M9096 Mini Gas Train

20 downloads 2040 Views 121KB Size Report
Temperature Controller (110V) Requires external pumping & flow metering system such as Westech’s M9096 Mini Stack Train Console Impinger set includes:
M9096 Mini Gas Train

Mini Gas Sampling Train for Low Flow Constant rate Vapour phase Gas with options for Heated Filter Box & Filter (as shown). Can also be used for Side Stream Sampling. Comprises of: 1M-Heated Glass Lined Probe (110V) Support Tube Midget Impinger Set with Ice bath Umbilicals (un-heated) Temperature Controller (110V) Requires external pumping & flow metering system such as Westech’s M9096 Mini Stack Train Console Impinger set includes: 5 Plain Tube & 1 Jetted 40cl midget Impingers with U-Tubes, Clamps, PTFE Fittings & tubing with Foam Insert and Ice Packs. USA EPA Methods Method 4 Determination of moisture Method 6 Determination of SO2 Method 6a Determination of SO2, C0O2 and moisture

Gas Sampling Nozzle, replaceable Liner

O-ring Jointed Midget Glassware

European and International Standards EN1911 Determination of HCl (vapor only) ISO 7934 Determination of S02 (thorin method) ISO 11 Determination of SO2 (ion chrom) (not published yet) Can be used for other gases with rearrangement

Heated Probe Controller, Optional Two Channel shown

PTFE Ball Joints for Compliant Connection

Other Options: Longer probes, up to 2.0M Optional Probe Liner Materials: SS, Titanium, Quartz Glass, and PTFE. Accessory Glassware, fittings, tubing, Manifolds for Side Stream Sampling. Servicing, Calibration, Training & Consultancy. 220V Westech Instrument Services Ltd, Unit 10 Rectory Farm Business Park, Upper Stondon, Bedfordshire, SG16 6LJ. UK Tel: +44 (0) 1462 816966. Fax: +44 (0) 1462 817050.