Documentation - SDMO

34 downloads 597 Views 5MB Size Report
A manual back-up pump. Extended use possible without having to top up the diesel. This is particularly well suited for use in isolated areas. Electronic regulation.
PPR-IN-DO-EN-231

Power Products

Energy Solutions Provider

50HZ 60HZ 6kVA-715kVA 11kW-600kW

AN ENERGY SOLUTION SDMO is renowned as one of the top designers and manufacturers of generating sets worldwide. SDMO’s single-industry strategy enables it to offer the largest range on the market conforming to the most stringent standards. Its ranges of products and services undergo continuous improvement, allowing them to meet even the most exacting energy requirements. By relying on the proximity of its distribution network, SDMO can offer electricity solutions for all, anytime and anywhere. In addition to its role as an industrial manufacturer of generating sets, SDMO is now positioning itself as a serious energy supplier.

Energy Solutions Provider.

NATIONAL COVERAGE, AN INTERNATIONAL PRESENCE, THINK GLOBAL, ACT LOCAL. In order for SDMO to continue to grow and expand into new markets, it relies on: - a distribution network present in over 25 European countries, - 6 overseas subsidiaries, - 6 offi ces, - 7 sales offi ces and 3 regional divisions in France. The responsiveness of the company is based on its development of 5 storage platforms which, in co-operation with the subsidiaries, constitute an effi cient commercial network. The links forged with the Kolher group have strengthened SDMO’s standing amongst its customers through a strategy of synergistic installations.

2

SDMO expertise benefiting the Power Products range The Power Products standard range of products covers energy requirements from 5 to 3300 kVA, at 50 and 60 Hz, and benefits from all of SDMO's generating set expertise and market knowledge using specialist teams and cutting edge equipment.

Research and development Design office

Laboratory

A team of experts dedicated to designing generating sets.

Cutting edge techniques promoting innovation.

The teams from the standard design office are constantly being updated on new 3D modelling tools and tools for calculating structures and constraints.

Backed by its expertise in the energy sector, the SDMO laboratory tests, analyses and suggests adapted solutions to remain at the cutting edge of innovation. It has gained ISO 17 025 accreditation

Production tools Ultra-modern factory

Production tools

Covering more than 38,000 m2, the premises offers highperformance operational tools.

The teams of specialists in this department ensure careful monitoring of product assembly.

3

POWER products Product advantages

An adapted "product" response SDMO does not compromise when it comes to the quality of its products and their compliance with standards. They are designed to meet even more demanding criteria in terms of safety and use than those actually required by the directives. To reach these objectives, components are selected with care from partner manufacturers who are amongst the most well-known and safest on the market.

The balance is struck between power, extreme climate conditions and sound levels One of the most crucial points when designing generating sets is to be able to offer optimum power combined with a low sound level under climate conditions which may be extreme. SDMO has managed to find the perfect balance between these three factors thanks to an in-depth study carried out by experienced teams who have access to dedicated technical resources.

Demanding choices SDMO is committed to designing high-performance generating sets which offer a demanding standard of quality. To ensure this, SDMO takes great care when selecting materials and equipment and works closely with suppliers who are also market leaders. SDMO and its partners are constantly working together to develop the solutions of the future.

Reducing pollutant emissions As part of its Power Products range, SDMO has decided to offer generating sets equipped with engines which limit pollutant emissions. To differentiate these, SDMO has added the following suffixes: C3 = Stage 3A (50Hz/EC directive) / Tier 3 (60Hz /USA EPA standards) C2 = Stage 2 (50Hz/EC directive) / Tier 2 (60Hz /USA EPA standards)

4

POWER products Services

Competent, reliable and long-lasting installations A dedicated support team on hand to meet the needs of our distributor network across the entire range of SDMO products guarantees the optimum service life of our products.

Training centre

Ensuring the best possible response The SDMO training department aims to provide our distributors and their customers with the knowledge required to use and maintain our generating sets.

Spare Parts

Technical Support

While the hub of the spare parts management system is in Brest, SDMO draws on an international distribution network, ensuring it has the proximity to react promptly to customers' needs.

The after-sales service is able to respond to any technical questions or issues encountered with a generating set from the moment it is installed. It organises events on the ground and assists the distributors in their operations on a day-today basis.

An efficient, well-integrated network

The guarantee of reliability for our products

5

POWER products from 9 kVA to 21 kVA ADRIATIC range Kohler engine

Open version

K16

Three phase Specifications 50 Hz - 230 V

GENERATING SETS (1)

K9 K12 K16 K21

kVA Cos ɸ 0.8 PRP ESP (3)

(4)

Cons 3/4 L/h

8 11 15 19

9 12 17 21

2.0 2.5 3.7 4.6

Single phase Specifications 50 Hz - 230 V

GENERATING SETS (1)

K10M K13M K17M

kVA Cos ɸ 0.8 PRP ESP (3)

(4)

Cons 3/4 L/h

9 12 15

10 13 16

2.5 3.7 4.6

K21

Specifications 60 Hz - 277 V GENERATING SETS K9U K12U K16U K20U

(2)

kWe ISO 8528* ESP PRP (3)

(4)

Cons 3/4 L/h

7.8 10.8 14.8 17.7

8.5 11.8 16.3 19.4

2.5 3.3 4.5 5.2

General specifications Engine Engine type KDW1003 KDW1404 KDW1603 KDW2204

Alternator

CC

CC

Type

Dimensions

Weight(6)

Tank

3L 4L 3L 4L

1.0 1.4 1.6 2.2

ECP3-2S ECP3-1L ECP3-3L ECP28-1L

1.22X0.70X0.92 1.41X0.72X1.02 1.41X0.72X1.02 1.41X0.72X1.15

280 340 410 470

50 50 50 50

(L)

Specifications 60 Hz - 240 V GENERATING SETS K9UM K12UM K16UM K20UM

(2)

kWe ISO 8528* ESP PRP (3)

(4)

Cons 3/4 L/h

7.8 10.3 13.9 17.7

8.5 11.5 15.5 19.4

2.5 3.3 4.5 5.2

Open version(5) lxwxh (m)

(kg)

(L)

General specifications Engine Engine type KDW1003 KDW1404 KDW1603 KDW2204

(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V (2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V (3)PRP: main power available continuously with variable load for an unlimited time in accordance with ISO 8528-1.

6

Alternator

Open version (5)

CC

CC

Type

Dimensions

Weight(6)

Tank

3L 4L 3L 4L

1.0 1.4 1.6 2.2

ECP3-1L ECP3-3L ECP28-1L ECP28-VL

1.22X0.70X0.92 1.41X0.72X1.02 1.41X0.72X1.02 1.70X0.90X1.15

290 350 420 520

50 50 50 100

(L)

lxwxh (m)

(kg)

(L)

(4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service. (5)The dimensions and weights apply to a generating set specified in the price list, without options (6)Dry weight - without fuel * ISO 8528: powers specified in compliance with the legislation in force

power products from 9 kVA to 21 kVA ADRIATIC range

product plus points

K20UM

Highly resistant base frames and enclosures

The treatment and paint used on the enclosures and base frames ensures they can withstand corrosion and are resistant for a long time. Quality tests are regularly carried out to ensure this quality remains consistent (resistance maintained over 1000 hours in salt spray).

Specifications

Generating Generating sets sets

Enclosures with doubled walled base frame

Standard enclosures

Sound levels 50Hz

Sound levels 60Hz

50Hz

60Hz

Enclosures

Fuel tank (L)

Dimensions lxwxh

Weight (kg)

Fuel tank (L)

50Hz maximum run time (h)

60Hz maximum run time (h)

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

K9 K12 K16 K21

K9U K12U K16U K20U

M125 M126 M126 M126

50 50 50 50

1.48x0.76x1.03 1.75x0.78x1.24 1.75x0.78x1.24 1.75x0.78x1.24

400 510 580 650

93 93 93 93

46.7 36.7 25.1 20.2

35 27.8 20.7 17.9

86 85 90 92

71 69 74 76

57 56 61 63

65 64 67 69

Specifications Generating Generating sets sets

Enclosures with doubled walled base frame

Standard enclosures

Sound levels 50Hz

Sound levels 60Hz

50Hz

60Hz

Enclosures

Fuel tank (L)

Dimensions lxwxh

Weight (kg)

Fuel tank (L)

50Hz maximum run time (h)

60Hz maximum run time (h)

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

K10M K13M K17M

K9UM K12UM K16UM K20UM

M126 M126 M126 M127

50 50 50 100

1.75X0.78X1.24 1.75x0.78x1.24 1.75x0.78x1.24 2.08x0.96x1.42

460 530 600 800

93 93 93 230

36,7 25,1 20,2

35 27,8 20,7 17,9

85 90 91

69 74 75

56 61 62

65 64 67 68

7

Soundproofed version

K12

POWER products from 6 kVA to 44 kVA PACIFIC range Mitsubishi engine

T8K

T44K

Three phase Specifications 50 Hz - 230 V GENERATING SETS (7)

kVA Cos ɸ 0.8

PRP

Open version

(3)

1,500 rpm

3,000 rpm

T8K T12K T16K T22K T33K T44K T22C3 T33C3 T44C3 T9HK T12HK T15HK T20HK T27HK

7 11 15 20 30 40 20 30 40 -

ESP (4)

Specifications 60 Hz - 240 V

Cons 3/4 L/h

GENERATING SETS

1.7 2.5 3.4 4.7 6.0 7.3 4.7 6.6 7.8 2.6 4.2 4.2 5.5 6.3

T11U T16U T20U T30U T40U -

8 12 16 22 33 44 22 33 44 9 12 15 20 27

kWe ISO 8528*

PRP (3)

10 14 18 27 36 -

ESP (4)

General specifications Engine

Alternator

Cons 3/4 L/h

Engine type

CC

CC

3.2 4.2 5.6 8.2 8.7 -

L3E SD S3L2 SD S4L2 SD S4Q2 SD S4S SD S4S DT S4Q2 Z361SD S4S Z361SD S4S Z3DT61SD L2E SDH L3E SDH L3E SDH S3L2 SDH S4L2 SDH

3L 3L 4L 4L 4L 4L 4L 4L 4L 2L 3L 3L 3L 4L

1.0 1.3 1.7 2.5 3.3 3.3 2.5 3.3 3.3 0.6 1.0 1.0 1.3 1.8

11 16 20 30 40 -

(L)

Open version (5)

Type

Dimensions

Weights(6)

lxwxh (m)

(kg)

Fuel tank (L)

ECP3-2S ECP3-1L ECP3-1L ECP28-1L ECP28-VL ECO32-3S ECP28-1L ECP28-VL ECO32-3S FT2MBS FT2MBS FT2MBS ECP3-2L ECP28-2L

1.22X0.70X0.92 1.41X0.72X1.05 1.41X0.72X1.05 1.70X0.90X1.12 1.70X0.90X1.14 1.70X0.90X1.22 1.70X0.90X1.12 1.70X0.90X1.14 1.70X0.90X1.22 1.22X0.70X0.92 1.22X0.70X0.92 1.41X0.72X1.05 1.41X0.72X1.05 1.70X0.90X1.12

280 387 406 560 660 680 549 670 680 240 260 294 386 530

50 50 50 100 100 100 100 100 100 50 50 50 50 100

Single phase Specifications 50 Hz -230 V GENERATING SETS (1)

kVA Cos ɸ 0.8

PRP (3)

1,500 rpm

3,000 rpm

T6KM T9KM T12KM T17KM T25KM T17C3M T25C3M T8HKM T11HKM

5 8 11 16 23 16 23 -

ESP (4)

6 9 12 17 25 17 25 8 11

Specifications 60 Hz - 240 V

Cons 3/4 L/h

GENERATING SETS (2)

1.7 2.5 3.4 4.7 6.0 2.6 4.2

T8UM T11UM T16UM T20UM T30UM T40UM -

kWe ISO 8528*

PRP (3)

7 9 14 18 27 36 -

ESP (4)

General specifications Engine

Alternator

Cons 3/4 L/h

Engine type

CC

CC

2.2 3.2 4.2 5.6 8.2 8.7 -

L3E SD L3E SD S3L2 SD S4L2 SD S4Q2 SD S4S SD S4S SD S4S DT S4Q2 Z361SD S4S Z361SD L2E SDH L3E SDH

3L 3L 3L 4L 4L 4L 4L 4L 4L 4L 2L 3L

1.0 1.0 1.3 1.7 2.5 3.3 3.3 3.3 2.5 3.3 0.6 1.0

8 10 15 20 30 40 -

(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V (2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V (3)PRP: main power available continuously with variable load for an unlimited time in accordance with ISO 8528-1. (4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service.

8

(L)

Open version (5)

Type

Dimensions

Weights(6)

lxwxh (m)

(kg)

Fuel tank (L)

ECP3-2S ECP3-2S ECP3-2L ECP28-1L ECP28-VL ECO32-3S ECO32-3S 423L9 ECP28-VL ECO32-3S S20FS-130 ECP3-2L

1.22X0.70X0.92 1.22X0.70X0.92 1.41X0.72X1.05 1.41X0.72X1.05 1.70X0.90X1.12 1.70X0.90X1.14 1.70X0.90X1.14 1.70X0.90X1.22 1.70X0.90X1.12 1.70X0.90X1.14 1.22X0.70X0.92 1.22X0.70X0.92

280 280 396 452 580 710 710 730 590 710 220 280

50 50 50 50 100 100 100 100 100 100 50 50

(5)The dimensions and weights apply to a generating set specified in the price list, without options (6)Dry weight - without fuel (7)Also available in the following voltages: 220 V - 240 V * ISO 8528: powers specified in compliance with the legislation in force

power products from 6 kVA to 44 kVA PACIFIC range

OPTION DETAILS SDMO is offering a double wall base frame as an option

offering greater autonomy. With its double wall, the environment is protected against any possible fuel leak. It is the ideal option for use in isolated areas in particular.

T6KM

T33K with double wall base frame option

Generating Generating sets sets

Enclosures with doubled walled base frame

Standard enclosures

50Hz

60Hz

Enclosures

T8K T12K T16K T22K T33K T44K T22C3 T33C3 T44C3 T9HK T12HK T15HK T20HK T27HK

T11U T16U T20U T30U T40U -

M125 M126 M126 M127 M127 M127 M127 M127 M127 M125 M125 M126 M126 M127

Sound levels 50Hz

Sound levels 60Hz

Tank (L)

Dimensions lxwxh (m)

Weight (kg)

Tank (L)

50Hz maximum run time (h)

60Hz maximum run time (h)

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

50 50 50 100 100 100 100 100 100 50 50 50 50 100

1.48x0.76x1.03 1.75x0.78x1.24 1.75x0.78x1.24 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 1.48x0.76x1.03 1.48x0.76x1.03 1.75x0.78x1.24 1.75x0.78x1.24 2.08x0.96x1.42

390 557 554 790 890 920 780 900 920 360 380 442 534 752

93 93 93 230 230 230 230 230 230 93 93 93 93 230

54,7 37,2 27,4 48,9 38,3 31,5 48,9 34,8 29,7 35,8 22,1 22,1 16,9 36,5

29,1 22,1 41,1 28,0 26,4 -

86 87 88 86 90 92 87 90 91 94 95 95 95 97

71 69 71 69 72 74 70 73 74 79 80 78 79 80

57 58 58 57 60 62 58 61 62 65 66 65 66 68

63 64 65 66 69 -

Specifications Generating sets

Generating sets

Enclosures with doubled walled base frame

50Hz

60Hz

Enclosures

Tank (L)

Dimensions lxwxh (m)

Weight (kg)

Tank (L)

50Hz maximum run time (h)

60Hz maximum run time (h)

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

T6KM T9KM T12KM T17KM T25KM T17C3M T25C3M T8HKM T11HKM

T8UM T11UM T16UM T20UM T30UM T40UM -

M125 M125 M126 M126 M127 M127 M127 M127 M127 M127 M125 M125

50 50 50 50 100 100 100 100 100 100 50 50

1.48x0.76x1.03 1.48x0.76x1.03 1.75x0.78x1.24 1.75x0.78x1.24 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 2.08x0.96x1.42 1.48x0.76x1.03 1.48x0.76x1.03

390 390 544 630 820 940 940 960 820 940 340 400

93 93 93 93 230 230 230 230 230 230 93 93

54,7 37,2 27,4 48,9 38,3 35,8 22,1

42,3 29,1 22,1 41,1 28,0 26,4 -

86 87 88 86 90 87 90 94 97

71 69 71 69 73 70 73 79 82

57 56 58 57 61 58 61 65 68

68 63 65 65 66 69 -

Standard enclosures

9

Sound levels 50Hz

Sound levels 60Hz

Soundproofed version

Specifications

POWER products from 22 kVA to 300 kVA MONTANA range John Deere engine

J88K with TELYS control unit as an option

J250U with TELYS control unit as an option

Three phase Specifications 50 Hz - 400-230 V GENERATING SETS

Open version

(1)

kVA Cos ɸ 0.8

PRP (3)

J22 J33 J44K J66K J77K J88K J110K J130K J165K J200K J220C2 J275K J300K

20 30 40 60 70 80 100 118 150 182 200 250 273

ESP (4)

22 33 44 66 77 88 110 130 165 200 220 275 300

Specifications 60 Hz - 480-277 V

Cons 3/4 L/h

GENERATING SETS

5.0 5.0 7.5 12.0 12.0 14 16.5 18.5 25.0 31.3 34 42.6 42.6

J20U J30U J40U J60U J70U J80U J100U J120U J150U J175U J200U J250U

(2)

kWe ISO 8528*

PRP (3)

18 25 36 55 64 73 91 106 137 159 173 227

ESP (4)

20 28 40 60 70 80 100 117 150 175 190 250

General specifications

Cons 3/4 L/h 6.5 6.5 8.7 14.5 14.5 16 19.0 24.0 29.0 36.1 36.9 46.1

Engine

Engine type

CC

3029DF120 3029DF120 3029TF120 4045TF120 4045TF120 4045TF220 4045HF120 6068TF220 6068HF120-153 6068HF120-183 6068HF475 6068HFS77 6081HF001 6081HF001

3L 3L 3L 4L 4L 4L 4L 6L 6L 6L 6L 6L 6L 6L

Open version (5)

Alternator

CC (L)

2.9 2.9 2.9 4.5 4.5 4.5 4.5 6.7 6.7 6.7 6.7 6.7 8.2 8.2

Type ECP28-1L ECP28VL ECO32-3S 432M45 432L65 432L8 442VS45 442S7 442M95 462M3 462M5 462M5 462L6 462L9

Dimension

Weights(6) Fuel tank

lxwxh (m)

(kg)

(L)

1.70x0.90x1.22 1.70x0.90x1.22 1.70x0.90x1.22 1.87x0.99x1.36 1.87x0.99x1.36 1.87x0.99x1.36 1.95x1.08x1.33 2.37x1.11x1.48 2.37x1.11x1.48 2.37x1.11x1.48 2.40x1.11x1.48 2.40x1.11x1.48 2.90x1.30x1.70 2.90x1.30x1.70

720 740 820 1000 1110 1110 1240 1570 1640 1730 1790 1790 2170 2235

100 100 100 180 180 180 190 340 340 340 340 340 390 390

Single phase Specifications 50 Hz - 230 V GENERATING SETS

kVA Cos ɸ 0.8

PRP (3)

-

-

ESP (4)

-

Specifications 60 Hz - 240 V Cons 3/4 L/h

GENERATING SETS

-

J20UM J30UM J40UM J70UM

kWe ISO 8528*

PRP (3)

18 25 36 61

ESP

General specifications Cons 3/4 L/h

(4)

20 28 40 67

6.5 5.0 8.7 14.5

(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V (2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V (3)PRP: main power available continuously with variable load for an unlimited time in accordance with ISO 8528-1.

Engine

Engine type

CC

3029DF120 3029DF120 3029TF120 4045TF120

3L 3L 3L 4L

Open version (5)

Alternator

CC (L)

2.91 2.9 2.9 4.5

Type ECO28VL ECO32-3S 432M45 442VS45

Dimensions

Weights(6) Fuel tank

lxwxh (m)

(kg)

(L)

1.70X0.90X1.22 1.70x0.90x1.22 1.70x0.90x1.22 1.87x0.99x1.36

740 800 860 1240

100 100 100 190

(4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service. (5)The dimensions and weights apply to a generating set specified in the price list, without options (6)Dry weight - without fuel * ISO 8528: powers specified in compliance with the legislation in force

10

power products from 22 kVA to 300 kVA MONTANA range

OPTION DETAILS Base frame with 48-hour tank!

For improved maximum run time, opt for the double wall base frame with a large capacity integrated fuel tank: ideal for isolated areas. This option combines the need for autonomy with security, making it possible for all of the generating set's fluids to be held.

J200K with 48-hour tank option

Specifications Generating sets

Generating sets

Enclosures with double wall base frame

Standard enclosures

50Hz

60Hz

Enclosures

J22 J33 J44K J66K J77K J88K J110K J130K J165K J200K J220C2 J275K J300K

J20U J30U J40U J60U J70U J80U J100U J120U J150U J175U J200U J250U

M127 M127 M127 M128 M128 M128 M129 M226 M226 M226 M226 M226 M227 M227

Enclosures with 48-hour tank

Sound levels 50Hz

Sound levels 60Hz

Fuel tank (L)

Dimensions (lxwxh)

Weight (kg)

Tank (L)

50Hz maximum run time (h)

60Hz maximum run time (h)

Tank (L)

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

100 100 100 180 180 180 190 340 340 340 340 340 390 390

2.08X0.96X1.42 2.08X0.96X1.42 2.08X0.96X1.42 2.30X1.06X1.68 2.30X1.06X1.68 2.30X1.06X1.68 2.55X1.15X1.68 3.51X1.20X1.83 3.51X1.20X1.83 3.51X1.20X1.83 3.51X1.20X1.83 3.51X1.20X1.83 4.00X1.38X2.15 4.00X1.38X2.15

950 970 1040 1410 1530 1530 1640 2160 2230 2320 2390 2390 3150 3215

230 230 230 390 390 390 505 868 868 868 868 868 950 950

46.0 46.0 30.7 32.5 32.5 27.9 30.6 46.9 34.7 27.7 25.5 22.3 22.3

35.4 35.4 26.4 26.9 26.9 24.4 26.6 36.2 29.9 24 23.5 20.6

420 420 420 700 700 700 825 1630 1630 1630 1630 2130 2130

91 91 90 92 92 95 94 96 95 95 95 95 95

75 75 73 76 76 79 77 78 79 79 79 80 80

65 65 63 66 66 70 67 68 69 69 69 69 69

65 68 67 66 67 73 70 69 69 69 70 72

*Option not available for 60Hz generating sets

Specifications Generating sets

Generating sets

Enclosures with doubled walled base frame

50Hz

60Hz

Enclosures

Tank (L)

Dimensions lxwxh (m)

Weight (kg)

Tank (L)

60Hz maximum run time (h)

dB(A)@7m

-

J20UM J30UM J40UM J70UM

M127 M127 M127 M129

100 100 100 190

2.08X0.96X1.41 2.08X0.96X1.42 2.08X0.96X1.42 2.55X1.15X1.68

970 1020 1090 1630

230 230 230 505

35.4 35.4 26.4 26.9

68 68 67 67

Standard enclosures

11

Sound levels 60Hz

Soundproofed version

J100U

POWER products from 200 kVA to 700 kVA ATLANTIC range

Open version

Volvo engine

Three phase Specifications 50 Hz - 400-230 V GENERATING SETS (1)

kVA Cos ɸ 0.8

PRP (3)

V220C2 V275C2 V350C2 V375C2 V410C2 V440C2 V500C2 V550C2 V630C2 V700C2

Soundproofed version

V220C2

V410C2

200 250 318 341 376 400 455 500 573 650

ESP (4)

220 275 350 375 413 440 500 550 630 700

Specifications 60 Hz - 480-227 V

Cons 3/4 L/h

GENERATING SETS

31.7 42.6 50.6 50.6 57.0 63.3 69,2 75.4 85.2 94.5

V200U V250U V300U V350U V400U V450U V500UC2 V550UC2 V600UC2

(2)

kWe ISO 8528*

PRP (3)

182 227 273 319 364 409 455 500 546

ESP (4)

200 250 300 350 400 450 500 550 600

General specifications

Cons 3/4 L/h 35.2 45.7 52.8 65.5 72.4 78.4 88.8 97.1 105.7

Engine

Engine type

CC

TAD733GE TAD734GE TAD734GE TAD941GE TAD1343GE TAD941GE TAD1343GE TAD1344GE TAD1640GE TAD1345GE TAD1641GE TAD1642GE TAD1642GE TWD1643GE

6L 6L 6L 6L 6L 6L 6L 6L 6L 6L 6L 6L 6L 6L

Open version (5)

Alternator

CC (L)

7.2 7.2 7.2 9.4 12.8 9.4 12.8 12.8 16.1 12,8 16.1 16.1 16.1 16.1

Type 462M5 462L9 462L6 462VL12 472VS2 472VS2 472VS3 472VS3 472S5 472S5 472M7 472M7 472L9 491S4

Dimensions

Weights(6) Fuel tank

lxwxh (m)

(kg)

(L)

2.37X1.11X1.54 2.90X1.30X1.59 2.90X1.30X1.59 3.16X1.34X1.76 3.16X1.34X1.80 3.16X1.34X1.76 3.16X1.34X1.80 3.16X1.34X1.80 3.47X1.50X2.04 3.16X1.34X1.80 3.47X1.50X2.05 3.47X1.63X2.08 3.47X1.63X2.08 3.47X1.63X2.08

1850 2260 2200 2700 3206 2780 3190 3110 3490 3490 3620 3650 3780 3890

340 390 390 470 470 470 470 470 500 500 500 610 610 610

Specifications Generating sets

Generating sets

Enclosures with doubled walled base frame

50Hz

60Hz

Enclosures

Tank (L)

Dimensions lxwxh (m)

Weight (kg)

Tank (L)

V220C2 V275C2 V350C2 V375C2 V410C2 V440C2 V500C2 V550C2 V630C2 V700C2

V200U V250U V300U V350U V400U V450U V500UC2 V550UC2 V600UC2

M226 M227 M227 M228 M228 M228 M228 M228 M229 M228 M229 M230 M230 M230

340 390 390 470 470 470 470 470 500 470 500 610 610 610

3.51X1.20X1.83 4.00X1.38X2.15 4.00X1.38X2.15 4.48X1.41X2.43 4.48X1.41X2.43 4.48X1.41X2.43 4.48X1.41X2.43 4.48X1.41X2.43 5.03X1.56X2.44 4.48X1.41X2.43 5.03X1.56X2.44 5.03X1.69X2.66 5.03X1.69X2.66 5.03X1.69X2.66

2490 3190 3130 3830 3910 4030 4070 4080 4740 4220 4870 5300 5170 5410

868 950 950 1368 1368 1368 1368 1368 1770 1368 1770 1950 1950 1950

Standard enclosures

(1)Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V (2)Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V (3)PRP: main power available continuously with variable load for an unlimited time in accordance with ISO 8528-1. (4)ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service.

12

50Hz maximum run time (h) 27,4 22,3 27,0 27,0 24,0 21,6 19,8 23,5 22,9 20,6

60Hz maximum run time (h) 24,7 20,8 25,9 20,9 18,9 22,6 19,9 20,1 18,4

Sound levels 50Hz

Sound levels 60Hz

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

97 96 97 97 98 98 98 97 100 105

79 78 77 77 78 78 79 78 82 85

69 68 67 67 68 68 69 68 72 75

72 74 70 73 75 74 75 75 79

(5)The dimensions and weights apply to a generating set specified in the price list, without options (6)Dry weight - without fuel * ISO 8528: powers specified in compliance with the legislation in force (7) Also available in the following voltages: 415/240V – 380/220V

POWER products from 275 kVA to 715 kVA EXEL range

Three phase

Specifications 50 Hz - 400-230 V GENERATING SETS (1)

kVA Cos ɸ 0.8 PRP (3)

X300C3 X330C3 X500C3 X550C3 X650C2 X715C2

273 300 455 500 591 650

ESP (4)

300 330 500 550 650 715

Specifications 60 Hz - 480-277 V

Cons 3/4 L/h

GENERATING SETS

47,0 50,5 80,0 86,0 94,0 103,0

X275UC3 X300UC3 X450UC3 X500UC2 X550UC2 X600UC2

(2)

kWe ISO 8528* PRP (3)

250 273 409 455 500 546

ESP (4)

275 300 450 500 550 600

General specifications Engine

Cons 3/4 L/h

Engine type

CC

47.0 50.5 80 86 94 103

6R16000G10F/S 6R16000G20F/S 10V1600G10F/S 10V1600G20F/S 12V1600G10F/S 12V1600G20F/S

6 6 10 10 12 12

Open version (5)

Alternator CC (L)

10,50 10,50 17,5 17,5 21,0 21,0

Dimension

Weights(6)

lxwxh (m)

(kg)

Fuel tank (L)

3.16x1.13x1.80 3.16x1.13x1.80 3.47X1.63X2.07 3.47X1.63X2.07 3.47X1.63X2.07 3.47X1.63X2.07

3200 3300 4080 4210 4480 4510

470 470 610 610 610 610

Type 462L9 462VL12 472S5 472M7 472L9 491S4

Specifications Generating sets

Generating sets

Sound levels 50Hz

50Hz

60Hz

Enclosures

Tank (L)

Dimensions lxwxh (m)

Weight (kg)

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

X300C3 X330C3 X500C3 X550C3 X650C2 X715C2

X275UC3 X300UC3 X450UC3 X500UC2 X550UC2 X600UC2

M228 M228 M230 M230 M230 M230

470 470 610 610 610 610

4.48X1.41X2.43 4.48X1.41X2.43 5.03X1.69X2.66 5.03X1.69X2.66 5.03X1.69X2.66 5.03X1.69X2.66

4500 4500 5670 5800 6070 6100

100 100 108 108 108 108

80 80 88 88 88 88

70 70 78 78 78 78

75 75 81 83 84 85

Standard enclosures

(1) Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V (2) Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V (3) PRP main power available continuously with variable load for an unlimited number of hours annually in accordance with ISO 8528-1. (4) ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service.

Sound levels 60Hz

(5) The dimensions and weights apply to a generating set specified in the price list, without options (6) Dry weight - without fuel* ISO 8528: powers specified in compliance with the legislation in force

13

Soundproofed version

X330C3

X550C3

Open version

MTU engine

POWER products From 330 kVA to 700 kVA OCEANIC range

Open version

Doosan engine

Three phase Specifications 50 Hz 400-230 V GENERATING SETS (1)

kVA Cos 0.8 PRP (3)

D330 D440 D550 D700

Soundproofed version

D600U

D700

300 400 500 623

ESP

Specifications 60 Hz 480-227 V

Cons 3/4 L/h

GENERATING SETS (2)

(4)

330 440 550 686

kWe ISO 8528* PRP (3)

D300U D400U D500U D600U

47 65.1 81.3 99.8

272 363 454 545

ESP

General specifications

Cons 3/4 L/h

(4)

300 400 500 600

56 74.7 93.4 112.3

Engine Engine type

CC

P126TI-II P158LE P180LE P222LE-S

6L 8V 10V 12V

Alternator CC

Type

(L)

11.05 14.62 18.27 21.93

462VL12 472VS3 472M7 491S4

Open version (5) Dimensions lxwxh (m) 3.16x1.34x1.59 3.47x1.50x1.83 3.47x1.50x1.97 3.47x1.63x2.13

Weights(6)

Fuel tank

(kg)

(L)

2570 2910 3400 3870

470 500 500 610

Specifications Generating sets

Generating sets

Enclosures with doubled walled base frame

50Hz

60Hz

Enclosures

Fuel tank (L)

Dimensions lxwxh

Weight (kg)

Fuel tank (L)

50 Hz (h) maximum run time

60 Hz (h) maximum run time

LWA

dB(A)@1m

dB(A)@7m

dB(A)@7m

D330 D440 D550 D700

D300U D400U D500U D600U

M228 M229 M229 M230

470 500 500 610

4.48X1.41X2.43 5.03X1.56X2.44 5.03X1.56X2.44 5.03X1.69X2.66

3670 4090 4580 5330

1368 1770 1770 1950

29.1 27.2 21.8 19.5

24.4 23.7 19.0 17.4

101 102 101 105

82 82 82 85

72 72 72 75

75 75 75 80

Standard enclosures

(1) Also available in the following voltages: 415/240 V - 380/220 V - 220/127 V - 200/115 V (2) Also available in the following voltages: 440/254 V - 220/127 V - 208/120 V (3) PRP: main power available continuously under variable load for an unlimited number of hours annually, in accordance with ISO 8528-1. (4) ESP: Emergency Standby Power available for supplying emergency power in variable load applications in accordance with ISO 8528-1, no overload available for this service.

14

Sound levels 50Hz

Sound levels 60 Hz

(5)The dimensions and weights apply to a generating set specified in the price list, without options (6)Dry weight - without fuel * ISO 8528: powers specified in compliance with the legislation in force

POWER products from 8 kVA to 700 kVA

product plus points

X-PRESS range

Order directly by mail

Standard generating sets are held in stock

You can place your order directly by mail using the form attached to the stock list sent each week. Cut out the middle man: your order is registered and shipped in the quickest possible time.

Thirty 50 Hz models from 8 to 700 kVA and twenty-six 60 Hz models from 8 to 600 kW in the Power Products range are in stock worldwide and can be delivered to you within very short lead times. These generating sets are available in open or enclosed versions. Aftermarket options are available to order (silencers, differential protection, normal/emergency switches, Service First, etc.)

PLANNING

PRODUCTION

STORAGE

Ordering a generating set during the planning or production phase = shortest possible lead time

Ordering a generating set available on the platform = available immediately

50 Hz configuration available 8 to 220 kVA 4-pole circuit breaker Control unit Card for measurement Auto pack Prewiring for auto start-up CE label Silencer

275 to 300 kVA

300 to 700 kVA

open

enclosed

open

enclosed

open

enclosed

NEXYS

NEXYS

NEXYS

NEXYS

TELYS

TELYS

X Included

X

X Not available

60 Hz configuration available 11 to 275 kW three phase Circuit breaker Control unit Card for measurement Prewiring for auto start-up Silencer Analog pack

30 to 70 kW single phase

350 to 600 kW

open

enclosed

open

enclosed

open

enclosed

3 poles NEXYS

3 poles NEXYS

2 poles NEXYS

2 poles NEXYS

3 poles TELYS X

3 poles TELYS X

Included

X Not available

15

POWER products OPTION DETAILS

Modular generating sets, an adapted response

For each of its generating sets, SDMO offers a large range of options to facilitate maintenance operations, enhance user safety and provide solutions for specific use requirements or unusual environments.

Option specifications by range

ADRIATIC Protection of hot parts Diesel separator pre-filter Battery isolating switch Automatic pack Electronic regulation Automatic filling kit Drainage pump Analog measurements display Oversized alternator Air discharge duct 9dB(A) silencer in open version High autonomy double wall chassis Base frame with 48-hour tank

CEL02 FD05 EN16 CM302/CM403 EN01 FD08(3) EN04 CM307-CM407 X CN03

Standard CEL02: option code X: Not available. * for all the gensets except M125 canopy

(10)

FD02* X

PACIFIC

MONTANA

CEL02 FD05 EN16 CM302/CM403 EN01 FD08(3) EN04 CM307-CM407 AO001B(5) CN03

ATLANTIC

CEL02

EXEL

CEL02

CEL02

(1)

EN16 CM/302/CM403

EN16 CM302/CM403/CM404

(2)

(2)

FD08 EN04 CM307-CM407 AO001B(6) CN03

(10)

(3)

(5)

(5) (6)

AO001B(7) CN03

FD02 FD03

(1) Except V220C2 (2) Except for 3029 and 4045 engines (3) Not possible on 48-hour and double wall base frame (4) Standard in covered version set (5) Option not available for 3000 rpm and T30UM, T40U, T40UM, T44K generating sets (6) Option not available for J20UM, J30UM, J40U, J44K, J70U, J80U and J88K generating sets and on the covered version of the J220C2 set

X(9) CN03

(10)

(10)

FD02 X

CEL02 FD05 EN16 CM404 (2)

FD08

(3)

(10)

FD02* X

(2)

FD08

(3)

EN16 CM404

OCEANIC

X X

FD08(3) EN04 AO001B(8) CN03 (10)

FD02 X

(7) Option not available on the covered versions of V220C2, V600UC2 and V700C2 sets (8) Option not available for the D700 and on the covered versions of the D500U, D550 and D600U sets (9) Except on 10V1600 engine (10) 29 dB(A) and 40 dB(A) silencer available as an option

Analog measurements display

Air discharge duct

Battery isolating switch

(CM407)

(EN12/EN08/EN09)

(EN16)

Metal elbow-shaped box section which enables the air to be discharged from the top of the enclosure towards the front of the generating set.

Battery isolator rotary handle for easy isolation of the battery during genset storage.

This option enables the oil pressure and the water temperature to be displayed on the Nexys or Telys screen. In some cases, this is on an additional display.

16

power products OPTION DETAILS

More about options Protection of hot parts

Diesel separator pre-filter

(CEL02)

(FD05) This is a pre-filter enabling water contained in diesel to be removed, thereby improving the engine's protection.

Protective grille for hot parts (exhaust manifold) on the Diesel engine and rotating parts. This option ensures the user's safety during maintenance operations. Mandatory option within the European community (European directive).

Filter with interchangeable cartridge (EN02) Dry air filters with removable and interchangeable cartridges for dusty environments which can be removed and cleaned with blown air, if required. This option is required when the generating set is used in dusty environments.

Oversized alternator (AO001B) For use under heavy electrical or climate constraints, this option allows greater operating flexibility for a better guarantee of performance.

Automatic filling kit (FD08) This is an automatic kit for filling the tank from an external storage tank. It includes: - An electric pump with automatic control governed by a gauge with level contacts - A manual back-up pump Extended use possible without having to top up the diesel. This is particularly well suited for use in isolated areas.

Drainage pump (EN04-EN05) Manual oil drainage pump for easier servicing of the generating set during maintenance operations. Standard option on enclosed gensets.

Silencer on open version Electronic regulation

for "open" version generating sets, a choice of 3 noise reduction levels is available (9dB(A), 29dB(A), 40dB(A)), to meet the constraints of various installations.

(EN01) Electronic speed regulator with control unit enabling precise control of speed, and therefore the frequency, to +/- 1%. This regulator is factory fitted as standard on some engines. This option allows the quality of the signal to be improved for better operation of sensitive equipment.

Automatic pack (EN20) This includes a preheating resistor and a battery charger. It is an engine preheating device which uses an electrical resistor. Preheating is self-adjusting up to 200 KVA and thermostat-controlled for outputs above this. This option is ideal for generating sets used as back-up. It allows the coolant to be maintained at a temperature of 40°C to facilitate emergency start-up and save time when commissioning the generating set.

17

POWER products control units

NEXYS, TELYS, KERYS: exclusive to SDMO SDMO offers a unique range of specific control units: NEXYS, TELYS and KERYS. These control units offer a wide range of possibilities, from simplified running to the option of managing the most complex coupling operations, and can be adapted to suit every need. TYPES OF CONTROL UNIT

NEXYS

Adriatic Pacific Montana Atlantic (≤V220C2) Atlantic (≥V220 C2) Oceanic Exel

TELYS

KERYS

O O O O

X X X X O O O

X X X Standard

O Option

X Not available

Comparison of the 3 control units SPECIFICATIONS DISPLAY Frequency Phase to neutral voltages Phase to phase voltages Currents Active/reactive/apparent power Power factor Battery voltage: Battery current Start-up delay Fuel level Oil pressure Coolant temperature Oil temperature Total working hours counter Partial working hours counter Total active/reactive energy meter Genset speed Fault information (fault or alarm) Min/max alternator voltage Min/max alternator frequency Min/max battery voltage Overload and/or short circuit Active/reactive power return Oil pressure Coolant temperature Speed too high Speed too low Low fuel level Emergency stop fault Non-starting fault Charging alternator fault Differential relay activation fault General alarm General fault Sound alarm

NEXYS

X X O O

X

TELYS

KERYS

O

O O

O

O

X X O X X X X

SPECIFICATIONS OPERATION Power ON Manual genset starting Automatic genset starting Genset shut down Emergency stop Navigation in colour touch-screen menu Navigation in menu using wheel Navigation in menu using button Speed adjustment Voltage adjustment Dual frequency Delayed start programming Multilingual using pictograms Multilingual text CONNECTIVITY Ethernet port (website) RS485 (JBUS protocol) Engine CAN Bus (J1939) USB port (config and software downloading) COUPLING Under Load Shut down Droop distribution of active and reactive power Parallel line distribution of active and reactive power CAN Bus distribution of active/reactive power Power plant wattmeter control Temporary coupling of Out/Return grid Power plant coupling to grid (temporary, permanent, etc.) General Downloading of a customised configuration via USB port Standard O Option X Not available (1) Standard from 160 kVA

O(1) O

18

NEXYS

TELYS

X X

X

O O O X

X O O O

X X X X

X

X X O X

X

X X X X X X X X

KERYS

X O X X X X O O X X

power products control units

NEXYS

NEXYS: the essentials made simple The NEXYS, SDMO's new entry-level control unit, allows for operation in both manual and automatic mode. Modular in design, it offers high-quality basic functions, allowing easy and reliable operation of your generating set. The NEXYS electronic board is tropicalised to withstand extremely humid conditions. Operating lights Panel lighting

LCD display

Emergency stop button Position of options

ON/OFF key switch

Fuse

Scrolling display button / Generating set stop button / Generating set start button

MEASUREMENTS

Operating INDICATORS

LCD display examples

Alarms and faults Battery voltage:

Speed too high

AUT

AUT Non-Starting Fault

Frequency (Hz) Battery voltage (V) Time delay(1)(s)

AUT

Preheating

AUT

Working hours counter 1st line: Hours 2nd line: 10th of an hour Time delay(1)(s)

Time delay in progress

Coolant temperature

AUT

Generating set speed (rpm) Battery voltage (V) Time delay(1)(s)

operating lights

(1) Air preheating, start-up attempt, micro-disconnection, mains return

System power ON

Emergency stop

Generating set operation

Alarm

Fault

For more information on the NEXYS, please get in touch with your SDMO commercial contact

19

power products control units

product plus points

TELYS

TELYS, ergonomic and intuitive As SDMO's flagship product, the TELYS integrates new options. It is even more straightforward, with the emphasis on communication (USB connections, PC connections, control software and remote operation). The TELYS can be fitted in place of the NEXYS as aftermarket equipment.

ADAPTATION:

Power Products generating set control units are designed directly by SDMO and therefore their performance is always subject to ongoing improvement.

INNOVATION:

Alarms Emergency stop button

2 USB ports under a sealed cover

Generating set start button System power ON

Faults

Escape button

TELYS now integrates a coupling function as an option: - grid temporary coupling (1 generating set + grid) - coupling between generating sets.

ON/OFF key switch Zone 1

Fuse

Zone 2

Zone 4

Generating set stop button Menu access button

Zone 3

Scrolling and validation wheel

Display screen composed of 4 zones: ZONE 1: Operation mode (auto/manual/GS flow, etc.) ZONE 2: Function display with pictograms ZONE 3: Display of mechanical and electrical values and the associated measurements ZONE 4: Parameters menu and operation messages

Its design, inspired by the NEXYS, has reduced the number of buttons to offer you simplicity when operating your generating set. It also offers new functions: - Integrated maintenance monitoring (screen display of planned maintenance procedures)

- Screen with contrast which adjusts to all types of light

- Integrated diagnostic tool to guide the user when alarms or faults appear

- Tropicalisation of the electronic board to withstand conditions of extreme humidity

- Viewing and remote control functions with option to send an e-mail, text message or fax in the event of a warning or a fault (1)

- Compliance with numerous legal and regulatory requirements (EC)

(1) Option

For more information on the TELYS, please get in touch with your SDMO commercial contact

20

power products control units

KERYS

KERYS, coupling and adaptability The KERYS touch screen is a user-friendly, easy to grasp tool, offering a wide range of functions. It is fitted as standard to all generating sets designed for coupling applications, and can be fitted as an option, from 200 kVA, to the rest of our applications. So that all the requirements of high and low voltage power plants can be met, the KERYS touch screen can be built into the console, fitted directly onto the generating set or on a separate cabinet.

Display touch screen 7 inch LCD TFT display Detailed colour display Control keypad with display indicator lights Manual mode selection Stop mode selection Automatic mode selection Open/closed Genset circuit breaker Test activation/deactivation Open/closed Grid circuit breaker Indicator light test Horn off Clear faults

Configuration keypad For setting parameters, navigation and direct access to screens

Arrow keys with LED showing activity

Additional specifications Measurements Power factor in the different screens Active and reactive powers Synchronism (difference in phase, voltage

Synchronisation Automatic and manual Frequency, voltage and phase equalisation

and frequency)

Control Speed and voltage Switching frequency and voltage set values Adjusting frequency and voltage set values Adjusting active and reactive power set values Active and reactive power surge keyway Active and reactive power distribution Active and reactive power return setting Power factor setting Manual control of speed and voltage regulations

Harmonics in voltage and current Safety features Overload, short circuit Phase current direction Neutral current Reverse component Voltage reserve Thermal image Presence and absence of voltage Maximum active power Active and reactive power return Homo-polar current and homo-polar current direction Restricted earth and homo-polar voltage Vector jump, min Z and df/dt

Communication In local mode or remote mode Built-in web server: Via RS485 connection Via Ethernet (in local mode) and Internet (in remote mode)

Plus points integrated as standard Fault finding aid Assistance and maintenance (history, sending of e-mails...) Mechanical and electrical parameter archives and curves Addition of supplementary software without external tool Configurations A612: Generating set without grid A622: Generating set with normal/emergency switch and grid without coupling A633: Production plant without grid A641: Generating set with permanent coupling to grid without normal/emergency switch - Grid coupling + resale A642: Generating set with permanent coupling to grid without normal/emergency switch - Grid coupling + power level 0 kW on the grid A651: Generating set with temporary coupling to grid and normal/emergency switch A661: Generating set with permanent coupling to grid and normal/emergency switch

For more information on the KERYS, please get in touch with your SDMO commercial contact

21

POWER products from 6 kVA to 715 kVA Power modules

Up to 630A, the power modules are integrated into the consoles*. The extra-flexible cables between the console and the alternator are fitted in a corrugated insulating sleeve.

Power module specifications POWER OUTPUT

2 poles

Modular circuit breaker from 10A to 125A Fixed unit circuit breaker 160A to 630A

(2)

X

(1) As standard for some neutral connections (2) Only for single phase generating sets.

3 poles

4 poles

x (1) O

Standard O Option X Not available

AIPR Above 630A, power modules called AIPR are separated from the control/command. These control boxes are fitted on the generating set chassis and connected to the alternator. AIPR 1 With manual control on the front panel 3-pole open circuit breaker 4-pole open circuit breaker Motorised control option** With 3-pole circuit breaker, open type With 4-pole circuit breaker, open type Other specifications Voltage 208V-440V Power connection bus bars Protection index Dimensions height (mm) width (mm) depth (mm)

O O O

IP 23 1020 560 238

** The motorised control includes: a closing electromagnet, a shunt trip coil and an AC motor Standard O Option

22

* If the motorised control option is selected, the Power module is placed in AIPR

The control consoles

POWER products INS (Normal/emergency switch)

product plus points

VERSO From 35A to 160A, the VERSO is the SDMO changeover switch. Available in three phase and single phase versions, it integrates the power detection and allows automatic/manual start-up of the generating set in the event of a mains power cut.

IP54 control unit Ratings Type Nominal voltage/frequency Display and setting Voltage drop tolerated Protects against a change in the phase rotation direction Protection in "0" position Lightning arrester Confirmation of mains return EJP (for France only) Protection index Dimensions (l x w x h) in mm

Potentiometer 20% of the nominal voltage @230V

VERSO S Three phase 80A 100A 125A Three phase 127 / 230 V / 50-60Hz 230 / 400 V / 50-60Hz Potentiometer 20% of the nominal voltage @400V

X

O

X X

X X

Rapid automatic protection available for D versions O

IP54 305x410x150

IP31 385x385x193

IP54 400x600x200

63A

VERSO S Single phase 100A 125A 160A Single phase

35A

230V / 50-60Hz

63A

160A

35A

VERSO D 80A 100A 125A Three phase 127 / 230 V / 50-60Hz 230 / 400 V / 50-60Hz Via LCD display 30% of the nominal voltage @400V 63A

TSI From 200A to 3150A, the TSI is perfectly suited to industrial applications where the transfer of a main source to a replacement source is crucial for the running of your installations. It exists in three-pole and four-pole versions.

TSI Ratings Type

200A

Nominal voltage/frequency Configuration Display and setting Voltage drop tolerated Protects against a change in the phase rotation direction Lightning arrester EJP pack (for France only) Confirmation of mains return Protection index Inputs/outputs Dimensions (l x w x h) in mm

250A-400A-630A

800A-1000A-1600A Three phase 127 / 230 V / 50-60HZ 230 / 400 V / 50-60HZ Auto-configuration of voltage/frequency min/max and configurable thresholds By LCD - Supplied with manually-operated key - Can be padlocked in manual mode. 30% of the nominal voltage @400V

2000A-2500A-3150A

O O O O IP30 3 configurable report inputs/2 configurable report outputs - Modbus RTU available on RS232 (Non insulated) 800x600x400 800x600x400 1000x800x500 1800x1000x800 Standard

O Option

X Not available

23

160A

CENTRAL WEST SDMO CHOLET Tel. 02 41 75 96 70 Fax 02 41 75 96 71

PARIS/NORTHERN NORMANDY SDMO Gennevilliers Tel. 01 41 88 38 00 Fax 01 41 88 38 37

EAST

PPR-IN-DO-EN-31 - 50HZ 60HZ - English

SDMO Metz Tel. 03 87 37 88 50 Fax 03 87 37 88 59

SOUTH EAST

GERMANY SDMO GmbH Tel. +49(0)63 32 97 15 00 Fax +49(0) 63 32 97 15 11

BELGIUM SDMO NV/SA Tel. +32 36 46 04 15 Fax +32 36 46 06 25

SOUTH AFRICA SDMO JOHANNESBURG Tel. +27 (0)8 32 33 55 61 Fax +33 (0)1 72 27 61 51

ALGERIA SDMO ALGER Tel. +213 (0) 21 68 12 12 Fax +213 21 68 14 14

SPAIN

DUBAI

SDMO INDUSTRIES IBERICA Tel. +34 (9)35 86 34 00 Fax +34 (9) 35 80 31 36

SDMO MIDDLE EAST Tel. +971 4 458 70 20 Fax +971 4 458 69 85

UK

EGYPT

SDMO ENERGY Ltd TEL. +44(0) 1606 838 120 FAX +44(0) 1606 837 863

SDMO CAIRO TEL. + 202 24 19 58 66 FAX + 202 24 19 57 31

LATIN AMERICA & CARIBBEAN

SDMO Valence Tel. 04 75 81 31 00 Fax 04 75 81 31 10 SDMO Aix Tel. 04 42 52 51 60 Fax 04 42 52 51 61

SDMO GENERATING SETS Tel. +1 30 58 63 00 12 Fax +1 30 58 63 97 81

SOUTH WEST

SDMO MAQUIGERAL Tel. +55 (11)37 89 60 00

SDMO Toulouse Tel. 05 61 24 75 75 Fax 05 61 24 75 79

Offices

BRAZIL

SDMO Industries - 12 bis rue de la villeneuve CS 92 848 - 29 228 Brest Cedex 2 - France Tel. +33 (0)2 98 41 41 41 - Fax +33 (0)2 98 41 63 07 www.sdmo.com

RUSSIA SDMO MOSCOW Tel.+7 495 665 16 98 Fax +33 (0)1 72 27 55 48

TOGO SDMO WEST AFRICA TEL. + 228 92 43 79 33

SDMO is a registered trademark of SDMO Industries. Non-contractual document - In accordance with our product quality improvement policy, SDMO Industries reserves the right to modify, without prior notice, any specifications published in this catalogue. Photo credit: SDMO - Guillaume Team

WEST SDMO BREST Tel. 02 98 41 13 48 Fax 02 98 41 13 57

Subsidiaries

6886-04.13-L

French Offices