MR16 LED Emergency Lighting . . . . . . . . . . . . . . Circuitry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Popular Options . . . . . . . . . . . . . . . . . . . . . . . . .
2 4 6 8 9
Exit Signs Table of contents . . . . . . . . . . . . . . . . . . . . . . . 11 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Quick Reference Chart . . . . . . . . . . . . . . . . . . . 13 Simplicity™ Premium SLED, SPLED Series. . . . . . 14 Simplicity™ Economizer SE, SES, SEN Series. . . . 16 Simplicity™ Universal UEA, UEN Series . . . . . . . . 18 Genesis™ Over Door & Floor Proximity Tandem Series.20 Genesis™ GX, GXE Series. . . . . . . . . . . . . . . . . 22 Galaxy™ XD, XDN Series . . . . . . . . . . . . . . . . . . 24 Galaxy™ Slim TX, TXE Series . . . . . . . . . . . . . . . 25 Galaxy™ XDPC Series . . . . . . . . . . . . . . . . . . . . 26 UX4 LED Steel Exit & Combination Series . . . . . . 28 Grande™ Exit Series . . . . . . . . . . . . . . . . . . . . . 30 Grande™ Combination Series. . . . . . . . . . . . . . . 32 Quick™ QLX, QLXN Series . . . . . . . . . . . . . . . . . 34 Quick™ UQLXN-2MR Combination Series. . . . . . . 35 Quick™ UQLXN-2SQ, UQLXN-OR-ID Series . . . . . 36 Cluster™ LED UQLXN500-2LED Combination Series. . . 38 Severe™ XV, XVE Series. . . . . . . . . . . . . . . . . . . 40 Severe™ XV12E, XV24E Combination Series . . . . 42 Severe™ XVHZ, XVEHZ Series. . . . . . . . . . . . . . . 44 Severe™ XVH, XVH12N & XVH12H Combination Series. 46 X402, EXP Series. . . . . . . . . . . . . . . . . . . . . . . 48 XT Tritium™ Series . . . . . . . . . . . . . . . . . . . . . . 50 Pendant Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Special Wording Panels. . . . . . . . . . . . . . . . . . . 52
Battery Units Table of contents . . . . . . . . . . . . . . . . . . . . . . . Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Reference Chart . . . . . . . . . . . . . . . . . . . Phantom™ Series . . . . . . . . . . . . . . . . . . . . . . . Mini-Phantom™ Series . . . . . . . . . . . . . . . . . . . TBR Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . RD Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . LS605P1 Series. . . . . . . . . . . . . . . . . . . . . . . . LCA-2SQ Series. . . . . . . . . . . . . . . . . . . . . . . . Cluster™ LED LCA-2LEDR & ELF652D Series. . . . LCA-2MRS & LCA-2LD Series . . . . . . . . . . . . . . LCA1250 Series. . . . . . . . . . . . . . . . . . . . . . . . Grande™ Series . . . . . . . . . . . . . . . . . . . . . . . . Camray® LED Series. . . . . . . . . . . . . . . . . . . . . MG & MN Series. . . . . . . . . . . . . . . . . . . . . . . . PG & P12G Series. . . . . . . . . . . . . . . . . . . . . . . PN & P12N Series. . . . . . . . . . . . . . . . . . . . . . . PQ & P12Q Series . . . . . . . . . . . . . . . . . . . . . . S12E & S24E Series. . . . . . . . . . . . . . . . . . . . .
55 56 59 60 62 64 66 68 69 70 72 73 74 76 78 80 82 84 86
FG & FN Series. . . . . . . . . . . . . . . . . . . . . . . . . Severe™ V Series . . . . . . . . . . . . . . . . . . . . . . . Severe™ VH Series . . . . . . . . . . . . . . . . . . . . . . EXP6N & EXP12N Series. . . . . . . . . . . . . . . . . .
88 90 92 94
Remotes & Heads Table of contents . . . . . . . . . . . . . . . . . . . . . . . 97 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Phantom™ Series . . . . . . . . . . . . . . . . . . . . . . 100 Decorative™ Series. . . . . . . . . . . . . . . . . . . . . 101 Camray® LED Series. . . . . . . . . . . . . . . . . . . . 102 SAF-T-RAY™ Series. . . . . . . . . . . . . . . . . . . . . 103 DR Series. . . . . . . . . . . . . . . . . . . . . . . . . . . 104 ELF2 Series. . . . . . . . . . . . . . . . . . . . . . . . . . 105 ELF3 Series. . . . . . . . . . . . . . . . . . . . . . . . . . 106 ELF623 Series . . . . . . . . . . . . . . . . . . . . . . . . 107 ELF645 Series . . . . . . . . . . . . . . . . . . . . . . . . 108 ELF647 Series . . . . . . . . . . . . . . . . . . . . . . . . 109 ELF640 Series . . . . . . . . . . . . . . . . . . . . . . . . 110 ELF650 Series . . . . . . . . . . . . . . . . . . . . . . . . 111 ELF647C Series. . . . . . . . . . . . . . . . . . . . . . . 112 ELF651 Series . . . . . . . . . . . . . . . . . . . . . . . . 113 EPF401 Series. . . . . . . . . . . . . . . . . . . . . . . . 114 X402 Series. . . . . . . . . . . . . . . . . . . . . . . . . . 115
Emergency Ballasts Table of contents . . . . . . . . . . . . . . . . . . . . . . Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . Ballast/Reference Chart. . . . . . . . . . . . . . . . . . LADL7 Series. . . . . . . . . . . . . . . . . . . . . . . . . LADL12 Series. . . . . . . . . . . . . . . . . . . . . . . . LADL20-N Series . . . . . . . . . . . . . . . . . . . . . . LADL28 Series. . . . . . . . . . . . . . . . . . . . . . . . LADL30-N Series . . . . . . . . . . . . . . . . . . . . . . LADL32 Series. . . . . . . . . . . . . . . . . . . . . . . . LADL540 Series. . . . . . . . . . . . . . . . . . . . . . . EPC-1-L Series. . . . . . . . . . . . . . . . . . . . . . . .
www.lightalarms.com
117 118 119 120 121 122 123 124 125 126 127
Inverter Series Table of contents . . . . . . . . . . . . . . . . . . . . . . Low Capacity Mini Inverter Series. . . . . . . . . . . Mini Inverter Series. . . . . . . . . . . . . . . . . . . . . Features & Benefits . . . . . . . . . . . . . . . . . . . . Compact Series . . . . . . . . . . . . . . . . . . . . . . . IPS Single Phase Series. . . . . . . . . . . . . . . . . . FTC Single Phase Series. . . . . . . . . . . . . . . . . 3FTC Three Phase Series . . . . . . . . . . . . . . . . FTC3R & 3FTC3R Series. . . . . . . . . . . . . . . . . Systems Options Details . . . . . . . . . . . . . . . . . Control Panel & Display Functions . . . . . . . . . . AC Central Systems Request Data . . . . . . . . . .
129 130 132 134 136 138 140 142 144 145 146 147
Lamp Information Table of contents . . . . . . . . . . . . . . . . . . . . . . 149 Lamp Reference Chart . . . . . . . . . . . . . . 150-151 Lamp Data. . . . . . . . . . . . . . . . . . . . . . . 152-153
Accessories & General Information Table of contents . . . . . . . . . . . . . . . . . . . . . . Unit Accessories. . . . . . . . . . . . . . . . . . . . . . . Mounting Plates. . . . . . . . . . . . . . . . . . . . . . . Wire Guards. . . . . . . . . . . . . . . . . . . . . . . . . . Wire Size Guide . . . . . . . . . . . . . . . . . . . . . . . National Electrical Code. . . . . . . . . . . . . . . . . . Life Safety Code. . . . . . . . . . . . . . . . . . . . . . . Limited Warranty . . . . . . . . . . . . . . . . . . . . . . Product Index. . . . . . . . . . . . . . . . . . . . . . . . .
155 156 157 158 160 161 164 168 170
1
Thinking Inside the Box Our North American Manufacturing Center of Excellence is Second to None We design and manufacture our high-performance products at a state-of-the-art North American Center of Excellence. Our dedicated expert teams work together under one roof, giving us unparalleled capabilities in design, innovation, and quality design to assembly to order completion.
We are Designers Creativity, innovation, and commitment are values shared by everyone at our center of excellence. We have an unlimited capacity for design, and take great pride in creating solution-based products that meet our customers’ needs. When an application presents a challenging issue, our expert design team can develop a product that solves the problem. Quality, safety, ease of installation, and long-term reliability are designed into each product from the beginning, ensuring excellence.
We are Engineers and Creators
We are Innovators and Builders
Combined Experience: Over 100 Years
Our highly skilled mechanical, electrical and software engineers are specialists with proven expertise in the emergency lighting industry. The entire operations team is centralized for maximum synergy from initial design to final assembly and testing.
2
The new AOI (automated optical inspection) machine added to the Thomas & Betts printed circuit board operation in 2012 is one of the first of its kind in use in North America.
As part of Thomas & Betts, a member of the ABB Group, our center of excellence benefits from frequent investment in the latest manufacturing technology. Automation is integrated throughout our manufacturing operations, optimizing efficiency to produce thousands of precision final assemblies each day.
www.lightalarms.com
North American Manufacturing Facility We are a Solution-Based, Vertically Integrated Manufacturer With over 150 people on our North American manufacturing team, we have complete control over lead time, service, and quality. Our manufacturing capabilities include plastic components, metal binding, circuit boards and final assembly, including small inverters. We can produce exactly what we need without waiting for a large production run or overseas shipment.
We are Developers and Forward Thinkers Our manufacturing capabilities are so broad, with the capacity for such high volume that we support not only our own production needs, but also manufacture parts for ABB as well. Our team is known for solving issues with solution-based products.
We are Quality Assurance
Since 2001, the Thomas & Betts manufacturing facility has been ISO 1400 & OHSAS 18001 compliant.
With everything under one roof in our center of excellence, we can ensure that our high internal quality and performance standards are met at every step in the process, from design to production to order fulfillment. All orders undergo functional testing using our specialized quality inspection facilities.
We are At Your Service Combined Experience: Over 80 Years
Our North American service team is dedicated to ensuring customer satisfaction. With the comprehensive engineering, manufacturing, and testing resources available at our center of excellence, we are committed to providing solutions.
The Thomas & Betts North American facility is an emergency lighting center of excellence thanks to the commitment, expertise, and creativity of every employee.
www.lightalarms.com
3
Are you prepared for a safety inspection? Building & Life Safety Codes oblige building owners/managers to ensure the safe evacuation of a building in the event of an emergency. In the interest of public safety, building owners/managers must meet the outlined requirements for exit signs and emergency lighting equipment, including the following:
• Conduct a discharge test every month. • Conduct functional tests annually. • Keep a log book of maintenance information. Complying with these requirements can be labor intensive and costly, especially in large buildings where testing every emergency light requires many man-hours. Disrupting the power supply during lengthy inspections can also put public safety at risk.
Manage Testing with Nexus® to Save Time and Costs Nexus® is a real-time monitoring system that manages the status of your entire emergency lighting and Exit Sign system from a central control unit. Nexus® runs diagnostics, performs required monthly and annual functional tests, generates maintenance logs and runs compliance reports. Available in wired or wireless (RF) versions, Nexus® installations often pay for themselves in less than two (2) years. In addition to operational savings, Nexus® helps increase system reliability and performance and reduces the risk of failed inspections. One building or a group of properties under the same management can be monitored with Nexus®.
Maximize System Availability By allowing maintenance personnel to easily maintain and monitor the emergency lighting system without having to manually check each unit, Nexus® reduces the hours required to disrupt the power supply for inspections. With Nexus®, monthly tests and reports on the status of all emergency lights and exit signs can be done individually, in groups, or together. Advantages of the Nexus® system include saving labor; maximizing system availability by testing units in groups and stages rather than setting all units in recovery mode; and the convenience of self-monitoring. Nexus® indicates the location of a faulty unit and reports it instantly without requiring a manual search.
Update Status Instantly Nexus® passes messages both to and from the emergency units to instruct the units to perform all mandatory testing by communicating between the emergency units and a centrally located controller. Nexus® is a proven system supported by a 5-year warranty, and can contribute to LEED certification and support green building initiatives.
4
www.lightalarms.com
For Nexus® compatibility please, refer to individual product pages for complete details Small System Example In a system of less than 100 units it is most likely that the only hardware required, other than the emergency units themselves, is a controller. All communication would occur wirelessly and installation would not vary greatly from a nonmonitored system. Once the units are in place, the system will establish the mesh network. The building itself could be quite large as each unit only needs to be able to communicate with its close neighbors and does not need to communicate directly with the controller.
Large System Example The Nexus® RF system has been designed to be extremely flexible and provides for a range of system options. Each large site will need to be assessed for the best system solution with the assistance of Thomas & Betts technical staff. The basic Nexus® RF system is designed to run on an Ethernet network which is present in most modern buildings however through a range of interface cards the backbone of the network could be WLAN. As with the small system example, site performance will be optimized through the careful selection and placement of Area Controller Routers and the Area Controller to form efficient clusters. Building layout and materials will also play some role in determining the best solution to deliver a highly effective means of testing and maintenance requirements.
www.lightalarms.com
5
High Output MR16 LED Emergency Lighting MR16 LED Illumination
MR16 LED Lamp Benefits
With the remarkable technology development in the last decade, the lightemitting diode (LED) is becoming the preferred solution in lighting applications. The emergency lighting industry is no exception: today virtually every new product introduced to market includes “white light” light LEDs for emergency illumination. Extremely efficient and long-lasting, LED lamps become the natural alternative to incandescent lamps due to three main advantages:
• Reduces total cost of ownership, uses few fixture due to superior illumination,
• Lamp efficacy: 50 - 100 lumen per watt compared to 15 - 30 lumen per watt for the best halogen lamp. Allowing for smaller batteries and units and/ or remote capacity
• Operational life: 30,000+ hours, equivalent to a lifetime warranty in emergency lighting.
•
L ower lamp temperature: (80 - 120°C) is a huge benefit for lighting in hazardous locations.
thus reducing instillations cost and future maintenance of the entire system.
•
UL-recognized components.
• Available for standard battery voltages 6V, 12V and 24V as well as 120V operation.
•
E nergy-efficient LED MR16 lamp provides equivalent lighting performance to a much higher watt halogen MR16 lamp.
•
R educes required battery capacity by 75%, for Battery Units and Remote heads.
•
Small profile, compact white lighting is ideal for architectural applications.
•
Typical 30,000 hours of Operational Life.
•
Vibration-resistant LED stands up to industrial environments.
•
Ideal for indoor and outdoor use.
200-220-Lumen 4W MR16 LED
340-Lumen 5W MR16 LED
540-590 Lumen 6W MR16 LED
Leading the technology trend, Lightalarms offers a complete series of 4W MR16 LED lamps available for all the standard battery voltages: 6V, 12V, 24V and 120V. With up to 30,000 hours of operational life and a luminous flux of typically 200 to 220 lumens, they are available with most emergency heads designed to hold an MR16 lamp and meet the majority of illumination specifications. For example: one pair of LED emergency heads installed at a height of 7.5ft illuminates a 6ft by 55ft path of egress.
Keeping pace with technology, in 2012 we introduced a 12V-5W MR16 LED lamp. With a typical luminous flux of 340 lumens, this lamp has the same lighting performance as a 20W high-output halogen MR16. A twin emergency head installed at a height of 7.5ft illuminates 70ft path of egress.
A 6W MR16 LED lamp delivers up to 590 lumens for an average spacing in emergency lighting of 106 feet with an efficacy of 98.3 Lm/w, it is over 6 times the efficacy of a MR16 35W halogen with similar light output. This lamp can deliver the highest linear foot of illumination per watt on a path of egress! (spacing in feet / watt) 8.83ft compare to 1.37ft for a MR16 35W.
®
55 ft .
70 ft
106
.
ft.
6 ft.
6 ft.
6 ft.
55-ft. Path of egress 2 X 4W MR16 LED
70-ft. Path of egress 2 X 5W MR16 LED
106-ft. Path of egress 2 X 6W MR16 LED
Based on an average of 1 foot candle
Based on an average of 1 foot candle
Based on an average of 1 foot candle
6
www.lightalarms.com
Case Study: Fewer MR16 LED units required Emergency lighting units with MR16 LED lamps provide the same illumination at floor level using significantly less units. • Reduced Installation Costs, less product needed and labor. • Reduced Energy Costs, keeping batteries charged at full capacity to be ready to respond to an emergency situation at any time.
• Reduced Maintenance and Testing Cost, less units to maintain and test in the Emergency Lighting System. • Reduced Lamp Replacement Cost, LED lamps have a 30,000+ hour lamp life compare to only a few hundred hour typical with incandescent lamps. • Reduced Environmental impact, less product materials, less batteries, less transportation, less packaging, less labor, less waste.
Compare Where the building code requires an average of 1 foot-candle and a minimum of 0.1 foot-candle at floor level along the path of egress on a 150’ x 9’ x 9’ corridor with an egress door at one end, a 150’ x 6’ path of egress, and a 7.5’ unit mounting height.
Standard wedge-base 9W Incandescent Lamp
4W MR16 LED lamps
Standard Emergency Lighting Units with 9W wedge-base incandescent lamps requires a total of 10 double-head units or remotes
Same Standard Emergency Lighting Units with 4W MR16 LED lamps requires a total of 5 double-head units or remotes MR 16 LED LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
REPLACEMENT NUMBER
LD1
6
4
199
580.0097-L
LD7
12
4
220
580.0093-L
LD13
24
4
220
580.0098-L
LD14
24
6
590
580.0100-L
LD25
120
4
204
580.0095-L
5W MR16 LED lamps
New! 6W MR16 LED lamps
Same Standard Emergency Lighting Units with 5W MR16 LED lamps requires a total of 3 double-head units or remotes
Same Standard Emergency Lighting Units with 6W MR16 LED lamps requires a total of 2 double-head units or remotes
MR 16 LED LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
MR 16 LED LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
LD9
12
5
340
REPLACEMENT NUMBER 580.0104-L
REPLACEMENT NUMBER
LD10
12
6
540
580.0106-L
LD14
24
6
590
580.0100-L
www.lightalarms.com
7
Circuitry Improved Diagnostics Circuitry
Pulse Type Circuitry
Self-Testing & Monitoring Diagnostic Circuitry
Prolongs the life of a battery through pulse charging
By incorporating diagnostics features with a high-powered 8-bit microcontroller, our Improved Diagnostics system ensures unsurpassed reliability in one, totally contained system. In the event of a unit malfunction, the Improved Diagnostics system produces an audible warning in the form of an intermittent beep and the LED indicator associated with the fault will illuminate continuously. When the problem is acknowledged by depressing the alarm/silence/test button, the alarm is silenced and the LED indicator changes to a flashing mode until the problem is corrected.
• • • • •
Continually monitors system parameters ncorporates state-of-the-art microcontroller technology D includes audio and visual service alarms DNA non-audible version for visual service alarms only Self-testing in accordance with NFPA101, Life Safety Code minimum 30 seconds every 30 days, 30 minutes every six months and 90 minutes annually.
Features Battery Failure • (Red) Illuminates if the battery is shorted or battery voltage drops below preset value. Will also detect incorrect battery (ie. 6VDC vs. 12VDC) Battery Disconnect • (Red) Illuminates if the battery circuit is open. Charger Failure • Red) Illuminates when charger is not functioning properly by monitoring the charger current. Lamp Failure
• (Red) Illuminates when one or more emergency lamps fail. Also monitors remote lamps. Service Alarm
• (Red) Illuminates when a fault is detected that requires a qualified service technician. AC-On
• Green) Lit when line voltage is present. Charger On
• Amber) Illuminates when charger is recharging the battery. Alarm Silence / Manual Test Switch
• Button is used to acknowledge and silence audible alarms. • Also functions as a manual test switch to simulate a power failure. Self Testing
• Unit tests itself every thirty days for a minimum 30 seconds, thirty minutes on the sixth month and ninety minutes annually.
TO ORDER FOR COMPATIBLE UNIT Add Suffix: -ID (for audible circuit) to model number Add Suffix: -IDNA (for non-audible circuit) to model number Improved diagnostics (ID or IDNA) includes a Time Delay function, if needed it can be enabled/disabled in the field (15 min) or it can be preset at the factory by including the suffix ID-TD* or IDNA-TD* (*5 min., or *10 min., or *15 min.)
8
Lightalarms® PulseType circuitry utilizes the latest in solid state design to provide a technically advanced charger combined with features and functions that promote long reliable battery life and excellent unit performance. The design of the PulseType circuit takes into account the long periods of inactivity typical of standby emergency equipment. Batteries are kept at full capacity by a pulse charge that allows the battery to cycle continuously. This greatly reduces the problem of grid corrosion and dramatically increases battery performance. Lightalarms® computer-tests all active components on the circuit boards during assembly. Critical functions such as brownout, low voltage disconnect, and charge voltage are individually monitored and adjusted at the factory.
Features 120/277V Input • Capability to operate with 120Vor 277V input. Fused Output Circuit for Units with Remote Capacity • Emergency units up to 54W have a single fused output circuit. Units over 54W have two fused output circuits supplied standard. Dual Diagnostic Indicator Lights • Dual indicators, red and amber continuously monitor the condition of the battery, charge circuit and presence of AC. Temperature Compensation • At high ambient temperatures, batteries need less charge voltage to recharge.
• At cold temperatures, batteries require a higher charge to maintain full capacity.
• The PulseType charger automatically adjusts the charge voltage to precisely what the batteries require at a given temperature. Sealed Relay • Sealed relay protects against environmental contaminants. Low Voltage Battery Disconnect • The lighting load is disconnected from the battery at 87.5% of nominal battery voltage. This prevents deep discharge damage to the battery. Brownout Protection • Emergency lamps energized when AC voltage falls to approx. 80% of nominal voltage, the level at which most fluorescent and HID fixtures extinguish. Battery Lockout • This labor saving feature prevents the battery from discharging when the unit is installed to a non-energized circuit. The battery is electronically locked out until the unit is energized with AC power. Contractors do not have to return to a job site to connect batteries when the building’s main power is turned on. They can install the unit and connect the battery in one convenient operation. Reverse Polarity Protection • A polarized plug is used to connect the battery to the circuit board, thus preventing damage from occurring to the system. Current Limited Output • Extends battery life by preventing overheating and battery gassing during recharge.
www.lightalarms.com
Popular Options Lightalarms® Emergency Lighting Units and Exit Signs are available with a range of options that can be added to enhance performance, simplify testing or adapt emergency battery units or exit signs for use in specific environments. Please refer to individual product pages to verify availability of individual options on specific equipment.
Voltmeter
Fire Alarm Activated Flasher
Option provides a visual indication, in the test mode, of the unit’s battery voltage. The good/check meter face allows maintenance personnel to recognize charger and battery function.
Fire Alarm Activated Flasher option is for an Exit Sign that is wired into the Fire Alarm system of a building via 24 volt wire. When the fire alarm is activated the exit legend will flash to draw additional attention to the exit discharge area. This flashing option will only activate when the fire system is activated.
Add Suffix: -V
Add Suffix: -FAF
Ammeter Option provides an indication of charge current when the unit is in the equalize mode.This verifies charger capability and the current acceptance of the battery. Add Suffix: -A
Dual Circuit (Exit Signs) Option provides two AC input circuits to permit 2 separate AC sources to energize the sign.
Fire Alarm activated Flasher/Buzzer Fire Alarm activated Flasher/Buzzer option is for an Exit Sign that is wired into the Fire Alarm system of a building via 24 volt wire. When the fire alarm is activated, the exit legend will flash and the Exit Sign will buzz to draw additional attention to the exit discharge area. This option will only activate when the fire system is activated. Add Suffix: -FBF
Add Suffix: -2
Time Delay
Tamper Proof/Vandal Resistant Screws
Option is designed to be used in areas where HID type lamps are used for normal lighting. As these lamps require several minutes to re-strike and to produce their nominal lighting output, it is necessary to also hold the emergency lighting on for this period, even after the AC utility has been restored. A time delay unit can be helpful in areas where it is difficult to directly access an emergency lighting unit’s test switch. The power to the unit can be briefly switched off and on at the breaker panel, and the maintenance person can then return to the unit and observe a timed emergency operation.
Tamper proof screws may be used on certain units to avoid unauthorized entry to circuitry or vandalism. Add Suffix: -VR
Lamp Disconnect Switch Option will disconnect lamp load when area is not in use during prolonged power failure. The switch may also be used to reactivate emergency power to remote or unit heads.
Add Suffix: -T1 (5 minutes), -T2 (10 minutes), -T3 (15 minutes)
Add Suffix: -DS
Damp Location
Photocell Test Switch
Option for environments that are subject to moderate amounts of moisture (humidity), and a temperature range between 10°C (50°F) and 40°C (104°F). Example: partially protected exterior areas such as canopies, stairwells, etc.
Allows for testing of an emergency battery unit, a Self-Powered battery back-up exit sign or combination unit by means of illuminating, with a flashlight, a photocell mounted in the bottom of the fixture.
Add Suffix: -DL
For product compatibility please contact the factory.
Improved Diagnostic Circuitry (for exit signs)
Add Suffix: -P or -PST depending on series
Option is designed to continuously monitor the charger assembly, battery and LED assembly current. If a fault is indicated, the external service required indicator will illuminate. The diagnostic/self test will self test for minimum 30 seconds every 30 days, 30 minutes every six months and 90 minutes annually. Meets NFPA 101 Life Safety Code requirements for periodic testing.
Flasher The flasher option is used within Exit Signs to draw additional attention to the exit discharge area. When there is an emergency situation, the exit legend will illuminate as well as begin to flash thus drawing additional attention to the Exit Sign leading to a exit discharge. Add Suffix: -FL
Flasher/Buzzer The flasher/buzzer option is used within Exit Signs to draw additional attention to the exit discharge area. When there is an emergency situation, the exit legend will illuminate as well as begin to flash and admit an audible buzzer thus drawing additional attention to the Exit Sign leading to a exit discharge.
Improved Diagnostic (Audible) Add Suffix: -ID Improved Diagnostic (Non-Audible) Add Suffix: -IDNA
Improved Diagnostic Circuitry (for battery units) Improved Diagnostic (Audible) Add Suffix: -ID Improved Diagnostic (Non-Audible) Add Suffix: -IDNA For complete details refer to page 8.
Add Suffix: -FB
www.lightalarms.com
9
Exit Signs Series
INTRODUCTION About Exit Sign & Quick Reference Chart
ARCHITECTURAL Simplicity™ Premium™ SLED, SPLED Series
COMMERCIAL Simplicity™ Economizer™ SE, SES, SEN Series
COMMERCIAL Simplicity™ Universal™ UEA, UEN Series
ARCHITECTURAL Genesis™ “over the door” and “floor proximity” Tandem Series
12-13
14-15
16-17
18-19
20-21 WITH LED LAMP HEADS
ARCHITECTURAL Genesis™ GX, GXE Series
COMMERCIAL Galaxy™ XD, XDN Series
COMMERCIAL Galaxy™ Slim TX, TXE Series
COMMERCIAL Galaxy™ XDPC Series
COMMERCIAL UX4 LED Steel Exit & Combination Series
22-23
24
25
26-27
28-29
WITH LED LAMP HEADS
WITH LED LAMP HEADS
ARCHITECTURAL Grande™ Exit Series
ARCHITECTURAL Grande™ Combination Series
COMMERCIAL Quick™ QLX, QLXN Series
COMMERCIAL Quick™ UQLXN-2MR Combination Series
COMMERCIAL Quick™ UQLXN-2SQ & Quick™ UQLXN-0R-ID Combination Series
30-31
32-33
34
35
36-37
WITH LED LAMP HEADS
WITH LED LAMP HEADS
COMMERCIAL Cluster™ LED UQLXN5002LED Combo & ELF652D Series
INDUSTRIAL NEMA 4X Severe™ XV, XVE Series
INDUSTRIAL NEMA 4X Severe™ XV12E, XV24E Combination Series
INDUSTRIAL Class I, Division 2 Severe™ XVHZ, XVEHZ Series
INDUSTRIAL Class I, Division 2 Severe™ XVH, XVH12N & XVH12H Combination Series
38-39
40-41
42-43
44-45
46-47
INDUSTRIAL Class I Division 1&2 Class II Division 1&2 X402, EXP Exit and Combination Series
SELF-LUMINOUS XT Tritium™ Series
PENDANT MOUNT Pendant Kits
CUSTOM SIGNAGE Special Wording Panels
48-49
50
51
52-53
www.lightalarms.com
11
About Exit Signs Unlike Battery Units, Exit Signs must be illuminated at all times, 24 hours, 7 days a week, during normal operation. During an emergency operation situation, such as a loss of AC power, the Exit Sign must be illuminated for a minimum of 90 minutes.
Legend An Exit Sign legend is defined as a single word “EXIT” with chevron indicators to direct occupants of a building to the nearest exiting point of that building. Legends are required to meet visibility, brightness, uniformity, and lettering/background contrast maximum to minimum ratios. Legend standards require EXIT lettering dimensions to be a minimum of 6 inches high with a ¾ inch stroke, and chevron indicators that are visible at 50 feet. Exit legends are available in red or green as required by local code requirements.
Illumination The most popular light source to illuminate an Exit Sign is Light Emitting Diodes (LED) which all our Exit Signs offer. We use red or green long-life, energy-efficient LEDs. LEDs are very energy efficient, limiting the energy each Exit Sign uses 24 hours a days, 7 days a week. The long life limits the maintenance required to replace lamps. There are two different methods typically used to illuminate an EXIT legend. The most common method is found in back-lit signs, which use an LED light source located behind the legend, illuminating through a red or green diffuser. The edgelit method uses a clear, white or mirrored acrylic face panel on which the legend is etched or silk-screened, and the LED light source is installed in the Exit Sign housing along the top edge of the panel, allowing the light to travel through the acrylic to illuminate the etched or a silk-screened legend. In general, back-lit Exit Signs are more economical and acrylic edge-lit Exit Signs are more high-end, elegant fixtures.
Operational Types There are typically 3 types of Exit Sign designs, AC-Only, AC/DC and Self-Powered that ensure that an Exit Sign will work under normal operation conditions and in emergency operation mode. An AC-Only Exit Sign is illuminated under normal operation conditions by the AC utility power supplied to a building; emergency operation mode power is supplied by an AC inverter or generator. An AC/DC Exit Sign is illuminated under normal operation by the AC utility power supplied to a building; emergency operation power is supplied by a DC power source, such as a battery unit with extra battery capacity to ensure that both the Exit Sign and the battery unit will run for 90 minutes. A Self-Powered or Battery Back-up Exit Sign is illuminated under normal operation by the AC utility power supplied to a building; emergency operation power is supplied by a battery contained inside the Exit Sign housing, providing illumination for a minimum of 90 minutes. A Combination Unit is also self-contained and commonly includes an Exit Sign and a two-headed battery unit combined into one unit. The Exit Sign is illuminated under normal operation, while the two heads only illuminate during emergency operation mode.
12
Environments Exit Signs are required in every type of environment. Lightalarms® manufactures Exit Signs to meet the requirements of most environments and applications. An exit housing for a standard type environment has a NEMA 1-rated housing that provides protection against incidental contact with the enclosed equipment, battery/electronics or wiring. These housings are what you would expect to see in an office type application. For vandal-resistant applications, standard Exit Signs can be made vandal resistant by using polycarbonate shields and/or tamper resistant screws, or a vandal-resistant Exit Sign such as the SevereTM Family Exit Series can be used. A Damp location is an area that is indirectly subjected to moisture and typically uncontrolled temperatures, for example in a courtyard under an eave. NEMA 4X-rated Exit Signs are designed for harsh or corrosive environments where oil-, water-, and dust-tight construction is required. There are different NEMA ratings based on the application environment. Hazardous Location-rated equipment must be a type which will NOT itself contribute to the ignition of flammable or explosive substances present in the location of the emergency lighting unit. Hazardous Locations include oil refineries, paint shops, dry cleaning plants, textile mills etc. Hazardous Location-rated equipment is divided into different Classes and Groups, depending on the specific gases or chemicals present.
Options Besides offering many different types of Exit Sign housings for various environments Lightalarms® also provides a wide choice of options to meet specific customer requirements. Self-Diagnostic/Self-Test features are designed to continuously monitor every critical function of the Exit Sign, battery, charger, LED lamps and lamp heads supplied with a Combination Unit to ensure that the unit is working properly and is ready for an emergency situation. The flasher option allows the exit panel to flash to indicate that there is an emergency situation, thus drawing attention to the exit. The flasher/buzzer option allows the exit panel to flash and sound a buzzer to indicate that there is an emergency situation, thus drawing attention to the exit. A Fire Alarm activated flasher/buzzer is connected to a fire alarm system via a 24V wire and will cause the Exit Sign panel to flash and sound a buzzer when a fire alarm is activated. The Dual Circuit feature allows input from a utility AC source as well as a secondary utility AC source. The Time Delay feature allows a Combination Unit to stay illuminated after the AC power is restored thus allowing HID lamps that may need re-striking to reach full illumination before returning to normal operation. Damp location operation is for Exit Signs that will be subjected to slight moisture and typically uncontrolled temperatures. The Cold Weather option allows the batteries inside of an Exit Sign to maintain an optimal temperature range to work properly to provide emergency back-up operation. Vandal-resistant screws and polycarbonate shields provide extra protection in areas where the Exit Sign may be subject to vandalism.
www.lightalarms.com
X
X
X X
X
X
X
X
X
XT SERIES (PAGE 50)
X
X X
EXP SERIES (PAGES 48-49)
X
SEVERE™ XVHZ COMBINATION SERIES (PAGES 46-47)
X
SEVERE™ XVHZ SERIES (PAGES 44-45)
X
SEVERE™ XV COMBINATION SERIES (PAGES 42-43)
X
SEVERE™ XV SERIES (PAGES 40-41)
X
QUICK™ 2SQ COMBINATION SERIES (PAGES 36-37)
X
QUICK™ 2MRS COMBINATION SERIES (PAGE 35)
X
QUICK™ QLX, QLXN SERIES (PAGE 34)
X
GRANDE™ COMBINATION SERIES (PAGES 32-33)
UX4 LED SERIES (PAGES 28-29)
X
GRANDE™ SERIES (PAGES 30-31)
GALAXY™ XDPC SERIES (PAGES 26-27)
X
GALAXY™ SLIM SERIES (PAGE 25)
GENESIS™ GX, GXE SERIES (PAGES 22-23)
X
GALAXY™ XD, XDN SERIES (PAGE 24)
GENESIS™ FLOOR PROXIMITY SERIES (PAGES 20-21)
SIMPLICITY™ UNIVERSAL SERIES (PAGES 18-19)
SIMPLICITY™ ECONOMIZER SERIES (PAGES 16-17)
SIMPLICITY™ PREMIUM SERIES (PAGE 14-15)
Quick Reference Chart
APPLICATION Architectural Commercial Industrial Remote Capacity Damp Listed NEMA 4X Hazardous Locations
X X
X X
X
X
X
X
X
X X
X
X X
X X X X
HOUSING Aluminum Thermoplastic Steel Polyvinyl Chloride
X
X
X
X
X
X
X
X X
X
X
X
X
X
X X
X
X
X
X
X
EXIT LEGEND 6 inch Letters 8 inch Letters
X X
X X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X X X
X
X X X
X X X
X X X
X X X
X X X
X X X
X X X
X X X
X
X
X
X X X X
X X X X
X
X
X
X X
X X
X X
X X
X X
X
COLOR White Black Aluminium body or face Gray Custom
X
X
X X
X
ILLUMINATION Red LED Green LED Self-Luminious Tritium
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
AVAILABLE OPTIONS Self-Diagnostic Flasher/Buzzer Fire Alarm Active Flasher Dual Circuit Time Delay Cold Weather Vandal Resistant Screws Vandal Resistant Screws & Face Plate SPECIAL WORDING
X X X X
X
X X X X
X X X X
X X X
X X X
X X X X
X X X X
X
X X X
X X X
X X X X X X
X
X
X
X X X
X
X X X
X X X X X
X
X X X X
X X X
X
X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X X X
ACCESSORIES Pendant Mount Wire Guard - (Wall) Wire Guard - (Ceiling) Wire Guard - (End) Vandal Resistant Shield - (Wall) Vandal Resistant 4X Shield - (Wall)
X
X
X X X X
X X X X X
X X X X
X
X
X
X
X
X
X
X
ORIGIN North America
X
X
X
X
X
X
X
NOTE: This is a quick reference guide only. Refer to individual product pages for complete details regarding applicable models.
www.lightalarms.com
13
SIMPLICITY PREMIUM SLED & SPLED SERIES TM
Premium Die-Cast Aluminum and Laser-Etched Acrylic Edge-Lit Exit Sign
FEATURES
SPECIFICATIONS
Construction • Housing, trim plate, trim ring and canopy made of die-cast aluminum • U-shaped clear acrylic Legend panel features laser-etched letters and chevrons • Choice of 6 inch or 8 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Simplicity™ Premium SLED, SPLED Series. The Exit Sign specified with (D) dome or (P) pyramid trim plate, single face shall be standard with (1) legend panel, (1) housing, (1) trim ring, (1) trim plate, (1) canopy and 27 inch adjustable bar hangers and specified as double face shall be standard with (1) legend panel (with EXIT etched on each side), (1) housing, (1) trim ring, (1) trim plate, (1) canopy and 27 inch adjustable bar hangers. The Exit Sign specified with (Z) flat trim plate, recessed ceiling mount only, single face shall be standard with (1) legend panel, (1) backbox, (1) flat trim plate, and 27 inch adjustable bar and specified as double face shall be standard with (1) legend panel (with EXIT etched on each side), (1) backbox, (1) flat trim plate and 27 inch adjustable bar hangers. (D) dome or (P) pyramid trim plate models housing, trim ring, trim plate and canopy shall be made of die-cast aluminum. (Z) flat trim plate models backbox shall be made of 20 gauge steel and flat trim of die cast aluminum. Housing, trim ring, trim plate and canopy shall be in color, (W) white, (B) black or (A) brushed aluminum. Legend panel colors shall be, (RC) red on clear, (RW) red on white, (RM) red on mirror, (GC) green on clear (GW) green on white or (GM) green on mirror. The unit shall have the trim plate snap and lock in the housing with torsion spring retainers, thereby eliminating any visible screws or hardware. The legend panel shall be clear acrylic, U-shape and the letters and chevrons engraved by laser as specified. The (D) dome or (P) pyramid trim plate model Exit Sign shall be suitable for surface mount, wall, end or ceiling as well as recessed mount wall or ceiling applications. The (Z) flat trim plate recessed mount single face or double face shall be suitable for recessed ceiling installations only. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing on a PCB strip. A color matching LED sensitive EXIT legend silkscreened in (R) red or (G) green, then outlined laser etched, provides the 6” or 8” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120/277VAC, 60Hz, with a power consumption of less then 1.4W. AC/DC models shall be 120/277VAC, 60Hz, with a power consumption of less then 1.4W and allows for DC operation from 6VDC to 24VDC, drawing less then 1.4W. Self-Powered models shall be 120/277VAC, 60Hz, with a power consumption of less then 2.3W and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. When specified, the Self-Powered Exit Sign with Improved Diagnostics shall include a self-test and silent diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected the pilot light shall change color from green to red and flash with a specific code. The red light is steady-on in case of a battery disconnect; it will flash with one blink for battery failure; two blinks for charger failure and four blinks for LED lamp failure. A label with the diagnostic legend shall be visible next to the pilot light. The Exit Sign shall be tested by the Underwriters Laboratories and listed to UL 924 standards. Meets NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model __________________________.
Mounting • Modular design allows for Surface or Recessed Mount • Single face model includes (1) legend panel, (1) housing, (1) trim ring, (1) trim plate, (1) canopy and 27 inch adjustable bar hangers • Double face model includes (1) legend panel (with EXIT etched on each side), (1) housing, (1) trim ring, (1) trim plate, (1) canopy and 27 inch adjustable bar hangers and (1) canopy • Canopy included for surface wall, end or ceiling mount applications • Trim ring included for recessed wall or ceiling mount applications. • Housing provided with conduit knock-out 1/2”, top, back and end. • (D) dome or (P) pyramid trim plate used for surface or recessed wall or ceiling mount applications • (Z) flat trim plate used for recessed ceiling mount only applications Finishes • Choice of finishes: white, black or brushed aluminum, custom colors available. • Choice of Legend panel colors: red on clear (single face only), red on white, red on mirror, green on clear (single face only), green on white or green on mirror Chevrons • Laser-etched as specified • UA option includes, (4) field installed stick-on translucent chevrons, (2) for single face, (4) for double face LEDS • Red or Green Long-Life Light Emitting Diodes (LED) illumination • Optional White LEDs for custom special wording panels available Self-Diagnostics • Self-Powered models available with or without Improved Diagnostics • NEXUS® Wired system compatible Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five Year full warranty (subject to proper installation and maintenance)
CHEVRON DESIGNATION
Chevron Left (L) Single Face
Chevron Right (R) Single Face
Single Face, Double Chevron (1D) Double Face, Double Chevron (2D)
ACCESSORIES
(Order as a separate item)
Double Face, Single Chevron (RL) Represents each side of a double face panel.
Pendant, White Pendant, Black Pendant, Gray
*Wording and chevrons not to scale. For illustration purposes only.
*Specify pendant length (12”, 24”, 36”, etc).
Flat Trim
14
Dome Trim Plate
Pyramid Trim Plate
www.lightalarms.com
PW-* PB-* PA-*
TYPE
The Simplicity™ Premium Series combines a clean, modular design with state-of-the art technology, ease of installation for surface or recessed mount applications and options to meet the most prestigious interiors
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. Mounting applications available with Dome (D) and Pyramid (P) trim plates 16” [40.8 cm]
13” [32.9 cm]
Recessed Wall Mount
Recessed Ceiling Mount ONLY
3-7/8” [9.85 cm] 3-7/8” [9.85 cm]
Housing
Housing Trim Ring TrimTrim RingPlate
7-1/2” [19.05 cm] 7-1/2” [19.05 cm]
7-5/8” [19.37 cm] 7-5/8” [19.37 cm]
Surface Ceiling Mount
For Recessed Mount, For Surface Mount, use these Canopy use these components components Canopy
3-1/4” [7.62 cm] 3-1/4” [7.62 cm]
15” [38.1 cm] 15” [38.1 cm]
12-1/8” [30.9 cm]
Recessed Ceiling Mount
Surface End Mount
Mounting application available with Flat (Z) trim plate
8-5/8” [21.9 cm]
7-1/2” [19 cm]
12-3/8” [31.5 cm]
2-1/2” [6.4 cm]
6-1/4” [15.7 cm]
4” [10 cm]
Surface Wall Mount
10-5/8” [27.1 cm]
1-1/8” [2.9 cm]
4-5/8” [11.6 cm]
4” [10 cm]
2-7/8” [7.4 cm]
2-1/2” [6.4 cm]
4-5/8” [11.6 cm]
12-1/4” [31.3 cm]
3-1/4” [8.3 cm]
16-3/4” [42.7 cm]
2-7/8” [7.4 cm]
Trim Plate Panel Panel
12-15/16” [32.86 cm] 12-15/16” [32.86 cm]
3-15/16” [10.01 cm] 3-15/16” [10.01 cm]
POWER CONSUMPTION CHART MODEL
AC SPECS
DC SPECS
AC-Only
120-277VAC, 60Hz
Less than 1.4W
–
–
AC/DC
120-277VAC, 60Hz
Less than 1.4W
6 to 24VDC
Less than 1.4W
Self-Powered
120/277VAC, 60Hz
Less than 2.3W
Nickel-Cadmium battery
Min. 90 minutes
Self-Powered diagnostic
120/277VAC, 60Hz
Less than 2.3W
Nickel-Cadmium battery
Min. 90 minutes
ORDERING FORMAT LEGEND
SERIES
Blank= 6” EXIT legend 8= 8 ” EXIT legend
SLEDN= AC-Only SPLEDN= SelfPowered
HOUSING COLOR A= Brushed Aluminum W= White B= Black DB= D ark Bronze (painted) PB= Polished Brass CH= P olished Chrome
LEGEND COLOR
PANEL BACKGROUND COLOR
R= Red G= Green
C= Clear (single face only) W= White (single or double face) M= Mirror (single or double face)
TRIM PLATE
CHEVRON
OPTIONS
D= Dome P= Pyramid Z= Flat Trim
Blank= No Chevron (single face sign) 2= N o Chevron (double face sign) L= L eft Chevron (on a single face sign) R= Right Chevron (on a single face sign) RL= L eft & Right Chevron (double face sign, one chevron on each side) 1D= Double Chevron (on single face) 2D= Double Chevron (double face sign, two chevrons on each side) UA= (2 Qty) for single & (4 Qty) for doubles Universal field stick on chevrons per face
Blank= No option -X= Less back box shipped separate -LP= Panel shipped separately -FAF= Fire Alarm Flasher (SP Only) -FB= Flasher & Buzzer (SP Only) -ID= Self-test and diagnostic (SP Only) -Y= Two circuits (AC Only) -DC= AC/DC model 6 to 24VDC NEX= NEXUS® Wired1 NEXRF= NEXUS® Wireless1
1 Consult your sales representative F or Special Wording, please contact your sales representative
EXAMPLE: SPLEDNARWDL
www.lightalarms.com
15
SIMPLICITY ECONOMIZER SE, SES & SEN SERIES TM
Surface or Recessed Mount Edge-Lit Exit Sign
FEATURES
SPECIFICATIONS
Construction • Surface mount model housing made of extruded aluminum, canopy made of die-cast aluminum • Recessed mount model housing made of 20 gauge steel, includes formed steel flat trim plate and bar hangers • Legend panel features a curved contour for maximum illumination and clarity • 6 inch EXIT lettering legend available in Red or Green • 8 inch EXIT lettering legend in Red only
Supply and Install Lightalarms® Simplicity™ Economizer SE, SES, SEN Series. The Exit Sign specified as surface mount single face shall be standard with (1) legend panel, (1) housing and (1) canopy and specified as double face shall be standard with (1) legend panel (with EXIT printed on each side) (1) housing and (1) canopy. The Exit Sign specified as recessed mount single face shall be standard with (1) legend panel, (1) backbox and bar hangers and specified as double face shall be standard with (1) legend panel (with EXIT printed on each side) backbox and bar hangers. Surface mount models housing shall be made of extruded aluminum, canopy made of die-cast aluminum. Housing and canopy shall be matching in color, (OW) off white or (TA) textured aluminum. Recessed ceiling mount only models housing shall be made of 20 gauge steel, includes formed steel flat trim plate and bar hangers. Trim plate shall be in color, (OW) off white or (TA) textured aluminum. Legend panel colors shall be (RC) red on clear, (RW) red on white, (RM) red on mirror, (GC) green on clear or (GM) green on mirror. Click-to-open housing door allows easy access to legend panel and electrical wiring. The legend panel shall come standard with (4) field installed stick-on translucent directional chevron indicators. The surface mount single face Exit Sign shall be suitable for surface wall, end or ceiling installations. The surface mount double face Exit Sign shall be suitable for surface end or ceiling installations. The recessed mount single face or double face Exit Sign shall be suitable for recessed ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing on a PCB strip. A color matching LED sensitive EXIT legend silkscreened in (R) red or (G) green, provides the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120/277VAC, 50/60Hz, with power consumption of less than 2W. AC/DC models shall be 120/277VAC, 50/60Hz, with power consumption of less than 2W and allows for DC operation from 6VDC to 24VDC, drawing less then 1.5W. Self-Powered models shall be 120/277VAC, 50/60Hz, with power consumption of less than 3W and be supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. The Exit Sign shall be tested by Underwriters Laboratories and listed to UL 924 standards. Meets NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a three-year full warranty. The Exit Sign shall be Lightalarms® Model _______________________.
Mounting Surface Mount Models • Single face model includes (1) legend panel, (1) housing and (1) canopy • Double face model includes (1) legend panel (with EXIT printed on each side), (1) housing and (1) canopy • Canopy included for wall, end or ceiling mount applications Recessed Ceiling Mount Only Models • Single face model includes (1) legend panel, (1) backbox and bar hangers • Double face model includes (1) legend panel (with EXIT printed on each side), (1) backbox and bar hangers Finishes • Choice of housing and trim plate finishes, off white or textured aluminum • Choice of Legend panel colors, red on clear, red on white, red on mirror, green on clear or green on mirror Chevrons • Field installed stick-on translucent chevrons, (2) for single face, (4) for double face LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Not Available Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Three Year full warranty (subject to proper installation and maintenance)
16
www.lightalarms.com
RECESSED MOUNT MODELS TYPE
The Simplicity™ Economizer Edge-Lit Exit Sign combines value and elegance complementing any interior design
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. Surface Mount 12” [ 30.48cm]
4-1/4” [10.79cm] 1-5/8” [4.12cm]
12-1/2” [31.75 cm]
10-5/8” [26.98 cm]
11-1/8” [28.25 cm]
10-1/8” [25.4 cm]
11 -1/4” [25.71 cm]
12” [ 30.48cm]
16” [40.6 cm]
Wall Mount
Ceiling Mount
End Mount Recessed Ceiling Mount only (F) flat trim plate 4-1/4” [10.8 cm]
16” [40.6 cm]
3-3/8” [8.5 cm]
3-3/8” [8.6 cm]
7-1/8” [18.1 cm]
7” [17.7 cm]
15-1/8” [38.3 cm]
11-3/4” [29.7 cm]
POWER CONSUMPTION CHART MODEL
AC SPECS
DC SPECS
AC-Only
120/277VAC, 50/60Hz
Less than 2W
–
–
AC/DC
120/277VAC, 50/60Hz
Less than 2W
6 to 24VDC
Less than 1.5W
Self-Powered
120/277VAC, 50/60Hz
Less than 3W
Nickel-Cadmium battery
Minimum of 90 minutes
ORDERING FORMAT 6 INCH SERIES SE= AC-Only SES= AC/DC SEN= Self-Powered
TRIM Blank= Surface Mount Only F= Recessed Mount Only (flat trim)
HOUSING COLOR TA= Textured Aluminum OW= Off White
LEGEND COLOR RC= Red on clear RW= Red on white RM= Red on mirror GC= Green on clear1 GM= Green on mirror 1
FACE 1= Single face 2= Double face
*Green on white not available. 1 Single face only.
8 INCH SERIES 8SE= AC-Only 8SES= AC/DC 8SEN= Self-Powered
TRIM Blank= Surface Mount
HOUSING COLOR TA= Textured Aluminum OW= Off White
LEGEND COLOR RC= Red on clear1 RW= Red on white RM= Red on mirror 1
FACE 1= Single face 2= Double face
Single face only.
EXAMPLE: SEFOWRC1
www.lightalarms.com
17
SIMPLICITY
TM
EDGE-LIT SERIES
Single and Double face, Surface and Recessed* Mount Edge-Lit Exit Sign
FEATURES
SPECIFICATIONS
Construction • Extruded Aluminum Housing • Impact resistant Thermoplastic plastic end caps and canopy • High grade acrylic panel • 6 inch EXIT lettering legend, available in Red or Green • Damp location Listed
Supply and Install Lightalarms® Simplicity™ Universal Edge-Lit Series. The Exit Sign specified as universal mount shall be standard with (1) legend panel, design for both single face or double face applications with (1) additional mirror panel (4) peel-off translucent directional chevrons; (1) housing, (1) canopy (1) Trim plate (2) 27 inch T-Bar Hangers* and (1) junction box. Universal mount model housing shall be fabricated of extruded aluminum; canopy and end caps shall be impact resistant Thermoplastic. Housing shall be in color satin aluminum with canopy and end caps in black. Legend panel colors shall be, (RM) red on mirror, (GM) green on mirror as specified. Acrylic panel shall be in double face EXIT legend configuration printed in red or green, as specified, on a mirror background. If a single face is required, an addition at mirror panel is supplied to be field installed covering the additional EXIT face legend. The acrylic panel shall pivot and ratchet lock into positions from 0° to 180° to allow for wall, flat or sloped ceiling applications. (4) Factory installed translucent chevrons, allowing for easy peel-off removal to be configured in the field as required by Code. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing on a PCB strip. A color matching LED sensitive EXIT legend silkscreened in (R) red or (G) green, provides the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120/277VAC, 60Hz, with a power consumption of less then 4W. Self-Powered models shall be 120/277VAC, 60Hz, with a power consumption of less than 4W and supplied with a sealed maintenance-free nickel cadmium battery, providing a minimum of 90 minutes illumination upon AC failure. The Exit Sign shall be tested by the Underwriting Laboratories and listed to UL 924 standards. Meeting NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a three-year full warranty. The Exit Sign shall be Lightalarms® Model: .
Mounting Universal Mount Model • Double face acrylic panel with mirror background, field adaptable for single face • Pivoting panel design allows for recessed, surface, wall or ceiling mount installation • A ratcheting mechanism allows the panel to be set in place from 0° to 180° for wall or sloped ceiling mounting • Canopy included for surface wall, end or ceiling mount application • Trim plate, 27 inch adjustable T-Bar hangers and a junction box included for recessed* application Finishes • Satin Aluminum housing • Black end caps and matching canopy • Choice of Legend panel color, red on mirror or green on mirror Chevrons • (4) Factory installed translucent chevrons, allowing for easy peel-off removal as required LEDs
• Red or Green long life Light Emitting Diodes (LED) Illumination Self-Diagnostics
• Not available Special Wording Panels
• Not available Approvals
• Listed to UL 924 Standards • UL Listed for Damp location (32°F to 104°F, 0°C to 40°C) • Meets, NFPA101, (Life Safety Code) NFPA 70-NEC and OSHA illumination Standards Warranty
• Three Year full warranty (subject to proper installation and maintenance) * Not intended for closed ceilings such as plaster and sheetrock.
18
www.lightalarms.com
!
NEW
UNIVERSAL PANEL
TYPE
The Simplicity™ Edge-Lit Exit Sign offers an edge-lit exit that comes complete “all in one box” with a double face exit panel, field adaptable to single face and all the mounting hardware for surface and recess mount applications
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. Recessed Ceiling Mount
Recessed Wall Mount (side view)
Recessed Ceiling Mount (side view) 4-3/8” [10.99 cm]
3-1/2” [8.17 cm] 14-1/2” [35.56 cm] 4-3/8” [10.16 cm]
11-1/2” [27.94 cm]
4” [10.18 cm]
0-3/4” [1.90 cm]
2-7/8” [7.18 cm]
Surface Wall Mount 3-1/2” [8.88 cm] 3-1/2"
Surface End Mount 3-1/2"
1-5/8” [2.54 cm] 1-5/8"
3-1/2" 13" 1-5/8"
13” [8.88 13" cm]
10-3/8” [26.16 cm]
9-1/8” [23.08 cm]
Surface Sloped Ceiling Mount
13"
1-5/8" 3-1/2” [7.88 cm]
8-3/4” [20.32 cm] 8-11/16"
8-11/16"
9-5/8"
8-11/16"
9-5/8” [22.86 9-5/8" cm]
9-5/8"
7-1/8” [17.78 cm]
POWER CONSUMPTION CHART MODEL Red
AC-Only Self-Powered
Green
AC-Only Self-Powered
AC SPECS
DC SPECS
120VAC, 60Hz 277VAC, 60Hz 120VAC, 60Hz 277VAC, 60Hz
2.0-2.6W 2.6-3.1W 2.0-2.6W 2.6-3.1W
– – Nickel-Cadmium battery Nickel-Cadmium battery
– – Minimum 90 Minutes Minimum 90 Minutes
120VAC, 60Hz 277VAC, 60Hz 120VAC, 60Hz 277VAC, 60Hz
2.8-3.3W 3.5-4W 2.8-3.3W 3.5-4W
– – Nickel-Cadmium battery Nickel-Cadmium battery
– – Minimum 90 Minutes Minimum 90 Minutes
ORDERING FORMAT LEGEND 6= 6” EXIT single and double face with universal chevrons and mounting for surface or recessed
SERIES UEA= AC Only UEN= Self-Powered
LEGEND COLOR RM= Red on Mirror GM= Green on Mirror
EXAMPLE: 6UEARM
www.lightalarms.com
19
GENESIS “OVER THE DOOR” & “FLOOR PROXIMITY” TANDEM SERIES TM
Genesis™ Master with Remote Floor Proximity LED Exit
FEATURES
SPECIFICATIONS
Genesis GXM, GXEM “Over the Door” & FP-GX “Floor Proximity” Tandem Exit Signs (must be ordered together)
Supply and Install Lightalarms® Genesis™ GXM, GXEM & FP-GX Series. The GXM, GXEM Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy. FP-GX Exit Sign shall be specified as single face, surface mount or recessed mount. The GXM, GXEM faceplate, backplate and canopy shall be constructed of die-cast aluminum. Backplate and canopy shall be matching in color, (W) white (B) black or (A) brushed aluminum Faceplate shall be (W) white, (B) black or (A) brushed aluminum with a (R) red or (G) green legend. Snap together clam shell design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The FP-GX faceplate shall be constructed of die-cast aluminum. Faceplate shall be (W) white, (B) black or (A) brushed aluminum with a (R) red or (G) green legend. Four screws shall be necessary to hold the faceplate and backbox together. The faceplate does not have chevron indicators. The single face Exit Sign shall be suitable for wall surface mount, or wall recessed mount installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” or 8” inch high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. GXM, AC-Only models shall be 120/277VAC, 60Hz, with a power consumption of 1.5W. GXEM, Self-Powered models shall be 120/277VAC, 60Hz, with a power consumption of 3.8W and supplied with a sealed maintenance-free NickelCadmium battery, providing at least 90 minutes illumination upon AC failure to itself including the FP-GX Exit Sign. GXEM Self-Powered Exit Sign with Improved Diagnostics shall include a self-test and silent diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected the pilot light shall change color from green to red and flash with a specific code. The red light is steady-on in case of a battery disconnect; it will flash with one blink for battery failure; two blinks for charger failure and four blinks for LED lamp failure. A label with the diagnostic legend shall be visible next to the pilot light. FP-GX, Exit Sign emergency operation is provided by a GXEM Exit Sign or a GXE Exit Sign with a AC-Only 2 circuit back-up system. The Exit Sign shall be CSA-US Approved, evaluated to UL 924 Standards, and meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty.
™
Construction • GXM, GXEM “Over the Door” exit faceplate, backplate and canopy are made of die-cast aluminum • GXM, GXEM offers a choice of 6 inch or 8 inch EXIT lettering legend, available in Red or Green • FP-GX “Floor Proximity” exit faceplate is made of die-cast aluminum; backbox is made of 20 gauge steel • FP-GX offers 6 inch EXIT lettering legend, available in Red or Green Mounting • GXM, GXEM Surface Mount only • Single face model includes (1) faceplate, (1) back-plate and (1) canopy • Canopy included for ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications • FP-GX Surface Mount or Recessed Mount • Single face model only Finishes • Choice of finishes: white, black or brushed aluminum Chevrons • GXM, GXEM faceplate includes two field-selectable, knock-out chevron indicators • FP-GX faceplate does not include chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • GXM, GXEM Self-Powered model standard with Improved Diagnostics Special Wording Panel • Not Available Approvals • Listed to UL 924 Standards • CSA-US Approved • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES Wire Guard (for floor proximity recessed)
WG11-L
The “over the door” Exit Sign shall be Lightalarms® Model ______________________________ The “floor proximity” Exit Sign shall be Lightalarms® Model ______________________________
20
www.lightalarms.com
US
TYPE
Combine style, performance and durability with added safety. The floof level indicator provides a egress path even if the ceiling Exit Sign is not totally visible due to rising smoke.
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. Over the Door Exits
Floor Proximity Surface Mount Exits 14-1/8” [35.88 cm]
8-7/8” [22.54 cm]
13-1/4” [33.65 cm]
1-5/8” [4.13 cm]
15-1/2” [39.37 cm] 13-7/8” [35.25 cm]
1-1/8” [2.86 cm]
1-1/8” [2.86 cm]
4 Vandal Resistant Screws
8-5/8” [21.91 cm]
Red or Green LED Light Source Polycarbonate Lens
Floor Proximity Recessed Mount Exits
Red or Green LED Light Source
+
+
Polycarbonate Lens
Mounting Center 4 Vandal Resistant Screws
9-3/4” 8-1/16” [24.77 cm] [20.48 cm]
Mounting Center
HOW TO ORDER TYPICAL APPLICATIONS (Must be ordered as a Tandem, over the door with a floor proximity Exit Sign) Self-Powered GXEM (over the door) exit with a FPGXLDM (floor proximity) exit tandem 120/277 Volt Input
Self-Powered over the door Example Model #: GXEMBRA-N
EXIT
AC-Only GXM (over the door exit) with a FPGXLD (floor proximity) exit tandem 120/277 Volt Input
AC-Only over the door Example Model #: GXMBRA-N
EXIT
Low Voltage Wire
EXIT
Low Voltage Wire
Floor-proximity Surface Mount Example Model #: BFPGXLDMRS
EXIT
Floor-proximity Surface Mount Example Model #: BFPGXLDRS
POWER CONSUMPTION CHART MODEL RED
AC SPECS
DC SPECS
AC-Only
120/277VAC, 60Hz
1.5W
–
–
AC-2 Circuit
120/120VAC and 277/277VAC, 60Hz
2.6W
–
–
Self-Powered
120/277VAC, 60Hz
3.8W
Nickel-Cadmium battery
Minimum of 90 minutes
AC-Only
120/277VAC, 60Hz
0.9W
–
–
120/120VAC and 277/277VAC, 60Hz
3.3W
–
–
120/277VAC, 60Hz
5W
Nickel-Cadmium battery
Minimum of 90 minutes
GREEN AC-2 Circuit Self-Powered
ORDERING FORMAT (Must order “Over the Door” GX or GXM Exit Sign and a “Floor Proximity” FP-GL Exit Sign as a tandem) Over the Door Exit Sign SERIES GXM= AC-Only or 2 circuit model GXEM= Self-Powered
FRAME COLOR A= Brushed Aluminum Body B= Black Body W= White Body
LEGEND COLOR R= Red G= Green
FACE PLATE COLOR
VERSION
A= Brushed Aluminum B= Black W= White
-N
OPTION -2= 2 circuit (120/120 or 277/277) (For use with GXM Series)
EXAMPLE: GXEMBRA-N
Floor Proximity Exit Sign FRAME COLOR A= Brushed Aluminum Body B= Black Body W= White Body
SERIES FPGXLD= For use with GXM Series
LEGEND COLOR R= Red G= Green
TRIM R= Recessed Mount S= Surface Mount
OPTION -VR= Vandal Resistant Polycarbonate lens and screws
EXAMPLE: BFPGXLDMRS
www.lightalarms.com
21
GENESIS
TM
GX & GXE SERIES
Die-Cast Aluminum LED Exit Sign
FEATURES
SPECIFICATIONS
Construction • Faceplate, backplate and canopy are made of die-cast aluminum • Choice of 6 inch or 8 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Genesis™ GX, GXE Series. The Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy and specified as double face shall be standard with (2) faceplates and (1) canopy. The faceplate, backplate and canopy shall be constructed of die-cast aluminum. Frame, backplate and canopy shall be matching in color, (W) white (B) black or (A) brushed aluminum Faceplate shall be (W) white, (B) black or (A) brushed aluminum with a (R) red or (G) green legend. Snap together clam shell design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” or 8” inch high by 3/4” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120-347VAC, 50/60Hz with power consumption of 1.25W in 6” and 2.5W in 8” models and include wiring to allow for DC emergency operation from an external 6VDC to 48VDC battery source, consuming only 1.5W in DC-remote operation. Self-Powered models shall be 120-347VAC, 50/60Hz, with power consumption of 1.5W in 6” and 2.6W in 8” models and supplied with a sealed maintenancefree Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. Self-Powered Exit Sign with Improved Diagnostics shall include a self-test and silent diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected the pilot light shall change color from green to red and flash with a specific code. The red light is steady-on in case of a battery disconnect; it will flash with one blink for battery failure; two blinks for charger failure and four blinks for LED lamp failure. A label with the diagnostic legend shall be visible next to the pilot light. The Exit Sign shall be CSA-US Approved and evaluated to UL 924 standard for Damp location optional (50°F to 104°F, 10°C to 40°C). The Exit Sign shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model ___________________________.
Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back-plate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Choice of finishes: white, black or brushed aluminum • Optional Dark Bronze or Polished Brass available Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Self-Powered models standard with Improved Diagnostics • NEXUS® Wired or Wireless system compatible Special Wording Panel • Available. Contact your sales representative with your design requirements Approvals • CSA-US Approved • Evaluated to UL 924. Damp location optional (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Pendant Mount White Pendant Mount Black Pendant Mount Gray Wire Guard (Wall Mount) (6 in.) Wire Guard (Ceiling Mount) (6 in.) Wire Guard (End Mount) (6 in.) Vandal Shield (Wall Mount) Vandal Shield, NEMA-4X (Wall Mount)
GPW-* GPB-* GPA-* WG13-L WG14-L WG15-L VRC VRC-4X
*Specify length of pendant (12”, 24”, 36”, etc.)
22
www.lightalarms.com
US
TYPE
Combine visual appeal, durability and energy efficiency in a compact, contemporary design. For added reliability choose Self-Powered models that include self-diagnostics as a standard feature.
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 4-5/8” [11.75 cm]
7/8” [2.23 cm]
6-1/4” [15.88 cm] aa
LETTERS 6” [15.24 cm] 8” [20.32 cm]
bb
DIMENSIONS
Dim a 8-7/8” [22.54 cm] 10-1/2” [26.67 cm]
Dim b 13-1/16” [33.18 cm] 15-1/4” [38.74 cm]
1-3/4” [4.45 cm]
POWER CONSUMPTION CHART MODEL (6 inch EXIT legend)
AC SPECS
DC SPECS
AC-only
120/347VAC, 50/60Hz
1.25W
–
–
AC/DC
120/347VAC, 50/60Hz
1.25W
6 to 48VDC
Less than 1.5W
Self-Powered
120/347VAC, 50/60Hz
1.6W
Nickel-Cadmium battery
Minimum of 90 minutes
MODEL (8 inch EXIT legend) AC-only
AC SPECS 120/347VAC, 50/60Hz
DC SPECS
2.5W
AC/DC
120/347VAC, 50/60Hz
2.5W
6 to 48VDC
1.6W
Self-Powered
120/347VAC, 50/60Hz
2.9W
Nickel-Cadmium battery
Minimum of 90 minutes
ORDERING FORMAT NO. OF FACE Blank= 6” single face 2= 6” double face 8= 8” single face 82= 8” double face
SERIES GX= A C-Only GXE= Self-Powered
BACK PLATE/ FRAME COLOR A= Brushed Aluminum B= Black W= White Optional DB= Dark Bronze (painted) PB= Polished Brass CH= Polished Chrome
LEGEND COLOR R= Red G= Green
FACE PLATE COLOR A= Brushed Aluminum B= Black W= White
DIAGNOSTIC OPTION1 Blank= S tandard Improved Diagnostic (non-audible) NEX= NEXUS® Wired2,3
Optional DB= Dark Bronze (painted) PB= Polished Brass CH= Polished Chrome
Available with Self-Powered GXE exit only NEX is CSA-US approved only 3 Consult your sales representative
OPTIONS Blank= No option -DC= AC/DC 6-48VDC1 -DL= Damp location -FAF= Fire Alarm Flasher -FB= F lasher Buzzer (Self-Powered only)2 -VR= Vandal Resistant Screws -LVR= V andal Resistant Polycarbonate lens and screws -Y= Open faceplate and Special wording faceplate -2= 2 Circuit (120/120 or 277/277, AC-Only)
VERSION -N
1 2
1 2
Available with GX model only Not available with Nexus® option
EXAMPLE: GXEARA-N
www.lightalarms.com
23
GALAXY SERIES
TM
TYPE
XD & XDN
CATALOG #
Die-Cast Aluminum LED Exit Sign. Superior workmanship, versatile mounting capabilities and long lasting LED performance in an economical design
FEATURES
Construction • Frame, faceplate, backplate and canopy are made of die-cast aluminum • 6 inch EXIT lettering legend available in Red or Green Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back-plate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box used in wall mount applications Finishes • Choice of finishes: white, black or brushed aluminum Chevrons • Faceplate includes two field-selectable, knock-out, chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Self-Powered models available with or without Improved Diagnostics • NEXUS® wired or wireless system compatible. Special Wording Panels: • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • Option: UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
DIMENSIONS
Dimensions are approximate and subject to change.
1-7/8” [4.76 cm]
8-5/8” [21.91 cm]
9-1/8” [23.18 cm]
5-1/2” [13.97 cm]
4-3/8” [11.11 cm]
12-7/8” [32.70 cm]
NOTES
SPECIFICATIONS
Supply and Install Lightalarms® Galaxy™ XD, XDN Series. The Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy and specified as double face shall be standard with (2) faceplates and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of die-cast aluminum. Frame, backplate and canopy shall be matching in color, (W) white (B) black or (A) brushed aluminum. Faceplate shall be (W) white, (B) black or (A) brushed aluminum with a (R) red or (G) green legend. Snap together design, no screws needed to hold the frame, faceplate(s) or backplate together. The faceplate includes two removable knockout chevrons. Single face Exit Sign shall be for surface, wall, end or ceiling installations. Double face Exit Sign shall be for surface, end or ceiling installations. Illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. A color matching LED sensitive legend of (R) red or (G) green, shall be mounted in front of the LEDs to provide 6” high by 3/4” stroke EXIT letters evenly illuminated, no visible LEDs or hot spots. AC-Only models; 120/277VAC, 60Hz, power consumption less than 2.5W. AC/DC models; 120/277VDC, 60Hz, power consumption less than 2W, DC operation, 6VDC to 48VDC, using less than 1.5W. Self-Powered models; 120/277VAC, 60Hz, power consumption less than 3W, with Self-Diagnostics option, less than 2.8W, each supplied with a sealed maintenancefree Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. Self-Powered Exit Sign with Improved Diagnostics include a self-test and diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. Diagnostic circuit shall continuously monitor the performance of the battery, charger and LED lamps. When a fault is detected the pilot light will change from green to red and flash. Flash legend indicating the fault shall be next to the pilot light. The Exit Sign shall be listed to UL 924 standards, UL listed for Damp location (50°F to 104°F, 10°C to 40°C) optional and meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
POWER CONSUMPTION CHART MODEL
AC SPECS
DC SPECS
AC-Only
120/277VAC, 60Hz
Less than 2.5W
–
AC / DC-remote
120/277VAC, 60Hz
Less than 2W
6 to 48VDC
Less than 1.5W
Self-Powered
120/277VAC, 60Hz
Less than 3.3W
Nickel-Cadmium battery
Min. 90 minutes
Self-Powered with Diagnostic
120/277VAC, 60Hz
Less than 2.8W
Nickel-Cadmium battery
Min. 90 minutes
–
ORDERING FORMAT NO. OF FACE 1= Single face 2= Double face
SERIES Standard Models XDA= AC-Only XDC= AC/DC XDND= Self-Powered WITH Improved Diagnostics XDN= Self-Powered WITHOUT Improved Diagnostics Optional Models XD21= Dual AC circuit (2 x 120V) XD22= Dual AC circuit (2 x 277V) XDNEX= NEXUS® Wired1 XDNEXRF= NEXUS® Wireless1 1
BACKPLATE/ FRAME COLOR B= Black W= White A= Brushed aluminum
LEGEND/FACEPLATE COLOR RB= Red/Black GB= Green/Black RW= Red/White GW= Green/White RA= Red/Brushed Aluminum GA= Green/Brushed Aluminum
Consult your sales representative.
Blank= No option -FB= Flasher buzzer1 -FL= Flasher1 -FAF= Fire Alarm Flasher (not available with XDN model) -FBF= Fire alarm activated flasher and Flasher Buzzer1 -VR= Vandal Resistant Screws -LVR= Vandal Resistant Polycarbonate lens and screws -DL= Damp location (50°F minimum, 104°F maximum ambient, 10°C minimum, 40°C maximum) -Y= Open faceplate and special wording faceplate For Pendant Kit see p. 51 1
EXAMPLE: 2XDABRB 24
OPTIONS
www.lightalarms.com
Available with XDND, XDNEX, and XDNEXRF only.
TYPE
GALAXY SLIM TX & TXE SERIES TM
CATALOG #
NOTES
Die-Cast aluminum slim profile Exit Sign with long-lasting LED performance
FEATURES
SPECIFICATIONS
Construction • Faceplate, backplate and canopy are made of die-cast aluminum • 6 inch EXIT lettering legend, available in Red or Green
Warranty • Five-Year full warranty (subject to proper installation and maintenance)
Supply and Install Lightalarms® Galaxy™ Slim TX, TXE Series. The Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy and specified as double face shall be standard with (2) faceplates and (1) canopy. The faceplate, backplate and canopy shall be constructed of die-cast aluminum. Backplate and canopy shall be matching in color, (W) white or (B) black. Faceplate shall be (W) white (with a white backplate) or (A) brushed aluminum (with a black backplate) covered with a clear lacquer finish. Snap together design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120/277VAC, 60Hz, with a maximum power consumption of 1.5W. Self-Powered models shall be 120/277VAC, 60Hz, maximum 1.5W and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. The Exit Sign shall be tested by Underwriters Laboratories, listed to UL 924 standards, and UL listed for Damp location (32°F to 122°F, 0°C to 50°C) and meets NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
ACCESSORIES
DIMENSIONS
Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back-plate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Choice of finishes: all white, or black with brushed aluminum faceplate • Clear lacquer finish inhibits fingerprints and other contaminants Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Not Available Special Wording Panels • Not Available Approvals • Listed to UL 924 Standards for Damp location (32°F to 122°F, 0°C to 50°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards
Dimensions are approximate and subject to change.
(Order as a separate item) WG1-L WG5-L
4-3/8” [11.1 cm]cm] 4-3/8” [11.1
MODEL
AC SPECS
DC SPECS
AC-Only
120/277VAC, 60Hz
Typical 1W
Less than 1.5W
–
–
Self-Powered
120/277VAC, 60Hz
Less than 3.3W
Less than 1.5W
Ni-Cd battery
Min. 90 minutes 7/8”7/8” [2.2[2.2 cm]cm]
5-1/8” [13 cm] 5-1/8” [13 cm]
POWER CONSUMPTION CHART
3/8”3/8” [1 cm] [1 cm]
7-3/4” [19.7 cm] 7-3/4” [19.7 cm]
8-1/8” [20.6 cm] 8-1/8” [20.6 cm]
Wire Guard (Wall Mount) Wire Guard (Ceiling Mount and End Mount)
11-7/8” [30.2 cm]cm] 11-7/8” [30.2 12-1/4” [31.1 cm]cm] 12-1/4” [31.1
ORDERING FORMAT NO. OF FACE Blank= Single Face 2= Double Face
SERIES TX= AC-Only TXE= Self-Powered
BACKPLATE COLOR W= White B= Black
LEGEND COLOR R= Red G= Green
FACEPLATE COLOR W= White (only available with white backplate) A= B rushed Aluminium (only available with black backplate)
EXAMPLE: TXEWRW
www.lightalarms.com
25
GALAXY
TM
XDPC SERIES
Die-Cast Aluminum Remote Capacity Exit Sign
FEATURES
SPECIFICATIONS
Construction • Frame, faceplate, backplate and canopy are made of die-cast aluminum • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Galaxy™ XD Series. The Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy and specified as double face shall be standard with (2) faceplates and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of die-cast aluminum. Frame, backplate and canopy shall be matching in color, (W) white (B) black or (A) brushed aluminum Faceplate shall be (W) white, (B) black or (A) brushed aluminum with a (R) red or (G) green legend. Snap together design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by 3/4” stroke EXIT letters with even illumination and no visible LEDs or hot spots. PCL Self-Powered models shall be 120/277VAC, 60Hz, 0.13/0.06Amp and supplied with a sealed maintenance-free Lead-Calcium battery, with 6V-9W remote capacity, providing at least 90 minutes illumination upon AC failure. PCN Self-Powered models shall be 120/277VAC, 60Hz, and supplied with a sealed maintenance-free Nickel-Metal Hydride battery, with 6V-12W remote capacity, providing at least 90 minutes illumination upon AC failure. PCX Self-Powered models shall be 120/277VAC, 60Hz, 0.13/0.06Amp and supplied with a sealed maintenance-free Nickel-Metal Hydride battery, with 6V-24W remote capacity, providing at least 90 minutes illumination upon AC failure. When specified, the unit equipment with Improved Diagnostics shall include a self-test and diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. If a fault is indicated, the external service required indicator will illuminate. The Exit Sign shall be tested by the Underwriters Laboratories, listed to UL 924 standards, and UL listed for Damp location (32°F to 122°F, 0°C to 50°C). The Exit Sign shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back plate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for wall, end or ceiling mount applications Finishes • Choice of finishes: white, black or brushed aluminum Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Remote Capacity • PCL Model, (Lead-Calcium battery) 6V-9W remote load capacity (20+ hours of operation with no remote load connected) • PCN Model, (Nickel-Metal Hydride battery) 6V-12W remote load capacity (20+ hours of operation with no remote load connected) • PCX Model, (Nickel-Metal Hydride battery) 6V-24W remote load capacity (40+ hours of operation with no remote load connected) Self-Diagnostics • Self-Powered models available with or without Improved Diagnostics Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • Option: UL listed for Damp location (32°F to 122°F, 0°C to 50°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES Wire Guard, Back Mount Wire Guard, Ceiling Mount
26
WG13-L WG14-L
www.lightalarms.com
TYPE
Self-Powered LED Exit Signs with excess battery capacity to power remote emergency head or Exit Signs
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. Ceiling Mount
End Mount
Back Mount
15-1/4” [38.73 cm]
12-7/8” [32.70 cm]
12-1/4” [32.70 cm]
6-1/4” [15.87 cm]
8-1/8” [20.63cm]
10-7/8” [27.62 cm]
1-7/8” [4.76 cm]
12-7/8” [32.70 cm]
8-1/2” [21.59 cm]
8-1/8” [20.63 cm]
1-7/8” [4.76 cm]
6-1/4” [15.87 cm]
8-1/2” [21.59 cm]
8-1/8” [20.63 cm]
8-1/2” [21.59 cm]
1-7/8” [4.76 cm]
POWER CONSUMPTION/UNIT RATING CHART SERIES
AC SPECS AC Input
XDPCL XDPCN XDPCL
Maximum
120/277VAC, 60Hz
0.13/0.06A 15W
DC SPECS - WATTS TO 87.5% OF RATED BATTERY VOLTAGE* Voltage
Battery
1-1/2 hrs.
2 hrs.
3 hrs.
6V
Lead-Calcium
9
–
–
4 hrs. –
6V
Nickel-Metal Hydride
12
9
–
–
6V
Nickel-Metal Hydride
24
18
12
9 *National Electrical Code Specification
ORDERING FORMAT NO. OF FACE
SERIES
1= Single face 2= Double face
XDPC= LED Exit
BATTERY Lead-Calcium PCL= 6V-9W remote capacity Nickel Metal Hydride PCN= 6V-12W remote capacity PCX= 6V-24W remote capacity
BACKPLATE/FRAME COLOR B= Black W= White A= Brushed Aluminum
LEGEND/FACEPLATE COLOR RB= Red/Black GB= Green/Black RW= Red/White GW= Green/White RA= Red/Brushed Aluminum GA= Green/Brushed Aluminum
OPTIONS Blank= No options -ID= Improved Diagnostics (audible) -IDNA= Improved Diagnostics (non-audible) -T1= Time Delay (5 minutes)1 -T2= Time Delay (10 minutes)1 -T3= Time Delay (15 minutes)1 -FB= Flasher Buzzer2 -FAF= Fire Alarm Flasher2 -DL= Damp location -VR= Vandal Resistant Screws -LVR= Vandal Resistant Polycarbonate lens and screws
1 2
Comes standard with ID and IDNA options Not available with ID and IDNA options
EXAMPLE: 2XDPCLBRAIDNA
www.lightalarms.com
27
UX4 LED STEEL EXIT & COMBINATION SERIES Steel LED Exit Signs and Combination Units
FEATURES
SPECIFICATIONS
Construction • Frame, faceplate and backplate are made of 20 gauge steel, canopy is made of Thermoplastic • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® UX4 LED Steel Exit & Combination Series. The Exit Sign or combination unit shall be standard with (2) faceplates, (1) backplate and (1) canopy. The frame, faceplate, and backplate shall be constructed of 20 gauge steel, canopy shall be Thermoplastic. Frame, faceplate, backplate and canopy shall be matching in color, (W) white or (B) black. Faceplate shall be (W) white or (B) black with a (R) red or (G) green legend. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The Exit Sign or Combination Unit shall be suitable for surface mount, wall, end or ceiling installations. The Exit illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only UX4 models shall be 120/277VAC, 60Hz, with a power consumption of less than 1.5W and also wired for AC/DC 6VDC to 24VDC operation. Self-Powered UX4N models shall be 120/277VAC, 60Hz, with a power consumption of less than 3W and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes, illumination upon AC failure. Combination UX4E models shall be 120/277VAC, 60Hz, with power consumption of less than 5W and supplied with a sealed maintenance-free 6V-30W load capacity Lead-Calcium battery providing at least 90 minutes, illumination upon AC failure. Combination models UX4EN model shall be 120/277VAC, 60Hz, with a power consumption of less then 5W and supplied with a sealed maintenance-free 6V-24W load capacity Nickel-Cadmium battery providing at least 90 minutes, illumination upon AC failure. The Exit Sign shall be tested by Underwriters Laboratories, listed to UL 924 standards. The Exit Sign or Combination Unit shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a three-year full warranty. The Exit Sign or Combination Unit shall be Lightalarms® Model _______________.
Mounting • Surface Mount • Model includes (2) faceplates, (1) backplate and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Choice of finishes: white or black • Optional brushed aluminum faceplate available Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators Exit Legend LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Remote Capacity/Combination units • UX4E Model, Lead-Calcium battery, 6V-30W total battery capacity • UX4EN Model, Nickel-Cadmium battery, 6V-24W total battery capacity • UX4EX Model Nickel-Cadmium battery, 6V-20W total battery capacity Exit sign • UX4 Model, Exit Sign, AC-Only, 120/277VAC, 50/60Hz • UX4N Model, Nickel-Cadmium battery Lamp Head Source • Choice of Wedge Base Incandescent 6V up to 9W • Choice of Bi-Pin Halogen 6V up to 12W • Choice of MR16 6V up to 10W Self-Diagnostics • Self-Powered E and EX models available with or without Improved Diagnostics Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • Meets NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards Warranty • Three-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
POWER CONSUMPTION CHART MODEL
120/277VAC, 50/60Hz
Less than 1.5W
AC/DC
120/277VAC, 50/60Hz
Self-Powered Combination
(Order as a separate item) White Pendant Black Pendant Wire Guard (Exit-Ceiling or End Mount) Wire Guard (Exit-Wall Mount) Wire Guard (Combination Unit-Wall Mount) *Specify Pendant length (12”, 24”, 36” etc.)
PW-* PB-* WG5-L WG12-L WG6-L
AC SPECS
AC-Only
–
–
Less than 1.5W
6 to 24VDC
Less than 1.5W
120/277VAC, 50/60Hz
Less than 3W
Nickel-Cadmium
Minimum 90 minutes
120/277VAC, 50/60Hz
Less than 5W
See Unit Rating Chart
UNIT RATING CHART (Combination Unit) BATTERY TYPE Lead-Calcium
DC VOLTAGE (VOLTS)
MODEL
1-1/2 hrs. 2 hrs.
3 hrs.
4 hrs.
6
UX4E
30
20
14
10
UX4EN
24
18
12
9
Nickel-Cadmium *National Electrical Code Specification
28
DC SPECS
www.lightalarms.com
WATT TO 87.5% OF RATED BATTERY VOLTAGE*
!
NEW
AVAILABLE WITH LED LAMP HEADS
TYPE
20 gauge steel LED Exit Sign and Combination Unit designed for easy installation. Energy efficient and rugged in design.
CATALOG #
NOTES
4-5/8” [11.75 cm]
Shown with ELF2 (suffix 2M) Heads 7-5/8”
7-3/8” [18.73 cm]
DIMENSIONS
[19.37 cm]
12-1/8” Available Head Style Choices: [30.80 cm] ELF645 (SUFFIX 1L & 2L)
Dimensions are approximate and subject to change. UX4 AC/DC-Only Exit Sign
UX4E Combination Unit
UX4N Self-Powered Exit Sign
UX4EN Combination Unit 4-5/8” [11.75 cm]
7-3/8” [18.73 cm]
UX4= Universal (2) faceplates, (1) backplate and (1) canopy
Blank= AC-only N= Self-Powered
4-5/8” [11.75 cm]
6-1/8” [15.56 cm]
12-1/8” [30.80 cm]
1-1/4” [3.175 cm]
BACKPLATE/FRAME COLOR
12-1/4” [31.12W= cm]White B= Black 7-3/8” [18.73 cm]
6-1/8” [15.56 cm]
12-1/8” [30.80 cm]
1-1/4” [3.175 cm]
7-3/8” [18.73 cm] 2-1/8” [5.40 cm]
BATTERY TYPE
4-5/8” [11.75 cm]
ELF3
12-1/4” [31.12 cm]
12-1/8” [30.80 cm]
SERIES
2-1/8” ELF2 [5.40(SUFFIX cm] 1M & 2M)
1-1/4” [3.175 cm]
7-5/8” [19.37 cm]
ORDERING FORMAT AC-only and Self-Powered Models
1-1/4” [3.175 cm]
LEGEND/ FACEPLATE COLOR RW= Red/White RB= Red/Black RA= Red/Aluminum GW= Green/White GB= Green/Black GA= Green/Aluminum
LEGEND SOURCE LED= LED
OPTIONS Blank= No options -IDNA= Improved Diagnostics (non-audible)1 -DC= AC/DC 6V-24VDC -VR= Vandal Resistant Screws -LVR= Vandal Resistant Polycarbonate Screws & Lens -NEX= Nexus® Wired1 -NEXRF= Nexus® Wired1 1
Available in Self-Powered only
EXAMPLE: UX4WRWLED
Combination Units SERIES
UNIT TYPE
UX4= Universal (2) faceplates, (1) backplate and (1) canopy
E= 6V-30W Lead-Calcium battery EN= 6V-24W NickelCadmium battery EX= 6V-20W NickelCadmium battery
BACKPLATE/ LEGEND/ LEGEND FRAME COLOR FACEPLATE COLOR SOURCE W= White B= Black
RW= Red/White RB= Red/Black RA= Red/Aluminum GW= Green/White GB= Green/Black GA= Green/Aluminum
LED= LED
LAMP HEAD SUFFIX /0= No heads /1L= (1) ELF645 head /2L= (2) ELF645 heads /1M= (1) ELF2 head /2M= (2) ELF2 heads /1ELF3= (1) ELF3 head /2ELF3= (2) ELF3 heads
LAMP OPTIONS Use with ELF645 (suffix 1L & 2L) Only L9= 6V-9W Wedge Base Incandescent 4042= 6V-12W Sealed Beam Incandescent H7553= 6V-12W Sealed Beam Halogen Use with ELF2 (suffix 1M & 2M) Only L9= 6V-9W Wedge Base Incandescent LH6= 6V-12W Bin Pin Halogen
OPTIONS Blank= No Option -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non-audible)1 -T1= Time Delay 5 minutes -T2= Time Delay 10 minutes -T3= Time Delay 15 minutes -VR= Vandal Resistant Screws -LVR= V andal Resistant Screws & Lens -NEX= Nexus® Wired1 (combo unit only) -NEXRF= Nexus® Wireless1 (combo unit only)
Use with ELF3 (suffix 1ELF3 & 2ELF3) Only M10= 6V-10W MR16 Halogen LD1= 6V-4W MR16 LED 1
Not available with EN model
EXAMPLE: UX4EWRWLED/2LH7553
www.lightalarms.com
29
GRANDE
TM
EXIT SERIES
Specification-grade, LED, Thermoplastic, Snap Together Exit Sign
FEATURES
SPECIFICATIONS
Construction • Frame, faceplate, backplate and canopy are made of Thermoplastic • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Grande™ Exit Series. The Exit Sign specified as a universal model includes (2) faceplates, (1) backplate and (1) canopy, specified as single face includes (1) faceplate, (1) backplate and (1) canopy, specified as double face includes (2) faceplates and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of injection-molded Thermoplastic. Frame, backplate and canopy shall be matching in color, (W) white or (B) black. Faceplate shall be (W) white, (B) black or optional (A) brushed aluminum with a (R) red or (G) green legend. Snap together design allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable snap-in/out chevron indicators. The universal and single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. Based on the test results, the authors estimate that ALINGAP LEDs exposed to 100,000 hours (11.4 years) of continuous use at an ambient temperature of +55°C AC-Only models shall be 120/277VAC, 60Hz, with a power consumption of less than 2.5W. AC/DC models shall be 120/277VAC, 60Hz, with a power consumption of less then 2W and allows for DC operation from 6VDC to 48VDC. Self-Powered models shall be 120/277VAC, 60Hz, with a power consumption of less than 3.3W and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes, illumination upon AC failure. When specified, the Self-Powered Exit Sign with Improved Diagnostics shall include a self-test and silent diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected, the pilot light shall change color from green to red and flash with a specific code. The red light is steady-on in case of a battery disconnect; it will flash with one blink for battery failure; two blinks for charger failure and four blinks for LED lamp failure. A label with the diagnostic legend shall be visible next to the pilot light. The Exit Sign shall be tested by Underwriters Laboratories, listed to UL 924 standards. UL listed for Damp location (50°F to 104°F, 10°C to 40°C). The Exit Sign shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
Mounting • Surface Mount • Universal model includes (2) faceplates, (1) backplate and (1) canopy • Single face model includes (1) faceplate, (1) backplate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Choice of finishes: white or black • Optional brushed aluminum faceplate stencil available Chevrons • Faceplate includes two field-selectable, snap-in/out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Self-Powered models available with or without Improved Diagnostics • NEXUS® Wired or Wireless system compatible Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) WG1-L WG5-L
Wire Guard (Wall Mount) Wire Guard (Ceiling Mount and End Mount)
POWER CONSUMPTION CHART MODEL
AC SPECS
DC SPECS
AC-Only
120/277VAC, 60Hz
Less than 2.5W
–
AC / DC-remote
120/277VAC, 60Hz
Less than 2W
6 to 48VDC
Less than 1.5W
Self-Powered
120/277VAC, 60Hz
Less than 3.3W
Nickel-Cadmium battery
Min. 90 minutes
Self-Powered with Diagnostic
120/277VAC, 60Hz
Less than 2.8W
Nickel-Cadmium battery
Min. 90 minutes
30
–
www.lightalarms.com
TYPE
Compact with an all-in-one, snap-fit design. Easy to install and affordable. Ideally suited for spec-grade applications
CATALOG #
NOTES
DIMENSIONS
8” [20.82 cm]
9” [22.86 cm]
Dimensions are approximate and subject to change.
11-7/8” [30.16 cm] 12-7/8” [32.71 cm]
2” [5.08 cm]
ORDERING FORMAT SERIES GRAN
UNIT TYPE Standard Models AC= AC-Only (120/277V ) DC= 120/277VAC & 6 to 48VDC N= Self-Powered Nickel-Cadmium Optional Models 21= Dual AC circuit (2x120V) 22= Dual AC circuit (2x277V) ND= Self-Powered with Improved Diagnostic circuitry -NEX= Nexus® Wired1 -NEXRF= N exus® Wireless1
LEGEND COLOR / # OF FACE R= Red Universal R1= Red single face R2= Red double face G= Green Universal G1= Green single face G2= Green double face Open face1 RW= Red on White GW= Green on White Universal= (2) faceplates, (1) backplate and (1) canopy Single Face= (1) faceplate, (1) backplate and (1) canopy
HOUSING COLOR W= White B= Black
OPTIONS -BA= Brushed Aluminum exit stencil -FB= Flasher Buzzer (ND model only) -FL= Flasher (ND model only) -FAF= F ire Alarm activated Flasher (AC, DC, 21,22 or ND models only) -FBF= Flasher Buzzer + Fire Alarm activated Flasher (ND model only) -VR= Vandal Resistant Screws -LVR1= Vandal Resistant Polycarbonate lens and screws -PM= Pendant Mount For Pendant Kit see p. 51
Double Face= (2) faceplates and (1) canopy 1 Consult
your sales representative
1 Open
face required with special wording legends
EXAMPLE: GRANACRW
GRANDE™ THERMOPLASTIC FAMILY The Grande™ Exit Sign is a part of the Grande™ family of Thermoplastic emergency lighting products. The Grande™ family offers complete emergency lighting solutions where style and design are required in an economical package.
Grande™ Combination Series p.32-33
Grande™ Battery Series p.74-75
www.lightalarms.com
ELF640 (indoor) & ELF650 (outdoor) Remote Series p.110-111
31
GRANDE
TM
COMBINATION SERIES
Specification-grade, LED, Thermoplastic, snap-together Combination Unit
FEATURES
Construction • Frame, faceplate, backplate and canopy are made of Thermoplastic • Clear polycarbonate lens covers • 6 inch EXIT lettering legend, available in Red or Green Mounting • Surface Mount • Universal model includes (2) faceplates, (1) backplate and (1) canopy • Single face model includes (1) faceplate, (1) backplate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Choice of finishes: white or black • Optional brushed aluminum faceplate stencil available Chevrons • Faceplate includes two field-selectable, snap-in/out chevron indicators Exit Legend LEDS • Red or Green Long-Life Light Emitting Diodes (LED) illumination Remote Capacity/Combination Units • Lead-Calcium battery models offer a choice of 6V-12W, 6V-24W or 12V-24W total battery capacity • Nickel-Metal Hydride battery models offer a choice of 6V-12W, 12V-24W, 12V-40W or 12V-50W total battery capacity Lamp Head Source • Choice of MR16 6V up to 10W or 12V up to 12W • Choice of MR16 LED 6V-4W, 12V-4W, 12V-5W or 12V-6W with life expectancy 50,000+ hours • Lamp heads are fully adjustable with no tools required Self-Diagnostics • Models available with or without Improved Diagnostics • NEXUS® wired or wireless system compatible Special Wording Panels • Available, contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • Nickel-Metal Hydride battery combination units UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Wire Guard (Wall Mount) Pendant White Pendant Black
WG2-L GRA-P*-W GRA-P*-B
*Specify pendant length (12”, 24”, 36” etc)
Convert single face to double face in the field Red/White Red/Black Green/White Green/Black 32
005715-L 005716-L 005717-L 005718-L
SPECIFICATIONS
Supply and Install Lightalarms® Grande™ Combination Series. The Combination Unit specified as universal includes (2) faceplates, (1) backplate and (1) canopy, specified as single face includes (1) faceplate, (1) backplate and (1) canopy, specified as double face includes (2) faceplates and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of injection-molded Thermoplastic. Frame, backplate and canopy shall be matching in color, (W) white or (B) black. Faceplate shall be (W) white, (B) black or optional (A) brushed aluminum with a (R) red or (G) green legend. Snap together design allows for no screws being necessary to hold the faceplate(s) or backplate together or for removal and replacement of polycarbonate lens covers. The faceplate shall come standard with two field-selectable, removable snap-in/out chevron indicators. The universal and single face combination model shall be suitable for surface mount, wall or ceiling installations. The double face Combination Unit shall be suitable for surface mount ceiling installations.The EXIT illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the housing. A color matching LED sensitive legend diffuser of (R) red or (G) green shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. When specified, the unit shall be equipped with two emergency heads protected by snap-on, shock-absorbent, clear polycarbonate covers with tool-less adjustable swivels and MR16 halogen lamps or MR16 LED lamps as noted. Combination Units shall be 120/277VAC, 60Hz, with a power consumption of less than 2W for Exit Sign module operation and supplied with a sealed maintenance-free battery of Lead-Calcium or Nickel-Metal Hydride as noted, providing at least 90 minutes, illumination upon AC failure. 612M model shall be a 6V-12W Lead-Calcium battery with power consumption of 0.11/0.05A. 624M model shall be a 6V-24W Lead-Calcium battery with power consumption of 0.11/0.05A. 1224M model shall be a 12V-24W Lead-Calcium battery with power consumption of 0.22/0.08A. 612H model shall be a 6V-12W Nickel-Metal Hydride battery with power consumption of 0.11/0.05A 1224H model shall be a 12V-24W Nickel-Metal Hydride battery with power consumption of 0.22/0.08A 1240H model shall be a 12V-40W Nickel-Metal Hydride battery with power consumption of 0.22/0.08A 1250H model shall be a 12V-50W Nickel-Metal Hydride battery with power consumption of 0.22/0.08A When specified, the Combination Unit with Improved Diagnostics shall include a self-test and silent diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected, the pilot light shall change color from green to red and flash with a specific code. The red light is steady-on in case of a battery disconnect; it will flash with one blink for battery failure; two blinks for charger failure and four blinks for LED lamp failure. A label with the diagnostic legend shall be visible next to the pilot light.The Combination Unit shall be tested by Underwriters Laboratories, listed to UL 924 standards, and UL listed for Damp location (50°F to 104°F, 10°C to 40°C). The Combination Unit shall meetNFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The combination unit shall be Lightalarms® Model ___________________.
www.lightalarms.com
AVAILABLE WITH LED LAMP HEADS
!
NEW
TYPE
Designed with aesthetics, ease of installation, extra remote capacity and performance in mind
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change.
11-1/4” [27.94 cm]
12-3/8” [30.48 cm]
4-7/8” [10.16 cm]
17” [43.18 cm]
3-3/8” [7.62 cm]
POWER CONSUMPTION/UNIT RATING CHART SERIES GR612M
AC SPECS
DC SPECS - WATTS TO 87.5% OF RATED BATTERY VOLTAGE1
AC Input
Current Draw
Voltage
Battery
1-1/2 hrs
2 hrs.
3 hrs.
4 hrs.
120/277VAC, 60Hz
0.11/0.05A
6V
Lead-Calcium
12
8
–
–
GR612H
120/277VAC, 60Hz
0.11/0.05A
6V
Nickel-Metal Hydride
12
9
–
–
GR624M
120/277VAC, 60Hz
0.11/0.05A
6V
Lead-Calcium
24
16
12
9
GR1224M
120/277VAC, 60Hz
0.22/0.08A
12V
Lead-Calcium
24
16
12
9
GR1224H
120/277VAC, 60Hz
0.22/0.08A
12V
Nickel-Metal Hydride
24
18
12
9
GR1240H
120/277VAC, 60Hz
0.22/0.08A
12V
Nickel-Metal Hydride
40
30
20
15
GR1250H
120/277VAC, 60Hz
0.22/0.08A
12V
Nickel-Metal Hydride
50
36
24
18
National Electrical Code specification. Note: LED Exit AC Illumination draws less than 2W.
1
ORDERING FORMAT SERIES/BATTERY TYPE/CAPACITY Lead-Calcium GR612M= 6V-12W GR624M= 6V-24W GR1224M= 12V-24W
LEGEND COLOR R= Red G= Green
Nickel Metal Hydride Rated Damp location GR612H= 6V-12W GR1224H= 12V-24W GR1240H= 12V-40W GR1250H= 12V-50W
# OF FACE 1= Single face (ceiling or wall mount) 1N= Single face no canopy (wall mount) 2= D ouble face (ceiling mount) U= Universal 2 faces, backplate and canopy
HOUSING COLOR W= White B= Black
# OF HEADS Blank= No heads 2= Two heads
LAMP TYPE MR16 Halogen lamps M6= 6V-6W M10= 6V-10W M10= 12V-10W M12= 12V-12W MR16 LED Lamps LD1= 6V-4W LD7= 12V-4W LD9=12V-5W LD10=12V-6W
OPTIONS Blank= No option -BA= Brushed Aluminum exit stencil -FB= Flasher Buzzer -FL= Flasher -FAF= Fire Alarm activated Flasher -FBF= Flasher Buzzer + Fire Alarm activated Flasher -VR= Vandal Resistant Screws -LVR1= Vandal Resistant Polycarbonate lens and screws -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non-audible)1 -T3= Time Delay (15 minutes) -NEX= Nexus® Wired1 -NEXRF= Nexus® Wireless1 -PTS= Photocell test switch For Pendant Kit see p. 51 1
Not available with GR1250H
EXAMPLE: GR612MR1W2M6
GRANDE™ THERMOPLASTIC FAMILY The Grande™ Combination Unit is a part of the Grande™ family of Thermoplastic emergency lighting products. The Grande™ family offers complete emergency lighting solutions where style and design are required in an economical package.
Grande™ Exit Series p.30
Grande™ Battery Series p.74-75
www.lightalarms.com
ELF640 (indoor) & ELF650 (outdoor) Remote Series p.110-111
33
QUICK QLX & QLXN SERIES
TYPE
TM
Economical, Thermoplastic LED Exit Signs
CATALOG #
NOTES
FEATURES
SPECIFICATIONS
Construction • Frame, faceplate, backplate and canopy are made of Thermoplastic • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Quick™ QLX & QLXN Series. The Exit Sign specified as a universal model includes (2) faceplate, (1) backplate and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of injectionmolded Thermoplastic. Frame, backplate and canopy shall be mist-white in color. Faceplate shall be mist-white, with a (R) red or (G) green legend. Snap together design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable snap-in/out chevron indicators. The universal and single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. LED shall have rated lamp more than 30,000 hours. AC-Only models shall be 120/277VAC, 60Hz, maximum 2.5W. AC/DC models not available. Self-Powered models shall be 120/277VAC, 60Hz, with a power consumption of 2.5W and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes, illumination upon AC failure. Expected life of battery 15 years or more The Exit Sign shall be tested by Underwriters Laboratories, listed to UL 924 standards, and UL listed for Damp location (50°F to 104°F, 10°C to 40°C). The Exit Sign shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a three-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
Mounting • Surface Mount • Universal model includes (2) faceplates, (1) backplate and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Finished in mist-white Chevrons • Faceplate includes two field-selectable, snap-in/out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Diagnostic is available (see ordering format) Special Wording Panels • Not available Approvals • Listed to UL 924 Standards • UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Three-Year full warranty (subject to proper installation and maintenance)
DIMENSIONS
ACCESSORIES
Dimensions are approximate and subject to change.
(Order as a separate item) WG1-L WG5-L
Wire Guard (Wall Mount) Wire Guard (Ceiling Mount and End Mount)
POWER CONSUMPTION CHART 120/277VAC, 60Hz maximum 2.5W
ORDERING FORMAT SERIES QLX500= AC-Only QLXN500= Self-Powered
LEGEND COLOR RN= Red GN= Green
OPTIONS Blank= No option -ID= Improved Diagnostic1 7-1/4” [18.42 cm]
11-13/16” [30.01 cm] 1-13/16” [4.61 cm]
1
A vailable only with Self-Powered model, no remote capacity
EXAMPLE: QLXN500R 34
www.lightalarms.com
AVAILABLE WITH LED LAMP HEADS TYPE
QUICK UQLXN-2MR COMBINATION SERIES TM
CATALOG #
NOTES
Thermoplastic LED Combination Units
FEATURES
SPECIFICATIONS
Construction • Frame, faceplate, backplate and canopy are made of Thermoplastic • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Quick™ UQLXN-2MR Combination Series. The Combination Unit specified includes (2) faceplates, (1) backplate and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of injectionmolded Thermoplastic. Frame, backplate and canopy shall be mist-white. Faceplate shall be mist-white with a (R) red or (G) green legend. Snap together design allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable snap-in/out chevron indicators. The combination model shall be suitable for surface mount, end wall or ceiling installations. The EXIT illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by 3/4” stroke EXIT letters with even illumination and no visible LEDs or hot spots. Combination Units shall be equipped with two MR16 type emergency heads with either MR16 6V-5W halogen or 6V-4W LED as specified. Emergency heads are adjustable and can be aimed with no tools required. Combination Units shall be 120/277VAC, 60Hz, with power consumption of .1/.05A and supplied with a sealed maintenance-free Lead-Calcium battery, providing at least 90 minutes, illumination upon AC failure. The Combination Units sbe tested by Underwriters Laboratories, listed to UL 924 standards, and UL listed for Damp location (50°F to 104°F, 10°C to 40°C). The Combination Units shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a three-year full warranty. The combination unit shall be Lightalarms® Model ___________________.
Mounting • Surface Mount • Universal model includes (2) faceplates, (1) backplate and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box used in wall mount applications Finishes • Finished in mist-white Chevrons • Faceplate includes two field-selectable, snap-in/out chevron indicators Exit Legend LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Combination Units • Lead-Calcium battery models offer a choice of 6V-12W total battery capacity Lamp Head Source • Choice of MR16 6V-5W • Choice of MR16 LED 6V-4W, with life expectancy 50,000+ hours • Lamp heads are fully adjustable with no tools required. Self-Diagnostics • Not Available Special Wording Panels • Not Available
DIMENSIONS
Approvals • Listed to UL 924 Standards • UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards
Dimensions are approximate and subject to change.
4-1/16” [10.32 cm]
Warranty • Three-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) WG6-L
Wire Guard (Wall mount)
POWER CONSUMPTION CHART
12-7/8” [32.70 cm]
120/277VAC, 60Hz 0.11/0.05A
ORDERING FORMAT SERIES UQLXN500
LEGEND COLOR R= Red G= Green
LAMP TYPE -2MRSN= 6V-5W Halogen MR16 -2LD1N= 6V-4W LED MR16
11-3/4” [29.85 cm]
EXAMPLE: UQLXN500R-2MRSN
www.lightalarms.com
35
QUICK UQLXN-2SQ & UQLXN-0R-ID COMBINATION AND REMOTE CAPACITY SERIES TM
Thermoplastic Combination Units and Remote Capacity Exit Sign
FEATURES
SPECIFICATIONS
Construction • Frame, faceplate, backplate and canopy are made of Thermoplastic • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® UQLXN-2SQ, -2SQR, -2SQR-ID, -0R-ID Combination or Remote Capacity Exit Sign Series. The combination models and remote capacity Exit Sign specified include (2) faceplates, (1) backplate and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of injection-molded Thermoplastic. Frame, backplate and canopy shall be matching in color mist-white. Faceplate shall be mist-white, with a (R) red or (G) green legend. Snap together design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable snap-in/out chevron indicators. The combination model shall be suitable for surface mount, wall or ceiling installations. The EXIT illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. When specified, the Combination model shall be equipped with two square emergency heads with 6V-5.4W incandescent lamps that can be top or side mounted, adjusted, and aimed with no tools required. Combination models and remote capacity Exit Sign shall be 120/277VAC, 60Hz, and supplied with a sealed maintenance-free Lead-Calcium battery, providing at least 90 minutes, illumination upon AC failure. -2SQ model: shall include, (2) attached 6V-5.4W incandescent wedge-based lamp heads and offer no extra remote battery capacity with a power consumption of 0.11/.05A. -2SQR model: shall include, (2) attached 6V-5.4W incandescent wedge-based lamp heads and offer 12 watts extra remote battery capacity with power consumption of 0.11/.05A. -2SQR-ID model: shall include, (2) attached 6V-5.4W incandescent wedge-based lamp heads and offer 12 watts extra remote battery capacity with self-diagnostic option and have power consumption of 0.11/.05A. -0R-ID model: shall include no attached heads and offer 22W extra remote battery capacity with power consumption of 0.11/.05A. When specified, the Combination models and remote capacity Exit Sign with Improved Diagnostics (-ID) shall include a self-test and silent diagnostic function managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected, the pilot light shall change color from green to red and flash with a specific code. The red light is steady-on in case of a battery disconnect; it will flash with one blink for battery failure; two blinks for charger failure and four blinks for LED lamp failure. A label with the diagnostic legend shall be visible next to the pilot light. The combination models and remote capacity Exit Sign shall be tested by Underwriters Laboratories, listed to UL 924 standardsand UL listed for Damp location (50°F to 104°F, 10°C to 40°C). The combination models and remote capacity Exit Sign shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a three-year full warranty. The combination model or remote capacity Exit Sign unit shall be Lightalarms® Model ________________.
Mounting • Surface Mount • Universal model includes (2) faceplates, (1) backplate and (1) canopy • Canopy included for ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box used in wall mount applications Finishes • Finished in mist-white Chevrons: • Faceplate includes two field-selectable, snap-in/out chevron indicators Exit Legend LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Remote Capacity/Combination Units • -2SQR models feature a 6V Lead-Calcium extra capacity battery with 2 heads attached, plus an additional 12W of remote battery capacity • -0R-ID models feature a 6V Lead-Calcium extra capacity battery with no heads attached, self-diagnostics, and an additional 22W of remote battery capacity Lamp Head Source • 6V 5.4W wedge base incandescent lamp • Lamp heads are fully adjustable to top or side with no tools required. Self-Diagnostics • Combination models available with or without Improved Diagnostics • Remote Capacity Exit Sign includes Improved Diagnostics Special Wording Panels • Not Available Approvals • Listed to UL 924 Standards • UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards Warranty • Three-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Wire Guard (heads in any position) Wall Mount
WG10-L
POWER CONSUMPTION CHART 120/277VAC, 60Hz maximum 0.11/0.05A
36
www.lightalarms.com
TYPE
Combination unit with tool-less field-adjustable heads to accommodate top mount requirements or a no-head version for maximum remote capacity abilities
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. Remote Capacity Unit
Combination Unit
Shown with no mounted heads (UQLXN500R 0R-ID model)
Includes (2) heads only, dimension shown for top mount or side mount applications
Canopy
(Models ending with suffix -2SQ, -2SQR and -2SQR-ID) 16-1/8” [33.02 cm]
6-5/16” [16.04 cm]
13” [76.2 cm] 4-5/8” [11.75 cm]
15-5/8” [25.72 cm]
10-1/8” [25.71 cm]
5-7/8” [14.93 cm]
1” [2.54 cm] 21-5/8” [55.25 cm]
2-9/16” [6.50 cm]
10-1/8” 10-1/8” [37.15 [37.15 cm]cm]
ORDERING FORMAT SERIES UQLXN500
LEGEND COLOR R= Red G= Green
LAMP TYPE/CAPACITY -2SQ= (2) 6V-5.4W heads, no remote capacity (red or green legend) -2SQR= (2) 6V-5.4W heads, 6V-12W remote capacity (red or green legend) -2SQR-ID= (2) 6V-5.4W heads, 6V-12W remote capacity, improved-diagnostic (red legend only) -0R-ID= No heads, 6V-22W remote capacity, improved-diagnostic (red legend only)1
1
Not compatible with LED remotes
EXAMPLE: UQLXN500R2SQR
www.lightalarms.com
37
CLUSTER™ LED UQLXN500-2LED COMBO & ELF652D SERIES Thermoplastic LED Combination Unit
FEATURES
SPECIFICATIONS
Housing • Frame, faceplate, backplate and canopy are made of thermoplastic • 6 inch EXIT lettering legend, available in Red or Green • Lamp heads are fully adjustable with no tools required
Supply and Install Lightalarms® Cluster™ UQLXN500-2LED Series.
Mounting • Surface Mount • Model includes (2) faceplate, (1) backplate and (1) canopy • Canopy included for ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications Finishes • Finished in Mist-White Chevrons • Faceplate includes two field-selectable, snap-in/out chevron indicators Exit Legend LEDS • Red or Green Long-Life Light Emitting Diodes (LED) illumination
The combination model specified includes (2) faceplate, (1) backplate and (1) canopy. The frame, faceplate, backplate and canopy shall be constructed of inject-molded thermoplastic. Frame, backplate and canopy shall be mist-white. Faceplate shall be mist-white with a (R) red or (G) green legend. Push-to-snap design, allows for no screws being necessary to hold the faceplate(s) or backplate together. The faceplate shall come standard with two field-selectable, removable snap-in/out chevron indicators. The combination model shall be suitable for surface mount, wall or ceiling installations. The EXIT illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. Combination model shall be equipped with two white Cluster™ LED glarefree heads with tool-less, adjustable abilities. Combination models shall be 120/277VAC, 60Hz, with a 3.6V power consumption of .1/.05A and supplied with a sealed maintenance-free Nickel-Metal Hydride battery, providing at least 90 minutes illumination upon AC failure.
Combination units • 3.6V Nickel-Metal Hydride battery Lamp Head Source • White LED 3.6V-4W, with life expectancy 50,000+ hours
The Combination unit shall be tested by the Underwriting Laboratories and listed to UL 924 standards. As well as Evaluated to UL 924 standard (68°F to 86°F, 20°C to 30°C) and meets NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a Three-year full warranty.
Self-Diagnostics • Available Special Wording Panels • Not Available
The equipment shall be Lightalarms® Model:
Approvals • Listed to UL 924 Standards • UL listed for Damp location (68°F to 86°F, 20°C to 30°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC and OSHA illumination standards Warranty • Three-year full warranty (subject to proper installation and maintenance) • 3.6V Nickel-Cadmium battery, three-year full, three-year pro-rata warranty
POWER CONSUMPTION CHART SERIES
CURRENT (A) / POWER (W) 120VAC, 60Hz
277VAC, 60Hz
UQLXN500R-2LEDR
0.044/3.56
0.037/4.06
UQLXN500G-2LEDR
0.042/3.2
0.036/3.8
38
www.lightalarms.com
.
TYPE
The Cluster™ LED Family features a Combination unit which includes extra battery capacity to power the Cluster™ LED ELF652D remote head or allow for extended run time.
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change.
4-1/4” [10.16cm]
11-5/8” [27.94cm]
2” [5.08cm]
7-1/4” [17.78cm]
8-1/4” [20.32cm]
17-7/8” [43.18cm]
ORDERING FORMAT SERIES
LEGEND COLOR
UQLXN500
R= Red G= Green
LAMP
CAPACITY
-2LED= Cluster™ LED head style
Blank= No option R= Remote capacity RID= Remote capacity & Improved diagnostics Note: Remote capacity can ONLY be used to power the Cluster™ LED ELF652D/LED Remote Head or to extend the combo’s emergency run time beyond the standard 90 minutes.
Example: UQLXN500R-2LEDR
CLUSTER™ LED ELF652D REMOTE HEAD The Cluster™ LED ELF652D/LED Remote head can ONLY be powered from the UQLXN-2LED combo or LCA 2LED battery units of the same family. Used for internal or external applications, the indoor remote head draws 3.6V-3.6W and Weather-Proof head draws 3.6V-3.8W.
DIMENSIONS
Dimensions are approximate and subject to change. Indoor Remote
Weatherproof Remote
Weatherproof Remote 2-1/16” [5.08cm] 2-1/16” [5.24cm]
7-6/16” [18.74cm] 5-10/16” [14.3cm]
4-11/16” 4-11/16” [11.91cm] [10.16cm]
Indoor Remote 6-11/16” [16.99cm] [15.24cm] 6-11/16”
ORDERING FORMAT SERIES ELF652
# OF HEADS D= Double Head
LAMP /LED= Cluster™ LED head style
OPTION Blank= Indoor Use Only -WP= Weather-Proof
Example: ELF652D/LED
www.lightalarms.com
39
SEVERE
TM
XV & XVE SERIES
Nema 4X, Vandal Resistant and Harsh Environment Exit Sign
FEATURES
SPECIFICATIONS
Construction • Nema-4X certified for wall or ceiling mount • Frame: Polyvinyl Chloride enclosure, fully gasketed around the lens, backplate and canopy to prevent water infiltration • Faceplate: heavy-duty, vandal-resistant polycarbonate • Backplate: heavy duty 1/8 inch thick aluminum • Canopy: die-cast aluminum • Stainless steel tamper-proof screws • Magnetically operated test switch • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Severe™ XV, XVE Series. The Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy and specified as double face shall be standard with (2) faceplates and (1) canopy. Frame shall be fabricated of a Polyvinyl Chloride enclosure with full gasket around the lens, backplate and canopy. Faceplate lens shall be heavy-duty, vandal-resistant polycarbonate. Backplate shall be heavy duty 1/8 inch thick aluminum. Canopy shall be constructed of die-cast aluminum. Shall include a magnetically operated test switch. 6 inch EXIT lettering legend, available in Red or Green. Frame, backplate and canopy shall be matching in color, (W) white (B) black or (G) gray. Faceplate shall be (W) white, (B) black, (G) gray or optional (A) brushed aluminum with a (R) red or (G) green legend. Stainless steel tamper-proof screws hold the faceplate(s) or backplate to the frame. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120-277VAC, 50/60Hz, universal, 2-wire input 120/277VAC, 50/60Hz. AC/DC models shall be 120/277VAC, 50/60Hz, universal, 2-wire input. 120/277VAC, 50/60Hz and allows for DC operation from 6VDC to 48VDC with a DC draw of less than 1.5W. Self-Powered models shall be 120-277VAC, 60Hz, (with a power consumption of 3.7) and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes, illumination upon AC failure. Self-Powered Exit Sign standard with Improved Diagnostics shall include a self-test and choice of silent or audible diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected, the single service required indicator illuminates immediately. A detailed diagnostic display is located on the inside of the Exit Sign, out of sight from the general public. The detailed diagnostic display inside the Exit Sign will further indicate the nature of the fault. The Exit Sign shall be tested by Underwriters Laboratories, listed to UL 924 standards, and UL listed for Damp location (50°F to 104°F, 10°C to 40°C) and meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back-plate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications • Frame includes ½ inch conduit knock-out entry on top and sides. Finishes • Choice of finishes: white, black or gray • Optional brushed aluminum faceplate stencil available Chevrons: • Faceplate includes two field-selectable, knock-out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Self-Powered models standard with Improved Diagnostics • NEXUS® Wired or Wireless system compatible Special Wording Panels: • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards Damp location 50°F to 104°F (10°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards • NEMA-4X 25°F -4°F (-4°C or -20°C)* • Standard products AC-Only and AC/DC -40°F to 104°F (-40°C to 40°C ); Optional: Cold Weather Self-Powered -4°F to 77°F (-20°C to 25°C) • NSF Rated for food processing areas *Available in wall or ceiling mount only
Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Convert single face to double face, red (in the field) Convert single face to double face, green (in the field) Tamper-Proof Bit (extra) *Specify White (WT) or Black (BK) housing
40
DFKR-* DFKG-* 690.0454-L
POWER CONSUMPTION CHART MODEL
AC SPECS
DC SPECS
AC-Only
120-277VAC, 50/60Hz
1.2W
–
–
AC/DC
120/277VAC, 50/60Hz
1.2W
6 to 48VDC
Less than 1.5W
Self-Powered
120-277VAC, 50/60Hz
3.7W
Ni-Cd battery
Min. 90 minutes
www.lightalarms.com
NEMA-4X TYPE
Designed specifically for NEMA-4X and harsh environments such as transit platforms, parking garages, schools, wet and cold locations or locations prone to vandalism
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 4-5/8” [11.75 cm]
9-3/16” [23.34 cm]
3/4” [1.905 cm]
6-1/4” [15.87 cm]
3-7/8” [9.85 cm]
13-1/4” [33.65 cm]
3-7/16” [8.74 cm]
Single face
Double face
ORDERING FORMAT HOUSING/FACE COLOR Blank= Black/Black BW= Black/White BA= Black/Aluminum GB= Gray/Black GW= Gray/White GA= Gray/Aluminum WB= White/Black WW= White/White WA= White/Aluminum
SERIES XV= AC-only XVE= Self-Powered Nickel-Cadmium battery
FACES
LEGEND COLOR
-1= Single face -2= Double face
-R= Red -G= Green
DIAGNOSTICS
HOUSING
OPTIONS
Blank= AC-Only Models -D= Improved Diagnostic (non-audible, standard)1 -NEX= Nexus® Wired1, -NEXRF= Nexus® Wireless1
-4X= N EMA-4X housing
Blank= No options -2= Dual Circuit (120/120 or 277/277AC only)1 -DC= AC/DC 6V to 48VDC1 -1= Flasher only1 -F= Fire alarm activated flasher1 -FB= Flasher/buzzer (Self-Powered only)1 -CW= Cold weather (Self-Powered -4°F to 77°F, -20°C to 25°C) (AC-Only and AC/DC -40°F to 77°F, -40°C to 25°C) -Y= Open face/special wording -CM= Canopy pendant mount
1 Available
with Self-Powered models
only.
1 Not
available with -NEX or -NEXRF, Nexus® option.
EXAMPLE: BAXVE-1-R-D-4X-CW
SEVERE™ NEMA-4X RATED AND NSF CERTIFIED FAMILY The Severe™ XV Series Exit Sign is a part of the Severe™ family of NEMA-4X rated emergency lighting products. The Severe™ family offers complete emergency lighting solutions for commercial and industrial environments where protection against humidity, dust, water infiltration and the risk of vandalism are specification criteria. These products deliver state-of-the-art illumination in a visually appealing package.
Severe™ XV Combination Series p.42
Severe™ V Battery Series p.90 www.lightalarms.com
Severe™ ELF650 Remote Series p.111 41
SEVERE XV12E & XV24E COMBINATION SERIES TM
Nema 4X, Vandal Resistant and Harsh Environment Combination Unit
FEATURES
SPECIFICATIONS
Construction • Frame: Polyvinyl Chloride enclosure, fully gasketed around the lens, backplate and canopy to prevent water infiltration • Faceplate: heavy-duty, vandal-resistant polycarbonate • Backplate: heavy-duty 1/8 inch thick aluminum • Canopy: constructed of die-cast aluminum • Heads protected by a shock-absorbent, clear polycarbonate lens • Stainless steel tamper-proof screws • Magnetically operated test switch • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Severe™ XV12E, XV24E Combination Series. The combination model specified as single face shall be standard with (1) faceplate, (1) backplate and (1) canopy and specified as double face shall be standard with (2) faceplates and (1) canopy. Frame shall be fabricated of a Polyvinyl Chloride enclosure with full gasket around the lens, backplate and canopy. Faceplate lens shall be heavy-duty, vandal-resistant polycarbonate. Backplate shall be heavy-duty 1/8 inch thick aluminum. Canopy shall be constructed of die-cast aluminum. Lamp heads shall be protected by a clear polycarbonate lens. Model shall include a magnetically operated test switch, with 6 inch EXIT lettering legend, available in Red or Green. Frame, backplate and canopy shall be matching in color, (W) white (B) black or (G) gray. Faceplate shall be (W) white, (B) black, (G) gray or optional (A) brushed aluminum with a (R) red or (G) green legend. Stainless steel tamper-proof screws hold the faceplate(s) or backplate to the frame. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. When specified the unit shall be equipped with two emergency heads protected by shock-absorbent, clear polycarbonate covers with tool-less adjustable swivels and MR16 halogen lamps or MR16 LED lamps as noted. Combination Units shall be 120/277VAC, 50/60Hz, and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. XV12E model shall be 6V-12W with power consumption of 0.12/0.06A, less than 13W. XV24E model shall be 12V-24W with power consumption of 0.17/.08A, less than 19W. XV12E1 model with cold weather option shall be a 6V-12W with power consumption of 0.24/0.24A, less than 25W. Combination Units standard with Improved Diagnostics shall include a self-test and choice of silent or audible diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module, lamps and LED strip failure. When a fault is detected, the single service required indicator illuminates immediately. A detailed diagnostic display is located on the inside of the Combination Unit, out of sight from the general public. The detailed diagnostic display inside the unit will further indicate the nature of the fault. The Combination Unit shall be tested by Underwriters Laboratories, listed to UL 924 standards, UL listed for Damp location (50°F to 104°F, 10°C to 40°C) and UL listed for Cold Weather option (-40°F to 77°F, -40°C to 25°C). The Combination Unit shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Combination Unit shall be Lightalarms® Model ____________________.
Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back-plate and (1) canopy • Double face model includes (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications • Backplate features universal knockouts for a standard 4 inch junction box, used in wall mount applications • Frame includes ½ inch conduit knock-out entry on top and sides. Finishes • Choice of finishes: white, black or gray • Optional brushed aluminum faceplate stencil available Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators Exit Legend LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Combination Units • XV12E Model, Nickel-Cadmium battery, 6V-12W total battery capacity • XV24E Model, Nickel-Cadmium battery, 12V-24W total battery capacity (available remote capacity of 16W when using 12V-4W MR16 LED lamps) Lamp Head Source • Choice of MR16 halogen, 6V-6W, 12V-10W or 12V-12W • Choice of MR16 LED, 6V or 12V-4W, 12V-5W or 12V-6W with life expectancy 50,000+ hours • Lamp heads are fully adjustable with no tools required. Self-Diagnostics • Units standard with Improved Diagnostics • NEXUS® Wired or Wireless system compatible Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • Listed to UL 924 Standards • UL listed for Damp location (50°F to 104°F, 10°C to 40°C) • UL listed for Cold Weather option (-40°F to 104°F, -40°C to 40°C) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC, OSHA illumination standards • NSF Rated for food processing areas Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Tamper-Proof Bit (Extra)
42
www.lightalarms.com
690.0454-L
AVAILABLE WITH LED LAMP HEADS
!
NEW
NEMA-4X
TYPE
Designed and engineered for the toughest environments, this Combination Unit is suitable for industrial and commercial applications and public facilities
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change.
9-3/16” [23.34 cm]
12-5/8” [32.07 cm]
4-5/8” [11.75 cm]
3/4” [1.905 cm]
6-1/4” [15.87 cm]
13-1/4” [33.65 cm]
3-7/8” [9.85 cm]
3-7/16” [8.74 cm]
Double face
Single face
POWER CONSUMPTION/UNIT RATING CHART SERIES
AC SPECS AC Input
XV12E
120/277VAC, 50/60Hz
XV24E Models with CW4 Option
DC SPECS - WATTS TO 87.5% OF RATED BATTERY VOLTAGE*
Current Draw
Voltage
0.12/0.06A - Less than 13W
6V
0.17/0.08A - Less than 19W
12V
Battery Nickel-Cadmium
1-1/2 hrs.
2 hrs.
3 hrs.
4 hrs.
12
9
-
-
24
18
12
9
0.24/0.12A - Less than 25W *National Electrical Code Specification
ORDERING FORMAT HOUSING/ FACE COLOR
SERIES/ CAPACITY
FACES
Blank= Black/Black BW= Black/White BA= Black/ Aluminum WW= White/White WB= White/Black WA= White/ Aluminum GA= Gray/Aluminum GW= Gray/White GB= Gray/Black
XV12E= 6V-12W XV24E= 12V-24W
1= Single face 2= Double face
LEGEND COLOR R= Red G= Green
DIAGNOSTICS D= Improved Diagnostics (non-audible standard) DA= Improved Diagnostics (audible) NEX= NEXUS® Wired 1 NEXRF= NEXUS® Wireless 1
HOUSING
# OF HEADS
4X= Nema 4X housing
/0= 0 head1 /0N= 0 head2 /2= Two heads
1A 1 CSA
US Approved only, consult your sales representative
remote load must be connected 2 With no remote load connected
LAMP TYPE MR16 Halogen M6= 6V-6W M10=12V-10W M12 = 12V-12W MR16 LED LD1= 6V-4W LD7= 12V-4W LD9=12V-5W LD10=12V-6W
OPTIONS -FAF= Flasher (fire alarm activated) -FB= F lasher/buzzer (AC power failure)1 -FL= Flasher (AC power failure)1 -208V= 208VAC, 60Hz input -240V= 240VAC, 60Hz input -208V50HZ= 208VAC, 50Hz input -CW4= Cold weather 120/277V (-40°F/-40°C) 2 -CM= Canopy Pendant Mount 1 Not available with “D 2 Single face only
or DA” option
EXAMPLE : WWXV12E1RDA4X/2M6CW4
SEVERE™ NEMA-4X RATED AND NSF CERTIFIED FAMILY The Severe™ XV Series Combination Units is a part of the Severe™ family of NEMA-4X rated emergency lighting products. The Severe™ family offers complete emergency lighting solutions for commercial and industrial environments where humidity, dust, water infiltration and the risk of vandalism are specification criteria. These products deliver state-of-the-art illumination in a visually appealing package.
Severe™ XV Exit Series p.40
Severe™ V Battery Series p.90 www.lightalarms.com
Severe™ ELF650 Remote Series p.111 43
SEVERE
TM
XVHZ & XVEHZ SERIES
Class I Division 2, Groups A, B, C and D, Hazardous Location Exit Sign
FEATURES
SPECIFICATIONS
Construction • Frame: Polyvinyl Chloride enclosure, fully gasketed around the lens, backplate and canopy to prevent water infiltration • Faceplate: heavy-duty, vandal-resistant polycarbonate • Backplate: heavy-duty 1/8 inch thick aluminum • Junction Box: industrial-grade, made of die-cast aluminum • Stainless steel tamper-proof screws (tamper-proof bit proved) • Magnetically operated test switch • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Severe™ XVHZ, XVEHZ Series. The Exit Sign specified as single face shall be standard with (1) faceplate, (1) backplate and (1) junction box and specified as double face shall be standard with (2) faceplates and (1) junction box. Frame shall be fabricated of a Polyvinyl Chloride enclosure with full gasket around the lens, backplate and junction box. Faceplate lens shall be heavy-duty, vandal-resistant polycarbonate. Backplate shall be heavy-duty 1/8 inch thick aluminum. Canopy shall be constructed of die-cast aluminum. Shall include ½ inch electrical conduit entry on both sides and top of frame, a magnetically operated test switch and 6 inch EXIT lettering legend, available in Red or Green. Frame, backplate and junction box shall be matching in color, (G) Gray. Faceplate shall be (G) gray with a (R) red or (G) green legend. Stainless steel tamper-proof screws hold the faceplate(s) or backplate to the frame. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Exit Sign shall be suitable for surface mount, wall, end or ceiling installations. The double face Exit Sign shall be suitable for surface mount, end or ceiling installations. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. AC-Only models shall be 120/277VAC, 50/60Hz, with a power consumption of less than 2W. Self-Powered models shall be 120/277VAC, 50/60Hz, with a power consumption of less than 2.5W and supplied with a sealed maintenance-free Nickel-Cadmium battery, providing at least 90 minutes illumination upon AC failure. Self-Powered Exit Sign standard with Improved Diagnostics shall include a selftest and silent diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module and LED lamps. When a fault is detected the single service required indicator illuminates immediately. A detailed diagnostic. display is located on the inside of the Exit Sign, out of sight from the general public. The detailed diagnostic display inside the Exit Sign will further indicate the nature of the fault. The Exit Sign shall be tested by CSA-US Listed for Hazardous Locations, evaluated to UL844 standard for Class I Division 2, Groups A, B, C and D evaluated to UL924 and UL1598 standards, have a temperature code rating of T6 (maximum 85°C 185°F, shall be suitable for cold weather: -20°C (Self-Powered model with CW option) and -40°C (AC -only model) and shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Exit Sign shall be Lightalarms® Model _________________________.
Mounting • Surface Mount • Single face model includes (1) faceplate, (1) back-plate and (1) junction box • Double face model includes (2) faceplates and (1) junction box • Junction box included for wall, end or ceiling mount applications • Frame includes ½ inch conduit knock-out entry on top and sides. Finishes • Finished in industrial gray Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Self-Diagnostics • Self-Powered models available standard with Improved Diagnostics • NEXUS® Wired or Wireless system compatible Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • CSA-US Listed for Hazardous Locations • Evaluated to UL844 standard for Class I Division 2, Groups A, B, C and D • Evaluated to UL924 and UL1598 standard • Temperature Code: T6 (maximum 85°C, 185°F) • Suitable for cold weather: -4°F (-20°C) (Self-Powered model with CW option) and -40°F (-40°C) (AC-only model) • Meets NFPA101 (Life Safety Code), NFPA 70 NEC & OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Tamper-Proof Bit (Extra)
690.0454-L
POWER CONSUMPTION CHART MODEL
AC SPECS
DC SPECS
AC-Only Red
120/277VAC, 50/60Hz
Less than 2W
–
–
AC-Only Green
120/277VAC, 50/60Hz
Less than 1.5W
–
–
Self-Powered Red
120/277VAC, 50/60Hz
Less than 2W
Nickel-Cadmium battery
Minimum of 90 minutes
Self-Powered Green
120/277VAC, 50/60Hz
Less than 2.5W
Nickel-Cadmium battery
Minimum of 90 minutes
44
www.lightalarms.com
TYPE
Ideally suited for areas with the potential for flammable gases, vapors or liquids to create an explosive atmosphere
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 4-3/8” [11.11cm]
Double face
2-1/4” [5.715 cm]
4-3/8” [11.12 cm]
9-1/4” [23.49 cm]
13-1/4” [33.65 cm]
3-1/2” [8.89 cm]
3-7/8” [8.89 cm]
ORDERING FORMAT HOUSING/FACE COLOR GG= Gray/Gray
SERIES XVHZ= AC-Only XVEHZ= Self-Powered
FACES 1= S ingle Face 2= D ouble Face
LEGEND COLOR R= Red G= Green
DIAGNOSTIC Blank= AC-Only Models -D= Improved Diagnostic (included standard non audible)1 -NEX= N exus® Wired1,2 -NEXRF= Nexus® Wireless1,2
OPTIONS CW= Cold weather (Self-Powered -13°F, -20°C) (AC-only -40°F, -40°C)
1 Available
with Self-Powered models only. Consult your sales representative
2
EXAMPLE : GGXVEHZ2R-DCW
SEVERE™ CLASS 1, DIVISION 2 FAMILY The Severe™ XVHZ & XVEHZ Exit Sign is part of the Severe™ family of Class I Division 2 rated emergency lighting products. Extremely resistant to water, strong impacts, vibrations and variations in temperature, this family of products is ideally suited for areas with the risk of the presence of flammable gases, or vapors or liquids able to create an explosive gas atmosphere.
Severe™ XVH Combo Series p.46
Severe™ VH Battery Series p.92
www.lightalarms.com
Severe™ ELF 651 Remote Series p.113
45
SEVERE XVH, XVH12N & XVH12H COMBINATION SERIES TM
Class I Division 2, Groups A, B, C and D Hazardous Location Combination Unit
FEATURES
SPECIFICATIONS
Construction • Frame: fabricated of a Polyvinyl Chloride enclosure, fully gasketed around the lens and backplate to prevent water infiltration • Faceplate: heavy-duty, vandal-resistant polycarbonate • Backplate: heavy-duty 1/8 inch thick aluminum • Heads protected by shock-absorbent, clear polycarbonate covers • Stainless steel tamper-proof screws • Magnetically operated test switch • 6 inch EXIT lettering legend, available in Red or Green
Supply and Install Lightalarms® Severe™ XVH, XVH12N, XVH12H Combination Series. The combination model specified as single face shall be standard with (1) faceplate, and (1) backplate. Frame shall be fabricated of a Polyvinyl Chloride enclosure with full gasket around the lens and backplate. Faceplate lens shall be heavy-duty, vandal-resistant polycarbonate. Backplate shall be heavy duty 1/8 inch thick aluminum with 4 mounting eyelets. Lamp heads shall be protected by a clear polycarbonate lens. Model shall include stainless steel tamper-resistant screws, tamper-proof bit, magnetically operated test switch, and 6 inch EXIT lettering legend, available in Red or Green. Frame, and backplate shall be matching in color, industrial (G) Gray. Faceplate shall be industrial (G) gray with a (R) red or (G) green legend. Stainless steel tamper-proof screws hold the faceplate(s) or backplate to the frame. The faceplate shall come standard with two field-selectable, removable knockout chevron indicators. The single face Combination unit shall be suitable for surface wall mount installations only. The illumination source shall be Light Emitting Diodes (LED) in (R) red or (G) green color. The LEDs shall provide illumination in normal and emergency operation mode. The LEDs shall be mounted inside the Exit Sign housing. A color matching LED sensitive legend diffuser of (R) red or (G) green, shall be mounted in front of the LEDs to provide the 6” high by ¾” stroke EXIT letters with even illumination and no visible LEDs or hot spots. When specified, the unit shall be equipped with two emergency heads protected by shock-absorbent, clear polycarbonate covers with tool-less adjustable swivels and MR16 halogen lamps as noted. Combination Units shall be 120/277VAC, 50/60Hz, and supplied with a sealed maintenance-free battery, providing at least 90 minutes illumination upon AC failure. XVH model shall be Nickel-Cadmium battery 6V-20W with power consumption of .15/.07A, less than 16W. XVH12N model shall be a Nickel-Cadmium battery 12V-24W with power consumption of .30/.08A, less than 29W. XVH12H model shall be a Nickel-Metal Hydride battery 12V-40W with power consumption of .30/.08A, less than 29W. Combination Units standard with Improved Diagnostics shall include a self-test and choice of silent or audible diagnostic function, managed by a micro-controller; it shall execute automatic tests for one minute every 30 days, 30 minutes every 60 days and 90 minutes annually. A diagnostic circuit shall continuously monitor the performance of the battery, charger module, lamps and LED strip failure. When a fault is detected, the single service required indicator illuminates immediately. A detailed diagnostic display is located on the inside of the Combination Unit, out of sight from the general public. The detailed diagnostic display inside the unit will further indicate the nature of the fault. The Combination Unit shall be tested by CSA US Listed for Hazardous Locations, evaluated to UL844 standard for Class I Division 2, Groups A, B, C and D, evaluated to UL924 and UL1598 standards, Temperature Code: 6V 10W MR16 lamp, T3C (max 320°F, 160°C); 12V 12W MR16 lamp, T3A (max 356°F, 180°C); 12V 20W MR16 lamp, T2D (max 419°F, 215°C). The Combination Unit shall meet NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards. Includes a five-year full warranty. The Combination Unit shall be Lightalarms® Model _________________.
Mounting • Surface Wall Mount ONLY • Single face model includes (1) faceplate and (1) back-plate • Backplate features universal knockouts for a standard 4 inch junction box, and four mounting eyelets used in wall mount applications • Frame includes ½ inch conduit knock-out entry on top and sides. Finishes • Finished in industrial gray Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators Exit Legend LEDs • Red or Green Long-Life Light Emitting Diodes (LED) illumination Combination Units • XVH Model, Nickel-Cadmium battery, 6V-20W total battery capacity • XV12N Model, Nickel-Cadmium battery, 12V-24W total battery capacity • XV12H Model, Nickel-Metal Hydride battery, 12V-40W total battery capacity Lamp Head Source • Choice of MR16, 6V 10W or 12V up to 20W • Choice of MR16 LED, 6V or 12V-4W or 12V-5W each lamps • Lamp heads are fully adjustable with no tools required. Self-Diagnostics • Combination Units standard with Improved Diagnostics • NEXUS® Wired or Wireless system compatible Special Wording Panels • Available. Contact your sales representative with your design requirements Approvals • CSA US Listed for Hazardous Locations • Evaluated to UL844 standard for Class I Division 2, Groups A, B, C and D • Evaluated to UL924 and UL1598 standard • Temperature Code: 6V-10W MR16 lamp, T3C (max 320°F, 160°C) • Temperature Code: 12V-12W MR16 lamp, T3A (max 356°F, 180°C) • Temperature Code: 12V-20W MR16 lamp, T2D (max 419°F, 215°C) • Temperature Code: All LED lamps, T4A (max 248°F, 120°C) • Meets NFPA101 (Life Safety Code), NFPA 70-NEC and OSHA illumination standards Warranty • Five-Year full warranty (subject to proper installation and maintenance)
ACCESSORIES
(Order as a separate item) Tamper-Proof Bit (extra)
46
690.0454-L
www.lightalarms.com
TYPE
Designed for installations in Hazardous Locations with the risk of presence of flammable gases, vapors or explosive liquids
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 3-1/2” [8.89 cm]
6-1/4” [15.87 cm]
12-5/8” [32.07 cm]
14-1/2” [58.1 cm] 13-3/4” [56.75 cm]
TEMPERATURE CODES LAMP RATING
TEMPERATURE CODE
MAX. TEMPERATURE
REPLACEMENT LAMP PART #
6V-10W
T3C
320oF (160oC)
580.0079
12V-12W
T3A
356oF (180oC)
580.0080
12V-20W
T2D
419oF (215oC)
580.0068
6V-4W LED
T4A
248oF (120oC)
580.0097
12V-4W LED
T4A
248oF (120oC)
580.0093
12V-5W LED
T4A
248oF (120oC)
580.0104 Note: Use qualified replacement lamps to avoid risk of over-heating
POWER CONSUMPTION/UNIT RATING CHART SERIES
AC INPUT
MAXIMUM
(VAC)
Current (Amp)
STAND-BY
Power (Watt)
Current (Amp)
WATTS TO 87.5% OF RATED BATTERY VOLTAGE*
Power (Watt)
1-1/2 hrs
2 hrs
3 hrs
4 hrs
XVH
120/277VAC, 50/60Hz
0.15 / 0.07
16
0.09 / 0.03
8
20
15
–
–
XVH12N
120/277VAC, 50/60Hz
0.30 / 0.08
29
0.13 / 0.05
10
24
18
12
–
XVH12H
120/277VAC, 50/60Hz
0.30 / 0.08
29
0.13 / 0.05
10
40
30
20
12
*National Electrical Code Specification
ORDERING FORMAT HOUSING/FACE COLOR GG= Gray/Gray
SERIES Nickel-Cadmium battery XVH= 6V-20W XVH12N= 12V-24W
LEGEND COLOR R= Red G= Green
Nickel-Metal Hydride battery XVH12H= 12V-40W
DIAGNOSTIC -D= Improved Diagnostic (included standard – non-audible) -DA= Improved Diagnostic (audible) -NEX= Nexus® Wired1 -NEXRF= Nexus® Wireless1 1
Consult your sales representative
NO. OF HEADS /0= No /2= 2 heads
head1
1 A
remote load must be connected
LAMP TYPE1 M10= 6V-10W MR16 M12= 12V-12W MR16 MH20= 1 2V-20W MR16, High output LD1= 6V-4W MR16, LED LD7= 12V-4W MR16, LED LD9= 12V-5W MR16, LED 1 No
other lamp option available.
EXAMPLE: GGXVHRD/2M10
SEVERE™ CLASS 1, DIVISION 2 FAMILY The Severe™ XVHZ & XVEHZ Exit Sign is part of the Severe™ family of Class I Division 2 rated emergency lighting products exit sign and remote are extremely resistant to water, strong impacts, vibrations and variations in temperature, this family of products is ideally suited for areas with the risk of the presence of flammable gases, or vapors or liquids able to create an explosive gas atmosphere.
Severe™ XVHZ & XVEHZ Exit Series p.44
Severe™ VH Battery Series p.92 www.lightalarms.com
Severe™ ELF 651 Remote Series p.113 47
X402C= Ceiling Mount X402W= Wall Bracket Mount X402P= Pendant Mount
X402 AC-ONLY, AC/DC & SELF-POWERED EXIT SIGN & COMBINATION UNITS Class I, Division 1 & 2, Groups C and D Class II, Division 1 & 2, Groups E, F and G
FEATURES
SPECIFICATIONS
Construction • EXP Housing: Hazardous Location, heavy gauge copper-free case aluminum • Spin-off gasketed cover prevents propagation of internally generated arcs • Stainless steel vent/drain • Circuit board: silicone conformal coated • Sealed test switch • X402 Exit and Lamp Head fixture: heavy cast aluminum with pyrex lens • Exit Faceplate: heavy-duty 20 gauge steel, baked enamel grey finish • 6 inch EXIT lettering legend, available in Red or Green Mounting • X402 AC-Only, AC/DC Exit Head, Surface Mount, ceiling, wall or pendant • EXP Self-Powered Exit Sign Surface Wall Mount Only • EXP Combination Unit Surface Wall Mount Only • Self-Powered and Combination Housing includes (4) mounting lugs on each corner and 3/4 inch NPT conduit knock-outs entry on top and bottom of housing • X402 & EXP single face model includes (1) faceplate • X402 Double face model includes (2) faceplates Finishes • Finished in industrial gray Chevrons • Faceplate includes two field-selectable, knock-out chevron indicators Approvals • Manufactured in accordance with UL844, UL1203, and UL924 • Rated for operation in Class I, Division 1 & 2, Groups C and D • Rated for operation in Class II, Division 1 & 2, Groups E, F and G • Complies with NEC, OSHA and NEMA for above Classes and Groups Warranty • Three-Year full warranty (subject to proper installation and maintenance) For Desired Model • AC-Only Exit: Order X402 Exit Sign to be powered by a separate AC power source during emergency operation • AC/DC Exit: Order X402 Exit Sign and a Transfer Switch Panel thus allowing for emergency operation to be supplied by a separate remote DC source • Self-Powered Exit: Order EXP6N or EXP12N with attached X402 Exit Sign • Combination Units: Order EXP6N or EXP12N, a E402 Light Head, and X402 Exit Sign Transfer Circuit (needed to be ordered separately with AC/DC Exit Signs) • A TS panel is required for AC/DC Hazardous Location X402 Exit Signs that are under constant operation as required by code. TS panels are not designed to be installed/mounted in a hazardous or explosive area. TS panels are to be mounted remotely from these areas types. • TS panel available for up to 6V= 50W, 12V= 100W, 24V= 100W To Order a TS Panel the following information is required: 1) AC Input. 120V and other voltages are available 2) DC voltage. 3) The total wattage load of all X402 lamp(s) to be supplied by TS Panel Electrical Specifications for the TS Panel Input AC voltage; 120V, 60Hz, 1 phase (other voltages available) Input DC voltage; 6, 12 or 24V (must select which applies) Input DC voltage must be identical to DC output voltage Wattage: TS Panel oversized 10-20% greater than total connected load. Matching Hazardous Location Family Battery Units p.94-95
Supply and Install Lightalarms® X402, EXP6N, EXP12N Hazardous Location Exit Sign & Combination Series. X402 AC-Only or AC/DC Exit Sign, housing shall be specified mounting (C) ceiling, (W) wall or (P) pendant, with single face including (1) faceplate, and (1) backplate, double face including (2) faceplates. Self-Powered Exit Sign housing is wall mount and single face only. Combination unit housing is wall mount and single face only plus (1) lamp head. Self-Powered and combination units use sealed NickelCadmium batteries EXP housing: shall be Hazardous Location, corrosion resistant, one-piece heavy gauge copper-free case aluminum, with spin-off gasketed cover prevents propagation of internally generated arcs into the hazardous atmosphere, stainless steel vent/drain and circuit board silicone conformal coated to protect against humidity. The Exit and Lamp Head fixture shall be heavy cast aluminum with pyrex lens. All shall be industrial gray color finish. Exit faceplate include two removable knockout chevron indicators and choice of (R) red or (G) green, legend with 6” by ¾” stroke letters.
48
The Exit Sign or combination unit shall be Lightalarms® Model ___________.
DIMENSIONS
Dimensions are approximate and subject to change. AC-Only and AC/DC Exit Signs
Ceiling Mount
Wall Mount
Pendant Mount
5-3/4” [14.6 cm] 6” [15.24 cm] 9-1/8” 23.17 cm]
16-7/8” [42.86 cm] 17-3/4” [45.08 cm]
12-3/8” [31.43 cm]
6” [15.24 cm]
34-1/8” [86.67 cm] 16-7/8” [42.86 cm]
12-3/8” [31.43 cm] 17” [43.18 cm]
23-3/4” [60.4 cm]
Self-Powered Exit Sign
23-3/4” [60.4 cm]
Combination Units
www.lightalarms.com
20-1/8” [51.0 cm]
23-3/8” [59.2 cm]
30-5/8” [77.8 cm]
TYPE
Designed to allow the safe operation of Exit Sign and Combination Unit batteries in a Class I, Division 1&2, Groups C&D, and a Class II, Division 1&2, Groups E, F & G explosive environments
CATALOG #
NOTES
E402 LIGHT HEAD (ONLY), LAMP SECTION CHART LAMP TYPE High Intensity Tungsten (HIT)
BI-PIN Halogen
VOLTAGE
LAMP WATTAGE
LAMP TYPE #
LAMP SUFFIX
6V
9W
135
L9
570.0010
6V
18W
1130
L18
570.0037
12V
9W
138
L9
12V
18W
139
12V
25W
6V
Combination Unit
UNIT CAPACITY CHART VOLTS
REPLACEMENT LAMP PART #
SERIES
WATTS TO 87.5% OF RATED BATTERY VOLTAGE* 1 1/2 hrs.
2 hrs.
3 hrs.
4 hrs.
8 hrs.
EXP6N18
18
12
–
–
–
EXP6N25
25
18
9
9
–
570.0011
EXP6N36
36
21
12
12
6
L18
570.0030
EXP6N50
50
36
18
18
10
1076
L25
570.0031
EXP12N36
36
21
12
12
6
6W
784
LH4
580.0012
EXP12N50
50
36
18
18
10
6V
8W
785
LH5
580.0013
EXP12N72
72
42
24
24
12
6V
10W
787
LH7
580.0017
6V
12W
786
LH6
580.0011
12V
8W
774
LH8
580.0014
12V
12W
783
LH3
580.0015
6
12
*National Electrical Code Specification
POWER CONSUMPTION CHART 120/277VAC, 60Hz maximum 0.3/0.15A
X402 EXIT SIGN (ONLY), LAMP SELECTION CHART (lamp automatically specified in model number based on voltage of unit) LAMP TYPE Quartz Bi-Pin
VOLTAGE 6V
LAMP WATTAGE 15W
12V Medium Base
24V
25W
120V
LAMP TYPE
AVERAGE LIFE (HOURS)
LAMP SUFFIX
REPLACEMENT LAMP PART #
JC-6V15W
2000
6
580.0086
25A-12
1000
12
570.0071
143A
1000
24
570.0118
A19
2500
120
570.0136
ORDERING FORMAT AC-Only or AC/DC Exit Sign Faces 1= Single Face 2= Double Face
Series X402
Mounting C= Ceiling W= Wall P= Pendant
Lamp -6= 6V -12= 12V -24= 24V -120= 120V
Transfer Panel (Required for the operation of the X402 AC/DC Exit Sign) AC voltage DC voltage Series 120= 120V AC -6= 6V DC -TS 277= 277V AC -12= 12V DC -24= 24V DC
Legend color R= Red G= Green
Watts -25= 25W -50= 50W -75= 75W -100= 100W
EXAMPLE: AC-Only or AC/DC Exit Sign: 1X402C12R, Transfer Panel (needed for AC/DC operation): 12012TS25
ORDERING FORMAT Self-Powered Exit (Includes a Nickel-Cadmium battery) Series EXP6N25 EXP6N36 EXP6N50 EXP12N36 EXP12N50 EXP12N72
Transfer Panel TS
Exit Sign X4021
1 1
Legend color R= Red G= Green
E XP6N includes 6V-15W Bi-Pin Halogen lamp EXP12N includes 12V-25W Bi-Pin Halogen lamp
EXAMPLE: EXP12N36TS402R
ORDERING FORMAT Combination Unit (Includes a Nickel-Cadmium battery) Series Light Head Light Head Lamp Transfer Panel Exit Sign EXP6N25 E402 Refer to E402 Light Head (only), Lamp Section Chart to specify lamp suffix TS X402* Based on Model, Choose a lamp up to: EXP6N36 EXP6N25= 6V-10W EXP12N36= 12V-11W EXP6N50 EXP6N36= 6V-18W EXP12N50= 12V-25W * EXP6N includes 6V-15W Bi-Pin EXP12N36 Halogen lamp EXP6N50= 6V-18W EXP12N72= 12V-25W EXP12N50
Legend color R= Red G= Green
* EXP12N includes 12V-25W Bi-Pin Halogen lamp
EXP12N72
EXAMPLE: EXP6N36E402LH6TSX402R
www.lightalarms.com
49
TYPE
XT TRITIUM™ SELF-LUMINOUS SERIES
CATALOG #
Non-electric, uses no electrical power internally or externally to illuminate
NOTES
FEATURES
SPECIFICATIONS
Construction • Housing and frame are made of ABS Molding • Faceplate lens is .13 thick acrylic • Legend is non-glare polycarbonate • Tamper-proof assembly with no removable fasteners • 6” EXIT lettering legend, background available in Red or Green Mounting • Surface Mount • Single face model includes (1) housing, (1) faceplate and (1) canopy • Canopy included for wall, end or ceiling mount applications • Double face model includes (2) housings, (2) faceplates and (1) canopy • Canopy included for end or ceiling mount applications Finishes • Choice of finishes: white or black Chevrons • Two field-selectable direction chevrons No Power Required • Non-electric, uses no electrical power internally or externally to illuminate • No wiring needed to operated • No need to be illuminated by absorbing light from another source • Spark-free, no filament, suitable for use in humid, corrosive or explosive environments Illumination • Provided by phosphor-coated borosilicate tubes filled with tritium gas • Low energy beta emission of tritium striking the phosphor coating inside the glass tubes generates illumination for the life of the sign Special Wording Panel Not Available Approvals • NFPA Life Safety Code 101 • UL 924 • City of Los Angeles • State of California • Council of American Building Officials (ICBO, SBCCI) • OSHA • USNRC • ISO 9001 Warranty • Full warranty for life of sign (subject to proper installation and maintenance) • 10 year sign=10 full year warranty • 20 year sign=20 full year warranty
Supply and Install Lightalarms® XT Tritium™ Self-Luminous Series Exit Sign. The housing, frame and canopy is ABS Molding with a clear faceplate of .13 thick acrylic. Housing, frame and canopy shall be matching in finish, (W) white or (B) black. A choice of non-glare polycarbonate legend (R) red or (G) green includes field-selectable, chevron indicators. Constructed in a tamper-proof assembly with no removable fasteners and no screws are necessary to hold the Exit Sign together. The Exit Sign shall be suitable for surface mount, wall, ceiling or end installations. The illumination source shall be provided by phosphor-coated borosilicate tubes filled with tritium gas. Low energy beta emission of tritium striking the phosphor coating inside the pyrex glass tubes shall generate illumination for the life of the sign. The illumination provides the 6” high by ¾” stroke exit letters with even illumination and no hot spots. The Exit Sign shall consume 0 watts of AC power energy, being non-electric, using no electrical power internally or externally to illuminate, no wiring needed to operate, and no need to be illuminated by absorbing light from another source. Spark-free, with no filament, suitable for use in humid, corrosive or explosive environments. The Exit Sign shall have the approval of UL Underwriters Laboratories, OSHA – Occupational Safety and Health Administration, BOCA, ICBO, SBCCI – American Building Officials, MSHA – Mine Safety and Health Administration, NRC – Nuclear Regulatory Commission, Uniform, Basic and Standard Building Codes, meets ANSI (American National Standards Institute) for use in harsh or dangerous environments, meets requirements of NEC (National Electric Code), Class I and II. Full warranty for the life of the sign, 10 year sign=10 full year warranty, 20 year sign= 20 full year warranty. The Exit Sign shall be Lightalarms® Model ____________________________.
ACCESSORIES
DIMENSIONS
Dimensions are approximate and subject to change. Fully Recessed FR Option 9.625” [24.45 cm]
1.125” [2.86 cm] 8.375” [21.27 cm]
14.5” [39.37 cm] 14.125” [35.88 cm]
1.125” [2.86 cm] 9.625” 8.125” [24.45 [20.64 cm] cm]
14.125” [35.88 cm]
Back Box
MOUNTING
(Order as a separate item)
Single Face Signs
PW-* PB-* PA-* WG13-L WG5-L WG15-L
White Pendant Black Pendant Gray Pendant Wire Guard-Wall Mount Wire Guard-Ceiling Mount Wire Guard-End Mount
Wall Mount (flush wall or end)
Ceiling Mount (flush ceiling)
Pendant Mount
Ceiling Mount (flush ceiling)
Pendant Mount
Double Face Signs
Wall Mount (flush end)
*Specify length of pendant (12”, 24”, 36” etc.)
ORDERING FORMAT SERIES XT= Single Face 2XT= Double Face
SIGN LIFE 10= 10 Years 20= 20 Years
HOUSING COLOR W= White B= Black GY= Grey
LEGEND COLOR R= Red G= Green
OPTIONS -AF= Aluminum Frame -AFPC= Aluminum Frame and Polycarbonate Shield -FR= Fully Recessed Frame
EXAMPLE: XT10WR-AF-N 50
Trim Plate
www.lightalarms.com
NEW -N= New Version
TYPE
PENDANT KITS
CATALOG #
For Exit Signs and Special Wording Signage
NOTES
SPECIFICATIONS Made of metal, offered in a variety of colors and lengths. Compatible with both horizontal and sloped ceilings. Lightalarms® pendant kits are designed to facilitate the installation of Exit Signs or Special Wording Panel Signage to regular mounting heights. Please consult your sales representative.
DIMENSIONS
Dimensions are approximate and subject to change.
Length
P SERIES
GENESIS SERIES GP SERIES
ORDERING FORMAT FOR UX4, GX AND SIMPLICITY™ PREMIUM SERIES SERIES P1 GP2 1 2
COLOR W= White B= Black A= Gray/Aluminum
LENGTH (IN INCHES) 12 24 36 48
MODEL
60 72 84 96
L
For use with Simplicity™ Premium & UX4 Series For use with Genesis™ Series
EXAMPLE: PW24L
ORDERING FORMAT FOR GRANDE™ SERIES SERIES GRA-P1 1
For use with Grande™ Series
LENGTH (IN INCHES) 12 24 36 48
60 72 84 96
COLOR WT= White B= Black A= Gray/Aluminum
MODEL L
EXAMPLE: GPW24L
ORDERING FORMAT FOR SIMPLICITY™ ECONOMIZER SE, SES & SEN SERIES SERIES SE-P
LENGTH (IN INCHES) 12 24 36
48 60 72
COLOR 84 96
WT= White B= Black A= Gray/Aluminum
EXAMPLE: SE-P12-WH
www.lightalarms.com
51
SPECIAL WORDING PANELS
Customized special wording panels available for use in our Exit Signs and Combination Units
TYPE CATALOG #
NOTES
FEATURES • The same sturdy construction and electrical design used in our Exit Signs and Combination Units, is used to produce our custom-worded, illuminated signage • Sign bodies: steel, extruded and die-cast aluminum, weatherproof, flameretardant polycarbonate, high impact Thermoplastic, recessed housing • Custom wording: any style of lettering, any language, any alphabet, any special characters • Graphics: logos, standard symbols, custom art • Color choices: sign bodies, message, faceplate panel • llumination: LED (light-emitting diodes) • Contact your local Lightalarms® representative to discuss your specific requirements Custom signage panels are available for use in the following Series: Simplicity™ Premium Series page 14-15 Simplicity™ Economizer Series page 16-17 Genesis™ GX, GXE Series page 22-23 Galaxy™ XD, XDN Series page 24-25 Galaxy™ XDPC Series page 26-27 UX4 LED Series page 28-29 Grande™ Series page 30-31 Grande™ Combination Series page 32-33 Severe™ NEMA 4X Series page 40-41 Severe™ NEMA 4X Combination Series page 42-43 Severe™ Class I, Division 2 Series page 44-45 Severe™ Class I, Division 2 Combination Series page 46-47 X402, EXP and Combination Class I & II, Division 1&2 page 48-49
ELEVATOR DANGER
NO SMOKING
HELP NOT AN EXIT
STAIRS
LADIES
52
www.lightalarms.com
TYPE CATALOG #
SPECIAL WORDING For Exit Signs and Special Wording Signage
NOTES
Note: Shown above are only a few examples of special wording panels that we have produced. Many more panels are available to meet any customized order.
www.lightalarms.com
53
Battery Units
INTRODUCTION About Battery Units
INTRODUCTION Quick Reference Lamp Chart
ARCHITECTURAL Recessed Mount Phantom™ Series
ARCHITECTURAL Recessed Mount Mini-Phantom™ Series
ARCHITECTURAL Recessed Mount TBR Series
56-58
59
60-61
62-63
64-65
ARCHITECTURAL Recessed Mount RD Series
COMMERCIAL Recessed Mount LS605P1 Series
COMMERCIAL Surface Mount LCA-2SQ Series
COMMERCIAL Cluster™ LED LCA-2LEDR Unit & ELF652D Series
COMMERCIAL Surface Mount LCA-2 Series
66-67
68
69
70-71
72
COMMERCIAL Surface Mount LCA1250 Series
COMMERCIAL Surface Mount Grande™ Series
ARCHITECTURAL Surface Mount Indoor or Outdoor Camray® LED Series
COMMERCIAL Surface Mount MC Series
COMMERCIAL Surface Mount PG & P12G Series
73
74-75
76-77
78-79
80-81
COMMERCIAL Surface Mount PN & P12N Series
COMMERCIAL Surface Mount PQ & P12Q Series
INDUSTRIAL Surface Mount S12E & S24E Series
INDUSTRIAL Surface Mount Weather & Corrosion Resistant FG & FN Series
INDUSTRIAL Surface Mount NEMA-4X & NSF Rated Severe™ V Series
82-83
84-85
86-87
88-89
90-91
INDUSTRIAL Surface Mount Hazardous Location Severe™ VH Series
INDUSTRIAL Surface Mount Hazardous Location EXP6N & EXP12N Series
92-93
94-95
www.lightalarms.com
55
Emergency Lighting Battery Units Emergency Battery Unit Equipment:
Circuitry
Illumination provided by an emergency lighting battery life safety unit is one of the key elements to ensuring safety within a public building. In the event of a failure of the normal power supply, self-contained emergency lighting battery units automatically provide the illumination required to evacuate the building in a safe manner. Lightalarms® offers a wide selection of emergency lighting battery units to meet your demanding needs and requirements, whether it’s for an architectural application or a Hazardous Location. With the many emergency lighting battery units available, the key is choosing the correct one to do the job. The appropriate Emergency Lighting Battery Unit will ensure that the proper emergency illumination is being provided. An emergency lighting battery unit is life saving equipment.
Circuitry selection is typically based on the mounting location and the amount of work that will be required to test the Emergency Battery Unit. As required by code, in accordance with NFPA101 (Life Safety Code), an emergency battery unit must be tested every month, including a full 90-minute discharge test every year. Testing of each emergency lighting unit takes many man-hours and also requires that written logs be kept on all testing to present to a fire inspector on demand. If a unit is mounted in a location not easily accessible, self-diagnostic circuitry allows an inspector to walk to each unit see the test results via LED indicators on the unit and then note them in the written log. If the building owner wants to reduce the man-hours required to meet testing requirements and eliminate the need for an inspector to keep written logs, then the Nexus® system can be installed. The Nexus® self-testing and monitoring system tests each unit automatically at the exact time and day requested, keeps the results and history of each test, diagnoses any problem, indicates which part is needed to fix the problem, and identifies the location of the problematic unit and sends an email notification to the person responsible for testing and maintaining all the emergency lighting units.
To select the correct Emergency Lighting Battery Unit, consider these 4 components: Housing, Circuitry, Battery, and Lamps. 1) Housing: Select a housing designed for the location where the unit will be installed; for example, indoors, outdoors, or in a vandal-prone or hazardous area. 2) Circuitry: The circuitry maintains the battery and allows the unit to be tested. Will standard circuitry meet your requirements, or does your application need selfdiagnostics or the state-of-the-art Nexus® system? 3) Battery: Lead-Calcium works best in controlled temperatures; and NickelCadmium is for wider temperature ranges. 4) Lamps: Be sure to provide the sufficient illumination or lumens required to illuminate the area for safe evacuation. Select the proper emergency lighting battery unit for the specific application. Pick the proper lamps to provide the illumination needed to illuminate the area. Select the appropriate sized battery to provide DC power to illuminate the lamps for 90 minutes. Use the correct circuitry to maintain the battery and operate the lamps. To protect it all, use the proper housing for the environment where the emergency lighting battery unit will be located.
Housing The required housing construction of emergency lighting battery units depends on the location where the equipment is to be installed. Of all the components, the housing is the one most affected by the external environment. The housing plays many roles: it provides the fixture with a degree of protection against the environmental conditions, and meets technical, aesthetic and functional requirements. In general, non-residential lighting is divided in three market segments: commercial, institutional and industrial. This market segmentation still applies in the case of emergency lighting. Typically, the commercial and institutional sectors are more sensitive to costs and aesthetics, whereas the industrial sector is more influenced by technical aspects (fixture durability, etc.) of the product. Commercial spaces (stores, restaurants, hotels etc.) as well as institutions (schools, hospitals) are generally air-conditioned and have a controlled environment. When the equipment operates in normal temperature and humidity conditions, it typically only requires a NEMA1 rated housing with a Lead-Calcium battery. Industrial environments are the most severe and require rugged housing construction. Industrial housing types are defined by a number of parameters specific to various technical processes within the industry: temperature range, degree of humidity, degree of protection against water and dust, and resistance to corrosive chemicals, etc. requiring a NEMA 4X or higher rating.
56
www.lightalarms.com
TYPE CATALOG #
NOTES
Battery The most important thing to consider when picking a battery is the temperature of the environment where the battery will be located. The ideal temperature for battery performance is 77˚F. Cold temperatures affect the capacity, and hot temperatures affect the life of the battery. The temperature may affect the wattage size of the battery required. If you need a required amount of wattage to illuminate the lamp heads on the emergency lighting battery unit and the battery is in a cold area, that battery may not be able to deliver the required wattage needed for 90 minutes of operation. For example, at 32˚F, a Lead-Calcium battery will be at approximately 75% of capacity; but, a Nickel-Cadmium battery will be at approximately 95% of capacity. If a battery is in a high temperature area, that battery may have a reduced life expectancy. For Lead-Calcium batteries every 15-20 degree increase in ambient temperature reduces the life of the battery by half (approximately). Sealed Maintenance-Free Lead-Calcium: (Good) Design Feature: Recombination technology. Does not gas externally under charging. Temperature Range: 32°F -100°F Expected Life: 4-8 years Warranty: 3 years full warranty, 3 years pro rata warranty Sealed Maintenance-Free Nickel-Cadmium: (Better) Design Feature: High abuse battery, operates well in extreme temperatures. Temperature Range: 0°F -131°F Expected Life: 15 years Warranty: 5 years full warranty, 7 years pro rata warranty Sealed Maintenance-Free Nickel-Metal Hydride: (Best) Design feature: Similar to Nickel-Cadmium, Environmentally Friendly, Cadmium-Free and Lead-Free
Lamp Base the lamp choice for the emergency lighting battery unit on the lumen output of the lamp and the illumination required during an emergency situation. The sole purpose of an emergency lighting battery unit is to illuminate a path of egress in an emergency situation to evacuate people safely. Picking a lamp without enough lumen output will not provide a safe situation. If emergency lighting battery unit lamps are insufficient to illuminate the path of egress, the unsafe situation could lead to bodily injury or even death. The average illumination provided to a path of egress should be at least 1 ft-candle at floor level.
www.lightalarms.com
57
Emergency Lighting Battery Units Hazardous Location Classifications Hazardous areas are locations where the potential for explosion or fire exists due to the presence of certain gases, liquid vapors, or combustible dusts or fiber particles suspended in the air. The National Electrical Code®, NEMA, OSHA, UL, NFPA (Life Safety Standards), as well as State and Local codes, dictate the type of emergency lighting equipment to be used in different Hazardous Locations. In Hazardous Locations, the emergency lighting equipment must be a type which will not itself contribute to the ignition of flammable or explosive substances present in the location. Lightalarms® offers emergency lighting equipment dedicated for use in Hazardous Locations. Class I (NEC-500-5) Areas in which flammable gases or vapors may be present in sufficient quantities to be explosive or ignitable. Class ll (NEC-500-6) Areas made hazardous by the presence of combustible dust. Class Ill (NEC-500-7) Areas in which there are easily ignitable fibers or flyings present, due to the type of material being handled, stored or processed-but in which such fibers or flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitable mixtures. Division I (NEC-500-5, 6 & 7) Normal Situation: A hazard is present in the everyday normal production operation or during frequent repair and/or maintenance activity. Division II (NEC-500-5, 6 & 7) Abnormal Situation: Potentially hazardous material is expected to be safely contained within closed containers or closed systems, and will be present in the atmosphere only through accidental rupture, breakage, or abnormal operation. Group A, B, C & D (NEC-500-3) Gases and vapors in Class I locations are classified into four groups: code A, B, C, and D. These materials are grouped according to the ignition temperature of the substance, its explosion pressure and other flammable characteristics. Groups E, F & G (NEC-500-3) Combustible dust in Class II locations is classified according to ignition temperature and the conductivity of the hazardous substance. Typical Class I Locations: • Petroleum refineries, gasoline storage and dispensing areas. • Industrial firms that use flammable liquids in dip tanks for parts cleaning or other applications. • Petrochemical companies that manufacture chemicals from gas and oil. • Dry cleaning plants where vapors from cleaning fluids can be present. • Companies that have spraying areas where they coat products with paint or plastics. • Aircraft hangars and fuel servicing areas. • Utility gas plants, and operations involving storage and handling of liquified petroleum gas or natural gas Typical Class ll Locations: • Grain elevators, flour and feed mills. • Plants that manufacture, use or store magnesium or aluminum powders. • Plants that have chemical or metallurgical processes, producers of plastics, medicines, and fireworks etc. • Producers of starch or candies. • Spice grinding plants, sugar plants and cocoa plants. • Coal preparation plants and other carbon handling or processing areas.
58
Typical Class Ill Locations: • Textile mills, cotton gins, cotton seed mills and flax processing plants. • Clothing manufacturing plants • Any plant that shapes, pulverizes or cuts wood and creates saw dust or flyings. For more information consult the National Electrical Code®.
NEMA Enclosures Type 1 – Intended for use indoors primarily to prevent accidental contact of personnel with the enclosed equipment. Type 2 – Intended for use indoors to protect the enclosed equipment against falling non-corrosive liquids and falling dirt. Type 3 – Intended for use outdoors to protect the enclosed equipment against rain, windblown dust, sleet and external ice formation. Type 3R – Intended for use outdoors to protect the enclosed equipment against falling rain, sleet and external ice formation. Type 4 – Intended for use indoors and outdoors to protect the enclosed equipment against windblown dust, rain, splashing water and hose-directed water. Type 4R – Intended for use indoors and outdoors to protect the enclosed equipment against windblown dust, rain, splashing water and hose-directed water; that provides an additional level of protection against corrosion. Type 5 – Intended for indoor use primarily to protect against dust and falling dirt. Type 6 – Intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during occasional temporary submersion at a limited depth. Type 6P – Intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during prolonged submersion at a limited depth. Type 7 – Intended for use indoors in locations classified as Class I, Groups A, B, C, or D as defined in the National Electrical Code®. Type 8 – Intended for indoor or outdoor use in locations classified as Class I, Groups A, B, C, & D as defined in the National Electrical Code®. Type 9 – Intended for indoor locations classified as Class II, Groups E, F & G, as defined in the National Electrical Code®. Type 10 – Enclosures are constructed to meet the applicable requirements of the Mine Safety and Health Administration. Type 11 – Intended for indoor use primarily to provide, by oil immersion, a degree of protection to enclosed equipment against the corrosive effects of liquids and gases. Type 12 – Intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping noncorrosive liquids. Type 12K – Enclosure with knockouts intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids other than at knockouts. Type 13 – Intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil, and noncorrosive coolant.
www.lightalarms.com
EXP6N & EXP12N SERIES (PAGE 94-95)
X
SEVERE VH SERIES (PAGE 92-93)
X
SEVERE™ V SERIES (PAGE 90-91)
X
FG & FN SERIES (PAGE 88-89)
X
S12E, S24E SERIES (PAGE 86-87)
X
PN & P12N SERIES (PAGE 82-83)
X
PG & P12G SERIES (PAGE 80-81) PQ & P12Q SERIES (PAGE 84-85)
X
MC SERIES (PAGE 78-79)
X
CAMRAY® SERIES (PAGE 76-77)
X
GRANDE™ SERIES (PAGE 74-75)
LS605P1 SERIES (PAGE 68)
X
LCA1250 SERIES (PAGE 73)
RD SERIES (PAGE 66-67)
X
LCA-2MRS & LED SERIES (PAGE 72)
T-BAR TBR SERIES (PAGE 64-65)
X
LCA-LEDR (PAGE 70-71)
MINI-PHANTOM™ SERIES (PAGE 62-63)
X
LCA-2SQ SERIES (PAGE 69)
PHANTOM™ SERIES (PAGE 60-61)
Quick Reference Chart
X
X
X
X
X
X X
X X X
X X X X
X
X X
X
X
X
X
X
X X
X X
X
X
X X X
X
X X
X X
APPLICATION Architectural Commercial Industrial Recessed Mount Surface Mount Remote Capacity Damp Listed NEMA 4X Hazardous Locations
X
X
X
X
X
X
X
X
X X X X
X
X X X
X
X
X
X
X X X
X
X X
X X
X X
X
HOUSING Thermoplastic Steel Other Materials
X
X
X
X
X X
X
X
X
X
X
X X
X
X
X
X
BATTERY Lead-Calcium Nickel-Cadmium Nickel-Metal Hydride
X X X
X X X
X X
X
X
X X
X X
X X
X
X
X
X X
X
X
X X
X
X X
X X
X X
X
X
COLOR Mist-White Black Gray Other Colors
X
X
X
X
X X
X X
X X
X X X X
X X X
X
LAMP OPTIONS MR16-LED MR16-Halogen Bi-Pin Halogen Sealed Beam Halogen Sealed Beam Incand. Wedge Base Incand.
X X
X X
X X X X X X
X X X X X X
X
X X
X X
X X
X
X
X
X X X X X X
X X X X X X
X X X X X X
X X X X X X
X X X X X
X X X X X
X X X X X
X X X X
X
X
AVAILABLE OPTIONS Improved-Diagnostic Ammeter Voltmeter Photocell Switch Time Delay (5, 10, 15 min) Heater/Cold Weather Vandal Screws Lamp disconnect Cord & Plug
X
X
X X X
X X X
X
X
X
X
X
X
X
X
X
X X X
X X
X X X X X X
X
X X X
X X X
X X
X
X
X
X
X
X
X
X X
X X
X X
X
X
X
X
X
X X X
X
ACCESSORIES Wire Guard Vandal Shield Mounting Shelf/Platform Mounting Bracket
X
X X
X X
X X
X
X
X
ORIGIN North America
X
X
X
X
X
X
X
X
X
X
X
X
NOTE: This is a quick reference guide only, refer to individual product pages for complete details regarding applicable models
www.lightalarms.com
59
PHANTOM™ SERIES The Unseen Solution 12V up to 100W Capacities – Generator Capable Lead-Calcium or Nickel-Cadmium battery FEATURES
SPECIFICATIONS
Housing • 20 gauge galvanized steel back-box • Head assembly designed for easy access to internal components • Head assembly door and trim plate powder coated in a white finish • Finish can be customized on site with paint or wallpaper • Provision for 2 lighting heads • Choice of MR16 Halogen or MR16 LED Lamp types and wattages • Complete 360° head assembly door rotation: 180° to open, 180° to close • Slip gear mechanism protects unit and objects against forcibly stop
Supply and install Lightalarms® Phantom™ Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 12V, wattage as specified in the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be CSA-US approved. The unit charger shall utilize an micro-controller which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, recessed illuminated combination test switch and indicator light. The unit shall be designed to be concealed in walls or ceilings with a cavity, including T-bar suspended ceilings. Bar hanger brackets shall be provided with the unit. The equipment shall consist of a metal back box containing the batteries, the lamp assembly and a charging circuitry. The back box shall be constructed of heavy-duty galvanized steel. The unit utilizes a modular design and comes with quick-connect plugs for easy installation into the back box. The unit equipment shall be completely concealed in the wall or ceiling during normal power conditions. Upon a power failure the unit will expose the emergency heads by rotating its door by 180° and then will power the lamps. At the restoration of the AC power or the end of the battery discharge, the lamps will turn off and the unit will retract the heads in the wall or ceiling by rotating the door by 180°. The unit shall not require the presence of AC power in order to rotate the door closed, returning the lamps inside the housing. Under normal conditions, the only visible parts of the unit will be the flat door and trim plate, coated with a high-quality off-white finish that can be customized on site with paint or other suitable wall covering. The light source shall be MR16 halogen or MR16 LED lamps of specified voltage and wattage. Units specified with Improved Diagnostics shall continuously monitor every critical function of the unit. If a malfunction occurs, if audible, a high-pitch audible alarm will sound; as well and, the recessed illuminated combination test switch and indicator light located on the front of the unit will change color from solid green to a flashing red light, indicating a fault. If non-audible, only the recessed illuminated combination test switch and indicator light located on the front of the unit will change color from solid green to a flashing red light, indicating a fault. A detailed diagnostic legend is available on the door back side and provides fault identification as battery, charger circuitry or lamps failure. The microcontroller shall automatically self-test by simulating a power failure, in accordance with NFPA101, Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually. Every Phantom™ Series unit shall be fully warranted for five years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Recessed mount into ceiling or wall with cavities • Special bar hangers included for installation in dry wall or T-bar ceilings • Includes the electrical junction box • Installed on the wall stud or ceiling beam with simple, U-shape bracket. • Head assembly includes keyhole slot and quick-connect plugs for easy installation Electronics • Automatic, temperature-compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 7. Controls • Recessed illuminated push button serves as test switch and status indicator Choice of Sealed Maintenance-Free Battery • 12V Lead-Calcium battery • 12V Nickel-Cadmium battery Approval • CSA-US Warranty (subject to proper installation and maintenance) • Unit has a five year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty 1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Remote Test Switch (Metal Faceplate) Remote Test Switch (Plastic Faceplate)
60
PSW PSW-1
www.lightalarms.com
US
TYPE
Visually invisible and architecturally designed for unobtrusive use in wallswith cavity (dry wall with 4-inch studs) or un-insulated ceilings with horizontal beams or T-bar structures
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change.
9-1/8” [23.17cm] 7-7/8” [20cm]
3-7/16” [8.73cm]
5-1/2” [13.97cm]
Charger & Battery Compartment: For use in walls or ceilings with a cavity, not for use in block walls or solid ceilings.
7-1/4” [18.41cm]
23-7/8” [60.64cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
PHM40
Lead-Calcium
DC VOLTAGE 12V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 40 30 24 12
PHM70
12V
70
50
40
24
PHM100
12V
100
70
50
40
12V
40
30
24
12
PHN40
Nickel-Cadmium
PHN70
12V
70
50
40
24
PHN100
12V
100
70
50
40
UNITS DUAL VOLTAGE2
120VAC 277VAC
2
ORDERING FORMAT BATTERY TYPE M= Lead-Calcium N= Nickel-Cadmium
BATTERY UNIT
SERIES PH
UNIT CAPACITY 40= 12V-40W 70= 12V-70W 100= 12V-100W
# OF HEADS -2= Two lamps
CURRENT MAXIMUM STAND BY
0.25A 0.12A
0.10A 0.05A
30W 30W
11W 11W
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type 3 Stand-by power consumption is 50% lower for Lead-Calcium Batteries
LAMP TYPE MR16 Halogen (12)= 12V-12W (20)= 12V-20W (35)= 12V-35W (50)= 12V-50W
POWER3 MAXIMUM STAND BY
MR16 Halogen High Output (20H)= 12V-20W (35H)= 12V-35W (50H)= 12V-50W
MR16 LED (LD7)= 12V-4W (LD9)= 12V-5W (LD10)= 12V-6W
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -DL= Damp Location2 -X= Back box shipped separate -ID & -IDNA include a time delay feature that can be enabled/ disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* 2 -DL option not available with PHN100 unit 1
For complete 12V MR16 lamp information refer to page 100 Remote Fixture, Phantom™ Series, Lamp Selection Chart
EXAMPLE: PHM100-2(20)DL
GENERATOR UNIT
SERIES PHG
INPUT VOLTAGE 1= 120VAC, 60Hz 2= 277VAC, 60Hz
# OF HEADS -2= Two lamps
LAMP TYPE MR16 Halogen (12)= 12V-12W (20)= 12V-20W (35)= 12V-35W (50)= 12V-50W MR16 LED (LD7)= 12V-4W (LD9)= 12V-5W (LD9)= 12V-5W (LD10)= 12V-6W
MR16 Halogen High Output (20H)= 12V-20W (35H)= 12V-35W (50H)= 12V-50W
For complete 12V MR16 lamp information refer to page 100 Remote Fixture, Phantom™ Series, Lamp Selection Chart
EXAMPLE: PHG1-2(20)
www.lightalarms.com
61
MINI-PHANTOM
TM
SERIES
The Full Retrofit Unseen Solution 12V-40W Capacities – Generator Capable Lead-Calcium, Nickel-Cadmium or Nickel-Metal Hydride battery FEATURES
SPECIFICATIONS
Housing • Two 20 gauge steel modules joined by a flexible bracket and electric conduit • Head assembly door and trim plate powder coated in a white finish • Finish can be customized on site with paint or wallpaper • Provision for 2 lighting heads • Choice of MR16 Halogen or MR16 LED Lamp types and wattages • Complete 360° head assembly door rotation: 180° to open, 180° to close • Slip gear mechanism protects unit and objects against forcibly stop
Supply and install Lightalarms® Mini-Phantom™ Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium, Nickel-Cadmium or Nickel-Metal Hydride battery of 12V-40W. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be CSA-US listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to its temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay and recessed illuminated combination test switch and indicator light. The unit shall be designed to be concealed in walls with a cavity. The unit shall consist of a metal housing containing two modules joined by a flexible bracket and electric conduit. One module contains the battery, charger circuitry and electrical connection box; the other module contains the head assembly. Upon a power failure, the unit will expose the emergency lighting heads by rotating its door by 180° and then will power the lamps. At the restoration of the AC power or the end of the battery discharge, the lamps will turn off and the unit will retract the heads by rotating the door by 180°. The unit shall not require the presence of AC power in order to rotate the door closed, returning the lamps inside the housing. Under normal conditions, the only visible parts of the unit will be the flat door and trim plate, coated with a high-quality off-white finish that can be customized on site with paint or other suitable wall covering. The light source shall be 12V MR16 halogen or MR16 LED lamps of specified voltage and wattage. Units specified with Improved Diagnostics shall continuously monitor every critical function of the unit. If a malfunction occurs, if audible, a high-pitch audible alarm will sound; and; the recessed illuminated combination test switch and indicator light located on the front of the unit will change color from solid green to a flashing red light, indicating a fault. If non-audible, only the recessed illuminated combination test switch and indicator light located on the front of the unit will change color from solid green to a flashing red light, indicating a fault. A detailed diagnostic legend is available on the door, back side and provides fault identification as battery, charger circuitry or lamps failure. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code for minimum one minute monthly, 30 minutes every six months and 90 minutes annually. Every Mini-Phantom™ Series unit shall be fully warranted for five years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Recessed wall with cavity mount (retrofit into finished wall) • Designed to install into an 8-1/4” by 5-3/4” inch opening • Includes electrical junction box • Key-hole slot for ease of installation Electronics • Automatic, temperature-compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code minimum one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. Controls • Recessed illuminated push button serves as test switch and status indicator Choice of Sealed Maintenance-Free Battery • 12V Lead-Calcium battery • 12V Nickel-Cadmium battery • 12V Nickel Metal Hydride battery Approval CSA-US Warranty (subject to proper installation and maintenance) • Unit has a five year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty • Nickel-Metal Hydride battery has a five year full, plus five year pro-rata warranty 1
For LED lamps warranty, refer to page 168 paragraph 3.2
DIMENSIONS
Dimensions are approximate and subject to change. 3 1/2” Mounting Bracket [8.9 cm]
9-1/8” [23.18cm]
7” [17.78cm]
ACCESSORIES (Order as a separate item)
5 1/4” [13.33cm] 17 5/8” [44.77cm]
7 3/4” [19.68cm]
62
Complete Unit
Remote Test Switch (Metal Faceplate) Remote Test Switch (Plastic Faceplate)
Installed Unit
www.lightalarms.com
PSW PSW-1
US
TYPE
Designed for retrofitting in finished walls with a cavity (dry-wall with 4-inch studs).
CATALOG #
NOTES
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS
AC SPECS
MPHM40
Lead-Calcium
12V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 40 30 24 12
MPHN40
Nickel-Cadmium
12V
40
30
24
12
MPHH40
Nickel-Metal-Hydride
12V
40
30
24
12
BATTERY TYPE
DC VOLTAGE
UNITS DUAL VOLTAGE2 120VAC 277VAC
2
ORDERING FORMAT SERIES MPH
BATTERY TYPE M= Lead-Calcium N= Nickel-Cadmium H= Nickel-Metal Hydride
UNIT CAPACITY 40= 12V-40W
# OF HEADS -2= Two Lamps
0.25A 0.12A
0.10A 0.05A
POWER3 MAXIMUM STAND BY 30W 30W
11W 11W
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type 3 Stand-by power consumption is 50% lower for Lead-Calcium Batteries
LAMP TYPE MR16 Halogen (12)= 12V-12W (20)= 12V-20W MR16 Halogen High Output (20H)= 12V-20W MR16 LED (LD7)= 12V-4W (LD9)= 12V-5W (LD10)= 12V-6W
BATTERY UNIT
CURRENT MAXIMUM STAND BY
For complete 12V, up to 20W MR16 lamp information refer to page 100 Remote Fixture, Phantom™ Series, Lamp Selection Chart
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -DL= Damp Location -TB= T-Bar mounting kit
-ID &-INDA include a time delay feature that can be enabled/ disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD*
1
EXAMPLE: MPHM40-2(20)DL SERIES
INPUT VOLTAGE 1= 120VAC, 60Hz 2= 277VAC, 60Hz
GENERATOR UNIT
MPHG
# OF HEADS -2= Two Lamps
LAMP TYPE MR16 Halogen (12)= 12V-12W (20)= 12V-20W (35)= 12V-35W (50)= 12V-50W
MR16 Halogen High Output (20H)= 12V-20W (35H)= 12V-35W (50H)= 12V-50W
OPTIONS -DL= Damp Location
MR16 LED (LD7)= 12V-4W (LD9)= 12V-5W (LD10)= 12V-6W
For complete 12V MR16 lamp information refer to page 100 Remote Fixture, Phantom™ Series, Lamp Selection Chart
EXAMPLE: MPHG1-2(20)-DL
www.lightalarms.com
63
TBR SERIES Recessed Steel Housing 6V up to 81W, 12V up to 110W, 24V up to 110W Capacities Lead-Calcium or Nickel-Cadmium battery
Shown with ELF645 heads
FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing designed for easy access to internal components • Corrosion-resistant baked enamel mist white finish standard, black optional • Provision for mounting up to 3 lighting heads • Various choices of lighting head styles and lamp types Mounting • Recessed T-Bar ceiling mount; lay-in installation for grid ceiling only Electronics • Automatic, temperature-compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnoses, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V, 12 or 24V Lead-Calcium battery • 6V, 12 or 24V Nickel-Cadmium battery Approval • UL 924 Listed Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty
Supply and install Lightalarms® TBR Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 6V, 12V or 24V of wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The housing shall be 20 gauge steel, designed for provision for mounting up to 3 heads, T-Bar ceiling grid installation and for easy access to internal components. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit including the attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101 Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually Every TBR Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
DIMENSIONS
Dimensions are approximate and subject to change.
For LED lamps warranty, refer to page 168 paragraph 3.2
23-3/4” 23 3/4” [60.32cm]
11 1/2” [29.21cm]
13 1/8” 13-1/8” [33.33cm]
11-1/2”
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
ELF2
(pg.108)
(pg.105)
Wedge Based Incandescent
X
X
Bi-Pin Halogen
X
X
PAR36 Sealed Beam Incandescent
X
PAR36 Sealed Beam Halogen
X
ELF3
(pg.106)
(pg.104)
MR16 Halogen
X
X
MR16 LED
X
X
ACCESSORIES (Order as a separate item) Remote Test Switch (Metal Faceplate) Remote Test Switch (Plastic Faceplate)
64
a
DR1130
PSW PSW1 www.lightalarms.com
b
7 1/4” 7-1/4” [18.41cm]
Shown with: ELF645
ELF2 / ELF3
Units
Cabinet
a
b
54W and under 81W and higher
S L
3 1/4” 5 5/8”
4 5/8” 7 1/8”
TYPE
Designed for unobtrusive use in T-Bar ceilings. The off-white, fully recessed housing harmonizes with ceiling designs
CATALOG #
NOTES
Shown with ELF3 heads and LED lamps
Available Head Style Choices: ELF645 Head Style Suffix: /Blank
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
TBRC0
Lead-Calcium
DC VOLTAGE
90 MIN.
2 HRS.
3 HRS.
4 HRS.
6V
18
12
0
6V
27
18
14
10
TBRC5
6V
36
25
20
14
TBRC2
6V
54
37
28
21
6V
81
54
42
30
T12BRC0
12V
54
37
28
21
T12BRC1
12V
110
72
56
40
Nickel-Cadmium (with option-N)
TRBC2
DR1130 /D1
24V
110
72
56
40
6V
18
12
0
0
6V
25
18
12
9
T12BRC1
12V
36
21
15
12
T12BRC2
12V
50
36
25
18
2
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
0.3A 0.15A
0
TBRC3
T24BRC1
ELF3 /E3
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1
TBRC1
TRBC1
ELF2 /ELF2
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
ORDERING FORMAT # OF HEADS Blank= No heads 1= 1 head 2= 2 heads 3= 3 heads
SERIES/BATTERY/CAPACITY Lead-Calcium Battery TBRC0= 6V-18W TBRC1= 6V-27W TBRC5= 6V-36W TBRC2= 6V-54W TBRC3= 6V-81W T12BRC0= 12V-36W T12BRC2= 12V-54W T12BRC1= 12V-110W T24BRC1= 24V-110W For Nickel-Cadmium Battery (MUST INCLUDE OPTION -N) TRBC1= 6V-18W TRBC2= 6V-25W T12BRC1= 12V-36W T12BRC2= 12V-50W
HEAD STYLE /Blank= ELF645 (PAR36, Plastic) /ELF2= ELF2 (PAR18, Plastic) LED /E3= ELF3 (MR16, Plastic) /D1= DR1130 (MR16, Metal)
LAMP TYPE Add lamp suffix to indicate lamp type, voltage and wattage. For available Lamp Types within a specified Head Style refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 108 with ELF2, page 105 with ELF3, page 106 with DR1130, page 104 Lamp Type MUST: 1) Match battery voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min. 3) S ealed Beams not compatible with Nickel-Cadmium battery
OPTIONS Blank= Mist White housing, No Options -B= Black Housing -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -TD5= Time Delay (5 minutes) -TD10= Time Delay (10 minutes) -TD15= Time Delay (15 minutes) -A= Ammeter3 -V= Voltmeter3 -N= Nickel-Cadmium battery
- ID & -IDNA include a time delay feature that can be enabled/disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* 2 -NEX & -NEXRF is CSA-US approved only. Consult your sales representative 3 -A & -V not available with -ID, -IDNA, -NEX, -NEXRF option 1
EXAMPLE: 2TBRC1/L9-V
www.lightalarms.com
65
RD SERIES Recessed Steel Housing 6V up to 36W, 12V up to 36W Capacities Lead-Calcium or Nickel-Cadmium battery
shown with ELF3 heads
FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing designed for easy access to internal components • Corrosion-resistant baked enamel mist white finish standard, black optional • Provision for mounting up to 2 lighting heads • Various choices of lighting head styles and lamp types
Supply and install Lightalarms® RD Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 6V or 12V of wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be 20 gauge steel designed with mounting brackets included for lay-in installation in T-Bar grid ceiling as well as sheet rock. Unit has provision for mounting up to 2 heads on cabinet. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101 Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually Every RD Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number________________________.
Mounting • Ceiling or Wall Mount; Mounting Brackets included for lay-in installation in T-Bar grid ceiling as well as dry wall Electronics • Automatic, temperature-compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Lead-Calcium battery • 6V or 12V Nickel-Cadmium battery Approvals • UL 924 Standard
DIMENSIONS
Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty 1
Dimensions are approximate and subject to change. 11-1/2” [29.21cm]
BACK BOX
For LED lamps warranty, refer to page 168 paragraph 3.2
7-1/4” [18.41cm]
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
ELF2
(pg.108
(pg.105)
Wedge Based Incandescent
X
X
Bi-Pin Halogen
X
X
PAR36 Sealed Beam Incandescent
X
PAR36 Sealed Beam Halogen
X
ELF3
10-7/8” [27.62cm]
DR1130
(pg.106)
(pg.104)
ELF645
6 3/4” [17.14cm]
MR16 Halogen
X
X
MR16 LED
X
X 3 3/4” [9.52cm]
ACCESSORIES (Order as a separate item) Wire Guard (DR1130, ELF2, ELF3 or ELF645 heads) Remote Test Switch (Metal Faceplate) Remote Test Switch (Plastic Faceplate)
66
ELF2/ELF3
WG6-L PSW PSW1
www.lightalarms.com
9-7/8” [25.08cm]
8 1/4” [20.95cm]
TYPE
Designed for fully recessed installation in walls or ceilings
CATALOG #
NOTES shown with ELF3 heads and LED lamps
Available Head Style Choices: Head Style Suffix:
POWER CONSUMPTION / UNIT RATING CHART SERIES
Lead Calcium
DC VOLTAGE
90 MIN.
2 HRS.
3 HRS.
4 HRS.
6V
18
12
0
6V
27
18
14
10
RD6M3
6V
36
25
20
14
RD12M3 Nickel Cadmium
ELF3 /E3
DR1130 /D1
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1
RD6M2
RD6C1
ELF2 /ELF2
DC SPECS BATTERY TYPE
RD6M1
ELF645 /Blank
12
36
25
20
14
18
12
0
0
RD6C2
6V
25
18
12
9
RD12C3
12V
36
21
15
12
RD12C4
12V
50
36
25
18
2
CURRENT
120VAC 277VAC
0.3A 0.15A
0
6V
UNITS DUAL VOLTAGE2
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
ORDERING FORMAT # OF HEADS 0= No heads 1= One head 2= Two heads
SERIES/CAPACITY Lead-Calcium Battery RD6M1= 6V-18W RD6M2= 6V-27W RD6M3= 6V-36W RD12M3= 12V-36W Nickel-Cadmium Battery RD6C1= 6V-18W RD6C2= 6V-25W RD12C3= 12V-36W RD12C4= 12V-50W
HEAD STYLE /Blank= ELF645 (PAR36, Plastic) /ELF2= ELF2 (PAR18, Plastic) /E3= ELF3 (MR16, Plastic) /D1= DR1130 (MR16, Metal)
LAMP TYPE Add lamp suffix to indicate lamp type, voltage and wattage. For available Lamp Types within a specified Head Style refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 108 with ELF2, page 105 with ELF3, page 106 with DR1130, page 104
OPTIONS Blank= Mist White housing, No Options -B= Black Housing -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -T1= Time Delay (5 minutes) -T2= Time Delay (10 minutes) -T3= Time Delay (15 minutes) -A= Ammeter2 -V= Voltmeter2 -TBH= Suspended grid ceiling mounting kit3
Lamp Type MUST: 1) Match battery voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min 3) S ealed Beams not compatible with Nickel-Cadmium battery
V oltmeter and Ammeter not available with diagnostic ID, IDNA option ID & IDNA include a Time Delay feature that can be enabled/disabled in the field or set by the factory by including ID-TD* or IDNA-TD* 3 Sold as separate item 1
2
EXAMPLE: RD12M3/DR130M12-IDNA
www.lightalarms.com
67
LS605P1 SERIES Recessed Gimbal 6V up to 18W Capacities Lead-Calcium or Nickel-Cadmium battery
TYPE CATALOG #
NOTES
FEATURES
SPECIFICATIONS
Housing • Recessed upper drawn steel housing contains the battery and charger • Lower portion of the housing contains 8W halogen lamp • Designed with slide-out chassis and quick-connect plugs • Standard trim ring Thermoplastic • NYC approved features: metal trim and gimbal assembly Mounting • Recessed Ceiling Mount • Adjustable hanger bars are supplied with each unit Lamp Type • 6V-8W halogen lamp with a horizontal rotation of 358° and vertical angle adjustable to ±42° Electronics • Automatic, temperature-compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit. Controls • Combination AC-ON/battery charger monitor LED • Momentary test switch allows for operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V Lead-Calcium battery • 6V Nickel-Cadmium battery Approvals • UL 924 Standard • UL Listed for use in insulated ceilings Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty
Supply and install Lightalarms® Recessed Gimbal, 605P1, 605C1 Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 6V, wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, combination AC-ON/battery charger monitor LED, and a momentary test switch that allows for an operational check of the entire system. The housing shall be a drawn steel box, the upper side of the recessed upper housing contains the battery and charger, the lower portion of the housing contains halogen lamp. Standard finish of trim ring shall be mist-white plastic. NYC approved version will include a metal trim ring and gimbal assembly, also finished in mist-white or optional black. Slide-out chassis and two quick-connect plugs make installation and servicing easy. Adjustable hanger bars are supplied with each unit. Every Lightalarms® Recessed Gimbal, 605P1, 605C1 Series. Unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
DIMENSIONS
Dimensions are approximate and subject to change. 14” to 24” 7”
6-1/2” [16.51cm]
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item)
10-1/4” 10-1/4” [26.03cm]
PSW PSW1
Remote Test Switch (Metal Faceplate) Remote Test Switch (Plastic)
7-3/4” [19.68cm]
8-1/2” [21.59cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
LS605P1-HB
Lead-Calcium
DC VOLTAGE 6V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 10 0 0 0
SERIES/CAPACITY
.3A
National Electrical Code Specification 2 All units 120/277 dual voltage, information based on wiring to specific voltage type
LAMP TYPE
OPTIONS
/HB= 6V-10W Wedge base halogen
Blank= Mist White Thermoplastic
EXAMPLE: LS605P1/HB
68
CURRENT MAXIMUM
120VAC 1
ORDERING FORMAT LS605P1= 10W Lead-Calcium
UNITS DUAL VOLTAGE2
www.lightalarms.com
TYPE
LCA-2SQ SERIES
CATALOG #
Thermoplastic Housing 6V up to 23W Capacity Lead-Calcium battery
NOTES
FEATURES
SPECIFICATIONS
Housing • Injection-molded, UV stabilized Thermoplastic body, snap-together design • Two fully adjustable glare-free square lighting heads • Mist white finish, corrosion and scratch-resistant thermoplastic
Supply and install Lightalarms® LCA-2SQ, LCA-2SQR Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium battery of 6V-12W or 6V-23W. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz, UL 924 and Damp location listed standard. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, red charger monitor LED indicating charging of the battery and push test switch allows for quick operational check of entire system. The cabinet shall be injection-molded, UV stabilized Thermoplastic body, snap together design with two fully adjustable lighting heads being corrosion and scratch-resistant in a mist white color. Every LCA-2SQ, LCA-2SQR Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Ceiling or Wall Mount • Keyhole slots and universal knock-outs to mount to any standard 4” junction box Lamp Type • Two 6V-5.4W high intensity wedge base incandescent lamps Electronics • Automatic, temperature-compensated, charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery • Momentary test switch allows for quick operational check of entire system. Choice of Sealed Maintenance-Free Battery • 6V-12W Lead-Calcium battery • 6V-23W Lead-Calcium battery (11W remote capacity) Approvals • UL 924 Standards • UL 94, 5VA flame rated • Damp location listed
DIMENSIONS
Dimensions are approximate and subject to change.
Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty 1
12-1/4” [31.11cm]
4-3/8” [11.12cm]
For LED lamps warranty, refer to page 162-163 paragraph 3.2
ACCESSORIES (Order as a separate item)
5-1/8” [13.05cm]
WG10-L CPS CPS-4X
Wire Guard Vandal Resistant Shield Vandal Resistant Shield (NEMA-4X)
16-1/4” [41.27cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE Lead-Calcium
LCA-2SQ LCA-2SQR
AC SPECS
6V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 12 -
6V
23
DC VOLTAGE
16
-
2
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.08A .04A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
ORDERING FORMAT SERIES LCA
HEAD STYLE/LAMP TYPE -2SQ= 6V-5.4W Incandescent
CAPACITY Blank= No Remote Capacity R= 11W Remote Capacity
EXAMPLE: LCA-2SQ
www.lightalarms.com
69
CLUSTER™ LED LCA-2LEDR UNIT & ELF652D REMOTE HEAD SERIES
FEATURES
SPECIFICATIONS
Housing • Injection-molded, UV stabilized thermoplastic body, snap together design • Fully adjustable Cluster™ LED glare-free heads glare-free heads • Corrosion and scratch-resistant of mist white color
Supply and Install Lightalarms® Cluster™ LED LCA-2LEDR Series emergency light unit.
Mounting • Ceiling or Wall Mount • Keyhole slots and universal knock-outs to mount to any standard 4” junction box Lamp Type • White LED 3.6V-3.6W, with life expectancy 50,000+ hours Electronics • Automatic, solid-state • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided. • Battery lock-out prevents battery discharge during installation Improved Diagnostics option • Monitors battery/charger failure, battery disconnect and lamp failure Controls • Red charger monitor LED indicates charging of the battery • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • 3.6V Nickel-Metal Hydride battery
The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, red charger monitor LED indicating charging of the battery and push test switch allows for quick operational check of entire system. The cabinet shall be injection-molded, UV stabilized thermoplastic body, snap together design with two fully adjustable white Cluster™ LED glare-free lighting heads being corrosion and scratch-resistant in a mist white color. Every LCA-2LEDR Series unit shall be fully warranted for Three-years, subject to proper installation and maintenance.
Approvals • Listed to UL 924 Standards • UL 94, 5VA flame rated • UL listed for Damp location (68°F to 86°F, 20°C to 30°C)
The equipment shall be Lightalarms® Model:
9” [22.86cm]
.
DIMENSIONS
Warranty (subject to proper installation and maintenance) • Three-year full warranty (excluding lamps and fuses)1 • 3.6V Nickel-Metal Hydride battery, three-year full, five-year pro-rata warranty
Dimensions are approximate and subject to change.
For LED lamps warranty, refer to page 168 paragraph 3.2
2-3/4”[5.08cm] [5.08cm] 2-3/4”
9” 9” [22.86cm] [22.86cm]
4” [10.16cm]
1
The emergency lighting battery unit shall be a self-contained fixture including a 3.6V sealed maintenance-free Nickel-Metal Hydride battery. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz, UL924 and Damp location listed standard (68°F to 86°F, 20°C to 30°C).
4” [10.16cm]
4” [10.16cm]
2-3/4” [5.08cm]
70
www.lightalarms.com
TYPE
The Cluster™ LED Family features an emergency battery unit which includes extra battery capacity to power the Cluster™ LED ELF652D remote head or allow for extended run time.
CATALOG #
NOTES
POWER CONSUMPTION CHART SERIES
CURRENT (A) / POWER (W)
LCA-2LEDR
120VAC, 60Hz
277VAC, 60Hz
0.191/0.92
0.129/1.62
ORDERING FORMAT SERIES
LAMP
CAPACITY
LCA
-2LED= Cluster™ LED head style
Blank= No Remote R= Remote capacity RID= Remote capacity with Improved Diagnostics Note: Remote Capacity can ONLY be used to power the Cluster™ LED ELF652D Remote Head or the extend the battery units emergency run time beyond the standard 90 minutes.
Example: LCA-2LEDR
CLUSTER™ LED ELF652D REMOTE HEAD The Cluster™ LED ELF652D/LED Remote head can ONLY be powered from the UQLXN-2LED combo or LCA 2LED battery units of the same family. Used for internal or external applications, the indoor remote head draws 3.6V-3.6W and Weather-Proof head draws 3.6V-3.8W.
Indoor Remote
Weatherproof Remote
DIMENSIONS
Dimensions are approximate and subject to change.
Indoor Remote
Weatherproof Remote
2-1/16” [5.08cm] [5.24cm] 2-1/16”
7-6/16” [18.74cm] 5-10/16” [14.3cm]
4-11/16” [11.91cm] 4-11/16” [10.16cm]
6-11/16”[15.24cm] [16.99cm] 6-11/16”
ORDERING FORMAT SERIES
# OF HEADS
LAMP
OPTION
ELF652
D= Double Head
/LED= Cluster™ LED head style
Blank= Indoor Use Only -WP= Weather-Proof
Example: ELF652D/LED
www.lightalarms.com
71
AVAILABLE WITH LED LAMP HEADS TYPE
LCA-2MRS & LCA-2LD SERIES
CATALOG #
Thermoplastic Housing 6V-10W Capacity – Lead-Calcium battery
NOTES
FEATURES
SPECIFICATIONS
Housing • Injection-molded, UV stabilized thermoplastic body, snap-together design • Two fully adjustable glare-free MR16 lighting heads • Mist white finish, corrosion and scratch-resistant thermoplastic
Supply and install Lightalarms® LCA-2MRS & LCA-2LD Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium battery of 6V-12W. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz, UL 924 and Damp location listed standard. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, red charger monitor LED indicating charging of the battery and push test switch allows for quick operational check of entire system. The cabinet shall be injection-molded, UV stabilized thermoplastic body, snap together design with two fully adjustable glare-free MR16 lighting heads being corrosion and scratch-resistant in a mist white color. Every LCA-2MRS & LCA-2LD Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Ceiling or Wall Mount • Keyhole slots and universal knock-outs to mount to any standard 4” junction box Choice of Lamp Types • Two 6W each MR16 Halogen lamps • Two 4W each MR16 LED lamps Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • 6V Lead-Calcium battery Approvals • UL 924 Standards • UL 94, 5VA flame rated • Damp location listed
DIMENSIONS
Dimensions are approximate and subject to change. 3-3/4” [9.52cm]
Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty 1
5-1/2” [13.97cm]
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) WG10-L CPS CPS-4X
Wire Guard Vandal Resistant Shield Vandal Resistant Shield (NEMA-4X)
12-1/8” [30.79cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
LCA-2MRS
Lead-Calcium
LCA-2LD1
AC SPECS
6V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 12 -
6V
12
DC VOLTAGE
-
-
2
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
POWER MAXIMUM
120VAC 277VAC
.1A .05A
7.5W 7.5W
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
ORDERING FORMAT SERIES LCA
LAMP TYPE -2MRS= 6V-5W MR16 halogen -2LD1= 6V-4W MR16 LED
EXAMPLE: LCA-2MRS
72
www.lightalarms.com
AVAILABLE WITH LED LAMP HEADS TYPE
LCA1250 SERIES
CATALOG #
Thermoplastic Housing with High Capacity 12V-50W Lead-Calcium Battery
NOTES
FEATURES
SPECIFICATIONS
Housing • Injection-molded, UV stabilized Thermoplastic body, snap-together design • Two fully adjustable glare-free MR16 lighting heads • Mist white in color, corrosion and scratch-resistant Thermoplastic Mounting • Wall Mount • Keyhole slots and universal knock-outs to mount to any standard 4” junction box Choice of Lamp Types • Two 12W or 20W each MR16 Halogen lamps • Two 4W each MR16 LED lamps Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • 12V-50W Lead-Calcium battery Approvals • UL 924 Standards • UL 94, 5VA flame rated • Damp location listed Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty
Supply and install Lightalarms® LCA1250 Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium battery of 12V-50W. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz, UL 924 and Damp location listed standard. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, red charger monitor LED indicating charging of the battery and push test switch allows for quick operational check of entire system. The cabinet shall be injection-molded, UV stabilized Thermoplastic body, snap together design with two fully adjustable glare-free MR16 lighting heads being corrosion and scratch-resistant in a mist white color. Every LCA1250 Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
DIMENSIONS
Dimensions are approximate and subject to change. 12V-50W 5-7/8” [14.92cm]
For LED lamps warranty, refer to page 162-163 paragraph 3.2 5-1/2” [13.97cm]
ACCESSORIES (Order as a separate item) WG10-L CPS CPS-4X
Wire Guard Vandal Resistant Shield Vandal Resistant Shield (NEMA-4X)
12-1/8” [30.79cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE Lead-Calcium
LCA1250
DC VOLTAGE 12V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 50 36 25 18
2
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
POWER MAXIMUM
120VAC 277VAC
.21A .1A
23W 23W
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
ORDERING FORMAT SERIES LCA1250= 12V-50W
LAMP TYPE -2M12= (2) 12V-12W MR16 Halogen Lamps -2M20= (2) 12V-20W MR16 Halogen Lamps -2LD7= (2) 12V-4W MR16 LED
EXAMPLE: LCA1250-2M12
www.lightalarms.com
73
GRANDE
TM
SERIES
Thermoplastic Housing 6V up to 60W & 12V up to 72W Capacities Lead-Calcium or Nickel-Cadmium battery FEATURES
SPECIFICATIONS
Housing • Injection-molded, UV stabilized Thermoplastic, snap-together design • Corrosion and scratch-resistant, mist white finish or optional black • Snap-on, shock absorbent, clear polycarbonate lens covers • Two fully adjustable glare-free MR16 protected lighting heads
Supply and install Lightalarms® Grande™ Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 6V or 12V, wattages as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize a micro-controller which samples the battery in relation to the ambient temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, and short-circuit protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, Green LED pilot light to indicate AC-ON and a momentary test switch allows for quick operational check of entire system. The cabinet shall be injection-molded, with UV stabilized Thermoplastic body, snap together designand have a corrosion and scratch-resistant finish in a mist white or optional black color with two fully adjustable glare-free MR16 protected polycarbonate covered lighting heads. Units specified with Improved Diagnostics shall continuously monitor every critical function of the unit. If a malfunction occurs, if audible, a high-pitch audible alarm will sound and the green pilot indicator LED located on the unit will change to red and begin to a flash, indicating a fault. If non-audible, only the green pilot indicator LED located on the unit will change to red and begin to a flash, indicating a fault. A detailed diagnostic legend next to the pilot indicator LED provides fault identification as battery, charger circuitry or lamps failure. The micro-controller shall automatically self-test, by simulating a power failure in accordance with NFPA101 Life Safety Code for one minute monthly, monthly, 30 minutes every six months and 90 minutes annually Every Grande™ Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Wall Mount, Ceiling Mount (optional) • Universal knock-outs to mount to any standard 4” junction box Choice of Lamp Type • Two MR16 Halogen lamps • Two MR16 LED lamps Electronics • Micro-controller based charging circuit • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnoses, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Green LED pilot light to indicate AC-ON • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Lead-Calcium battery • 6V or 12V Nickel-Cadmium battery
DIMENSIONS
Dimensions are approximate and subject to change. 12-1/4” [31.11cm]
Approvals • UL 924 Standard • UL 94, 5VA flame rated Thermoplastic housing • Damp location listed (optional) Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty 1
10-5/8” [26.97cm]
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Wire Guard (Wall Mount) Wire Guard (Ceiling Mount)
74
WG1-L WG5-L
www.lightalarms.com
3-7/8” [9.82cm]
TYPE
Designed with aesthetics, ease of installation on wall or ceiling and performance in mind
CATALOG #
NOTES
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
DC VOLTAGE
Lead-Calcium
GRA1
6V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 18 14 9 0
GRA3
6V
30
20
15
10
GRA6
6V
40
30
20
15
GR12A6
6V
60
40
30
20
GR12A7
6V
72
54
36
27
6V
20
15
10
8
GRN25
Nickel-Cadmium
6V
25
18
12
9
GR12N4
6V
40
30
20
15
GR12N50
12V
50
36
24
18
GRN2
2
ORDERING FORMAT # OF HEADS Blank= No heads 2= Two heads
SERIES/CAPACITY Lead-Calcium battery GRA1= 6V-18W GRA3= 6V-30W GRA6= 6V-60W1 GR12A4= 12V-40W GR12A6= 12V-60W GR12A7= 12V-72W Nickel-Cadmium battery GRN2= 6V-20W GRN25= 6V-25W1 GR12N4= 12V-40W GR12N50= 12V-50W1
LAMP TYPE2
2
Not available with Damp Location
M= Mist White B= Black
MR16 LED Lamp LD1= 6V-4W LD7= 12V-4W LD9= 12V-5W LD10= 12V-6W
1
1
HOUSING COLOR
MR16 Halogen Lamp M6= 6V-6W1 M10= 6V or 12V-10W1 M12= 12V-12W1 M20= 12V-20W1
Not available with Damp location No other lamp types available for this Series, for complete information on these lamp types refer to page 101.
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.25A .12A
120VAC 277VAC
.2A .1A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -3CP= 120V Cord & Plug, 3 wire, 3ft long3 -3CP277= 277V Cord & Plug, 3 wire, 3ft long3 -DL= Damp Location4 [50°F -104°F (10°C - 40°C)] -CM= Ceiling Mount -PM= Pendant Mount
1
- ID & IDNA include a time delay feature that can be enabled/disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* -NEX & -NEXRF is CSA-US approved only. Consult your sales representative 3 -3CP & -3CP277 custom lengths available . Consult your sales representative 4 Not available with -NEX & -NEXRF option or GR12N50 & GRN25 models 2
EXAMPLE: 2GRA3M10M
GRANDE™ THERMOPLASTIC FAMILY – The Grande™ Battery Unit is a part of Grande™ family of Thermoplastic emergency lighting products. Giving the same family look and style to a complete emergency lighting and exit sign application.
Grande™ Exit Series p.30
Grande™ Combination Series p.32
www.lightalarms.com
ELF640 (indoor) & ELF650 (outdoor) Remote Fixture p.110-111
75
CAMRAY® LED SERIES Die-Cast aluminum LED Emergency Lighting – Interior or Exterior Capable Nickel-Metal Hydride battery FEATURES
SPECIFICATIONS
Housing Indoor/outdoor suitable for wet location • Die-Cast aluminum housing • Clear, High Impact, UV- Resistant (3” x 1.5”) polycarbonate lens • Four colors are available: off white, black, platinum gray and dark bronze
Supply and install the Camray® Series of LED emergency lighting unit from Lightalarms®. The unit body shall include a back-plate and housing made of Die-Cast aluminum with paint finish color of white, black, platinum gray or dark bronze and a UV- and impact-resistant polycarbonate lens of size: 3” by 1.5”. The back-plate shall have knockouts for wires and wall-mount installation box as well as a threaded hole for rigid conduit entry at the top of the unit. The back-plate shall have a built-in electrical box with wire terminals and snap-on connector. After complete electrical installation of the back-plate the equipment housing shall be installed by a simple push & snap over the back-plate. The emergency lights shall be 4 (four) power-light-emitting diodes (LED) with operational life of minimum 36,000 hours, until 70% of the initial light level (L70). The LED lamps shall have redundant interconnections: eventual failure of one lamp shall allow other LED lamps to function. The unit shall have a dual-voltage input rated: 120/277VAC, 60Hz. The battery charger shall include low voltage disconnect to prevent deep discharge, battery lockout to prevent battery drain prior to energizing the utility power, and brownout protection which will automatically switch unit into emergency mode if the utility power falls below 80% of nominal level. The unit with Nickel-Metal Hydride battery shall be equipped with a microcontroller-based non-audible Improved Diagnostic circuit. The unit shall self-test for one minute every month, 30 minutes every six months and 90 minutes annually. The pilot light shall be integrated with the test button; it shall be a bi-color LED and shall change color from normal green to flashing red when a failure is detected from the battery, charger circuit or lamps. A label located near the pilot light shall describe the diagnostic for each flashing code. When specified, models with dual-mode illumination shall include two separate AC input circuits: for emergency lighting and for normal lighting. When specified, models equipped with photo-switch shall automatically activate the lights only from dusk till dawn, for additional energy savings. The typical ambient illumination for the photo-switch shall be: one foot-candle (to turn-on) and three foot-candles (to turn-off). The unit shall be UL Listed to the UL924 Standard for wet and Damp locations. Unit shall be Lightalarms® catalog number__________________.
Lamp Type • Patent-pending light engine: four power LEDs with redundant connections and very wide beam • 400-640 Lumens • Color temperature: 5000K • Optional forward-throw light distribution, for applications of outdoor Exit discharge (OSHA 1910.36) • Optional high-lumen output: increase 25-50% additional level of illumination • Optional dual-mode operation: normal and emergency LED lighting with separate AC inputs Electronics • Automatic, temperature compensated • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics • Nickel-Metal Hydride battery units are standard with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code minimum 1 minute every 30 days, 30 minutes every 6 months and 90 minutes annually. For complete information refer to page 8. Controls • Integrated test button and LED optical pipe pilot light • Optional photo-switch: dusk-to-dawn control of normal lighting • Optional remote test: infrared remote control (keyboard ordered separately) • Optional time delay: choice of 5, 10 or 15 minutes
DIMENSIONS
Dimensions are approximate and subject to change.
3” [7.5 cm]
Sealed Maintenance-Free Battery • High-Temperature Rated, Nickel-Metal Hydride technology battery Approval • UL 924 Standards for wet, cold and Damp locations • Nema-3R rated for indoor/outdoors cold-weather wet and Damp locations: -20... 40°C (-4.... 104°F) Warranty (subject to proper installation and maintenance) • Unit has a five year limited warranty (excluding lamps and fuses)1 • Nickel-Metal Hydride battery has a five year full, plus five year pro-rata warranty 1
For LED lamps warranty, refer to page 168 paragraph 3.2
76
www.lightalarms.com
6-5/8” [16.8cm]
3” [7.5 cm]
9-1/2” [24 cm]
Mounting • Wall Mount • 1/2” rigid conduit entry provision on the top of the unit • Universal knock-outs to mount to any standard 4” junction box • Patent-pending design for easy installation: wall-mount back-plate includes electrical wire box with snap-on connector
Window for photo-switch (optional)
LED LIGHT SOURCE NORMALLY-ON AND EMERGENCY BACK-UP
NEMA-3R
TYPE
Performance, low-profile, modern slim look emergency unit with optional dual mode normally-on and photo-cell activated models
CATALOG #
NOTES
PHOTOMETRY PERFORMANCE
Whether installed indoors or outdoors, with spacing measurements for a single unit or between two units center-to-center, the Camray® Series LED delivers a stable and consistent illumination making it easy to specify in a wide range of applications. The outstanding spacing of illumination ranges from 50 to 70 feet for standard units (wide beam) and from 40 to 50 feet with the forward-throw beam option.
AVERAGE OF 1 FOOT-CANDLE
MINIMUM OF 1 FOOT-CANDLE
TABLE A: SPACING FOR NFPA101 (AVERAGE = 1FC, SEE NOTE) MODEL TYPE
TABLE B: SPACING FOR MINIMUM ILLUMINATION = 1FC
MOUNTING LUMEN COLOR WIDTH X LENGTH (FT) HEIGHT TEMPERATURE SINGLE UNIT CENTER-TO-CENTER
MODEL TYPE
MOUNTING LUMEN HEIGHT
COLOR TEMPERATURE
WIDTH X LENGTH (FT) SINGLE UNIT CENTER-TO-CENTER
Standard
9’
400
6’ X 50’
6’ X 50’
Standard
9’
400
4’ x 28’
4’ x 32’
With option -H
11’
550
6’ X 60’
6’ X 60’
With option -H
11’
550
4’ x 32’
4’ x 40’
With option -FT
12’
460
4’ x 22’
—
With option -FT
12’
460
6’ X 40’
—
With option -FTH
15’
640
4’ x 27’
—
With option -FTH
15’
640
6’ X 50’
—
5000K
3’ X 70’
5000K
Indoor reflectance: 80/50/20 and 10-ft wide corridor. Outdoor reflectance: 0/30/10
Note: The illumination level meets ALL the requirements of the Life Safety Code (NFPA 101): 1) Average of 1 foot-candle or more 2) Minimum at any point of 0.1 foot-candle or more 3) Maximum-to-minimum illumination uniformity ratio of 40:1 or less
PHOTOMETRIC 12’
22’ 1fc average
50’
28’
40’
9’ 6’ 6’
POWER CONSUMPTION MODEL
AC INPUT(S): 120/277VAC NORMAL LIGHTING CURRENT (MAX)
DC INPUT
EMERGENCY LIGHTING
POWER (MAX.)
CURRENT (MAX)
6-12V1 POWER (MAX.)
POWER (MAX.)
AC, 2AC, ACDC, DC
0.12/0.08A
12W
0.11/0.08A
12W
8W
All above, -H
0.18/0.11A
18W
0.18/0.11A
18W
14W (6VDC only)
ACSD, SD, SD-H
0.12/0.06A
12W
0.05/0.02A
5W
0.15/0.07A
16W
0.22/0.10A
24W
SD-CW
—
—
ACSD-CW-P, -FT
N/A
1
1
ORDERING FORMAT - BATTERY UNIT SERIES CAM= Camray LED
MODEL
Note: Only unswitched AC input; normal lighting with photo-switch or remote control
COLOR
Nickel-Metal Hydride Battery Units (standard with Self-Diagnostics) SD= Self-Powered Only (-4°F + 122°F)(-20°C + 50°C) ACSD= Dual-Mode AC/Self-Powered (-4°F + 104°F) (-20°C + 40°C)
B= Black DB= Dark bronze OW= Off white PG= Platinum gray
N/A1
OPTIONS -CW= Cold weather (-40°F - 86°F) (-40°C - 30°C); not available with option -H -FT= Forward throw lighting -H= High lumen output (32... 86°F / 0... 30°C; model SD only) 1
-P= Photo-switch, (model models ACSD only) -T1= Time delay: 5 minutes (models ACSD, SD only) -T2= Time delay: 10 minutes (models ACSD, SD only) -T3= Time delay: 15 minutes (models ACSD, SD only) -RC= Remote control - infrared1
With -RC option, order the remote control keypad (TB-RC1-L) separately
EXAMPLE: CAMSDOW-RC
ORDERING FORMAT - REMOTE FIXTURE SERIES CAM= C amray LED
MODEL AC= AC-Only (-40°F + 122°F) (-40°C + 50°C) 120/277V 2AC= AC-Only two Circuit 120/120V or 277/277V (-40°F + 122°F) (-40°C + 50°C) ACDC= AC/6-12VDC (-40°F + 122°F) (-40°C + 50°C) DC= 6-12VDC Only (-40°F + 122°F) (-40°C + 50°C)
COLOR B= Black DB= Dark bronze OW= Off white PG= Platinum gray
OPTIONS -FT= Forward throw lighting -H= High lumen output (maximum 86°F/30°C); not available ACSD) -P= Photo-switch, (model models AC, AC/DC only ) -RC= Remote control - infrared1 1
With -RC option, order the remote control keypad (TB-RC1-L) separately
EXAMPLE: CAMACOW-RC
www.lightalarms.com
77
MC SERIES Steel Housing 6V up to 36W & 12V up to 50W Capacities Lead-Calcium or Nickel-Cadmium battery
Shown with ELF3 heads and LED Lamps
FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing with hinged front access panel • Corrosion-resistant baked enamel mist white finish standard, black optional • Provision for mounting up to 2 lighting heads • Various choices of lighting head styles and lamp types Mounting • Ceiling or Wall Mount • 1/2” conduit knock-outs, rear keyhole slots and universal knock-outs to mount to any standard 4” junction box Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnoses, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Lead-Calcium battery • 6V or 12V volt, Nickel-Cadmium battery Approvals • UL 924 Standard Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty
Supply and install Lightalarms® MC Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 6V or 12V, of wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to its temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be 20 gauge steel with a front hinged panel. Unit shall have 1/2” conduit knock-outs, rear keyhole slots and universal knock-outs to mount to any standard 4” junction box with provision for mounting up to 2 heads on top of cabinet. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only LED status indicator illuminate alerting of the unit malfunction. The microcontroller shall automatic self-test, by simulating a power failure in accordance with NFPA101 Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually Every MC Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Wire Guard (ELF2, ELF3 and DR1130 Heads) Wire Guard (ELF622, ELF623 and ELF645 Heads)
WG1 WG2
DIMENSIONS
Dimensions are approximate and subject to change. Shown with ELF2 heads
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
ELF2
ELF622
ELF623
X
X
X
X
X
X
(pg.134)
(pg.129)
Wedge Based Incandescent
X
BI-Pin Halogen
X
PAR36 Sealed Beam Incand.
X
PAR36 Sealed Beam Halogen
X
ELF3
(pg.130)
DR1130 (pg.128)
(pg.132)
9-5/8” [24.44cm] 5-1/2” [13.97cm]
X X
MR16 Halogen
X
X
MR16 LED
X
X
78
(pg.131)
12-3/4” [32.38cm]
www.lightalarms.com
3-3/8” [8.57cm]
TYPE
Incorporates maximum versatility in head style and lamp choices with performance, ease of installation, all into a compact unit
CATALOG #
NOTES
POWER CONSUMPTION / UNIT RATING CHART SERIES
ELF2
ELF3
DR1130
ELF622
ELF623
Head Style Suffix: /Blank
/ELF2
/ELF3
/DR1130
/ELF622
/ELF623
DC SPECS BATTERY TYPE Lead-Calcium
MCG
Available Head Style Choices: ELF645
MCG1
AC SPECS
6V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 18 12 0 0
6V
20
DC VOLTAGE
15
12
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
POWER MAXIMUM
120VAC 277VAC
.2A .08A
24W
0
MCG2
6V
27
18
15
9
MCG3
6V
30
20
18
10
MCG4
6V
36
27
20
12
MCG5
6V
40
30
24
15
MC121
12V
36
27
20
12
277VAC
.12A .24A
30W
6V
20
18
12
0
120/277VAC
.2A/.08A
24W
MC12N1
12V
36
24
15
12
120VAC
.24A
MC12N2
12V
50
36
24
18
277VAC
.12A
Nickel-Cadmium
MCN1
2
ORDERING FORMAT # OF HEADS 0= No Heads 1= One Head 2= Two Heads
SERIES/CAPACITY Lead-Calcium battery MCG= 6V-18W MCG1= 6V-20W MCG2= 6V-27W MCG3= 6V-30W MCG4= 6V-36W MC12G1= 12V-20W Nickel-Cadmium battery* MCN1= 6V-20W* MC12N1= 12V-36W* MC12N2= 12V-50W*
HEAD STYLE
LAMP TYPE
/Blank= ELF645 (PAR36, Plastic) /ELF622= ELF622 (PAR36, Metal) /ELF2= ELF2 (PAR18, Plastic) /ELF3= ELF3 (MR16, Plastic) /DR1130= DR1130 (MR16, Metal) /ELF623= ELF623 (Square, Plastic)
Add lamp suffix to indicate lamp type, voltage and wattage. For available Lamp Types within a specified Head Style, refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 134 with ELF622, page 131 with ELF2, page 129 with ELF3, page 130 with DR1130, page 128 with ELF623, page 132
30W
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
HOUSING COLOR -M= Mist White -B= Black
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -DS= Lamp Disconnect Switch -VS= Vandal-Resistant Screws -FM= Front Mounted heads -3CP= 120V Cord & Plug, 3 wire, 3ft long3
Lamp Type MUST: 1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min. 1
- ID & -IDNA include a time delay feature that can be enabled/disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* 2 Consult your sales representative 3 -3CP custom lengths available. Consult your sales representative
* Not available with sealed beams ______ lamps
EXAMPLE: 2MCG4/ELF3-M6-M-ID
www.lightalarms.com
79
Shown with ELF645 heads
PG & P12G SERIES Steel Housing 6V up to 54W & 12V-54W Capacities Lead-Calcium battery FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing with removable front access panel • Corrosion-resistant baked enamel mist white finish standard, black optional • Provision for mounting up to 3 lighting heads • Various choices of lighting head styles and lamp types Mounting • Wall Mount • 1/2’”conduit knock-outs, rear keyhole slots and universal knock-outs to mount to any standard 4” junction box Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit • Input: 120/277 VAC, 60Hz 0.3/0.15A Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnostics, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Lead-Calcium battery Approvals • UL 924 Standard Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus five year pro-rata warranty
Supply and install Lightalarms® PG, P12G Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium battery of 6V or 12V, of wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to its temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be 20 gauge steel with a removable front panel. Unit shall have 1/2” conduit knock-outs, rear keyhole slots and universal knockouts to mount to any standard 4” junction box with provision for mounting up to 3 heads on top of cabinet. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code for a minimum of one minute monthly, 30 minutes every six months and 90 minutes annually Every PG, P12G Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) WG2-L MP-PQA
Wire Guard Mounting Platform
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
Wedge Based Incandescent Bi-Pin Halogen PAR36 Sealed Beam Incand. PAR36 Sealed Beam Halogen MR16 Halogen MR16 LED
80
ELF2
(pg.108)
(pg.105)
X X X X
X X
ELF3
(pg.106)
DR1130 (pg.104)
ELF623
(pg.107)
X X
X X
X X
www.lightalarms.com
TYPE
Combines reliability, versatility, performance into an aesthetically pleasing design
CATALOG #
NOTES
Shown with ELF 3 heads and LED Lamps
DIMENSIONS
Available Head Style Choices: Head Style Suffix:
Dimensions are approximate and subject to change.
ELF645 /Blank
ELF645
14-5/8” 14-5/8” [37.14cm]
ELF2 /ELF2
ELF3 /ELF3
DR1130 /DR1130
ELF623 /ELF623
ELF2/ELF3
13” 13” [33.02cm] 8-1/2” 8-1/2” [21.59cm]
3-1/8” 3-1/8” [7.93cm]
12-3/4” 12-3/4” [32.38cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS
AC SPECS
6V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 18 15 0 0
PG2
6V
54
36
27
18
P12G1
12V
54
36
27
18
BATTERY TYPE Lead-Calcium
PG1
DC VOLTAGE
2
ORDERING FORMAT # OF HEADS 0= No head 1= One head 2= Two heads 3= Three heads
SERIES/CAPACITY PG1= 6V-18W PG2= 6V-54W P12G1= 12V-54W
HEAD STYLE
LAMP TYPE
/Blank= ELF645 (PAR36, Plastic) /ELF2= ELF2 (PAR18, Plastic) /ELF3= ELF3 (MR16, Plastic) /DR1130= DR1130 (MR16, Metal) /ELF623= ELF623 (Square, Plastic)
Add lamp suffix to indicate lamp type, voltage and wattage. For available Lamp Types within a specified Head Style, refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 108 with ELF2, page 105 with ELF3, page 106 with DR1130, page 104 with ELF623, page 107 Lamp Type MUST: 1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min.
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.25A .15A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
HOUSING COLOR -M= Mist White -B= Black
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -A= Ammeter3 -V= Voltmeter3 -PTS= Photocell Test Switch -DS= Lamp Disconnect Switch -VS= Vandal-Resistant Screws -3CP= 120V Cord & Plug, 3 wire, 3ft long4 - ID & -IDNA include a time delay feature that can be enabled/disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* 2 Consult your sales representative 3 -A & -V not available with -ID, -IDNA, -NEX, -NEXRF option 4 -3CP custom length available. Consult your sales representative 1
EXAMPLE: PG1/LH5-M
www.lightalarms.com
81
PN & P12N SERIES Steel Housing 6V-25W & 12V up to 72W Capacities Nickel-Cadmium battery FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing with removable front access panel • Corrosion-resistant baked enamel mist white finish standard, black optional • Provision for mounting up to 3 lighting heads • Various choices of lighting head styles, head mounting and lamp types
Supply and install Lightalarms® PN, P12N Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free NickelCadmium battery of 6V or 12V of volt wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be 20 gauge steel with a removable front panel. Unit shall have 1/2” conduit knock-outs, rear keyhole slots and universal knockouts to mount to any standard 4” junction box with provision for mounting up to 3 heads on top of cabinet. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101 Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually Every PN, P12N Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Wall Mount • 1/2” conduit knock-outs, rear keyhole slots and universal knock-outs to mount to any standard 4” junction box Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit • Input: 120/277 VAC, 60Hz 0.3/0.15A Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Nickel-Cadmium battery Approvals • UL 924 Standard Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding LED lamps and fuses)1 • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty 1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) WG2-L WG3-L MP-PQA
Wire Guard (A cabinet) Wire Guard (B cabinet) Mounting Platform
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
Wedge Based Incandescent Bi-Pin Halogen MR16 Halogen MR16 LED
82
ELF2
(pg.108)
(pg.105)
X X
X X
ELF3
(pg.106)
DR1130 (pg.104)
ELF623 (pg.107)
X X X
X
X
X
www.lightalarms.com
TYPE
Combines reliability, versatility, performance into a aesthetically pleasing design
CATALOG #
NOTES
DIMENSIONS
Available Head Style Choices: ELF645 Head Style Suffix: /Blank
Dimensions are approximate and subject to change.
ELF645
ELF2 /ELF2
ELF3 /ELF3
DR1130 /DR1130
ELF623 /ELF623
ELF2/ELF3
25W and 50W units use A Cabinet dimensions 72W unit use B Cabinet dimensions
CABINET
DIMENSIONS a
b
c
d
A
14-5/8” (37.14cm) // 13” (33.02cm)
12-3/4” (32.38cm)
3-1/8” (7.93cm)
8-1/2” (21.59cm)
B
16-3/8” (41.59cm) // 16-1/8” 14-3/4” (37.46cm) (40.95cm)
5-7/16” (13.81cm)
10-1/4” (26.03cm)
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS
AC SPECS
6V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 25 20 14 10
PN2
6V
50
36
25
18
P12N2
12V
72
60
50
38
BATTERY TYPE Nickel-Cadmium
PN1
DC VOLTAGE
2
ORDERING FORMAT # OF HEADS 0= No head 1= One head 2= Two heads 3= Three heads
SERIES/ CAPACITY PN1= 6V-25W P12N1= 12V-50W P12N2= 12V-72W
HEAD STYLE
LAMP TYPE
/Blank= ELF645 (PAR36, Plastic) /ELF2= ELF2 (PAR18, Plastic) /ELF3= ELF3 (MR16, Plastic) /DR1130= DR1130 (MR16, Metal) /ELF623= ELF623 (Square, Plastic)
Add lamp suffix to indicate lamp type, voltage and wattage. For available Lamp Types within a specified Head Style, refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 108 with ELF2, page 105 with ELF3, page106 with DR1130, page 104 with ELF623, page 107 Lamp Type MUST: 1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min. 3) Sealed Beams not compatible with Nickel-Cadmium battery
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.3A .15A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
HOUSING COLOR -M= Mist White -B= Black
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -A= Ammeter3 -V= Voltmeter3 -PTS= Photocell Test Switch -DS= Lamp Disconnect Switch -VS= Vandal-Resistant Screws -3CP= 120V Cord & Plug, 3 wire, 3ft long4
- ID & -IDNA include a time delay feature that can be enabled/ disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* 2 Consult your sales representative 3 -A & -V not available with -ID, -IDNA, -NEX, -NEXRF option 4 -3CP custom lengths available. Consult your sales representative 1
EXAMPLE: 2P12N2/L9-M-ID
www.lightalarms.com
83
PQ & P12Q SERIES
Shown with ELF645 heads
Steel Housing 6V up to 200W & 12V up to 200W Capacities Lead-Calcium battery
FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing with removable front access panel • Corrosion-resistant baked enamel mist white finish standard, black optional • Provision for mounting up to 3 lighting heads • Various choices of lighting head styles and lamp types Mounting • Wall Mount • 1/2” conduit knock-outs, rear keyhole slots and universal knock-outs to mount to any standard 4” junction box Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnostics, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Lead-Calcium battery Approvals • UL 924 Standard Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty
Supply and install Lightalarms® PQ, P12Q Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Nickel-Cadmium battery of 6V or 12V of wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be 20 gauge steel with a removable front panel. Unit shall have 1/2” conduit knock-outs, rear keyhole slots and universal knockouts to mount to any standard 4” junction box with provision for mounting up to 3 heads on top of cabinet. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101 Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually Every PQ, P12Q Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Wire Guard Mounting Platform (B cabinet) Mounting Platform (C cabinet)
84
WG3-L MP-PQA MP-PQB
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
Wedge Based Incandescent Bi-Pin Halogen PAR36 Sealed Beam Incand. PAR36 Sealed Beam Halogen MR16 Halogen MR16 LED
www.lightalarms.com
ELF2
(pg.108)
(pg.105)
X X X X
X X
ELF3
(pg.106)
DR1130 (pg.104)
ELF623 (pg.107)
X X
X
X
X
X
TYPE
Performance along with the extra battery capacity to power up to two 50W mounted heads or numerous matching remote heads
CATALOG #
NOTES
shown with ELF3 heads and LED lamps
DIMENSIONS
ELF645 /Blank
Available Head Style Choices: Head Style Suffix:
Dimensions are approximate and subject to change. ELF645
ELF2 /ELF2
ELF3 /ELF3
DR1130 /DR1130
ELF2/ELF3 100W unit use B Cabinet dimensions 200W unit use C Cabinet dimensions
CABINET
DIMENSIONS a
b
c
d
B
16-3/8” (41.59cm)// 14-3/4”
16-1/8” (40.95cm)
5-7/16” (13.81cm)
10-1/4” (26.03cm)
C
18-3/8” (46.67cm)// 16 3/4” (42.54cm)
16-1/2” (41.91cm)
7-1/4” (18.41cm)
12-1/4” (32.38cm)
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE Lead-Calcium
PQ2
DC VOLTAGE 6V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 100 75 50 36
PQ3
6V
200
150
100
72
P12Q1
12V
100
75
50
36
P12Q2
12V
200
150
100
72
2
ORDERING FORMAT # OF HEADS 0= No heads 1= One head 2= Two heads 3= Three heads
SERIES/CAPACITY PQ2= 6V-100W PQ3= 6V-200W P12Q1= 12V-100W P12Q2= 12V-200W
HEAD STYLE /Blank= ELF645 (PAR36, Plastic) /ELF2= ELF2 (PAR18, Plastic) /ELF3= ELF3 (MR16, Plastic) /DR1130= DR1130 (MR16, Metal)
LAMP TYPE Add lamp suffix to indicate lamp type, voltage and wattage. For available Lamp Types within a specified Head Style, refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 108 with ELF2, page 105 with ELF3, page 106 with DR1130, page 104 with ELF623, page 107 Lamp Type MUST: 1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min.
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.3A .15A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
COLOR -M= Mist White -B= Black
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -A= Ammeter3 -V= Voltmeter3 -DS= Lamp Disconnect Switch -VS= Vandal-Resistant Screws -3CP= 120V Cord & Plug, 3 wire, 3ft long4
1
-ID & -IDNA include a time delay feature that can be enabled/ disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD*. Not available with P12Q2 series
2
Consult your sales representative
3
- A & -V not available with -ID, -IDNA, -NEX, -NEXRF option -3CP & -3CP277 custom lengths available. Consult your sales representative
4
EXAMPLE: 2P12Q1/DR1130M50-M
www.lightalarms.com
85
S12E & S24E SERIES
shown with ELF645 heads
Steel Housing 12V up to 400W & 24V-400W Capacities Lead-Calcium battery
FEATURES
SPECIFICATIONS
Housing • 20 gauge steel housing with removable front access panel • Corrosion-resistant baked enamel gray finish standard, mist white and black optional • Provision for mounting up to 3 lighting heads • Various choices of lighting head styles and lamp types Mounting • Wall Mount • 1/2” conduit knock-outs, rear keyhole slots and universal knock-outs to mount to any standard 4” junction box Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit • Input: 120/277 VAC, 60Hz 0.3/0.15A Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall self-test, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnoses, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 12V or 24V Lead-Calcium battery Approvals • UL 924 Standard Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty
Supply and install Lightalarms® S12E, S24E Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium battery of 12V or 24V of wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be 20 gauge steel with a removable front panel. Unit shall have 1/2” conduit knock-outs, rear keyhole slots and universal knockouts to mount to any standard 4” junction box with provision for mounting up to 3 heads on top of cabinet. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101 Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually. Every S12E, S24E Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Wire Guard (S12E4) Wire Guard (S12E5/S12E6/S24E4) Mounting Platform (S12E4) Mounting Platform (S12E5/S12E6/S24E4) Mounting Bracket (S12E4/S24E4)
86
WG3-L WG4-L MP-A MD-12 MB-A
HEAD STYLE WITH LAMP TYPE CHOICES LAMP TYPE
HEAD STYLE ELF645
Wedge Based Incandescent BI-Pin Halogen PAR36 Sealed Beam Incand. PAR36 Sealed Beam Halogen MR16 Halogen MR16 LED
www.lightalarms.com
ELF2
(pg.108)
(pg.105)
X X X X
X X
ELF3
(pg.106)
DR1130 (pg.104)
ELF623 (pg.107)
X X
X
X
X
X
TYPE
Suited for applications requiring high capacity for multiple remote capabilities or extended operating times
CATALOG #
NOTES
DIMENSIONS
Available Head Style Choices: Head Style Suffix:
Dimensions are approximate and subject to change.
ELF645 /Blank
ELF2 /ELF2
ELF3 /ELF3
DR1130 /DR1130
200W unit use C Cabinet dimensions 300W and 400W unit use D Cabinet dimensions
CABINET
DIMENSIONS a
b
c
d
C
18-3/8” (46.67cm)
16-1/2” (41.91cm)
7-1/4” (18.41cm)
12-1/4” (32.38cm)
D
18-3/8” (46.67cm)
27” (68.58cm)
7-1/4” (18.41cm)
12-1/4” (32.38cm)
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS
AC SPECS
12V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 200 150 107 85
S1245
12V
300
225
165
127
S12E6
12V
400
300
214
170
S24E4
24V
400
300
120
60
BATTERY TYPE Lead-Calcium
S12E4
DC VOLTAGE
2
ORDERING FORMAT # OF HEADS 0= No heads 1= 1 head 2= 2 heads 3= 3 heads
SERIES/ CAPACITY
HEAD STYLE
S12E4= 12V-200W1 S12E5= 12V-300W S12E6= 12V-400W S24E4= 24V-400W
/Blank= ELF645 (PAR36, Plastic) /ELF2= ELF2 (PAR18, Plastic) /ELF3= ELF3 (MR16, Plastic) /DR1130= DR1130 (MR16, Metal)
LAMP TYPE Add lamp suffix to indicate lamp type, voltage and wattage.
CURRENT MAXIMUM
120VAC 277VAC
.3A .15A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
FINISH -G= Gray -M= Mist White -B= Black
For available Lamp Types within a specified Head Style, refer to that Head Style page for proper lamp suffix with Blank (ELF645), page 108 with ELF2, page 105 with ELF3, page 106 with DR1130, page 104 with ELF623, page 107
UNITS DUAL VOLTAGE2
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1 -IDNA= Improved Diagnostics (non audible)1 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -A= Ammeter2 -V= Voltmeter2 -DS= Lamp Disconnect Switch -VS= Vandal-Resistant Screws -3CP= 120V Cord & Plug, 3 wire, 3ft long3
Lamp Type MUST:
1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min. - ID & -IDNA include a time delay feature that can be enabled/ disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* 2 -A & -V not available with -ID, -IDNA, -NEX, -NEXRF option 3 -3CP & -3CP277 custom lengths available. Consult your sales representative 1
EXAMPLE: 2S12E4/L25-G
www.lightalarms.com
87
FG, F12G, FN, F12N & F24N SERIES Weather & Corrosion-Resistant Housing 6V up to 100W, 12V up to 110W & 24V-100W Capacities Lead-Calcium or Nickel-Cadmium battery FEATURES
SPECIFICATIONS
Housing • Weather and Corrosion Resistant • Molded gray high impact Thermoplastic case with hinged front access panel • Oil, water and dust-tight construction, stainless steel hardware, single piece neoprene gasket and vented battery compartment • Provision for mounting up to 2 lighting heads • Various choices of lamp types
Supply and install Lightalarms® FG, F12G, FN, F12N, F24N Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium or Nickel-Cadmium battery of 6V, 12V or 24V, of wattage as specified in the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with sealed dust-tight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be molded gray high impact Thermoplastic case with hinged front access panel featuring oil, water and dust-tight construction, stainless steel hardware, single piece neoprene gasket and vented battery compartment. Includes mounting feet and provision for mounting up to 2 heads on front access panel. Units specified with Improved Diagnostics (audible or non-audible) will continuously monitor every critical function of the unit, attached remote lighting heads and/or attached AC/DC Exit Signs. Operational status of the battery, charger and lamps are indicated by individual LED status indicators. Once a malfunction is detected, if audible, a high-pitch audible alarm will sound, and the appropriate LED status indicator will illuminate alerting of the unit malfunction. If non-audible, only the LED status indicator will illuminate alerting of the unit malfunction. The microcontroller shall automatically self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code for one minute monthly, 30 minutes every six months and 90 minutes annually. Every FG, F12G, FN, F12N, F24N Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Wall Mount; external mounting feet are provided Electronics • Automatic, temperature compensated, pulse-type charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics option • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnoses, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red charger monitor LED indicates charging of the battery • Amber AC-ON LED indicates AC power is on • Momentary test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V, Lead-Calcium battery • 6V, 12V or 24V Nickel-Cadmium battery Approvals • UL 924 Standard Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Lead-Calcium battery has a three year full, plus three year pro-rata warranty • Nickel-Cadmium battery has a five year full, plus five year pro-rata warranty 1
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Wire Guard
88
WG3-L
www.lightalarms.com
TYPE
Designed for weather-resistant and industrial applications, especially for corrosive atmospheres
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 10-3/8”
13-3/8” 13-3/8” [33.97cm]
13” 13” [33.02cm]
13-3/8”
8” [20.32cm] 8”
13”
5”
8” 11-5/8”
11-5/8” 11-5/8”
[29.52cm]
10-3/8” 10-3/8” [26.36cm]
5” 5” [12.75cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE Lead-Calcium
FG1
DC VOLTAGE 6V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 50 36 25 12
FG2
6V
100
75
50
24
F12G1
12V
50
36
25
12
F12G2
12V
100
75
50
24
12V
50
36
18
10
Nickel-Cadmium
F12N1 F12N2
12V
100
75
37
20
F24N2
24V
100
75
37
20
2
ORDERING FORMAT # OF HEADS 0= No head 1= One head 2= Two heads
SERIES/CAPACITY
LAMP TYPE
Lead-Calcium battery FG1= 6V-50W FG2= 6V-100W F12G1= 12V-54W F12G2= 12V-100W
Add lamp suffix to indicate lamp type, voltage and wattage.
Nickel-Cadmium battery F12N1= 12V-50W F12N2= 12V-100W F24N2= 24V-100W
Lamp Type MUST: 1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min.
For available Lamp Types within an ELF647 Head Style Weather-Proof, refer to that Head Style page for proper lamp suffix see page 109
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.3A .15A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
OPTIONS Blank= No Options -ID= Improved Diagnostics (audible)1, 2 -IDNA= Improved Diagnostics (non audible)1, 2 -NEX= Nexus® Wired Compatible3 -NEXRF= Nexus® Wireless Compatible3 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -A= Ammeter4 -V= Voltmeter4 -DS= Lamp Disconnect Switch -VS= Vandal-Resistant Screws -3CP= 120V Cord & Plug, 3 wire, 3ft long5
- ID & -IDNA include a time delay feature that can be enabled/disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* -ID & -IDNA not available with F12N2 & F24N2 3 Consult your sales representative 4 -A & -V not available with -ID, -IDNA, -NEX, -NEXRF option 5 -3CP & -3CP277 custom lengths available . Consult your sales representative 1
2
EXAMPLE: 2F12G1/L9-ID
www.lightalarms.com
89
SEVERE
TM
V SERIES
NEMA-4X, NSF, Vandal-Resistant Housing 6V-18W & 12V up to 60W Capacities Lead-Calcium, Nickel-Cadmium or Nickel-Metal Hydride battery FEATURES
SPECIFICATIONS
Housing • NEMA 4X; suited for industrial, hose down, food processing and harsh environments • Die-cast aluminum back plate with internal Thermoplastic housing • Vandal-resistant UV stabilized polycarbonate cover • Fully gasketed between die-cast back plate and polycarbonate cover • Phillips head or Tamper-proof screws • Available in three colors: white, black or gray Mounting • Wall Mount on a 4” junction box, not intended for ceiling mount • Universal bracket accessory available for beams or superstrut mounting Choice of Lamp Type • Two 6V or 12V-6W, 12W or 20W each MR16 Halogen lamps • Two 6V or 12V-4W, 12V-5W or 12V-6W each MR16 LED lamps Electronics • Standard, fully automatic Improved Diagnostic Micro-controller based circuitry detects and indicates any malfunction or failure of the battery, charger circuitry, or lamps • External LED signals a service alarm, four internal diagnostic LED’s • Incorporates battery lockout and brownout circuits, and low voltage disconnection, protects the unit from over-current, short-circuit, and reverse polarity Improved Diagnostics • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code one minute monthly, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. NEXUS® option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101 Life Safety Code for a minimum of 30 seconds monthly, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature real-time diagnoses, and provide the exact fixture location while notifying service personnel of the status of the fixture via email. For complete information refer to page 4-5. Controls • Red LED indicates if unit requires service • Green AC-ON LED indicates AC power is on • Magnetic test switch allows for quick operational check of entire system Choice of Sealed Maintenance-Free Battery • 6V or 12V Lead-Calcium battery • 12V Nickel-Cadmium battery listed for Damp and wet locations (+10°C to +40°C/+50°F to +104°F) • 12V Nickel-Metal Hydride battery Approvals • UL 924 Standard • UL listed for wet and Damp locations • UL listed for cold weather (-40°C to +40°C/-40°F to +104°F) option • NSF certified for use in food processing plants • NEMA 4X Rated Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding LED lamps and fuses)1 • Lead-Calcium battery, three year full, plus three year pro-rata warranty • Nickel-Cadmium battery, five year full, plus five year pro-rata warranty • Nickel-Metal Hydride battery, five year full, plus five year pro-rata warranty
Supply and install Lightalarms®, Severe™ V Series Emergency Battery Unit. The unit shall be a self-contained fixture including a sealed maintenance-free 6V or 12V, Lead-Calcium or Nickel-Cadmium, or 12V, Nickel-Metal Hydride battery with wattage as specified on the unit rating chart. The unit shall be supplied with an Improved Diagnostic Micro-controller board rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz and be UL 924 listed. The charger shall continuously recharge the battery. When the battery is at full capacity, the charger will periodically pulse-charge the battery in stand-by mode. This pulse-type charger promotes long battery life and reduces the potential for grid corrosions. Its charge voltage is factory set to +/-1% tolerance and temperature compensated. The charger incorporates Lockout and Brownout Circuits, and Low Voltage Disconnection. It protects the unit from over-current, short-circuit, and reverse polarity. This unit shall self-test for 1 minute monthly, 30 minutes on the 6th month and 90 minutes every 12 months. The unit shall be capable of full recharge in compliance with UL specifications. The unit shall be furnished with a magnetic test switch. A “Service Required” lamp shall be located near the test switch and flash when a fault is detected. A LED-based diagnostic display shall be located inside the equipment and shall identify the source of failure (battery, charger, circuitry, or lamps). The unit shall include a die-cast aluminum back plate, an internal housing made of industrial grade Thermoplastic, a neoprene gasket and a UV stabilized polycarbonate lens. The front of the unit shall be protected with a clear cover constructed of heavy-duty vandal-resistant, UV stabilized polycarbonate lens, with a gasket between the lens and back plate, attached with Phillips head or tamper-proof screws. Emergency lights shall be fully adjustable and equipped with high efficiency MR16 Halogen or MR16 LED lamps as specified. The unit shall be NEMA-4X rated and designed specifically for high abuse areas, wet and Damp locations. Unit shall be Lightalarms® catalog number__________________.
1
UNIVERSAL MOUNTING BRACKETS 9” 1/4” Bolts (Not Included)
PMK KIT (screws included)
Beam Mounting
Superstrut Mounting
The Severe™ XV Series Battery Unit is part of the Severe™ family of NEMA-4X rated emergency lighting products. The Severe™ family offers complete emergency lighting solutions for commercial and industrial environments where protecting against humidity, dust, water infiltration and the risk of vandalism are specification criteria.
For LED lamps warranty, refer to page 168 paragraph 3.2
ACCESSORIES (Order as a separate item) Bit for Tamper-proof Screws Universal Mounting Bracket
90
690.0454-L PMK-L
Severe™ XV Exit Series p.40
www.lightalarms.com
Severe™ XV Combo Series p.42
Severe™ ELF650 Remote Series p.111
NEMA-4X TYPE
For heavy-duty industrial environments, such as hose-down, food processing, or vandal-prone areas.
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 5-3/4” [14.60cm]
17-3/4” [45.08cm]
7” [17.78cm]
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
VG1
Lead-Calcium
DC VOLTAGE 6V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 18 12 -
V12G1
12V
24
16
12
-
V12G2
12V
36
24
20
14
V12G3 V12G1-CW4 V12G2-CW4 V12N1
With cold weather option Nickel-Cadmium
V12N2 V12H1
Nickel Metal Hydride
12V
54
36
27
20
12V
24
NOTE 3
-
-
12V
36
NOTE 3
-
-
12V
24
16
12
-
12V
40
30
20
15
12V
60
40
30
20
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
POWER MAXIMUM
120VAC 277VAC
.2A .11A
20W 20W
120/227VAC
120VAC 277VAC
2
ORDERING FORMAT # OF HEADS 2= Two heads
SERIES
LAMP TYPE1
HOUSING COLOR
Lead-Calcium battery VG1= 6V-18W V12G1= 12V-24W V12G2= 12V-36W V12G3= 12V-54W
MR16 Halogen Lamp M6= 6V-6W M10= 12V-10W M12= 12V-12W MH20= 12V-20W High Output
Nickel-Cadmium battery V12N1= 12V-24W V12N2= 12V-40W
MR16 LED Lamp LD1= 6V-4W LD7= 12V-4W LD9= 12V-5W LD10= 12V-6W
Nickel-Metal Hydride battery V12H1= 12V-60W
-B= Black -G= Gray -M= White
.4A/.3A
60W
.7A/4A
100W
.2A .11A
20W 20W
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type 3 Dependent on lower ambient temperatures
STANDARD DIAGNOSTICS -D= Improved Diagnostics (non audible)1
OPTIONS Blank= No Options -DA= Improved Diagnostics (audible)1 -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) -CW4= Cold Weather 40°F to 104°F (-40°C to 40°C)3
Lamp Type MUST: 1) Match Battery Voltage 2) Total of all lamps wattage must not exceed battery watt capacity for 90 min. -DA includes a time delay feature that can be enabled/ disabled in the field or set by the factory by including -D-TD* 2 -NEX & -NEXRF is CSA-US approved only. Consult your sales representative 3 -CW4 option only available with V12G1 & V12G2 models 1
1
1
o other lamp types available for this N Series, for complete information on these lamp types refer to page 153.
- D includes a time delay feature that can be enabled/disabled in the field or set by the factory by including -D-TD*
EXAMPLE: 2V12G2/M12-B-D-CW4
www.lightalarms.com
91
SEVERE
TM
VH SERIES
Class I, Division 2 Housing 6V-18W & 12V up to 72W Capacities Lead-Calcium battery FEATURES
SPECIFICATIONS
Housing • Class I Division 2, Groups A, B, C and D • Lamps shielded by a clear vandal-resistant polycarbonate cover • Two fully tool-less adjustable glare-free MR16 lighting heads • Front and Back plates are of a heavy duty 1/8 inch thick aluminum • Stainless steel tamper-proof screws
Supply and install Lightalarms® Severe™ VH Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free Lead-Calcium battery of 6V or 12V with watts as specified. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60 Hz and be CSA-US approved. The unit shall be certified for use in Hazardous locations: Class I Division 2, Groups A, B, C and D. The unit charger shall utilize a micro-controller which samples the battery in relation to the ambient temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, and short-circuit protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dust-tight relay, Green LED pilot light to indicate AC-On and a magnetic test switch allows for quick operational check of entire system. The Improved Diagnostics shall continuously monitor every critical function of the unit. If a malfunction occurs, the green pilot indicator LED located on the unit will change to red and begin to a flash, indicating a fault. If an audible optional alarm is specified, a high-pitch audible alarm will sound as well as the illuminating the fault pilot indicator. A detailed diagnostic legend next to the pilot indicator LED provides fault identification as battery, charger circuitry or lamps failure. The microcontroller shall automatic self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code for one minute every 30 days, 30 minutes every six months and 90 minutes annually. The frame shall be of industrial grade polyvinyl chloride with gaskets around both sides of the frame contour. The frame shall be covered by two plates made of 1/8 inch thick aluminum sheets. The back plate shall include four keyholes for wall mount application. The front plate shall include water lenses for AC On and Service required pilot light indicators. Two fully tool-less adjustable glarefree MR16 lighting heads covered by a shock-absorbent clear vandal-resistant polycarbonate cover. Every Severe™ VH Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting: • Surface Wall Mount Only • Includes mounting lugs on each side of the housing • Backplate included universal knock-outs to mount to any standard 4” junction box • 1/2 inch Conduit knock-outs entry on both sides and top of housing Choice of Lamp Type • MR16 Halogen Lamp, 12V-12W or 12V-20W • MR16 LED Lamp, 6V-4W, 12V-4W or 12V-5W Electronics • Micro-controller based charging circuit • Automatic, temperature compensated, pulse type charger • High capacity, automatic, solid-state transfer “spark-free” • Low voltage disconnect prevents over discharge of battery • Battery lock-out prevents battery discharge during installation • Fused output circuit Improved Diagnostics • Units equipped with Improved Diagnostics shall self-test, by simulating a power failure, in accordance with NFPA101, Life Safety Code minimum 30 seconds every 30 days, 30 minutes every six months and 90 minutes annually. For complete information refer to page 8. Nexus® Option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101, Life Safety Code minimum 30 seconds every 30 days, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature a real-time diagnostics, as well as, be able to locate exact fixture location while notifying service personnel to the status of the fixture via email notification. For complete information refer to page 4-5. Controls • Red AC-On LED indicates Ac power is on • Magnetically operated test switch allows for quick operational check of entire system Sealed-Maintenance Free Battery • 6 or 12V Lead-Calcium battery
Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding LED lamps and fuses)1 • Lead Calcium Battery has a 3 year full, plus 3 year pro-rata warranty For LED lamps warranty, refer to page 168 paragraph 3.2
92
WG3-L
Wire Guard
Approvals • CSA-US approved • Evaluated to UL924 Standard • Evaluated to the UL 844 Standard for Class I Division 2, Groups A, B, C and D • NEC, OSHA and NEMA compliant for above Classes and Groups • Ambiant temperature 50-104F (10-40C) • Certified temperature codes for several emergency lamp types • Certified for use in damp and wet locations
1
ACCESSORIES (Order as a separate item) SEVERE™ CLASS 1, DIVISION 2 FAMILY The Severe™ VH Battery Unit is part of the Severe™ family of Class I Division 2 rated emergency lighting products. Extremely resistant to strong impacts, vibrations and variations in temperature, this family of products is ideally suited for areas with the risk of the presence of flammable gases, or vapors or liquids able to create an explosive gas atmosphere.
Severe™ XVHZ & XVEHZ Exit Series p.44
www.lightalarms.com
Severe™ XVH Combo Series p.46
Severe™ ELF651 Remote Series p.113
US
TYPE
Designed to meet the specific requirements of Class I, Division 2, Groups A, B, C, and D, hazardous areas
CATALOG #
NOTES
DIMENSIONS
Dimensions are approximate and subject to change. 14-1/2” [36.8 cm]
3-1/2” [8.7 cm]
6-1/4” [15.9 cm]
12-5/8” [32.1 cm]
13-3/4” [34.9 cm]
TEMPERATURE CODES: MR16LED LAMPS LAMPS SUFFIX
VOLTAGE
WATTAGE
TEMPERATURE CODE
MAX. TEMPERATURE
REPLACEMENT #
LD1
6
4
T4A
120°C
580.0097-L
LD7
12
4
T4A
120°C
580.0093-L
LD9
12
5
T4A
120°C
580.0104-L
MR16 HALOGEN LAMPS LAMPS SUFFIX
VOLTAGE
WATTAGE
TEMPERATURE CODE
MAX. TEMPERATURE
REPLACEMENT #
M12
12
12
T3C
180°C
580.0080-L
MH20
12
20
T2C
230°C
580.0168-L
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS
AC SPECS
6V
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 18 12 9 0
VH12G1
12V
36
27
18
14
VH12G2
12V
60
45
30
24
VH12G3
12V
72
54
36
28
BATTERY TYPE
DC VOLTAGE
Lead-Calcium
VHG1
2
ORDERING FORMAT # OF HEADS 0= No head 2= 2 Heads
SERIES VHG1= 6V-18W VH12G1= 12V-36W VH12G2= 12V-60W VH12G3= 12V-72W
LAMP TYPE1
MR16 LED Lamp LD1= 6V-4W MR16 LED LD7= 12V-4W MR16 LED LD9= 12V-5W MR16 LED o other lamp types available for this Series, for N complete information on these lamp types refer to page 153.
120/277VAC
.17A/.09A
120VAC 277VAC
.3A .15A
OPTIONS Blank= IDNA -DA= Improved Diagnostics (optional - audible)1 -D= Improved Diagnostics (included standard - non audible) -NEX= Nexus® Wired Compatible2 -NEXRF= Nexus® Wireless Compatible2 -T1= Time Delay (5 minute) -T2= Time Delay (10 minute) -T3= Time Delay (15 minute) 1
1
CURRENT MAXIMUM
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
COLOR G= Grey
MR16 Halogen Lamp M10= 12V-10W M12= 12V-12W MH20= 12V-20W
UNITS DUAL VOLTAGE2
2
- ID & -IDNA include a time delay feature that can be enabled/disabled in the field or set by the factory by including -ID-TD* or -IDNA-TD* -NEX & -NEXRF is CSA-US approved only. Consult your sales representative
EXAMPLE: 2VHG1LD1G
www.lightalarms.com
93
Spin-off gasketed cover
Copper-free cast aluminum
EXP6N & EXP12N SERIES
3/4” NPT conduit entrance
Stainless Steel Vent/Drain
Combination Test Switch & Pilot Light
Explosives/Hazardous location Housing 6V up to 50W & 12V up to 72W Capacities Nickel-Cadmium battery
FEATURES
SPECIFICATIONS
Housing • Class I, Division 1 & 2, Group C & D • Class II, Division 1 & 2, Group E, F & G • One-piece heavy gauge, corrosion resistant, copper-free cast aluminum • Consists of a housing with provisions for up to two lighting heads • Spin-off gasketed cover prevents propagation of internally generated arcs • Stainless steel vent/drain • Lighting head fixtures are heavy cast aluminum with Pyrex® lens • Circuit board silicone conformal coated to protect against humidity
Supply and install Lightalarms® EXP6N, EXP12N Series. The emergency lighting unit shall be a self-contained fixture including a sealed maintenance-free NickelCadmium battery of 6V or 12V wattage as specified on the unit rating chart. The unit shall supply the rated wattage load for a minimum of 90 minutes to 87-1/2% of rated battery voltage. The unit shall be rated 120/277VAC, 60Hz . The unit charger shall utilize an integrated circuit which samples the battery in relation to temperature, state of charge and input voltage fluctuations. The charger shall be current limited. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 87-1⁄2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL 924 specifications. The unit shall be furnished with solid state transfer, a combination momentary test switch, to simulate a power failure and an AC indicator light which indicates presence of AC to the unit. The cabinet shall be Hazardous Location, one-piece heavy gauge, corrosion resistant, copper-free cast aluminum, finished in gray. Housing with provisions of up to two lighting head and includes 4 mounting lugs on each corner and a 3/4” NPT conduit entry on the top and bottom. Spin-off gasketed cover prevents propagation of internally generated arcs into the hazardous atmosphere. Lighting head are heavy cast aluminum with Pyrex® lens(es). Housing shall be surface wall mount with or without attached lamp heads. EPF401 lighting heads not attached to housing, thus being remote heads, shall be surface, wall, ceiling or pendent mount. Single and double pendant mount fixtures include elbow swivel, conduit extension pipe (6” increments) and combination explosion-proof junction box / mounting plate. Every EXP6N, EXP12N Series unit shall be fully warranted for three years, subject to proper installation and maintenance. Unit shall be Lightalarms® catalog number__________________.
Mounting • Surface Wall Mount for complete unit with attached lamp heads • Surface, Wall, Ceiling and Pendant Mount for EPF401 as DC remote heads • Housing includes 4 mounting lugs on each corner • 3/4” NPT conduit entry on top and bottom of housing • Single and double pendant mount heads include elbow swivel, conduit extension pipe (6” increments) and Hazardous Location junction box. Electronics • High capacity, automatic, solid-state transfer • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection is provided • Battery lock-out prevents battery discharge during installation • Fused output circuit • Input: 120/277 VAC, 60Hz 0.3/0.15A Controls • Combination momentary test switch and AC present indicator light Sealed Maintenance-Free Battery • 6V or 12V, Nickel-Cadmium battery Approvals • Manufactured in accordance with UL844, UL1203, and UL924 • Cabinet and lighting fixtures rated for operation in Class I, Division 1 & 2, Groups C and D • Cabinet and lighting fixtures rated for operation in Class II, Division 1 & 2, Groups E, F and G • NEC, OSHA and NEMA compliant for above Classes and Groups Warranty (subject to proper installation and maintenance) • Unit has a three year full warranty (excluding lamps and fuses)1 • Nickel-Cadmium battery, five year full, plus five year pro-rata warranty 1
For LED lamps warranty, refer to page 168 paragraph 3.2
LAMP SELECTION CHART WEDGE BASE INCANDESCENT LAMPS LAMP SUFFIX
VOLTAGE
Housing: 12” X 12” X 9-1/2”. Mounting Lugs: 10” and 13-1/2” on center Overall dimensions (including fixtures): 38” X 38” X 10”
94
LUMENS
REPLACEMENT #
L9
6V
9W
126
570.0010-L
L18
6V
18W
300
570.0037-L
L9
12V
9W
126
570.0011-L
L18
12V
18W
276
570.0030-L
L25
12V
25W
400
570.0031-L
DIMENSIONS
Dimensions are approximate and subject to change.
WATTAGE
BI-PIN HALOGEN LAMPS LAMP SUFFIX
VOLTAGE
WATTAGE
LUMENS
REPLACEMENT #
LH4
6V
6W
113
570.0012-L
LH5
6V
8W
163
570.0013-L
LH7
6V
10W
200
570.0017-L
LH6
6V
12W
240
570.0011-L
LH1
6V
15W
210
570.0086-L
LH8
12V
8W
163
570.0014-L
LH3
12V
12W
276
570.0010-L
Note: Units are supplied standard with appropriate wattage (HIT) high intensity tungsten lamps (unless otherwise specified). Alternate wattage lamps or halogen lamps may be substituted as required.
www.lightalarms.com
Spin-off gasketed cover
TYPE
Designed to meet the specific requirements Class I, Division 1&2, Groups C and D Class II, Division 1&2, Groups E, F and G Complies with NEC, OSHA and NEMA specification
CATALOG #
NOTES
3/4” NPT conduit entrance
Copper-free cast aluminum
Stainless Steel Vent/Drain
Combination Test Switch & Pilot Light
POWER CONSUMPTION / UNIT RATING CHART SERIES
DC SPECS BATTERY TYPE
DC VOLTAGE
Nickel-Cadmium
EXP6N18
6V
AC SPECS
87.5% BATTERY CAPACITY (IN WATTS)1 90 MIN. 2 HRS. 3 HRS. 4 HRS. 18 12 0 0
EXP6N25
6V
25
28
9
9
EXP6N36
6V
36
21
12
12
EXP6N50
6V
50
36
18
18
EXP12N36
12V
36
21
12
12
EXP12N50
12V
50
36
18
10
EXP12N72
12V
72
42
24
24
2
STANDARD CONFIGURATIONS FOR EXP6N AND EXP12N SERIES UNIT
UNITS DUAL VOLTAGE2
CURRENT MAXIMUM
120VAC 277VAC
.3A .15A
1 National Electrical Code Specification All units 120/277 dual voltage, information based on wiring to specific voltage type
CATALOG NUMBER
DESCRIPTION
EXP12N50
12V self-contained hazardous area emergency lighting power unit complete with battery and charger.
EXP12N50-TS
12V self-contained hazardous area emergency lighting. power unit complete with battery charger and transfer switch.
EXP6N50E402/LH1
Single head unit with 6V-15W Bi-Pin halogen lamp.
EXP6N50E402/LH1-TS
Single head unit with 6V-15W lamp shown with Transfer Switch option.
EXP6N50E402/L9-2
6V self-contained hazardous area emergency lighting power units complete with battery and charger and two heads. Each fixture supplied with one 9W HIT lamp.
EXP6N50E402/L9-TS-2
6V self-contained hazardous area emergency lighting. Power unit complete with battery, charger, 2 heads and transfer switch. Each fixture supplied with one 9W HIT lamp.
(Remote capability)
Note: Above units are supplied with appropriate wattage (HIT) High Intensity Tungsten lamps (unless otherwise specified). Alternate wattages lamps or halogen lamps may be substituted as required.
ORDERING FORMAT SERIES EXP6N18= 6V-18W EXP6N25= 6V-25W EXP6N36= 6V-36W EXP6N50= 6V-50W EXP12N36= 12V-36W EXP12N50= 12V-50W EXP12N72= 12V-72W
HEAD STYLE Blank= No Heads E402= Head Style
LAMP SUFFIX1
1
TS OPTION
# OF HEADS
Blank= No Transfer Switch -TS= Transfer Switch
/______
n page 94 choose from O lamp selection chart no other lamp types available
Blank= One head -2= Two heads
OPTIONS Blank= No options -AG= Angle reflector -DM= Dome reflector -GD= Wire guard (covers glass globe only)
EXAMPLE: EXP6N36/LH5-2
EXP FAMILY Ideal for industrial applications, the EXP family include explosion-proof fixtures to deliver reliable performance and with stand harsh conditions.
EPF401 Remote Head p.114
X402 Series Exit Sign Unit p.48
EXP6N & EXP12N Combination Series p.49
www.lightalarms.com
95
Remote Fixtures, Remote Heads & Unit Heads
About Remote Fixtures and Lamp Information
ARCHITECTURAL Recessed Mount Remote Fixture PhantomTM Series
ARCHITECTURAL Recessed Mount Remote Fixture DecorativeTM Series
ARCHITECTURAL Surface Mount NEMA-3R Remote Fixture Camray® LED Series
ARCHITECTURAL Surface Mount NEMA-3R Remote Fixture Saf-T-RayTM Series
98-99
100
101
102
103
ARCHITECTURAL Surface Mount Remote Head & Unit Head DR Series
COMMERCIAL Surface Mount Remote Head & Unit Head ELF2 Series
COMMERCIAL Surface Mount Remote Head & Unit Head ELF3 Series
COMMERCIAL Surface Mount Remote Head & Unit Head ELF623 Series
COMMERCIAL Surface Mount Remote Head & Unit Head ELF645 Series
104
105
106
107
108
INDUSTRIAL Surface Mount Remote Head & Unit Head ELF647 Series
COMMERCIAL & INDUSTRIAL Surface Mount Remote Fixture Vandal-Resistant ELF640 Series
COMMERCIAL & INDUSTRIAL Surface Mount Remote Fixture NEMA-4X ELF650 Series
INDUSTRIAL Surface Mount Explosion / Hazardous Remote Fixture ELF647C Series
INDUSTRIAL Surface Mount Explosion / Hazardous Remote Fixture ELF651 Series
109
110
111
112
113
INDUSTRIAL Surface Mount
INDUSTRIAL Surface Mount
Explosion / Hazardous Remote Fixture EPF401 Series
Explosion / Hazardous Remote Fixture X402 Exit Series
114
115
INTRODUCTION
www.lightalarms.com
97
TYPE CATALOG #
About Remote Fixtures & Head Illumination NOTES
Emergency Lighting Heads and the lamps they use: Illuminating a Path of Egress Emergency Lighting Heads and the choice of lamps used within those heads is the most important element of an emergency lighting system’s performance getting people to safety in an emergency situation. The light output or lumens provided by the lamp is a key factor in evacuating a building quickly and safely during an emergency situation, thus possibly saving lives. Providing the correct amount of light allows people to easily see their path of egress, saving precious seconds exiting a building in an emergency situation when every second counts. The Life Safety Code, which can be found at the back of this catalog, provides information on the minimum light levels that should illuminate a path of egress for safe evacuation, and the required foot candles at floor level. The lumen output of a lamp can provide different foot candle levels based on the mounting height of the lighting head or fixture. A photometric layout with the lighting heads mounted at the height of installation and the lamps being used will provide a visual estimation of the foot candle levels achieved at floor level. Emergency lighting heads should be installed to provide illumination along the path of egress of no less then an average of 1 footcandle, with no point at less then 0.1 footcandle. The heads should also be mounted in such a way that if one lamp should fail, it will not leave an area with less than 0.2 foot candle of illumination. Local and state codes may have other requirements. It is always good practice to check with the appropriate inspector about the illumination required.
Important considerations when choosing the proper lamp Emergency Lighting is required to provide illumination for a minimum of 90 minutes or an hour and a half during an emergency situation. Emergency Lighting lamps powered from a DC battery source must be powered by a battery that has the capacity to power all the lamps using that battery source for a minimum of 90 minutes. It is important to choose the correct lumen output lamp to meet the required illumination at the floor level on a path of egress. It is equally important to match the lamp and the battery voltages. If you do not have a battery that is the same voltage as the lamp and with enough wattage capacity to illuminate all the lamps, then the lamps will not provide adequate lumen output for 90 minutes to meet the required illumination at floor level along the path of egress.
Available lamp types are shown on the Lamp Selection Chart on the catalog page for each head style or fixture type. Lamp Selection Chart information refers to a single lamp. If you are using a double or triple lamp type head or fixture, the wattage draw of that head or fixture will be the total number of lamps used. For example, if you are using a double lamp fixture with a 12W lamp, that fixture will have a 24W draw (two lamps of 12W each, 12W + 12W = 24W total).
Lamp Life It is often asked why emergency lighting lamps have such a short lamp life. Who wants a lamp that only lasts 50 hours? However, considering that most of the time emergency lighting lamps are not illuminated, 50 hours is not such a short life. If power failures are relatively scarce; for example, 90 minutes 4 times a year, then emergency lighting would only be required for six hours. If you add in monthly testing and a 90-minute annual test, that lamp would be illuminated for an average of 8 hours a year. Based on that example, a lamp with a 50-hour life is more than adequate for emergency lighting. By design, some emergency lighting lamps are made to burn brighter using the same wattage draw as lamps that could have a longer life but not burn as bright. A brighter burn lamp has a shorter life, but in an emergency situation, the brighter the better. Lamp improvements are continuously being made to make them brighter, draw less wattage, increase lumen efficacy per watt, and provide longer life. LED lamps have taken emergency lighting lamps to a whole new level. For example, our 12V-6W MR16 LED lamp provides 540 lumens with a lamp life of over 30,000 hours.
First, match voltage. The voltage of the lamp MUST exactly match the voltage of the battery powering that lamp. If the voltage of the battery is lower than the voltage of the lamp, the lamp may not illuminate. If the voltage of the battery is higher than the voltage of the lamp, the lamp may “pop”. Second, consider total wattage. The wattage of each individual lamp drawing from a battery during emergency operation, including the lamps mounted on the unit as well as all remote lamps wired to that unit, added together, CAN NOT EXCEED the total wattage capacity of that battery within 90 minutes of operation. A unit’s battery wattage capacities are shown in the Unit Rating Chart of each particular unit.
98
www.lightalarms.com
TYPE CATALOG #
NOTES
Lamp Types: Wedge Base Incandescent and Bi-Pin Halogen These two lamps types are commonly referred to as miniature lamps with a tungsten filament burning differently based on the gas filled within that lamp. Lamps with a tungsten filament enclosed within the glass case of the lamp, filled with a gas mixture of argon and nitrogen are generally referred to as incandescent lamps. A bi-pin halogen lamp, which is filled with iodide/chloride gas, allows the tungsten filament to burn at a higher temperature. This higher temperature burn results in a higher lumen output, thus being 20-30% superior to a standard incandescent lamp of the same voltage and wattage. A typical bi-pin halogen lamp used in emergency lighting has a 50-hour lamp life. PAR36 Sealed Beam Incandescent and Halogen Lamp lumen output is also dependent on the lamp optics – the reflector and lens that make up the lamp. Protecting the lamp optics is especially critical in damp areas where vapors and water condensation can deteriorate the reflector’s performance. Sealed beam lamps are recommended for such applications. Sealed beam lamps have a metal-coated glass reflector and a lens sealed together with argon and nitrogen gas for incandescent lamps, or iodide/chloride gas for halogen lamps. Different gases affect the filament burn temperatures and lumen output. Halogen lamps burn hotter, thus providing brighter illumination. PAR36 sealed beam lamps have a lamp life of 50-300 hours, with an efficacy of 12-25 lumens per watt.
40-ft. Path of egress 2 X 4W MR16 LED
MR16 Halogen MR16 stands for Multi-facetted Reflector, 16/8-inch diameter lamp. The MR16 lamp contains everything in one small package: a halogen lamp, a metal-coated glass reflector, and a clear glass cover cemented to the reflector. An MR16 lamp is easy to install and replace if needed – just push it in or pull it out of the lamp socket. Additional benefits of MR16 lamps include a high lumen output, a long lamp life of 2,000 to 6,000 hours, and an efficacy of 11-30 lumens per watt. MR16 LED The MR16 LED lamp contains everything in one small package: long-life, high lumen output, and a high lumens-to-watts efficacy ratio. An MR16 lamp is easy to install and replace if needed – just push it in or pull it out of the lamp socket. Our 12V-6W MR16LED lamp has a lumen output of 540 for an average spacing of 100 feet center-to-center. With an efficacy of 91.9 lumens per watt, that’s 3 times the efficacy of an MR16 20W high-output lamp. An MR16 LED lamp has a life of over 30,000 hours.
100-ft. Path of egress 2 X 6W MR16 LED
www.lightalarms.com
99
US
REMOTE FIXTURE PHANTOM™ SERIES
FEATURES
CATALOG #
NOTES
Virtually Invisible, Architecturally Pleasing
Shown with MR16 LED lamps
TYPE
LAMP SELECTION CHART
Description • Indoor use • Two lamp MR16 remote fixture with a choice of halogen or LED • One-piece all-metal module design (does not require large galvanized steel back box as does the battery back-up unit) • Complete 360° door rotation, 180° to open 180° to close • Slip gear mechanism protects the unit from objects that would cause the door rotation to be forcibly stopped. Finish • Flat door and frame are covered with a high-quality, powder coated textured off-white finish • Surface finish can be customized on site with paint, wallpaper or other coverings. Mounting • The DC-remote fixture unit includes as an option (specify when ordering a hardware kit for installation in T-Bar ceiling structure). • The module includes the electrical junction box and is installed on the wall stud or ceiling beam with the help of a simple, U-shape bracket. • Key-hole slot for ease of installation Approval • CSA-US
LAMP SUFFIX
MR 16 HALOGEN LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
M12
12
12
80
580.0080-L
M20
12
20
150
580.0064-L
MH20
12
20-H
400
580.0068-L
M35
12
35
430
580.0083-L
MH35
12
35-H
830
580.0090-L
M50
12
50
700
580.0076-L
MH50
12
50-H
1460
580.0089-L
M12
24
12
82
580.0070-L
M20
24
20
240
580.0077-L
M35
24
35
235
580.0084-L
M50
24
50
670
580.0076-L
LAMP SUFFIX
MR 16 LED LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0101-L
LD10
12
6
540
580.0106-L
LD13
24
4
200
580.0098-L
DIMENSIONS
Dimensions are approximate and subject to change. 9-1/8” [23.1cm]
DC voltage junction box
7-1/4” [18.3cm]
7-1/4” [18.3cm]
3-3/4” [9.6cm]
ORDERING FORMAT SERIES
LAMP SUFFIX
12PMR2= 12 VDC1 24PMR2= 24 VDC1
/ __________1
1
1
Double lamp remote fixture
Choose from lamp selection chart
EXAMPLE: 12PM2R-M50 100
OPTIONS DL= Damp location
www.lightalarms.com
TYPE
REMOTE FIXTURE DECORATIVE™ SERIES
CATALOG #
NOTES
Contemporary and Enduring Style
FEATURES
LAMP SELECTION CHART
Description • Indoor Use • Powder-coated die cast aluminum construction • Tool-less lamp head adjust ability • Glass MR16 lamp lens • Choice of MR16 Halogen or LED Lamp
LAMP SUFFIX
Finish • Choice of White, Black, Chrome, Brushed Nickel or Polished Brass Mounting • Recessed Ceiling Mount • Must order appropriate housing with Decorative head selection for installation into new construction ceiling (LU-GRHR03) or Non-Insulated ceiling (LU-GRHR05) GU10 or Insulated ceiling (LU-GRHR06)
DIMENSIONS
Dimensions are approximate and subject to change. 7.25 in. 7-1/4” 180 mm [18.41cm]
5-3/5” 5.6 in. 142 mm [14.22cm] 44” in. 102 mm [10.16cm] 7.8 in. 7-4/5” [19.81cm] 199 mm 14-24 in. 14-24” [35.56cm] 356-609 mm
44” in. 102 mm [10.16cm] in. 11-1/4”11.25 [28.57cm] 280 mm 14-24 in. 14-24” [35.56cm] 356-609 mm
LU-GRHR03
LU-GRHR06
4-1/4” [10.16cm]
3-1/2” [7.62cm] 4” [10.16cm] 14-7/16” [35.56cm]
LU-GRHR05
SERIES RSTH24
RSTH18
RSTH18R
Description: Decorative lighting head Dimensions: 4.0” diameter base Color Suffix: -WH= White, -BK= Black, -CH= Chrome, -PB= Polished brass, -BN= Brushed Nickel Description: Decorative lighting head Dimensions: 4.0” diameter base Color Suffix: -WH= White or -BN= Brushed nickel Description: Decorative lighting head Dimensions: 4.0” diameter base Color Suffix: -WH = White or -BN = Brushed nickel
RSTH19
Description: Decorative lighting head Dimensions: 4.0” diameter base Color Suffix: -WH = White
LU-GRHR03
Housing Enclosure Description: New construction housing Dimensions: 5.6” x 14.24”
LU-GRHR05
Housing Enclosure Description: New construction housing New construction housing for GU10
LU-GRHR06
Housing Enclosure Description: Insulated ceilings housing Dimensions: 7.25” x 14.24”
MR 16 HALOGEN LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
M5
6
5
34
580.0072-L
M6
6
6
40
580.0074-L
M10
6
10
74
580.0079-L
M10
12
10
84
580.0099-L
M12
12
12
80
580.0080-L
M20
12
20
150
580.0064-L
MH20
12
20-H
400
580.0068-L
M35
12
35
430
580.0083-L
MH35
12
35-H
830
580.0090-L
MH31
12
37-H
900
580.0088-L
M50
12
50
700
580.0076-L
MH50
12
50-H
1460
580.0089-L
M12
24
12
82
580.0070-L
M20
24
20
240
580.0077-L
MA20
24
20-A
220
580.0094-L
M35
24
35
235
580.0084-L
M50
24
50
670
580.0076-L
M20
120
20
100
580.0065-L
M35
120
35
230
580.0066-L
LAMP SUFFIX
MR16 LED LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
LD1
6
4
130
580.0097-L
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0098-L
LD10
12
6
540
580.0106-L
LD13
24
4
200
580.0104-L
LD26
120
4
200
580.0113-L
LD14
24
6
590
580.0100-L
MR16 LED LAMPS COMPATIBILITY CHART HEAD STYLE 6V-4W 12V-4W 24V-4W 12V-5W 12V-6W 120V-4W RSTH18
X
X
X
–
–
RSTH18R
X
X
X
X
X
– X
RSTH19
X
X
X
X
X
X
RSTH24
–
–
–
–
–
–
ORDERING FORMAT
(Must also order Housing Enclosure based on Ceiling Type, sold separately)
SERIES LAMP SUFFIX RSTH24 RSTH18 RSTH18R RSTH19
/ __________1 1
Choose from lamp selection chart
COLOR -WH= White -BK= Black (available with RSTH24 only) -CH= Chrome (available with RSTH24 only) -BN= Brushed Nickel (available with RSTH19) -PB= Polished Brass (available with RSTH24 only)
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC 120= 120 VAC/VDC
EXAMPLE: RSTH18/M6-WH With Housing Enclosure Example: LU-GRHR06 (for Insulated Ceiling installation)
www.lightalarms.com
101
NEMA-3R TYPE
REMOTE FIXTURE CAMRAY® LED SERIES
CATALOG #
NOTES
Low-profile, slim look and performance in a Remote Fixture FEATURES
NEW DESIGN & LED FOR NORMALLY-ON AND/OR EMERGENCY BACK-UP
!
NEW
PHOTOMETRIC
Description • Indoor or Outdoor Use • (4) 100% LED light engine with redundant connections and very wide beam • Powder-coated Die-Cast aluminum construction • Clear Polycarbonate lens allows for maximum lumen output • Optional forward-throw light distribution, for applications of outdoor Exit discharge (OSHA 1910.36) • Optional dual-mode: normal and emergency LED lighting with separate AC inputs • Optional high-lumen output: 25-50% additional level of illumination • Optional photo-switch: dusk-to-dawn control of normal lighting • Optional remote test: infrared remote control (keyboard ordered separately) • 400-640 Lumens • Color temperature: 5000K
TABLE A: SPACING FOR NFPA101 (AVERAGE = 1FC, SEE NOTE) MODEL TYPE
MOUNTING LUMEN COLOR WIDTH X LENGTH (FT) HEIGHT TEMPERATURE SINGLE UNIT CENTER-TO-CENTER
Standard
9’
400
6’ X 50’
6’ X 50’
With option -H
11’
550
6’ X 60’
6’ X 60’
With option -FT
12’
460
6’ X 40’
—
With option -FTH
15’
640
6’ X 50’
—
5000K
3’ X 70’
Indoor reflectance: 80/50/20 and 10-ft wide corridor. Outdoor reflectance: 0/30/10
Note: The illumination level meets ALL the requirements of the Life Safety Code (NFPA 101): 1) Average of 1 foot-candle or more 2) Minimum at any point of 0.1 foot-candle or more 3) Maximum-to-minimum illumination uniformity ratio of 40:1 or less
Finish • Choice of four finishes, off-white, Black, platinum gray or dark bronze Mounting • Surface Wall Mount • Universal knock-out for mounting to a standard 4” octagonal electrical box 50’
Approval • UL Listed • NEMA-3R • UL Listed for Damp and Wet Location • Operating temperature -40°F to 122°F (-40°C to + 50°C)
TABLE B: SPACING FOR MINIMUM ILLUMINATION = 1FC MODEL TYPE
Dimensions are approximate and subject to change. 3” [7.5 cm]
9-1/2” [24 cm]
6-5/8” [16.8cm]
9’ 6’
DIMENSIONS 3” [7.5 cm]
28’
MOUNTING LUMEN HEIGHT
COLOR TEMPERATURE
WIDTH X LENGTH (FT) SINGLE UNIT CENTER-TO-CENTER
Standard
9’
400
4’ x 28’
4’ x 32’
With option -H
11’
550
4’ x 32’
4’ x 40’
With option -FT
12’
460
4’ x 22’
—
With option -FTH
15’
640
4’ x 27’
—
5000K
Window for photo-switch (optional)
12’
22’
Front View
Side View
40’ 6’
ORDERING FORMAT SERIES CAM= Camray LED ®
MODEL1
COLOR
AC= AC-only ACDC= AC/6-12VDC remote DC= 6-12VDC remote fixture 2AC= AC-only two circuits: 120/120 or 277/277V
1
B= Black DB= Dark bronze OW= Off white PG= Platinum gray
Temperature range: -40°C + 50°C (-40°F - 122°F)
EXAMPLE: CAMACDCB-H
102
www.lightalarms.com
OPTIONS -FT= Forward throw lighting -H= High lumen output (-40°C - 30°C) (-40°F - 86°F) -P= Photo-switch (AC and ACDC only) -RC= Remote control - infrared (AC and ACDC only)1 1 With -RC option, order the remote control keypad (TB-RC1-L) separately
NEMA-3R TYPE
REMOTE FIXTURE SAF-T-RAY™ SERIES
CATALOG #
NOTES
Wall Mount Remote Head for Damp and Wet Locations
FEATURES
LAMP SELECTION CHART
Description • Indoor or Outdoor use • Double MR16 size lighting head • Die-Cast aluminum construction • Fully gasketed cover available with (optional) Tamper Proof Screws • Adjustable tool-less aiming swivel head rotates side to side and tilts in and out • Impact- and tamper-resistant polycarbonate diffuser maximizes light output
LAMP SUFFIX
Finish • Mist white, black or dark gray Mounting • Surface Wall Mount • Universal knock-outs for mounting to a standard 4” octagonal electrical box Approval • UL Listed • NEMA-3R
DIMENSIONS
Dimensions are approximate and subject to change.
7” [17.78cm] 77”7
MR 16 HALOGEN LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
M5
6
5
34
580.0072-L
M6
6
6
40
580.0074-L
M10
6
10
74
580.0079-L
M10
12
10
84
580.0099-L
M12
12
12
80
580.0080-L
M20
12
20
150
580.0064-L
MH20
12
20-H
400
580.0068-L
M12
24
12
82
580.0070-L
M20
24
20
240
580.0077-L
M20
120
20
100
580.0065-L
LAMP SUFFIX
MR 16 LED LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
LD1
6
4
130
580.0097-L
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0098-L
LD10
12
6
540
580.0106-L
LD13
24
4
200
580.0104-L
LD25
120
4
200
580.0010-L
5” [12.70cm] 5 55”
8”
88” 8[20.32cm]
ORDERING FORMAT SERIES
LAMP SUFFIX
SAF-2= Double lamp 90ºremote fixture 90º 90º
90º
/ __________1
1
40º40º
COLOR -M= Mist White -B= Black -DG= Dark Gray -DB= Dark Bronze
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC 120= 120 VAC/VDC
OPTIONS -VR= Vandal resistant screws -C= Clear lens
Choose from lamp selection chart
EXAMPLE: SAF-2/M6-M6
www.lightalarms.com
103
Available Mounted on: • TBR Series • RD Series • S12E Series • MG & MN Series • PG & P12G Series • PN & P12N Series • PQ & P12Q Series
TYPE
REMOTE HEAD & UNIT HEAD DR SERIES
CATALOG #
NOTES
Metal MR16 Lamp Head
FEATURES
LAMP SELECTION CHART
Description • Indoor use • Available as a single, double or triple MR16 size lighting head • Die cast aluminum construction • Fully tool-free adjustable aiming swivel head • Clear glass lens
MR 16 HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
Finish • Powder-coated white or black Mounting • Surface Mount • Includes canopy plate for mounting to a standard 4” octagonal electrical box. Approval • UL Listed
DIMENSIONS
Dimensions are approximate and subject to change. 5” [12.7cm]
5” [12.7cm]
4-3/8” [11.11cm]
4-5/8” [11.74cm]
80°
320°
DR1130 5” [12.7cm]
4-1/8” [10.47cm]
6
5
34
580.0072-L
M6
6
6
40
580.0074-L
M10
6
10
74
580.0079-L
M10
12
10
84
580.0099-L
M12
12
12
80
580.0080-L
M20
12
20
150
580.0064-L
MA20
12
20-A
225
580.0075-L
MH20
12
20-H
400
580.0068-L
M35
12
35
430
580.0083-L
MH35
12
35-H
830
580.0090-L
MH31
12
37-H
900
580.0088-L
M50
12
50
700
580.0076-L
MH50
12
50-H
1460
580.0089-L
M12
24
12
82
580.0070-L
M20
24
20
240
580.0077-L
MA20
24
20-A
220
580.0094-L
M35
24
35
235
580.0084-L
M50
24
50
670
580.0076-L
M20
120
20
100
580.0065-L
M35
120
35
230
580.0066-L
M50
120
50
460
580.0067-L
MR 16 LED LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
320°
5” [12.7cm]
9-5/8” [24.44cm]
4” [10.16cm]
REPLACEMENT #
M5
REPLACEMENT #
LD1
6
4
130
580.0097-L
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0104-L
LD10
12
6
540
580.0106-L
LD13
24
4
200
580.0098-L
LD14
24
6
590
580.0100-L
LD25
120
4
200
580.0010-L
DR3130
DR2130
ACCESSORIES
(Order as a separate item) WG8-L WG2-L
Wire Guard for DR1130, DR2130 Wire Guard for DR3130
ORDERING FORMAT SERIES DR1130= Single remote head DR2130= Double remote head DR3130= Triple remote head
LAMP SUFFIX
COLOR -WH= White -BK= Black
/ __________1
1
Choose from lamp selection chart
EXAMPLE: DR1130/M12-WH12 104
www.lightalarms.com
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC 120= 120 VAC/VDC
Available Mounted on: • TBR Series • RD Series • S12E Series • MG & MN Series • PG & P12G Series • PN & P12N Series • PQ & P12Q Series
TYPE
REMOTE HEAD & UNIT HEAD ELF2 SERIES
CATALOG #
NOTES
Thermoplastic Par 18 size lamp head
FEATURES
LAMP SELECTION CHART
Description • Indoor Use • Available as a single, double or triple Par 18 size lighting head • Thermoplastic construction • Fully adjustable tool-less aiming swivel head • Specular parabolic reflector and prismatic lens for wide-beam, even light distribution • Snap out lens for easy lamp replacement.
WEDGE BASE INCANDESCENT LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
L12
12
12
150
570.0028-L
Finish • Mist white or black
L18
12
18
264
570.0029-L
Mounting • Surface Mount • Includes a 5” round universal canopy plate with 3 knockouts (supplied with 2 plugs) for use with single, double or triple head mounting. • Mounts to either a standard 4” octagonal or a single gang electrical box. (4-gang plate for ELF2D optional). Approval • UL Listed
DIMENSIONS
Dimensions are approximate and subject to change.
L5
6
5.4
68
570.0012-L
L7
6
7.2
100
570.0026-L
L9
6
9
150
570.0016-L
L9
12
9
138
570.0025-L
L9
24
9
113
570.0045-L
L18
24
18
239
570.0046-L
BI-PIN HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS LH4
6
6
113
REPLACEMENT # 580.0012-L
LH5
6
8
163
580.0013-L
LH7
6
10
201
580.0017-L
LH6
6
12
239
580.0011-L
LH8
12
8
163
580.0014-L
LH3
12
12
276
580.0015-L
LH9
12
14
302
580.0016-L
3-3/16 (8.2cm)
2-15/16” [7.4cm]
5-9/16” [14.2cm]
ELF2
5” [12.7cm] 8-5/16” [21.1cm]
3-3/16” [8.1cm]
4-13/16” [12.3cm]
ELF2D
5” [12.7cm] 3-3/16” [8.1cm]
8-1/2” [21.6cm]
5-5/8” [14.3cm]
ELF2T
5” [12.7cm]
ORDERING FORMAT SERIES ELF2= Par18 head
# OF HEADS Blank= Single head D= Double heads T= Triple heads
LAMP SUFFIX / __________1
COLOR M= Mist White B= Black
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC
1
Choose from lamp selection chart
EXAMPLE: ELF2/LH5-M6
www.lightalarms.com
105
Available Mounted on: • TBR Series • RD Series • S12E Series • MG & MN Series • PG & P12G Series • PN & P12N Series • PQ & P12Q Series
REMOTE HEAD & UNIT HEAD ELF3 SERIES
TYPE CATALOG #
NOTES
Thermoplastic MR16 Lamp Head
FEATURES
LAMP SELECTION CHART
Description • Indoor use • Available as a single, double or triple Par 18 size MR16 lighting head • Thermoplastic construction • Fully adjustable tool-less aiming swivel head • Specular parabolic reflector and prismatic lens for wide-beam, even light distribution • Snap-out lens for easy lamp replacement.
MR 16 HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
REPLACEMENT #
M5
580.0072-L
Finish • Mist white or black Mounting • Surface Mount • Includes a 5” round universal canopy plate with 3 knockouts (supplied with 2 plugs) for use with single, double or triple head mounting. • Mounts to either a standard 4” octagonal or a single gang electrical box. (4-gang plate for ELF3D optional). Approval • UL Listed
DIMENSIONS
6
5
34
M6
6
6
40
580.0074-L
M10
6
10
74
580.0079-L
M10
12
10
84
580.0099-L
M12
12
12
80
580.0080-L
M20
12
20
150
580.0075-L
M12
24
12
82
580.0070-L
LAMP SUFFIX VOLTAGE LD1
6
MR 16 LED LAMPS WATTAGE LUMENS 4
130
REPLACEMENT # 580.0097-L
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0104-L
LD10
12
6
540
580.0106-L
LD13
24
4
200
580.0098-L
LD14
24
6
590
580.0100-L
Dimensions are approximate and subject to change. 2-5/8” [6.7cm] 5-1/8” [12.9cm]
3-1/4” [8.1cm]
ELF3
5” [12.7cm] 3-1/4” [8.2cm] 4-1/2” [11.3cm]
7-7/8” (19.9cm)
ELF3D
5” [12.7cm] 7-7/8” [19.9cm] 5-1/8” [13cm]
4-1/8” [10.4cm]
ELF3T
5” [12.7cm]
ACCESSORIES
(Order as a separate item) WG8-L
Wire Guard
ORDERING FORMAT SERIES ELF3= MR16 Par18 head
# OF HEADS Blank= Single head D= Double heads T= Triple heads
LAMP SUFFIX / __________1
COLOR -B= Black -M= Mist White
1
Choose from lamp selection chart
EXAMPLE: ELF3/M10-M6 106
www.lightalarms.com
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC
Available Mounted on: • TBR Series • RD Series • S12E Series • MG & MN Series • PG & P12G Series • PN & P12N Series • PQ & P12Q Series
TYPE
REMOTE HEAD & UNIT HEAD ELF623 SERIES
CATALOG #
NOTES
Thermoplastic Square Lamp Head
FEATURES
LAMP SELECTION CHART
Description • Indoor use • Available as a single, or double square lighting head • Thermoplastic construction • Fully adjustable tool-less aiming swivel • Specular parabolic reflector and prismatic lens for wide-beam, even light distribution • Snap-out lens for easy lamp replacement.
WEDGE BASE INCANDESCENT LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
L12
12
12
150
570.0028-L
Finish • Mist white or black
L18
12
18
264
570.0029-L
Mounting • Surface Mount • Includes a 5” round universal canopy plate with 3 knockouts (supplied with 2 plugs) for use with single or double head mounting. • Mounts to either a standard 4” octagonal or a single gang electrical box. (4-gang plate for ELF623D optional). Approval • UL Listed
DIMENSIONS
Dimensions are approximate and subject to change.
L5
6
5.4
68
570.0012-L
L7
6
7.2
100
570.0026-L
L9
6
9
150
570.0016-L
L9
12
9
138
570.0025-L
L9
24
9
113
570.0045-L
L18
24
18
239
570.0046-L
BI-PIN HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
REPLACEMENT #
LH4
6
6
113
580.0012-L
LH5
6
8
163
580.0013-L
LH7
6
10
201
580.0017-L
LH6
6
12
239
580.0011-L
LH8
12
8
163
580.0014-L
LH3
12
12
276
580.0015-L
LH9
12
14
302
580.0016-L
4-3/8” [11.11cm]
5-5/8” [14.28cm]
ELF623 5” (12.7cm)
8-1/8” [20.63cm]
5-1/2” [13.97cm]
ELF623D 5” [12.7cm]
ACCESSORIES
(Order as a separate item) WG8-L
Wire Guard
ORDERING FORMAT SERIES ELF623= Square Head
# OF HEADS Blank= Single head D= Double heads
LAMP SUFFIX / __________1
COLOR -M= Mist White -B= Black
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC
1
Choose from lamp selection chart
EXAMPLE: ELF623/L9-M12
www.lightalarms.com
107
Available Mounted on: • TBR Series • RD Series • S12E Series • MG & MN Series • PG & P12G Series • PN & P12N Series • PQ & P12Q Series
TYPE
REMOTE HEAD & UNIT HEAD ELF645 SERIES
CATALOG #
NOTES
Thermoplastic PAR36 Lamp Head
FEATURES
LAMP SELECTION CHART
Description • Indoor use • Available as a single, double or triple Par 36 size lighting head • Thermoplastic construction • Fully adjustable tool-less aiming swivel head • Specular parabolic reflector and prismatic lens for wide-beam, even light distribution • Snap-out lens for easy lamp replacement • Sealed Beam lamps not compatible with Nickel-Cadmium battery Finish • Mist white, black or gray Mounting • Surface Mount • Includes a 5” round universal canopy plate with 3 knockouts (supplied with 2 plugs) for use with single, double or triple head mounting • Mounts to either a standard 4” octagonal or a single gang electrical box (4-gang plate for ELF645D optional) Approval • UL Listed
DIMENSIONS
Dimensions are approximate and subject to change. ELF645
4-3/4” [12.06cm]
3-5/8” [9.20cm]
L5 L7 L9 L9 L12 L18 L9 L18
6 6 6 12 12 12 24 24
5.4 7.2 9 9 12 18 9 18
68 100 150 138 150 264 113 239
570.0012-L 570.0026-L 570.0016-L 570.0025-L 570.0028-L 570.0029-L 570.0045-L 570.0046-L
BI-PIN HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
REPLACEMENT #
LH4 LH5 LH7
580.0012-L 580.0013-L 580.0017-L
6 6 6
6 8 10
113 163 201
LH6
6
12
239
580.0011-L
LH8
6
20
402
580.0022-L
LH8
12
8
163
580.0014-L
LH3
12
12
276
580.0015-L
LH9
12
14
302
580.0016-L
LH2
12
20
314
580.0027-L
PAR36 SEALED BEAM INCANDESCENT LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
7-1/4” [18.41cm]
5” [12.7cm]
ELF645D
3-1/2” [8.89cm]
10-7/8” [27.62cm]
6-3/8” [16.19cm]
5” [12.7cm]
ELF645T
WEDGE BASE INCANDESCENT LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
13-3/8” [31.43cm]
6
8
130
550.0018-L
6
12
170
550.0030-L
4014
6
18
250
550.0016-L
4510
6
25
350
550.0017-L
4515
6
30
420
550.0035-L
4044
12
12
190
550.0026-L
4414
12
18
210
550.0027-L
4446
12
25
395
550.0023-L
25WFL
12
25
360
550.0028-L
25VWFL
12
25
160
550.0050-L
50NSP
12
50
300
550.0043-L
50WFL
12
50
300
550.0029-L
PAR36 SEALED BEAM HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT # 6-3/8” [16.19cm]
9-1/2” [24.13cm]
ACCESSORIES (Order as a separate item) WG9-L
Wire Guard
7613 4042
H7556 H7551 H7552 H7553 H7554 H7555 H7557 H7616 H7614
6 6 6 6 6 12 12 12 12
6 8 10 12 20 8 12 37 50
107 155 190 225 380 160 230 700 950
550.0022-L 550.0036-L 550.0037-L 550.0019-L 550.0021-L 550.0024-L 550.0025-L 550.0047-L 550.0012-L
ORDERING FORMAT SERIES EF645= Par36 head
# OF HEADS Blank= Single head D= Double head T= Triple head
LAMP SUFFIX / __________* *
Choose from lamp selection chart
COLOR -M= Mist white (not available with 30W or higher lamp) -B= Black (not available with 30W or higher lamp) -G= Gray
EXAMPLE: ELF645/LH6-M6 108
www.lightalarms.com
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC
Available Mounted on: • FG & FG12 Series
TYPE
REMOTE HEAD & UNIT HEAD ELF647 SERIES
CATALOG #
NOTES
Thermoplastic Weather-Resistant PAR36 Lamp Head FEATURES
LAMP SELECTION CHART
Description • Outdoor use • Available as a single, double or triple Par 36 size lighting head • Thermoplastic construction with aluminum canopy plate • Fully adjustable aiming swivel head • Specular parabolic reflector and prismatic lens to assure a wide-beam, even light distribution • Sealed for rain; dust-tight; corrosion resistant • Sealed Beam lamps not compatible with Nickel-Cadmium battery Finish • Mist white, black or gray Mounting • Surface Mount • Includes a universal aluminum canopy • Mounts to a standard 4” octagonal electrical box
LAMP SUFFIX
WEDGE BASE INCANDESCENT LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
L5 L7 L9 L9 L12 L18 L9 L18
6 6 6 12 12 12 24 24
5.4 7.2 9 9 12 18 9 18
LAMP SUFFIX
BI-PIN HALOGEN LAMPS VOLTAGE WATTAGE LUMENS REPLACEMENT #
LH4 LH5 LH7
6 6 6
6 8 10
68 100 150 138 150 264 113 239
113 163 201
570.0012-L 570.0026-L 570.0016-L 570.0025-L 570.0028-L 570.0029-L 570.0045-L 570.0046-L
580.0012-L 580.0013-L 580.0017-L
LH6
6
12
239
580.0011-L
LH8
6
20
402
580.0022-L
Approval • UL Listed • Weather Resistant
LH8
12
8
163
580.0014-L
LH3
12
12
276
580.0015-L
DIMENSIONS
LH9
12
14
302
580.0016-L
LH2
12
20
314
580.0027-L
Dimensions are approximate and subject to change. 4-3/4” [12.06cm]
PAR36 SEALED BEAM INCANDESCENT LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
3-3/4” [9.52cm]
7-1/4” [18.41cm]
ELF647 4-1/4” [10.79cm]
12-1/2” [31.75cm]
12-1/2” [31.75cm]
3-3/4” [9.52cm] 7-1/4” [18.41cm]
5-1/2” [13.97cm]
ELF647D
ELF647T
4-1/4” [10.79cm]
4-1/4” [10.79cm]
ACCESSORIES
WG9-L
Wire Guard
ORDERING FORMAT SERIES
6
8
130
550.0018-L
6
12
170
550.0030-L
4014
6
18
250
550.0016-L
4510
6
25
350
550.0017-L
4515
6
30
420
550.0035-L
4044
12
12
190
550.0026-L
4414
12
18
210
550.0027-L
4446
12
25
395
550.0023-L
25WFL
12
25
360
550.0028-L
25VWFL
12
25
160
550.0050-L
50NSP
12
50
300
550.0043-L
50WFL
12
50
300
550.0029-L
PAR36 SEALED BEAM HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
(Order as a separate item)
ELF647= Weather Resistant head
7613 4042
# OF HEADS Blank= Single head D= Double heads T= Triple heads
H7556
6
6
107
550.0022-L
H7551
6
8
155
550.0036-L
H7552
6
10
190
550.0037-L
H7553
6
12
225
550.0019-L
H7554
6
20
380
550.0021-L
H7555
12
8
160
550.0024-L
H7557
12
12
230
550.0025-L
H7616
12
37
700
550.0047-L
H7614
12
50
950
550.0012-L
LAMP SUFFIX / __________1 1
Choose from lamp selection chart
COLOR -M= Mist white (not available with 30W or higher lamp) -B= Black (not available with 30W or higher lamp) -G= Gray
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC
EXAMPLE: ELF647/H7551-B6
www.lightalarms.com
109
!
NEW
VANDAL RESISTANT ELF640
TYPE
ELF640 SERIES
CATALOG #
ELF640 Vandal Resistant NOTES
FEATURES
LAMP SELECTION CHART
Description • ELF640 Vandal Resistant Indoor use only • ELF640 choice of cast aluminum or plastic back plate • ELF640 Vandal Resistant comes standard with Phillips head screws, optional tamper proof screws • Available as single or double MR16 lamp size remote lighting fixture • Include clear polycarbonate UV and impact resistant cover • Tool-less, fully adjustable, aiming swivel head and easy lamp replacement
MR 16 HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
REPLACEMENT #
M6
580.0074-L
Finish • White, Black or Gray Mounting • Surface Mount • Includes a back plate for mounting to a standard 4” octagonal electrical box Approval • UL Listed • Vandal Resistant
6
6
40
M10
6
10
74
580.0079-L
M10
12
10
74
580.0099-L
M12
12
12
80
580.0080-L
M12
24
12
80
580.0070-L
M201
12
20
270
580.0064-L
M201
24
20
240
580.0077-L
MH201
12
20-H
400
580.0068-L
Not available with ELF640P Series (12W lamp max).
1
LAMP SUFFIX VOLTAGE LD1
DIMENSIONS
Dimensions are approximate and subject to change.
MR 16 LED LAMPS WATTAGE LUMENS
6
4
130
REPLACEMENT # 580.0097-L
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0104-L
LD10
12
6
510
580.0106-L
LD13
24
4
200
580.0098-L
7-1/8” [18.09cm]
3-3/4” [9.52cm]
4-5/8” [11.74cm]
ORDERING FORMAT - ELF640 SERIES SERIES ELF640P= All polycarbonate single head for dry location1 ELF640PD= All polycarbonate double head for dry location1 ELF640= Die-Cast back plate single head for dry location ELF640D= Die-Cast back plate double head for dry location
LAMP SUFFIX
COLOR -M= White -B= Black -G= Gray
/ __________1
1 1
Up to 12W lamps max and 4W MR16 LED max
Choose from lamp selection chart
EXAMPLE: ELF640P/M12-M12 110
www.lightalarms.com
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24V DC
OPTIONS Blank= no option T= tamper proof screws
TYPE
ELF650 SERIES
CATALOG #
ELF650 NEMA-4X & NSF Certified NOTES
FEATURES
LAMP SELECTION CHART
Description • ELF650 NEMA-4X and NSF Certified Indoor or Outdoor use • ELF650 NEMA-4X and NSF Certified with choice of fully gasketed cast aluminum or plastic back plate1 • ELF650 NEMA-4X and NSF Certified comes standard with Phillips head screws and tamper proof screws • Available as single or double MR16 lamp size remote lighting fixture • Include clear polycarbonate UV and impact resistant cover • Tool-less, fully adjustable, aiming swivel head and easy lamp replacement
MR 16 HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS
REPLACEMENT #
M6
580.0074-L
Finish • White, Black or Gray
1
Mounting • Surface Mount • Includes a back plate for mounting to a standard 4” octagonal electrical box
6
40
M10
6
10
74
580.0079-L
M10
12
10
74
580.0099-L
M12
12
12
80
580.0080-L
M12
24
12
80
580.0070-L
M201
12
20
270
580.0064-L
M201
24
20
240
580.0077-L
MH201
12
20-H
400
580.0068-L
Not available with ELF650P Series (12W lamp max).
LAMP SUFFIX VOLTAGE
Approval • UL Listed • Vandal Resistant • NEMA-4X1 • NSF Rated 1
6
LD1
6
MR 16 LED LAMPS WATTAGE LUMENS 4
130
REPLACEMENT # 580.0097-L
LD7
12
4
170
580.0093-L
LD9
12
5
340
580.0104-L
LD10
12
6
510
580.0106-L
LD13
24
4
200
580.0098-L
ELF650P & ELF650PD units are NEMA-4X Certified when installed using a circular NEMA-4X rated junction box (sold seperatly by Thomas&Betts under P/N 091647-L)
DIMENSIONS
Dimensions are approximate and subject to change.
7-1/8” [18.09cm]
4-5/8” [11.74cm]
3-3/4” [9.52cm]
ORDERING FORMAT - ELF650 SERIES SERIES ELF650= Die-Cast back plate NEMA-4X and NSF Certified with single head ELF650D= D ie-Cast back plate NEMA-4X and NSF Certified with double head ELF650P= A ll polycarbonate NEMA-4X and NSF Certified with single head1 ELF650PD= All polycarbonate NEMA 4X and NSF Certified with double head1
LAMP SUFFIX / __________1
COLOR -M= Mist White -B= Black -G= Gray
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC
1 1
Up to 12W lamps max and 4W MR16 LED max
Choose from lamp selection chart
EXAMPLE: ELF650/M12-M12
www.lightalarms.com
111
TYPE
REMOTE FIXTURE ELF647C SERIES
CATALOG #
Class I Division 2, Groups A, B, C and D Certified Remote Fixture
NOTES
FEATURES
LAMP SELECTION CHART
Description • Indoor use • Available as a single or double Par 36 size • Thermoplastic construction, with gasketed aluminum canopy plate and junction box • Fully adjustable tool-less aiming swivel head • Specular parabolic reflector and prismatic lens for wide-beam, even light distribution
PAR36 SEALED BEAM HALOGEN LAMPS LAMP SUFFIX VOLTAGE WATTAGE LUMENS REPLACEMENT #
Finish • Gray only
H7553
6
12
255
550.0019-L
H7557
12
12
230
550.0025-L
DIMENSIONS
Dimensions are approximate and subject to change. ELF647DC
Mounting • Surface Mount • Includes a universal aluminum canopy and junction box • Conduit entry ½” NPT Approval • UL Listed • Class I, Division 2, Groups A, B, C and D
12” [30.48cm]
ACCESSORIES
(Order as a separate item) WG6-L
Wire Guard
4-3/16” [10.63cm]
ELF647C 5” [12.7cm]
4-3/4” [12.06cm]
8-7/8” [22.54cm] 1-3/4” [4.44cm] 4-3/16” [10.63cm]
ORDERING FORMAT SERIES ELF647C= Single lamp remote fixture ELF647DC= Double lamp remote fixture
LAMP SUFFIX / __________1
1
Choose from lamp selection chart
EXAMPLE: ELF647C/H7553
112
www.lightalarms.com
COLOR -Blank= Gray -M= Mist White -B= Black w
US
TYPE
REMOTE FIXTURE ELF651 SERIES
CATALOG #
NOTES
Class I Division 2, Groups A, B, C and D Certified Remote Fixture
FEATURES
LAMP SELECTION CHART
Description • Available with single or double lamp heads with high-efficiency MR16 halogen lamps of 10W, 12W or 20W or high-output LEDs of 4W, 5W or 6W • Die-Cast aluminum back plate with gasket. Clear polycarbonate cover, UV and impact resistant • Input voltage: 6V, 12V, 24V or 120V • Easy installation on a 4” octagonal box (included). Comes standard with tamper-proof screws and bit • Extreme operational temperature range: -40ºF to +104ºF (-40ºC to +40ºC) • Indoor use • Fully adjustable tool-less aiming swivel • Tool-less easy lamp replacement Finish • Gray
MR16 HALOGEN LAMPS LAMP REPLACEMENT TEMP VOLT WATT LUMENS MAX TEMP SUFFIX NUMBER CODE M10
6
10
74
580.0079-L
T3B
329°F/165°C
M12
12
12
80
580.0080-L
T3B
329°F/165°C
MH20
12
20-H
400
580.0068-L
T2C
446°F/230°C
M12
24
12
82
580.0070-L
T3B
329°F/165°C
M20
24
20
240
580.0077-L
T3B
221°F/105°C
M20
120
20
100
580.0065-L
T2C
257°F/125°C
MR16 LED LAMPS LAMP REPLACEMENT TEMP VOLT WATT LUMENS MAX TEMP SUFFIX NUMBER CODE LD1
6
4
200
580.0097-L
T4A
248°F/120°C
Mounting • Surface Mount • Conduit entry 1/2” NPT
LD7
12
4
220
580.0093-L
T5
212°F/100°C
LD9
12
5
340
580.0104-L
T4A
248°F/120°C
LD10
12
6
540
580.0106-L
T4
275°F/135°C
Approval • Evaluated to UL 844 Standard for Class I Division 2, Groups A, B, C and D. Temperature Codes: T3B (10W and 12W MR16 lamps) and T2C (20W MR16 lamps) and T4A and T5 MR16 LED
LD13
24
4
220
580.0098-L
T5
212°F/100°C
LD26
120
4
230
580.0113-L
T4A
248°F/120°C
DIMENSIONS
Dimensions are approximate and subject to change. 5-7/8” (14.92cm)
7-1/8” [18.09cm]
Remote Fixture
Junction Box
3-3/4” [9.52cm]
2-1/8” [5.39cm]
4-5/8” [11.74cm]
ORDERING FORMAT SERIES ELF651= Single lamp remote fixture ELF651D= Double lamp remote fixture
LAMP SUFFIX
1
COLOR -G= Gray
/ __________1
VOLTAGE 6= 6 VDC 12= 12 VDC 24= 24 VDC 120= 120 VAC/VDC
Choose from lamp selection chart
EXAMPLE: ELF651/M10-G6
www.lightalarms.com
113
TYPE
REMOTE FIXTURE EPF401 SERIES
CATALOG #
NOTES
Hazardous Location Remote Fixtures
FEATURES
LAMP SELECTION CHART
Description • Indoor use • Available as a single or double • Heavy cast aluminum • Pyrex Lenses
HIGH INTENSITY TUNGSTEN LAMP SUFFIX VOLTAGE WATTAGE LUMENS
L9
12
9
126
570.0011-L
Finish • Painted Grey
L18
12
18
276
570.0030-L
L25
12
25
400
570.0031-L
Mounting • Surface Mount: Wall or Ceiling • Pendant Mount: Single Head or Double Head • Pendant mount including hazardous location elbows, swivels and conduit extension pipe (6” increments) • Combination hazardous location junction box/mounting plate • Conduit entry ½” NPT Approval • UL Listed for use in Paint Spray Areas (75W max) • Class I, Division 1&2, Groups C and D • Class II, Division 1&2, Groups E, F and G • Class III, Division 1&2, (150W max) • Complies with NEC, OSHA and NEMA for above classes and groups
6
9
126
570.0010-L
L18
6
18
300
570.0037-L
LAMP SUFFIX VOLTAGE
BI-PIN HALOGEN WATTAGE LUMENS
REPLACEMENT #
LH4
6
6
113
580.0012-L
LH5
6
8
163
580.0013-L
LH7
6
10
200
580.0017-L
LH6
6
12
240
580.0011-L
LH1
6
15
210
580.0086-L
LH8
12
8
163
580.0030-L
LH3
12
12
276
580.0015-L
DIMENSIONS Dimensions are approximate and subject to change.
OPTIONS
(Add Suffix to Model No.)
Suffix
Angle Reflector: Highly reflective white finish inside and out. Attaches to globe holder ring with four screws
-AG
Dome Reflector: Highly reflective white finish inside and out. Attaches to globe holder ring with four screws
REPLACEMENT #
L9
Ceiling Mount
Wall Mount
14-1/2” [36.83cm]
13-5/8” [34.60cm]
7-1/2” [19.05cm]
-DM
Pendant Mount
14-1/2” [36.83cm]
Double Pendant Mount 25-1/2” [64.77cm]
Guard: One-piece aluminum casting construction. Attaches to globe holder ring with four screws
6” [15.24cm]
-GD
6” [15.24cm]
22-1/8” [56.19cm]
30-7/8” [78.42cm] 13-5/8” [34.60cm] 13-3/4” [34.92cm] 7-1/2” [19.05cm]
7-1/2” [19.05cm]
ORDERING FORMAT SERIES EPF401= Single Lamp Remote Fixture
MOUNTING W= Wall Mount C= Ceiling Mount P= Pendant Mount D= Double Pendant Mount
LAMP SUFFIX / __________1
1
Choose from lamp selection chart
EXAMPLE: EPF401W/L96 114
www.lightalarms.com
VOLTAGE 6= 6 VDC 12= 12 VDC
OPTIONS Blank= No Option -AG= Angle Reflector -DM= Dome Reflector -GD= Guard
X402C= Ceiling Mount
TYPE
X402 EXIT SIGN SERIES
CATALOG #
NOTES
X402W= Wall Bracket Mount X402P= Pendant Mount
Class I, Division 1 & 2, Groups C and D Class II, Division 1 & 2, Groups E, F and G
FEATURES
DIMENSIONS
Description • Indoor use • Available as single or double face with red or green Legend • Heavy cast aluminum • Pyrex Lenses
Dimensions are approximate and subject to change. Ceiling Mount 5-3/4” [14.6 cm]
Finish • Painted Grey
9-1/8” [23.17 cm]
Mounting • Surface Mount: Wall or Ceiling • Pendant Mount • Pendant mount including hazardous location elbows, swivels and conduit extension pipe (6” increments) • Combination hazardous location junction box/mounting plate • Conduit entry ½” NPT
16-7/8” [42.86 cm]
Wall Mount
Approval • UL Listed for use in Paint Spray Areas (75W max) • Class I, Division 1&2, Groups C and D • Class II, Division 1&2, Groups E, F and G • Class III, Division 1&2, (150W max) • Complies with NEC, OSHA and NEMA for above classes and groups
17-3/4” [45.08 cm]
Pendant Mount 6” [15.24 cm] 6” [15.24 cm]
34-1/8” [86.67 cm] 16-7/8”
LAMP SELECTION CHART, X402 EXIT SIGN (ONLY) (lamp automatically specified in model number based on voltage of unit) LAMP TYPE Quartz Bi-Pin
VOLTAGE 6V
LAMP WATTAGE 15W
12V Medium Base
24V
25W
120V
LAMP TYPE
AVERAGE LIFE (HOURS)
LAMP SUFFIX
REPLACEMENT LAMP PART #
JC-6V15W
2000
6
580.0086-L
25A-12
1000
12
570.0071-L
143A
1000
24
570.0118-L
A19
2500
120
570.0136-L
ORDERING FORMAT AC-Only or AC/DC Exit Sign Faces 1= Single Face 2= Double Face
Series X402
Mounting C= Ceiling W= Wall P= Pendant
Transfer Panel (Required for the operation of the X402 AC/DC Exit Sign) AC voltage DC voltage Series 120= 120V AC -6= 6V DC -TS 277= 277V AC -12= 12V DC -24= 24V DC
Lamp -6= 6V -12= 12V -24= 24V -120= 120V
Legend color R= Red G= Green
Watts -25= 25W -50= 50W -75= 75W -100= 100W
EXAMPLE: AC-Only or AC/DC Exit Sign: 1X402C12R, Transfer Panel (needed for AC/DC operation): 12012TS25
www.lightalarms.com
115
Emergency Ballasts
INTRODUCTION
INTRODUCTION Ballast/Lamp Reference Chart
EMERGENCY BALLAST LADL7 Series 750 Lumens Damp location Listed
EMERGENCY BALLAST LADL12 Series 1350 Lumens Damp location listed
EMERGENCY BALLAST LADL20-N Series 750 Lumens Damp location listed
118
119
120
121
122
EMERGENCY BALLAST LADL28 Series 500 Lumens
EMERGENCY BALLAST LADL30-N Series 3000 Lumens Damp location listed
EMERGENCY BALLAST LADL32 Series 500 Lumens Damp location listed
EMERGENCY BALLAST LADL540 Series 1300 Lumens
TRANSFER SWITCH EPC-1-L Series
123
124
125
126
127
www.lightalarms.com
117
About Emergency Fluorescent Ballast packs and AC Inverters About Emergency Fluorescent Ballast Packs and AC Inverters Emergency Fluorescent Ballast Packs and AC Inverters are completely selfcontained battery-powered systems designed to invert DC battery current to AC current in order to operate AC lighting loads in the event of an emergency. Under normal conditions: AC current flows into the Ballast or Inverter, keeping the DC batteries charged, and AC current continues to power the AC lighting fixture. In an Emergency situation: When AC current stops flowing into the Ballast or Inverter, the Inverter converts DC battery current into AC current to power the AC lighting fixture.
Lumens and Wattage Capacities Emergency Fluorescent Ballasts come in various lumen output capacities and are designed to operate only 1 or 2 lamps in a fluorescent fixture type. AC Inverters are based on total wattage capacities and are designed to operate multiple lighting fixtures with different lamp types in an emergency situation.
Emergency Fluorescent Ballast: Designed to operate fluorescent lighting loads, these ballasts can be mounted directly on or in the existing fluorescent fixture and are meant to operate one or two lamps within that fixture. Emergency Fluorescent Ballasts are selected based on the lumen output levels needed in an emergency situation and the lamp type being used in the fluorescent fixture during normal AC operation.
Mini Interruptible Inverter Systems: These systems are designed to keep incandescent, fluorescent, and LED lighting operating properly when there is a break in power. Available in 32-720W models.
Single Phase Transfer IPS Systems: These systems are designed to keep incandescent, fluorescent, and LED lighting operating properly when there is a break in power. The transfer time is 50 milliseconds. Available in single phase from 1500VA to 16700VA.
Single Phase Fast Transfer Systems (UPS): These systems are designed to operate in much the same way as the IPS system, but with a transfer time that is sufficient to keep HID lighting on and operate incandescent, fluorescent, and LED lighting loads with no break in power to the critical load upon failure or restoration of the AC power source. Available in single phase from 500VA to 16700VA.
Three Phase Fast Transfer Systems (UPS): These fast transfer systems operate on 3 phase 4 wire (120/208VAC or 277/480VAC) utility power. Available for 3 phase applications from 4800VA to 50000VA. The transfer time is sufficient to keep HID lighting on and operate incandescent, fluorescent, and LED lighting loads.
118
www.lightalarms.com
Ballast/Lamp Reference Chart MODEL #
LADL7
LADL12
LADL20-N
LADL28
LADL30-N
LADL32
LADL540
Lumens
750
1350
750
500
3000
500
1300
X
X X X
X
X
X X X
X
X
Lamp Type (# of Lamps) 2'-4' Rapid, Instant, Energy Saving, T8 thru T12 (1) 2'-4' Rapid, Instant, Energy Saving, T8 thru T12, HO & VHO (2) 2'-8' Rapid, Instant, Energy Saving, T8 thru T12, HO & VHO (1) F15 T8 (1) F17 T8 (1) F17 T8 (2) F25 T8 (1) F25 T8 (2) F28 T8 (1) F32 T8 (1) F32 T8 (2) F40 T8 (1) FO96 T8 59W (1) 14W T5 (1) 14W T5 (2) 21W T5 (1) 21W T5 (2) 24W T5 (1) 28W T5 (1) 28W T5 (2) 39W T5 (1) 54W T5 HO (1) 54W T5 HO (2) F20 T12 (1) F20 T12 (2) F40 T12 (1) F40 T12 (2) F48 T12 (1) F96 T12 60W (1)
LINEAR LAMPS
X X
X X
X
X X X X X X X X X X
X X X X X X X X X X
X X X X
Lamp Type (# of Lamps) 18W Long Compact (1) 18W Long Compact (2) 24W Long Compact (1) 24W Long Compact (2) 36W Long Compact (1) 36W Long Compact (2) 40W Long Compact (1) 40W Long Compact (2) 50W Long Compact (1) 50W Long Compact (2) 55W Long Compact (1) 7W PL CF 2-Pin (1) 9W PL CF 2-Pin (1) 13W PL CF 2-Pin (1) 18W PL CF 2-Pin (1) 26W PL CF 2-Pin (1) 13W PL CF 4-Pin (1) 13W PL CF 4-Pin (2) 18W PL CF 4-Pin (1) 18W PL CF 4-Pin (2) 26W PL CF 4-Pin (1) 26W PL CF 4-Pin (2) 32W PL CF 4-Pin (1) 32W PL CF 4-Pin (2) 42W PL CF 4-Pin (1) 42W PL CF 4-Pin (2) 57W PL CF 4-Pin (1) 57W PL CF 4-Pin (2) 70W PL CF 4-Pin (1) 20W Circline (1) 22W Circline T9 (1) 22W Circline T5 (1) 40W Circline T8 (1) 40W Circline T5 (1) 55W Circline T5 (1) F28 2D (1) F28 2D (2) F38 2D (1) F38 2D (2)
X X
X X X X X X X X X X X X X X
X X X X X X
X X X X X
X
X
X
X
X
X X X X X X X
COMPACT LAMPS – BIAX LAMPS
X X X X X
X X
X X X X X X
X X
X X X X X X
X X X X X X X X X
www.lightalarms.com
X X X X X X X X X X X
X X X
X X X X X X X X X X
X X
X X X X X
119
TYPE
LADL7 SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting units 750 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Optional end caps available • Operating temperature 68°F to 122°F (20°C to 50°C) Mounting • Internal or external mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • One 14-54W or two 14-39W • (2’-4’) T5 and T8 lamps with instant start or rapid start or one 4-pin • 18-50W long compact fluorescent or one 4-pi • 32W compact fluorescent or one 24-32W U-Bend lamp • T5 Lamps • Long Compact Lamps • 4-Pin Compact Fluorescent Lamps Lumen Output • (1) Lamp 440-750 Lumens • (2) Lamps 400-690 Lumens Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 60Hz, 3.7W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL7 Series. The LADL7 fluorescent emergency ballast shall be a single steel housing selfcontained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL7 fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 750 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL7 Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ .
ACCESSORIES (order as separate item) External mounting kit includes wire bundle cover
EC6
Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate)
PSW PSW1
Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
Charging Indicator Light
Replacement Test Switch
TBTSP-L
ORDERING FORMAT SERIES LADL7
EXAMPLE: LADL7 120
Push Button Test Switch
DIMENSIONS
Dimensions are approximate and subject to change.
Length: B[35.88cm] Length 14-1/4”
Center: A LengthMounting 13-3/4” [34.92cm]
HeightHeight: 1-1/8” C [2.86cm] Width: D Width 2-1/8” [5.4cm]
COMPATIBLE LAMP CHART LAMP F14W T5 F21W T5 F24W T5/HO F28W T5 F39W T5/HO F54W T5/HO F14W T8 F20W T8 F28W T8 F32W T8 F36W T8 F39W T8 F54W T8 F32W PLCF Quad 4pin Long compact F36W Long compact F40W Long compact F50W PLC F30BX, 40BX, 50BX F24W U-BEND FBT8 F32W U-BEND FBT8
www.lightalarms.com
VOLTAGE
WATTAGE
120/277V
14 21 24 28 39 54 14 20 28 32 36 39 54 32 36 40 50 30, 40, 50 24 32
INITIAL LUMENS 1-LAMP 2-LAMP 480 680 440 750 670 600 450 550 625 700 680 620 500 550 610 625 510 650 580 630
440 640 410 690 640 650 400 520 580 670 650 580 – 510 570 – – – 550 600
TYPE
LADL12 SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting units 1350 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Optional end caps available • Operating temperature 68°F to 122°F (20°C to 50°C) Mounting • Internal or external mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • One 14-54W or two 14-39W • (2’-4’) T5 and T8 lamps with instant start or rapid start or one 4-pin • 18-50W long compact fluorescent or one 4-pin • 32W compact fluorescent or one 24-32W U-Bend lamp Lumen Output • (1) Lamp 800-1350 Lumens • (2) Lamps 850-1300 Lumens Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 60Hz, 3.7W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL12 Series. The LADL12 fluorescent emergency ballast shall be a single steel housing selfcontained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL12 fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 1350 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL12 Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ .
ACCESSORIES (order as separate item) External mounting kit includes wire bundle cover Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate) Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
PSW PSW1 Charging Indicator Light Push Button Test Switch
TBTSP-L
Replacement Test Switch
ORDERING FORMAT SERIES LADL12
EXAMPLE: LADL12
EC6
DIMENSIONS
Dimensions are approximate and subject to change.
Length: B[35.88cm] Length 14-1/4”
Center: A LengthMounting 13-3/4” [34.92cm]
Height 1-1/8” Height: C [2.86cm] Width: D [5.4cm] Width 2-1/8”
COMPATIBLE LAMP CHART LAMP F14W T5 F21W T5 F24W T5/HO F28W T5 F39W T5/HO F54W T5/HO F14W T8 F20W T8 F28W T8 F32W T8 F36W T8 F39W T8 F54W T8 F32W PLCF Quad 4pin PLC F36W PLC F40W PLC F50W PLC F30BX, 40BX, 50BX F24W U-BEND FBT8 F32W U-BEND FBT8
www.lightalarms.com
VOLTAGE
WATTAGE
120/277V
14 21 24 28 39 54 14 20 28 32 36 39 54 32 36 40 50 30, 40, 50 24 32
INITIAL LUMENS 1-LAMP 2-LAMP 880 1000 1250 1300 1200 1150 900 1150 1200 1350 1200 1150 1100 1100 1050 1100 1000 1300 1050 1150
850 960 1210 1250 1130 – 850 1120 1180 1300 1150 1100 – 1050 1000 – – – 1000 1100
121
TYPE
LADL20-N SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting units 750 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Operating temperature 32°F to 122°F (0°C to 50°C) Mounting • Internal or external mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC • Operates one 17W-40W T8 through T12, two 13W-39W, one 13W-42W 4-pin compact or one 18W-40W 4-pin long compact fluorescent lamps Lumen Output • (1) Lamp 350-750 Lumens • (2) Lamps 425-750 Lumens Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 60Hz, 1.8W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL20-N Series. The LADL20-N fluorescent emergency ballast shall be a single steel housing self-contained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL20-N fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 750 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL20-N Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ .
ACCESSORIES (order as separate item) Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate)
PSW PSW1
Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
Charging Indicator Light
Replacement Test Switch
ORDERING FORMAT SERIES
DIMENSIONS
Dimensions are approximate and subject to change.
Length Length: 9-3/8” [23.81cm] B
Mounting Center: A Length 8-7/8” [22.54cm]
Height 1-1/2” Height: C [3.81cm]
D Width Width: 2-3/8” [6.03cm]
COMPATIBLE LAMP CHART LAMP 4-pin PL CF
120/277V
INITIAL LUMENS 1-LAMP 2-LAMP
13W
350
425
Push Button Test Switch
4-pin PL CF
18W
400
550
4-pin PL CF
26W
475
650
TBTSBA-L
4-pin PL CF
32W
600
750
4-pin PL CF
42W
750
–
4-pin Long CF
18W
550
–
4-pin Long CF
24W
600
–
4-pin Long CF
36W
650
–
LADL20-N
EXAMPLE: LADL20-N
122
VOLTAGE WATTAGE
www.lightalarms.com
TYPE
LADL28 SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting fixtures 500 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Optional end caps available • Operating temperature 32°F to 122°F (0°C to 50°C) Mounting • Slim Design, for internal or external mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballast • Operates one 21W-28W T5 fluorescent lamp. Refer to compatible lamp chart for a complete list of lamps Lumen Output • (1) Lamp 325-500 Lumens Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 60Hz, 2.7W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL28 Series. The LADL28 fluorescent emergency ballast shall be a single steel housing selfcontained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL28 fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 500 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL28 Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ . Dimensions are approximate and subject to change.
1-1/4” 1.25” [3.18cm] 14-1/4” [36.2cm] 17.75 ” 1-1/4”” 1.25 [3.18cm]
COMPATIBLE LAMP CHART LAMP T5
ACCESSORIES (order as separate item) External mounting kit includes wire bundle cover
DIMENSIONS
T5
EC6
Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate)
PSW PSW1
Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
Charging Indicator Light
Replacement Test Switch
TBTSBB-L
VOLTAGE 120/277V
WATTAGE
INITIAL LUMEN 1-LAMP
14W
375
21W
425
T5
28W
500
T8
17W
350
T8
32W
475
4-pin PL CF
13W
325
4-pin PL CF
18W
425
4-pin PL CF
26W
475
Push Button Test Switch
ORDERING FORMAT SERIES LADL28
EXAMPLE: LADL28
www.lightalarms.com
123
TYPE
LADL30-N SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting units 3000 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Operating temperature 32°F to 122°F (0°C to 50°C) Mounting • External mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballast • Operates two 8W-54W T5/T5HO, two 17W-40W, one 17W-215W T8 through T12, two 13W-42W 4-pin compact, two 18W-50W or one 18W-55W 4-pin long compact fluorescent lamps Lumen Output • (1) Lamp 825-3000 Lumens • (2) Lamps 900-3000 Lumens per lamp Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 60Hz, 5.1W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL30-N Series. The LADL30-N fluorescent emergency ballast shall be a single steel housing self-contained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL30-N fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 3000 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL30-N Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ .
ACCESSORIES (order as separate item) Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate)
PSW PSW1
Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
Charging Indicator Light
Replacement Test Switch
TBTSB-L
Push Button Test Switch
ORDERING FORMAT SERIES
OPTIONS
LADL30-N
Blank= Standard Unit -DL= Damp location Listed
EXAMPLE: LADL30-N
124
DIMENSIONS
Dimensions are approximate and subject to change.
Length: B[41.27cm] Length 16-1/4”
Center: A LengthMounting 16-1/4” [41.27cm]
HeightHeight: 1-3/4” C [4.44cm] Width: D Width 5-1/2” [13.97cm]
COMPATIBLE LAMP CHART LAMP T5 T5 T5 T5HO T5HO T8 T8 T12 T12 T8 T12 T12 4-pin PL CF 4-pin PL CF 4-pin PL CF 4-pin PL CF 4-pin PL CF 4-pin Long CF 4-pin Long CF 4-pin Long CF 4-pin Long CF 4-pin Long CF 4-pin Long CF
www.lightalarms.com
VOLTAGE 120/277V
WATTAGE 14W 21W 28W 39W 54W 17W 32W 20W 40W 59W 110W 215W 13W 18W 26W 32W 42W 18W 24W 36W 40W 50W 55W
INITIAL LUMENS 1-LAMP 2-LAMPS 1150 1750 2350 2700 2900 1100 2950 875 2250 2800 2950 3000 825 1100 1500 2200 2450 1250 1750 2200 2350 2250 2500
1200 1800 2425 2850 3000 1150 3000 900 2400 – – – 900 1200 1600 2300 2500 1400 1900 2300 2400 2400 –
TYPE
LADL32 SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting units 500 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Low profile steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Optional end caps available • Operating temperature 68°F to 122°F (20°C to 50°C) Mounting • Internal or external mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • One 17-40W (2’-4’) T8, T10, T12 or one 28W (2’-4’) T5, T8, 40W Biax (Long CFL), or 50W Biax (Long CFL) fluorescent lamp Lumen Output • (1) Lamp 375-500 Lumens Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 2.5W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL32 Series. The LADL32 fluorescent emergency ballast shall be a single steel housing selfcontained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL32 fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 500 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL32 Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ .
DIMENSIONS
Dimensions are approximate and subject to change.
Length: B Length 10” [25.4cm]
Mounting Center: A Center 8-7/8” [20.32cm] Mounting Center 13.64” [33.34cm]
Height 1-1/4” Height: C [2.54cm]
ACCESSORIES (order as separate item) End Caps
External mounting kit includes wire bundle cover
Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate) Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
Width: D Width 2” [5.08cm]
EC6 PSW PSW1 Charging Indicator Light Push Button Test Switch
TBTSBA-L
Replacement Test Switch
ORDERING FORMAT SERIES LADL32
COMPATIBLE LAMP CHART LAMP F17 T8 F28 T8
VOLTAGE 120/277V
WATTAGE
INITIAL LUMEN 1-LAMP
17
450
28
460
F32 T8
32
475
28W T5
28
500
F15 T12
15
375
F20 T12
20
425
F40 T12
40
450
40W Long Compact
40
450
40W Circling
40
450
EXAMPLE: LADL32
www.lightalarms.com
125
TYPE
LADL540 SERIES
CATALOG #
Convert new or existing fluorescent fixtures into emergency lighting fixtures 1300 lumen emergency ballast
NOTES
FEATURES
SPECIFICATIONS
Housing • Steel housing contains, battery, battery charger, transfer circuit and high frequency inverter • Optional end caps available • Operating temperature 32°F to 122°F (0°C to 50°C) Mounting • Internal or external mounting to a fluorescent fixture Lamp Type Operation (refer to Ballast/Lamp Reference Chart for specific lamp type) • Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts • Operates one 8W-54W T5/T5HO, one 17W-40W T8 through T12, one 13W-42W 4-pin compact or one 18W-50W 4-pin long compact fluorescent lamps Lumen Output • (1) Lamp 700-1300 Lumens Electronics • Can be wired to operate switched, un-switched or normally off fixtures without affecting normal operation • Will cold start and illuminate lamps • Fully Automatic solid state charger • High capacity, automatic, dust-tight instantaneous transfer relay • Low voltage disconnect prevents over discharge of battery • Automatic brownout protection • Battery connector prevents battery discharge during installation Controls • Red charger monitor LED indicates charging of the battery and AC present • Momentary test switch allows for quick operational check of entire system Sealed Maintenance-Free Battery • Nickel-Cadmium battery • Provides 90 minutes of emergency operation Power Requirements • Dual voltage 120/277VAC, 60Hz, 2.7W Approvals • UL 924 Standards • Damp location listed Warranty (subject to proper installation and maintenance) • Ballast has a five year full warranty
Supply and install Lightalarms® LADL540 Series. The LADL540 fluorescent emergency ballast shall be a single steel housing selfcontained unit including a sealed maintenance-free Nickel-Cadmium battery, battery charger, transfer circuit and high frequency inverter. The unit shall be rated 120/277VAC, 60 Hz and be UL924 listed. The LADL540 fluorescent emergency ballast, sealed dust-tight relay inverter charger transfer circuit shall be of a solid state design being automatic and instantaneous capable of supplying an initial 1300 lumens output to cold start, operate switched, un-switched or normally off fixtures without affecting normal operation. The battery shall supply emergency operation for a minimum of 90 minutes and shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with, red charger monitor LED indicates charging of the battery and AC present to unit as well as a momentary test switch allows for quick operational check of entire system. Every LADL540 Series unit shall be fully warranted for five years, subject to proper installation and maintenance. UL listed to standard 924, complies with NEC, Life Safety Code and OSHA requirements. Unit shall be Lightalarms® catalog number_______________________ .
DIMENSIONS
Dimensions are approximate and subject to change. 1-3/20” 1.15 ” [2.92cm] Length 21-1/2” 21.5”[54.61cm] 1-2/9”
1.22 ” [3.09cm]
COMPATIBLE LAMP CHART LAMP
INITIAL LUMEN 1-LAMP
14W
700
21W
850
T5
28W
1100
T5HO
39W
1200
T5HO
54W
1300
EC6
T8
17W
950
T8
32W
1100
Remote Test Switch (Metal faceplate) Remote Test Switch (Plastic faceplate)
PSW PSW1
T12
20W
900
T12
40W
1200
13W
800
Recommended for inaccessible locations. Test switch and charging indicator on a single mounting plate.
Charging Indicator Light
4-pin PL CF 4-pin PL CF
18W
950
4-pin PL CF
26W
975
4-pin PL CF
32W
1025
4-pin PL CF
42W
1075
4-pin Long CF
18W
925
4-pin Long CF
24W
950
SERIES
4-pin Long CF
36W
1025
LADL540
4-pin Long CF
40W
1050
4-pin Long CF
50W
1100
External mounting kit includes wire bundle cover
TBTSB-L
Replacement Test Switch
ORDERING FORMAT
EXAMPLE: LADL540
126
Push Button Test Switch
www.lightalarms.com
120/277V
WATTAGE
T5
ACCESSORIES (order as separate item)
T5
VOLTAGE
TYPE
EPC-1-L SERIES
CATALOG #
Emergency Transfer Switch for Generator Supplies Power to Switched Lighting Fixtures
NOTES
FEATURES
SPECIFICATIONS
Housing • Thermoplastic UL94-5VA • Compatible with standard, energy-saving, dimming and electronic AC ballasts1 Mounting • Wall and ceiling mount Lamp Types • Will operate incandescent and fluorescent lamp types in the designated circuit for the duration of the generator supply2 (does not operate LED lamp types) Lumen output • Full light output • Allows auxiliary generator power on a switched fixture. Power Requirements • Dual Voltage 120/277V 60hz Approvals • UL924 Listed • Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Warranty (subject to proper installation and maintenance) • Unit has a five year warranty
The Lightalarms® EPC-1-L Emergency Transfer Switch allows the use of auxiliary generator power on a switched fluorescent fixture in power failure situations. The EPC-1-L senses the loss of normal AC power and switches the AC ballast to the auxiliary generator supply. The EPC-1-L will operate the lamps at full light output for as long as the generator is able, and will work in conjunction with any fluorescent lamp type and fixture on the generator circuit. Dimming ballasts require one EPC-1-L for each hot lead. Load dimming required one dimmer for the regular load and another one for time emergency load.
1 2
Mechanical Specifications: • Mounts in 4-11/16” Junction Box with single gang plaster ring • UL94-5VA Rating • Shipping Weight: 8 oz • Temperature: 32˚F - 140˚F (0˚F - 60˚F) | Color : White • Flush Mounted Size: 4-3/4” x 2-3/4” x 1/4” • Body Size: 2-7/8” x 1-3/4” x 1-3/4”
Excluding LED’s hen using EPC-1 to control more than 10 emergency ballasts with a high corrective W power factor capacitor, consult factory for more information regarding inrush currents.
DIMENSIONS
Dimensions are approximate and subject to change. EPC-1 Flush Mount Ceiling Installation 2” [5.08cm] 2”
Emergency Operation The EPC-1-L will operate any lamp type in the designated fixture for the duration of the generator supply
2” [5.08cm] 2”
1/2” Single Gang Plaster Ring Included in the product package
Initial Illumination The EPC-1-L will operate the designated lamp at full light output Weight 8 oz Approval UL924 Listed
Plastic is UL94-5VA flame rated 1-3/4” and can be mounted above the 1-3/4” suspended ceiling. [2.54cm]
2-7/8” 2-7/8” [5.08cm]
Electrical Specifications: • Model EPC-1-L-120/277V • 120V or 277V Sensing Input • 120V or 277V Load • 1800W Incandescent Load Rating at 120V • 1500W Incandescent Load Rating at 277V • N.C. Contact • UL924 Listed • 20 Amp Ballast Load Rating
UL ®
WIRING DIAGRAMS
UTILITY POWER
TEST
EMERGENCY POWER
SWITCH
It is recommended to number field wiring exactly the same, with numbers provided.
NOTE: Regular room lighting load does not affect EPC-1-L current rating. Room switch is only used to control EPC-1-L 10 mA relay current coil, and regular lighting load. Regular line HOT connected to breaker and EPC-1-L is only drawing milli amps to sense if normal power is available.
www.lightalarms.com
127
Inverter Systems
LOW CAPACITY MINI INVERTER Interruptible Unit Equipment 35W or 55W
MINI-INVERTER Interruptible Unit Equipment 125, 250, 400 or 720W
LIGHT SUPPORT POWER INVERTER SYSTEMS Feature & Benefits
LIGHT SUPPORT POWER INVERTER SYSTEMS COMPACT Series 500VA-2000VA
LIGHT SUPPORT POWER INVERTER SYSTEMS IPS Single Phase Series 1500VA-16.7KVA
130-131
132-133
134-135
136-137
138-139
LIGHT SUPPORT POWER INVERTER SYSTEMS FTC Single Phase Series 1500VA-16.7KVA
LIGHT SUPPORT POWER INVERTER SYSTEMS 3FTC Single Phase Series 4.8KVA-50KVA
LIGHT SUPPORT POWER INVERTER SYSTEMS FTC3R & 3FTC3R Series Outdoor
LIGHT SUPPORT POWER INVERTER SYSTEMS Options
LIGHT SUPPORT POWER INVERTER SYSTEMS Control Panel & Display Functions
140-141
142-143
144
145
146
LIGHT SUPPORT POWER INVERTER SYSTEMS System Request Data Sheet 147
www.lightalarms.com
129
LOW CAPACITY MINI INVERTER SERIES Interruptible Unit Equipment 32W or 55W
FEATURES
SPECIFICATIONS
Housing • Heavy-duty steel cabinet • White baked on powder paint coating provides scratch and corrosion resistance Mounting • Surface mount • Recessed T-Bar (plenum rated)
Supply and install Lightalarms® Low Capacity Mini Inverter Series.
Lamp Types Operated • LED • Incandescent • Fluorescent • Operates switched, normally-on or normally-off fixture types, incandescent, LED, fluorescent and ballast combinations, including triac dimmable ballasts Load Capacity • 32W, 55W • Allows for remote mounting of the emergency fixtures at distances of up to 1000 feet • May accept load when load feature power factor range from 0.44 lead to 0.44 lag Electronics • True sine wave inverter • Temperature compensated charger • Low battery voltage disconnect • Unit comes standard with electronic lockout and brownout circuits Controls • Control panel with momentary test switch, AC-On, Charger-On and Inverter-On LED indicators Sealed Maintenance-Free Battery • 12V oversized Valve Regulated Lead-Calcium (VRLA) battery • Provides 90 minutes of emergency operation Power Requirements • Choice of voltage: 120V in/120V out or 277V in/277V out operation, 60Hz Approvals • UL924 Standard • Meets or exceeds all National Electric Codes and Life Safety Code Emergency Lighting Requirements Warranty (subject to proper installation and maintenance) • Unit has a 3 year full warranty (excluding lamps and fuses) • Battery has a 3 year full, plus an additional 3 year pro-rata warranty
Emergency lighting shall be provided by inverter unit equipment designed to operate designated incandescent, fluorescent and LED fixtures on emergency power at their full nominal lumen rating during the full 90 minutes of emergency discharge cycle. System output will be rated at watts for 90 minutes. The system’s voltage rating shall be 120 / 277 VAC input/output. The inverter unit shall allow for connected emergency fixture(s) to be normally-on, normallyoff, switched or triac dimmable ballasts without affecting lamp operation during a power failure. Upon utility power loss, the inverter unit shall deliver 100% of its rated output to the emergency fixtures regardless of the local switch or dimmer position, and will provide power to emergency fixtures at distances of up to 1000 feet. The housing shall be manufactured with a white baked-on powder coat paint finish. The unit’s electronics shall include a self-contained inverter section with a fully automatic, thermal compensating dual mode battery charger, AC lockout feature, low voltage battery disconnect, DC overload, short circuit and brownout protection as standard. The unit shall utilize a sealed Lead-Calcium battery with a 10-year design life. The inverter system shall be UL 924 Listed and labeled. The unit shall be covered under a 3-year warranty on the electronics and battery plus an additional 3-year pro-rata warranty on the battery. Unit shall be Lightalarms® catalog number . SPECIFICATIONS TRANSFER TIME Less than 1 second VOLTAGE REGULATION ON EMERGENCY: +/- 5% FREQUENCY REGULATION ON EMERGENCY: 60 Hz +/- 0.5% LOAD POWER FACTOR RANGE: • 0.44 lead to 0.44 lag OPERATING TEMPERATURE: 68° to 86°F (20° to 30°C)
All Lightalarms® inverter products receive 100% quality inspection before shipment to insure proper and satisfactory operation.
130
www.lightalarms.com
TYPE
LOW CAPACITY MINI INVERTER SERIES
CATALOG #
NOTES
ELECTRICAL CHARACTERISTICS & DIMENSIONS SYSTEM TYPE
POWER RATING
SINE WAVE
INSTALLATION
CABINET DIMENSIONS W” H” D”
NO. OF BATTERY
WEIGHT 120V & 277V
LMILC32-S
32W/VA
Yes
Surface mount
14-3/4”
6-7/8”
3-1/8”
1
14 lbs
LMILC32-T
32W/VA
Yes
Recessed T-bar
23-7/8”
6-1/4”
4”
1
15 lbs
LMILC55-S
55W/VA
Yes
Surface mount
14-3/4”
6-7/8”
4-3/8”
1
18 lbs
LMILC55-T
55W/VA
Yes
Recessed T-bar
23-7/8”
6-1/4”
4”
1
19 lbs
NOTE: For wiring diagram, please refer to instruction sheets.
POWER CONSUMPTION AND UNIT RATING MODEL NUMBER
INPUT RATING
EMERGENCY POWER AVAILABLE FOR LOAD (90MIN)
LMILC32
41W/VA
32W
LMILC55
64W/VA
55W
ORDERING INFORMATION SERIES LMILC
CAPACITY 32= 32W/VA 55= 55W/VA
VOLTAGE IN/OUT BLANK= 120/277VAC
BATTERY TYPE BLANK= Lead-Calcium
MOUNTING -S= Surface mount housing -T= Plenum rated ceiling T-grid mount housing
EXAMPLE: LMILC32-S
www.lightalarms.com
131
MINI INVERTER SERIES Interruptible Unit Equipment Standard with Non-Audible Improved Self-Diagnostics Circuitry
FEATURES
SPECIFICATIONS
Housing • 14-Gauge Steel • White semi-gloss powered-coat paint finish Mounting • Surface mount • Optional recessed T-Bar (125W unit only) Lamp Types Operated • LED • Incandescent • Fluorescent • Operating switched, normally-on or normally-off fixture types • Incandescent, LED, fluorescent lamps and ballast combinations, including triac dimmable ballasts (consult factory if 0-10V or DALI dimming) Load Capacity • 125W, 250W, 400W or 720W • Line voltage allows for remote mounting of the emergency fixtures at distances up to 1000 feet • May accept load to it’s full capacity when load feature power factor of 0.9 for 250W model and 0.8 for 125, 400 and 720W model Electronics • High-efficiency pure sine wave inverter at 250W capacity or higher • Temperature compensated charger • Replaceable output fuse protection • Low battery voltage disconnect • Unit comes standard with electronic lockout and brownout circuits Controls • Standard with a non-audible self diagnostic/charger is fully self-contained, fully automatic microcontroller- based system • Optional audible auto diagnostic available • Standard lighting control override for 0-10V dimming systems Nexus® Option • Units equipped with NEXUS® self-testing monitoring system circuitry shall selftest, in accordance with NFPA101, Life Safety Code minimum 30 seconds every 30 days, 30 minutes every six months and 90 minutes annually as well as keep a history of all testing logs, plus feature a real-time diagnoses, as well as, be able to locate exact fixture location while notifying service personnel to the status of the fixture via email notification. Nexus® system interface with an improved minimum load lost detection of 10% Sealed Maintenance-Free Battery • 12V oversized Valve Regulated Lead-Calcium (VRLA) battery • Provides 90 minutes of emergency operation Power Requirements • Choice of Voltage 120V in/120V out or 277V in/277V out operation, 60Hz
Supply and install Lightalarms® Mini Inverter Series. Emergency lighting shall be provided by inverter unit equipment designed to operate designated incandescent, fluorescent and LED fixtures on emergency power at their full nominal lumen rating during the full 90 minutes emergency discharge cycle. System output will be rated at watts for 90 minutes and provide used output connections to the load. The system’s voltage rating shall be VAC input/output. The inverter unit shall allow for connected emergency fixture(s) to be normally on, normally off, switched or triac dimmable ballasts without affecting lamp operation during a power failure. Upon utility power loss, the inverter unit shall deliver 100% of its rated output to the emergency fixtures regardless of the local switch or dimmer position, and will provide power to emergency fixtures at distances of up to 1000 feet. The housing shall be manufactured using 14-gauge steel with a white baked-on powder coat paint finish. The unit’s electronics shall include as standard, non-audible self-diagnostics, a self-contained inverter section with a fully automatic, thermal-compensating variable-rate battery charger, AC lockout feature, low voltage battery disconnect, DC overload, short circuit and brownout protection as standard. The unit shall utilize a sealed Lead-Calcium battery with a 10-year design life. The inverter system shall be UL 924 Listed and labeled. The unit shall be covered under a 3-year full warranty on the electronics, against defects in material or workmanship. The battery includes a 3 year full, plus a 7 year pro-rata warranty. Unit shall be Lightalarms® catalog number . SPECIFICATIONS TRANSFER TIME Less than 1 second VOLTAGE REGULATION ON EMERGENCY: +/- 3% FREQUENCY REGULATION ON EMERGENCY: 60 Hz +/- 1% LOAD POWER FACTOR RANGE: • 250W model: .9 leading to .9 lagging • 125, 400 & 720W models: 8 leading to .8 lagging OPERATING TEMPERATURE: 68° to 86°F (20° to 30°C)
Approvals • UL924 Standard • Meets or exceeds all National Electric Code and Life Safety Code Emergency Lighting Requirements Warranty (subject to proper installation and maintenance) • Unit has a 3 year full warranty (excluding lamps and fuses) • Battery has a 3 year full, plus 7 year pro-rata warranty All Lightalarms® inverter products receive 100% quality inspection before shipment to insure proper and satisfactory operation.
REPLACEMENT BATTERY LMIU-125: 860.0024-L LMIU-250: 2X 860.0024-L LMIU-400: 2X 860.0043-L LMIU-720: 2X 860.0096-L
132
www.lightalarms.com
TYPE
Interruptible Unit Equipment 125W, 250W, 400W or 720W Standard with Non-Audible Improved Self-Diagnostics Circuitry & Lighting Control Override
CATALOG #
NOTES
ELECTRICAL CHARACTERISTICS & DIMENSIONS POWER RATING
SINE WAVE
INSTALLATION
CABINET DIMENSIONS W” H” D”
NO. OF BATTERY
WEIGHT 120V & 277V
WEIGHT W/O BATTERY 120V & 277V
125W
Modified
T-Bar
24”
6.5”
8”
1
43 lbs
20 lbs
125W
Modified
Wall
16.5”
12.2”
7.3”
1
41 lbs
18.5 lbs
250W
Pure
Wall
27”
12.2”
7.3”
2
76 lbs
30 lbs
400W
Pure
Wall
24”
10.5”
20”
2
128 lbs
50 lbs
720W
Pure
Wall
24”
14.5”
20”
2
185 lbs
72 lbs
NOTE: For wiring diagram, please refer to instruction sheets.
POWER CONSUMPTION AND UNIT RATING MODEL NUMBER LMIU-125 LMIU-250 LMIU-400 LMIU-720
AC SPECS 120 / 277VAC 120 / 277VAC 120 / 277VAC 120 / 277VAC
90MIN
1.15 / 0.50 Amps 2.28 / 0.99 Amps 3.73 / 1.62 Amps 6.90 / 2.99 Amps
EMERGENCY POWER AVAILABLE FOR LOAD 2H 3H
125W 250W 400W 720W
83W 167W 300W 480W
62W 125W 200W 360W
4H
47W 94W 150W 270W
ORDERING INFORMATION SERIES LMIU
CAPACITY -125= 1 25W -250= 2 50W -400= 4 00W -720= 7 20W
VOLTAGE IN/OUT BLANK= 120/120VAC or 277/277VAC
DIAGNOSTIC FEATURE Blank= Includes Improved Self-Diagnostics (non-audible)1 -ID= Improved Self-Diagnostics (audible)1 -NEX= Nexus® wired -NEXRF= Nexus® wireless
OPTIONS -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -SAC= Service alarm contact1 -T= Recessed T-Bar mounting (125W unit only)
1
1
Minimum load required: 10% of unit capacity
S ervice alarm contact (SAC) shall provide a 24V signal, the charger board will indicate a fault by choosing a contact. Not available with 720 capacity
EXAMPLE: LMIU-720
www.lightalarms.com
133
Light Support Power Inverter Systems Feature
HIGHLIGHTS
FEATURES
Performance • The Light Support Power Systems works with any type of lighting load to provide full light output for minimum 90 min. It is designed to support incandescent, fluorescent, HID*, quartz re-strike or halogen lamps. It will work into these loads at cold starts for all normally off circuits or normally on circuits. *except IPS systems True Sine Waveform • Using a solid-state, pulse width modulation (PWM) inverter the systems produce pure sinusoidal output waveform with less than 3% maximum Total Harmonic Distortion (THD) for linear loads. Microprocessor and crystal controlled. Reliability • The product is third generation inverter technology. Proven solid design with double ratings of all critical components. LVD (Low Voltage Disconnect) for long power outages eliminates battery drain. Batteries • Front access connections for easy installation significantly reduce the footprint, installation and maintenance time while increasing safety. Automatic restart and recharge upon restoration of utility. Approvals • UL listed to UL924. Meets UL924, NFPA101, NFPA70, NFPA 110, OSHA, UBC, SBCCI. • N.Y. City approved. Applications • Light Support Power Systems can be used in almost every type of building, especially in architecturally sensitive applications or when maintenance costs and individual testing of unit equipment becomes very significant. Our systems are designed to work with power factor corrected as well as the most recent T5 and T5-HO electronic ballasts. Options • A full range of options such as integrated output circuit breakers, bypass relays, dry contacts, etc., makes Light Support Power Systems an industry leader in emergency lighting central systems page 147.
Self-Diagnostic/Self-Testing • Programmable monthly and annual self-testing. Proven self-diagnostic with over 120 parameters stored in separate memory logs for Test, Event and Alarm. Microprocessor monitoring and control. Low heat dissipation • Very low heat loss technology in normal operating mode (see specifications for exact values). Convection cooling in normal mode with forced air during emergency mode. Battery cabinets: convection cooling only. Maximum Efficiency • Highest efficiency in the industry, 98% at 100% load with no requirement for cooling in normal operating mode. • Low input harmonic distortion