info - Lyons Heating & Air

48 downloads 1339 Views 216KB Size Report
24 Jul 2010 ... The new FTQ/RZQ system is aimed at the residential market as an energy efficient alternative or replacement for a standard split system or gas furnace. ... Reduced installation time with integrated electronic expansion valve and printed ... Daikin reserves the right to modify product design, specification and ...
Sales ales Bulletin #SA005

Date:

July 24, 2010

To:

Daikin Sales, Service and Distribution

Subject:

FTQ_PAVJU / RZQ_PVJU9 - New Inverter Unitary Ducted System

Daikin AC is pleased to announce the launch of the Daikin FTQ_PAVJU / RZQ_PVJU9 Inverter Unitary Ducted System. The new FTQ/RZQ system is aimed at the residential market as an energy efficient alternative or replacement for a standard split system or gas furnace. This system offers wide application flexibility with optional horizontal right configuration and optional electric heat coupled with new control logic. Sales availability of the New Inverter Unitary Ducted System is end of July 2010.

Features               

Combines a traditional style split system air handling unit with Daikin’s energy efficient inverter compressor, fan and control technology High efficiency cooling with up to SEER 18.15 Energy Star Tier II rated and qualifies for $1,500 tax credit High efficiency heating with up to HSPF 8.92 Ability to provide heat in ambient conditions as low as 0F Unmatched heating capabilities with up to 100% capacity available at 14°F WB Increased application flexibility with long piping capability (165ft) and compact outdoor unit Outdoor unit sound levels as low as 48dB(A) as compared to traditional unitary condensers Reduced installation time with integrated electronic expansion valve and printed circuit boards Reduced piping costs with small piping diameters (3/8”x5/8”) Wide application range with dual voltage 208-230V/1/60Hz power supply Both upflow and horizontal right installation is permitted Increased application flexibility with optional electric resistance heat (see pages 6-7 for details) Improved user comfort with 2 selectable fan speeds (H and L) Fan “Auto” logic allowing the unit to be commissioned where the fan operation will cycle on and off with the load. Heating and Cooling Fan Auto mode can be configured separately Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 2 of 9



The ECM Fan Motor as standard contributes to an increase in energy efficiency, reduction in sound and increased External Static Pressure (up to 0.5” WG) Installation cost can be reduced with the ability to use the thermistor in the optional BRC1E71 remote controller as the primary temperature sensor (see controller section below) Each unit is provided with a gravity fed drain connection. Integration of a field supplied volt free float switch is possible A field supplied secondary drain pan is recommended for installations where water damage from unit condensation may occur

  

Applications    

Perfect for new construction or replacement for a standard ducted split system Energy efficient option to a traditional gas furnace eliminating the need for fossil fuels Multiple units can be used to provide zoning in larger residences Long piping capabilities and low sound levels make it ideal for multi-family residence applications

Specifications Summary FTQ / RZQ Specifications Model Indoor Unit Outdoor Unit Power Supply Rated Cooling Capacity EER SEER Rated Heating Capacity HSPF Refrigerant Refrigerant Control Airflow Rate H/L Indoor Unit Weight Indoor Unit Height Indoor Unit Width Indoor Unit Depth Outdoor Unit Weight Outdoor Unit Height Outdoor Unit Width Outdoor Unit Depth Oudoor Unit Sound Pressure H/L External Static Pressure Range Unit Condensate Connection Gas Pipe Connections Liquid

1.5-Ton

V/ph/Hz Btu/h

Btu/h

cfm lbs. in. in. in. lbs. in. in. in. dB(A) in. W.G. in. O.D. in. in.

External Finish Protection Devices MOP

A

2-Ton

18 24 FXTQ18PAVJU FXTQ24PAVJU RZQ18PVJU9 RZQ24PVJU9 208-230/1/60 18,000 24,000 13.9 12.5 18.15 18.0 27,000 20,000 8.92 8.89 R-410A R-410A Electronic Expansion Valve 600/420 800/560 169 169 53-1/4 53-1/4 22 22 24 24 150 150 30-5/16 30-5/16 35-7/16 35-7/16 12-5/8 12-5/8 48/49 49/51 up to 0.5 up to 0.5 3/4 (fpt) 3/4 (fpt) 5/8 (Braze) 5/8 (Braze) 3/8 (Braze) 3/8 (Braze) Fully insulated, painted steel cabinet with gray finish Fuse/Breaker Fan Motor Thermal Protector 15 15 Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 3 of 9

Operating Ranges  

Cooling Operating Range: 23FDB - 115FDB (0FDB - 115FDB with optional wind baffle) Heating Operating Range: 0FDB - 77FDB

Capacity Information Cooling Capacity FTQ / RZQ 18 Cooling Capacity Outdoor Air Temp. °FDB Indoor Air Temp. °FDB 68.0 72.0 77.0 80.0 86.0 90.0

°FWB 57.0 61.0 64.0 67.0 72.0 75.0

TC kBTUH 11.68 14.21 16.10 18.00 20.79 21.14

68 SHC MBh 11.1 12.5 13.4 14.0 14.9 14.2

PI kW 0.50 0.48 0.55 0.64 0.79 0.80

TC kBTUH 11.68 14.21 16.10 18.00 20.06 20.41

77 SHC MBh 11.1 12.5 13.4 14.0 14.7 13.9

PI kW 0.54 0.66 0.77 0.88 1.00 1.01

TC kBTUH 11.68 14.21 16.10 18.00 19.32 19.68

86 SHC MBh 11.1 12.5 13.4 14.0 14.0 13.4

PI kW 0.61 0.76 0.88 1.02 1.10 1.10

TC kBTUH 11.68 14.21 16.10 17.27 17.86 18.21

104 SHC MBh 11.1 12.5 13.4 14.0 13.4 12.9

PI kW 0.78 0.99 1.17 1.27 1.29 1.29

TC kBTUH 15.57 18.94 21.47 24.00 25.76 26.24

86 SHC MBh 13.6 16.0 17.6 18.4 17.8 16.9

PI kW 0.88 1.11 1.30 1.51 1.63 1.64

TC kBTUH 15.57 18.94 21.47 23.02 23.81 24.29

104 SHC MBh 13.6 16.0 17.6 17.7 16.7 15.7

PI kW 1.15 1.47 1.74 1.90 1.92 1.93

Cooling Capacity Outdoor Air Temp. °FDB Indoor Air Temp. °FDB 68.0 72.0 77.0 80.0 86.0 90.0

°FWB 57.0 61.0 64.0 67.0 72.0 75.0

TC kBTUH 11.68 14.21 16.10 18.00 19.00 19.35

90 SHC MBh 11.1 12.5 13.4 14.0 14.0 13.5

PI kW 0.64 0.80 0.94 1.09 1.14 1.14

TC kBTUH 11.68 14.21 16.10 18.00 18.59 18.95

95 SHC MBh 11.1 12.5 13.4 14.0 13.9 13.2

PI kW 0.69 0.87 1.01 1.18 1.19 1.20

FTQ / RZQ 24 Cooling Capacity Outdoor Air Temp. °FDB Indoor Air Temp. °FDB 68.0 72.0 77.0 80.0 86.0 90.0

°FWB 57.0 61.0 64.0 67.0 72.0 75.0

TC kBTUH 15.57 18.94 21.47 24.00 27.72 28.19

68 SHC MBh 13.6 16.0 17.6 18.4 18.9 18.2

PI kW 0.71 0.85 0.97 1.11 1.34 1.35

TC kBTUH 15.57 18.94 21.47 24.00 26.74 27.21

77 SHC MBh 13.6 16.0 17.6 18.4 18.2 17.6

PI kW 0.77 0.96 1.12 1.30 1.48 1.49

FTQ / RZQ 24 Outdoor Air Temp. °FDB Indoor Air Temp. °FDB 68.0 72.0 77.0 80.0 86.0 90.0

°FWB 57.0 61.0 64.0 67.0 72.0 75.0

TC kBTUH 15.57 18.94 21.47 24.00 25.33 25.80

90 SHC MBh 13.6 16.0 17.6 18.4 17.4 16.7

PI kW 0.93 1.18 1.39 1.61 1.69 1.70

TC kBTUH 15.57 18.94 21.47 24.00 24.79 25.26

95 SHC MBh 13.6 16.0 17.6 18.4 17.3 16.4

PI kW 1.00 1.28 1.50 1.75 1.77 1.79

Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 4 of 9

Heating Capacity FTQ / RZQ 18 Heating Capacity Outdoor Air Temp. °FWB Indoor Air Temp.

14 TC MBh 23.33 22.22 20.74 20.00 19.26 18.15

°FDB 61.0 64.0 68.0 70.0 72.0 75.0

23 PI kW 2.65 2.49 2.28 2.18 2.08 1.94

TC MBh 23.33 22.22 20.74 20.00 19.26 18.15

32 PI kW 2.33 2.20 2.02 1.94 1.85 1.73

TC MBh 23.33 22.22 20.74 20.00 19.26 18.15

43 PI kW 1.98 1.87 1.72 1.65 1.59 1.49

TC MBh 23.33 22.22 20.74 20.00 19.26 18.15

50 PI kW 1.74 1.65 1.52 1.46 1.41 1.32

TC MBh 23.33 22.22 20.74 20.00 19.26 18.15

PI kW 2.40 2.27 2.10 2.01 1.93 1.81

TC MBh 31.50 30.00 28.00 27.00 26.00 24.50

PI kW 1.62 1.53 1.42 1.37 1.31 1.24

FTQ / RZQ 24 Heating Capacity Outdoor Air Temp. °FWB

°FDB 61.0 64.0 68.0 70.0 72.0 75.0

14 TC MBh 24.18 24.14 24.09 24.06 24.03 23.99

23 PI kW 2.38 2.43 2.49 2.52 2.55 2.60

TC MBh 26.67 26.63 26.57 26.55 26.00 24.50

32 PI kW 2.48 2.52 2.58 2.61 2.56 2.39

TC MBh 30.49 30.00 28.00 27.00 26.00 24.50

43 PI kW 2.60 2.58 2.38 2.28 2.18 2.04

TC MBh 31.50 30.00 28.00 27.00 26.00 24.50

50 PI kW 2.23 2.11 1.95 1.88 1.80 1.69

Superior Heating Capacity at Low Ambient Conditions  

Unlike traditional residential unitary heat pump systems, which require back up heat below 45°F ambient, the Daikin Inverter Unitary Ducted system can provide heating as low as 0°F Superior heating performance and user comfort can be realized with up to 100% capacity available at 14°FWB

FTQ18PAVJU / RZQ18PVJU9 70F Indoor Temperature Heating Capacity 25.00

Heating Capacity MBh

Indoor Air Temp.

20.00

15.00

100% Capacity at 14°FWB

10.00

5.00

0.00 14

23

32

43

50

Outdoor Air Temperature (FWB)

Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 5 of 9

FTQ24PAVJU / RZQ24PVJU9 70F Indoor Temperature Heating Capacity 30.00

Heating Capacity MBh

25.00 20.00

89% Capacity at 14°FWB

15.00 10.00 5.00 0.00 14

23

32

43

50

Outdoor Air Temperature (FWB)

Controller Configurations

Note: System price does not include a remote controller. Please refer to the additional accessories table on page 8 for controller options. Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 6 of 9

Electric Heater Information      

Wide line-up of field installed electric heater options from 3kW to 10kW Integrated heater control relays and logic to minimize cost Electric booster heater operation in combination with heat pump operation is now possible 2-stage heating control available on larger models Reduced operational deadband for increased user comfort During electric heater operation, the indoor unit fan is fixed in H (High) speed regardless of the controller setting

Model Name

3kW

Electric Heater Capacity 5kW 6kW 8kW

 

FTQ18PAVJU FTQ24PAVJU

 

 

10kW

X 

X 

X Not allowed

 Electric heater operation with heat pump is allowed  Only electric heater operation is allowed



The operating condition of the electric heater is programmable via a field setting. Please refer to the FTQ_PAVJU Installation Manual for additional field setting information

Method 1 – Booster Heater  For models that allow electric booster heater operation in combination with heat pump operation (see table above), the thermo-on setpoint for the electric heater is programmable. The electric heat can be energized between 7.2F and 2.7F below the remote controller heating setpoint  The thermo-off setpoint for the electric heater is also programmable. The electric heat can be de-energized between 3.6F below and 0.9F above the remote controller heating setpoint  The indoor unit heat pump will continue to operate as normal  In the example below, the electric heater energizes at 2.7F below the heating setpoint and de-energizes at 0.9F above the heating setpoint

Heat Pump

Booster Heater

74F thermoOFF

Room Temp

73F Heating Set Point Point

72F

OFF

71F thermoON

70F 69F 68F

ON

67F 66F

Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 7 of 9

Method 2 – Electric Heater (Lockout)  For unit models that allow only electric heat operation (see page 6 for details), the thermo-on setpoint for the electric heater is set to be energized 1F below the remote controller heating setpoint  The thermo-off setpoint for the electric heater is set to be de-energized at 1F above the remote controller heating setpoint  A BRP2A81 – ABC terminal kit and third party ambient thermostat may be required to configure heat pump lockout operation. Please refer to Sales Bulletin VRV038 and the VRV Systems Basic Operation Guide for additional information on heat pump lockout with the BRP2A81-ABC terminal kit  In the following example, the electric heater energizes at 1F below the heating setpoint and de-energizes at 1F above the heating setpoint

Electric Heat (Lockout) 74F thermoOFF

Room Temp

73F Heating Set Point

72F 71F thermoON

70F 69F 68F 67F 66F

Heat Pump Lockout Mode Settings

Note: The FTQ_PAVJU fan is fixed in H speed during heating regardless of the controller setting See VRV Basic Operation Guide for further details on Heat Pump Lockout Mode Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 8 of 9

Additional Accessories FTQ / RZQ Accessories Model Indoor Unit Outdoor Unit Navigation Remote Controller Simplified Wired Remote Controller * Wireless Remote Controller Remote Sensor kit Wiring Adaptor PCB

18 FTQ18PAVJU RZQ18PVJU9 BRC1E71 BRC2A71 BRC4C82 KRCS01-4B 1

KRP1C75

2

KRP4A74

KRP1C75

(interface with aux/primary heater, humidifier, OA damper/fan)

Group Control Adaptor PCB

KRP4A74

(connects to external BMS)

24 FTQ24PAVJU RZQ24PVJU9 BRC1E71 BRC2A71 BRC4C82 KRCS01-4B

2

1

2 2

External Control Adapter for Outdoor Unit

DTA104A53

Fixing Box Air Filter Insulation Kit (vertical) Insulation Kit (horizontal)

KRP1B101 FIL 48-61 DPI 48-61/20 DPIH 48-61

KRP1B101 FIL 48-61 DPI 48-61/20 DPIH 48-61

HKR-03, HKR-05C, HKR-06, HKR-08C, HKR-10C

HKR-03, HKR-05C, HKR-06, HKR-08C, HKR-10C

DTA104A53

3

Electric Heater Kit

3

1 Need 24VAC power supply 2 Need 16VDC power supply 3 Fixing box installed beside the unit * Optional face plates available to provide a more intuitive user interface and disable specific functions

List Price July 2010

FTQ/RZQ

Model Name

List Price (in US$)

FXTQ18PAVJU / RZQ18PVJU9

$6,444

FXTQ24PAVJU / RZQ24PVJU9

$6,667

Note: System price does not include a remote controller or indoor unit filter. Please refer to the additional accessories table above for controller and filter options.

Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)

Page 9 of 9

Product and Documentation Availability

June TRL Pricing Sales Presentation Submittal Data Sheets Engineering Data Book Sales Promotion Leaflet (FTQ/RZQ only) - Marketing FTQ/RZQ Sales Availability

FTQ / RZQ 2010 July August ♦ ♦ ♦ ♦

Sept

♦ ♦

Daikin AC (Americas), Inc. 1645 Wallace Drive, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com

Published by Daikin AC Product & Engineering (Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specification and information in this bulletin without notice and without incurring any obligation.)