Data Sheet

13 downloads 5765 Views 339KB Size Report
5 x 20mm Medium Time-Delay Glass Tube Fuses. GMC Series. 0711 BU- SB11757. Page 1 of 2. Data Sheet 4395. Description. • Medium time-delay, low ...
Effective May 2017 Supersedes July 2011

Technical Data 4395

GMC

HALOGEN

HF Pb FREE 5 mm x 20 mm Medium time-delay glass tube fuses Agency information • • • • •

UL Listed, Guide JDYX, File E19180, 63mA-6.3A UL Recognized Card: (7A-10A) Guide JDYX2, File E19180 CSA Certified, Class 1422-01, File E65063, 63mA-6.3A MITI Approval, 1A-10A KC-Mark: Certificate SU05011-4001 (63mA~250mA); SU05011-4002 (300mA~800mA); SU05011-4003 (1A~3.15A); SU05011-4004 (3.5A~6.3A)

Ordering Product features • • • • •

Specify packaging code prefix, product number and option code suffix For RoHS compliant version (suffix “-R”), drop mA or A from product code (e.g., GMC-2-R)



Medium time-delay, low breaking capacity Available with optional axial leads 5 mm x 20 mm physical size Glass tube, nickel-plated brass endcap construction Designed to UL/CSA 248-14



Rated Current 63mA - 10A

Product Number GMC-63mA GMC-80mA GMC-100mA GMC-125mA GMC-150mA GMC-160mA GMC-200mA GMC-250mA GMC-300mA GMC-315mA GMC-400mA GMC-500mA GMC-600mA GMC-630mA GMC-700mA GMC-750mA GMC-800mA GMC-1A GMC-1.25A GMC-1.5A GMC-1.6A GMC-2A GMC-2.5A GMC-3A GMC-3.15A GMC-3.5A GMC-4A GMC-5A GMC-6A GMC-6.3A GMC-7A GMC-8A GMC-10A

Voltage Rating Vac 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 125 125 125 125 125 125 125 125

Interrupting Rating (Amps)* 250Vac 125Vac 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 35 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 100 10,000 10,000 10,000 10,000 10,000 10,000 200 200 200

Electrical Characteristics % of Amp Rating Opening Time 100% None 135% 60 minutes maximum 200% 2 minutes maximum

Typical DC Cold Resistance (Ω)** 10.350 4.775 3.400 2.555 2.295 1.395 0.965 0.838 0.685 0.615 0.335 0.282 0.246 0.213 0.213 0.180 0.156 0.098 0.076 0.067 0.043 0.035 0.026 0.025 0.022 0.019 0.014 0.013 0.012 0.012 0.009 0.007

Typical Pre-Arc I2t AC† 0.0027 0.0050 0.0094 0.014 0.022 0.022 0.032 0.046 0.081 0.081 0.18 0.41 0.60 0.66 0.85 0.85 0.85 1.8 3.4 5.4 5.8 8.9 13 19 23 25 36 58 88 110 150 200 300

Maximum Voltage Drop (mV)‡ 1400 1400 1200 1000 800 730 650 490 580 480 510 370 360 360 340 320 290 250 200 190 160 130 130 130 130 130 120 120 120 120 120 110 110

* Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC. ** DC Cold Resistance (Measured at