Hematotoxicity of magnetite nanoparticles coated

0 downloads 0 Views 1MB Size Report
Downloaded by Centro de Biologia Molecular Severo Ochoa (CBM) on 28/09/2015 16:22:43. View Article .... determined through manual measurement of more than 200 particles and data ...... detecção de dano no DNA e reparo em células.
Toxicology Research

View Article Online View Journal

Accepted Manuscript

This article can be cited before page numbers have been issued, to do this please use: A. Ruiz, L. Ali, P. Cáceres-Velez, R. Cornudella, M. Gutiérrez, J. A. Moreno, R. Piñol, F. Palacio, M. L. Fascineli, R. Bentes de Azevedo, M. P. Morales and A. Millán, Toxicol. Res., 2015, DOI: 10.1039/C4TX00241E.

This is an Accepted Manuscript, which has been through the Royal Society of Chemistry peer review process and has been accepted for publication. Accepted Manuscripts are published online shortly after acceptance, before technical editing, formatting and proof reading. Using this free service, authors can make their results available to the community, in citable form, before we publish the edited article. We will replace this Accepted Manuscript with the edited and formatted Advance Article as soon as it is available. You can find more information about Accepted Manuscripts in the Information for Authors. Please note that technical editing may introduce minor changes to the text and/or graphics, which may alter content. The journal’s standard Terms & Conditions and the Ethical guidelines still apply. In no event shall the Royal Society of Chemistry be held responsible for any errors or omissions in this Accepted Manuscript or any consequences arising from the use of any information it contains.

www.rsc.org/toxicology

Page 1 of 14

Toxicology Research View Article Online

DOI: 10.1039/C4TX00241E

RSCPublishing

ARTICLE Hematotoxicity of magnetite nanoparticles coated with polyethylene glycol: In vitro and in vivo study

Received Accepted DOI: 10.1039/x0xx00000x www.rsc.org/

A. Ruiza,b§, L. M. A. Alic§, P. R. Cáceres-Vélezd, R. Cornudellae, M. Gutiérreze, J. A. Morenoe, R. Piñolc, F. Palacioc, M. L. Fascinelid, R. B. de Azevedod, M. P. Moralesa* and A. Millánc* Hematotoxicity of magnetite nanoparticles coated with dimercaptosuccinic acid (DMSA) and polyethylene glycol (PEG) has been evaluated by determining their safety in vitro and in vivo in a rat model up to 30 days after administration of a single dose. The in vitro analysis consists on global plasma coagulation (PT, aPTT, Fibrinogen) and platelet aggregation tests while the hematotoxicity studies in vivo include a complete blood count and the possible genotoxic effects analysis in the bone marrow hematopoietic function. Prolonged aPTT values indicate higher anticoagulant effect for NP-DMSA compared with PEG-coated nanoparticles as a consequence of the higher surface charge of the former. The in vivo tests showed that these bioferrofluids do not cause genotoxic effects, affect erythropoiesis or increase the number of immature erythrocytes in the bone marrow at the analyzed dose. However, nanoparticles administration showed a significant effect on the leukocytes counts in animals treated with DMSA coated nanoparticles 24 h after injection. This response is not observed in animals treated with PEG modified nanoparticles which justifies the use of this polymer in biomasking strategies. Keywords: magnetic nanoparticles, toxicity, PEG coated nanoparticles, blood, hematological parameters

Interactions of nanoparticles with blood usually start with protein

Introduction

adsorption3, and subsequently derive in coagulation problems and Magnetic nanoparticles based on iron oxides are being used as contrast agents in magnetic resonance imaging (MRI).

Clinical

applications of these materials in drug delivery, hyperthermia and

other disturbances. Several studies have reported that environmental nanoparticles significantly increase the risk and worsen the prognosis of cardiovascular diseases due to the induction of

1

diagnosis are also being considered seriously . However, a first requisite for in vivo applications is blood compatibility2, otherwise these materials would be immediately discarded for intravenous administration.

thrombotic complications4. Protein adsorption is favored by surface charges, especially positive charges, and can be minimized with an appropriate coating. Carbohydrates and other biological polymers have been considered to be effective against protein adsorption, although polyethylene glycol is the preferred coating for these

This journal is © The Royal Society of Chemistry 2013

J. Name., 2013, 00, 1-3 | 1

Toxicology Research Accepted Manuscript

Published on 15 September 2015. Downloaded by Centro de Biologia Molecular Severo Ochoa (CBM) on 28/09/2015 16:22:43.

Toxicology Research

Toxicology Research

Page 2 of 14 View Article Online

Journal Name DOI: 10.1039/C4TX00241E

purposes5, 6. However there are only few studies investigating the

(Dimercaptosuccinic acid (DMSA) and Polyethylene glycol (PEG))

hematological effects of nanoparticles in vivo in spite of the fact that

could lead to blood coagulation disorders and affect hematological

the majority of nanoparticle formulations are intended for systemic

parameters in vitro and in vivo. These bioferrofluids have previously

administration in clinical applications.

In addition, there are no

been used in biodistribution and pharmacokinetics studies in

standard methodologies for the in vitro assessment of the blood

different animal models. PEG coated nanoparticles have shown a

compatibility of these nanoproducts.

good performance as MRI long circulating agents due to the effect of incorporation of PEG into the nanoparticle surface which is known

The in vitro biocompatibility studies should also include evidence of to provide stealth coating to camouflage them, and thus, temporarily hemolysis.

The unique physicochemical properties of the bypass recognition by macrophages9.

As with any device or

nanoparticles could cause hemolysis by acting on the membrane of pharmaceutical product, DMSA or PEG coated nanoparticles red blood cells. Several studies have revealed the effect of the intended for biomedical application must also be subjected to nanoparticles on the blood by measuring their hemolytic action in vitro7.

extensive blood biocompatibility testing before regulatory approval However, direct results interpretation of these studies is for administration to patients.

To our knowledge, the blood

complicated due to variability of the experimental conditions such as biocompatibility of these products has not been established till date. incubation time of blood with the nanoparticles, the wavelength at Previous hematological studies on iron oxide nanoparticles coated which the hemoglobin is quantified, the centrifugation forces, blood storage time and conditions and blood source (human or rabbit)8.

with poly(4-vinyl pyridine)-polyethylene glycol (PVP-PEG) brush copolymers indicated a non-specific anticoagulant effect of the

Platelets are very sensitive to contact with biological substances,

bioferrofluid10.

such as collagen, ADP and epinephrine, and non-biological ones, We have carried out an extensive in vitro biocompatibility study of including ristocetin, that are commonly used in the hematology our bioferrofluids with blood including coagulation studies, laboratory to detect functional defects of platelets. Foreign materials hemolysis and quantification of leukocytes, erythrocytes and and high shear stress can also induce platelet aggregation. When this platelets, to rule out immediate cytotoxicity of nanoparticles or occurs they tend to produce micro aggregates that are easily detected contact spontaneous platelet aggregation11-13.

Moreover, blood

by modern blood cell counters because they decrease the number of toxicity of these nanomaterials has been studied in terms of global platelets and alter the size distribution curve. Nanoparticles can tests (Prothrombin time (PT), activated partial thromboplastin time potentially damage the cell membrane and even the cytoplasm since (aPTT), Fibrinogen), thrombus-elastography, platelet aggregation they can penetrate inside cells. Blood cell counters not only quantify and degradation products of fibrinogen and fibrin.

Recently, a

blood cells but also can detect abnormalities in shape, size and detailed description of methods has been published, which focuses homogeneity. on the global plasma coagulation tests (PT, aPTT, Fibrinogen) and This study was designed specifically to investigate whether iron

platelet aggregation14. The doses used in this study are higher than

oxide magnetite nanoparticles with a narrow size distribution (Mean

the therapeutically relevant concentration but describe the range

size=7

where we observed an effect on hematological parameters. The

nm;

SD