Injectorstoves ENG 2013.indd

5 downloads 225 Views 250KB Size Report
1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of ...
CENTUS PRODUCT INFORMATION: Thermal energy: Energy efficiency: CO%: Nominal heat output: Heat storage capacity:

35-40 kWh 84 % 0,08 % 2,9 kW / 2,0 h

100%

CENTUS 1 (white)

CENTUS 2 (white)

CENTUS 3 (white)

LAYOUT DRAWINGS AND CHANGE OPTIONS:

2,5 h

50%

9,6 h

25%

15,3 h

PRODUCT NUMBERS Product

Product number

Weight kg

Height mm

CENTUS 1

703221-1

555

1650

CENTUS 2

703221-2

555

1650

CENTUS 3

703221-3

555

1650

Standard colours: White, RAL 9010 Pure white, gloss 78 % Black, RAL 9005 Jet black, gloss 25 %

NunnaUuni special colours (by order): CENTUS 1

CENTUS 2

CENTUS 3

Blueberry Vanilla Mocca Lime Actual colours may vary from those printed

ACCESSORIES: - Floor protector (in front of the stove) - Rear heat shield Rear heat shield to reduce the safety distance

NunnaUuni Oy reserves the right to make alterations 06/13

PRODUCT INFORMATION FIREWOOD

Centus

FLUE CALCULATION VALUES (1

MAX. FLUE TEMPERATURE IN SECURITY TEST

Length [cm]

Max amount of wood [kg]

Length baking oven [cm]

Flue gas temperature [°C]

Min. flue draught [Pa]

Mass flow [g/s]

Burning heat output [kW]

Flue connection [A/B] Ø

Burning air approx. m³/h

Temperature °C

25

10

-

215

11

15,1

15,8

150

40

320

FLUE CONNECTION TABLE RECOMMENDED FLUE [mm] approx. 150x150

approx. 150x200

approx. 150x300

round Ø

Centus (2

-

-

-

150

Centus (3

x

x

-

150-180

SAFETY DISTANCES TO COMBUSTIBLE MATERIALS According to the EN 15250 Behind

On the sides

To the front

Centus

150

150

1100

Centus with heat shield

50

150

1100

1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of the fireplace. 3) The fireplace is connected to the flue using a connection pipe. NOTES! The flue heat category required by the fireplace is T400. The recommended minimum flue height is 3,5 m. In countries where the flue calculation is required, should the calculation be done according to the instructions and regulations of the flue calculation. A flue damper is not necessary for the flue. If a flue damper is installed, it must be equipped with an opening of at least 20 cm². The flue damper must not be closed before the embers have burned out!

NunnaUuni Oy reserves the right to make alterations 06/13

GENIUS PRODUCT INFORMATION: Thermal energy: Energy efficiency: CO%: Nominal heat output: Heat storage capacity:

35-40 kWh 84 % 0,08 % 2,9 kW / 2,0 h

100%

GENIUS

LAYOUT DRAWINGS AND CHANGE OPTIONS:

2,5 h

50%

9,6 h

25%

15,3 h

PRODUCT NUMBERS: Product

Product number

Weight kg

Height mm

GENIUS

703241-1

560

1904

Standard colours: White, RAL 9010 Pure white, gloss 78 % Black, RAL 9005 Jet black, gloss 25 %

NunnaUuni special colours (by order): GENIUS

Blueberry Vanilla Mocca Lime Actual colours may vary from those printed

ACCESSORIES: - Floor protector (in front of the stove) - Rear heat shield

Rear heat shield to reduce the safety distance

NunnaUuni Oy reserves the right to make alterations 06/13

PRODUCT INFORMATION FIREWOOD

Genius

FLUE CALCULATION VALUES (1

MAX. FLUE TEMPERATURE IN SECURITY TEST

Length [cm]

Max amount of wood [kg]

Length baking oven [cm]

Flue gas temperature [°C]

Min. flue draught [Pa]

Mass flow [g/s]

Burning heat output [kW]

Flue connection [A/B] Ø

Burning air approx. m³/h

Temperature °C

25

10

-

215

11

15,1

15,8

150

40

320

FLUE CONNECTION TABLE RECOMMENDED FLUE [mm] approx. 150x150

approx. 150x200

approx. 150x300

round Ø

Genius (2

-

-

-

150

Genius (3

x

x

-

150-180

SAFETY DISTANCES TO COMBUSTIBLE MATERIALS According to the EN 15250 Behind

On the sides

To the front

Genius

150

150

1100

Genius with heat shield

50

150

1100

1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of the fireplace. 3) The fireplace is connected to the flue using a connection pipe. NOTES! The flue heat category required by the fireplace is T400. The recommended minimum flue height is 3,5 m. In countries where the flue calculation is required, should the calculation be done according to the instructions and regulations of the flue calculation. A flue damper is not necessary for the flue. If a flue damper is installed, it must be equipped with an opening of at least 20 cm². The flue damper must not be closed before the embers have burned out!

NunnaUuni Oy reserves the right to make alterations 06/13

FIDUS PRODUCT INFORMATION: Thermal energy: Energy efficiency: CO%: Nominal heat output: Heat storage capacity:

FIDUS 1

FIDUS 2

LAYOUT DRAWINGS AND CHANGE OPTIONS:

35-41 kWh 88 % 0,09 % 2,2 kW / 4,1 h

100%

2,4 h

50%

11,4 h

25%

21,6 h

PRODUCT NUMBERS: Product

Product number

Weight kg

Height mm

FIDUS 1

703211-1

875

1825

FIDUS 2

703211-2

875

1825

ACCESSORIES: Product

FIDUS

Product number

Weight kg

FLOOR PROTECTOR

900348

6

BOTTOM PLINTH

200622

107

BOTTOM PLINTH ADDITIONAL STONES (+384mm)

200624

56

PARTS FOR BACK CONNECTION

900392

5

FIDUS with additional stones for bottom plinth Please notify: Bottom plinth is an accesory. Bottom plinth stones are polished only on 2 visible sides. Additional stones for bottom plinth are polished only from one visible side.

900392

NunnaUuni Oy reserves the right to make alterations 06/13

PRODUCT INFORMATION FIREWOOD

Fidus

FLUE CALCULATION VALUES (1

MAX. FLUE TEMPERATURE IN SECURITY TEST

Length [cm]

Max amount of wood [kg]

Length baking oven [cm]

Flue gas temperature [°C]

Min. flue draught [Pa]

Mass flow [g/s]

Burning heat output [kW]

Flue connection [A/B] Ø

Burning air approx. m³/h

Temperature °C

25

10

-

187

12

15,1

15,8

150

40

320

FLUE CONNECTION TABLE RECOMMENDED FLUE [mm]

CONNECTIONPART

approx. 150x150

approx. 150x200

approx. 150x300

round Ø

inner Ø

outer Ø

Fidus (2

-

-

-

150

160

-

Fidus (3

x

x

-

150-180

-

160

SECURITY DISTANCES TO COMBUSTIBLE MATERIALS According to the EN 15250

Fidus

Behind

On the sides

To the front

100

150

1100

1) Flue calculation values apply in countries where flue calculation in accordance with DIN 18160 or DIN EN 13384 is required. 2) The flue is installed on top of the fireplace. 3) The fireplace is connected to the flue using a connection pipe. NOTES! The flue heat category required by the fireplace is T400. The recommended minimum flue height is 3,5 m. In countries where the flue calculation is required, should the calculation be done according to the instructions and regulations of the flue calculation. A flue damper is not necessary for the flue. If a flue damper is installed, it must be equipped with an opening of at least 20 cm². The flue damper must not be closed before the embers have burned out!

NunnaUuni Oy reserves the right to make alterations 06/13