Specify packaging, product, and option code. • For -R option, drop mA or A from product code. (i.e. GMC-2-R). • Ratings above 6.3A have a 0.8mm diameter lead.
5mm x 20mm Fuses GMC Series Medium Time Delay, Glass Tube Description • Medium time delay, low breaking capacity • Optional axial leads available • 5mm x 20mm physical size • Glass tube, nickel-plated brass endcap construction • Designed to UL/CSA 248-14

RoHS 2002/95/EC

ELECTRICAL CHARACTERISTICS Opening Time Rated Current % of Amp Rating None 100% 63mA - 10A 135% 60 minutes maximum 200% 2 minutes maximum

Agency Information • UL Listed, Guide JDYX, File E19180, 63mA-6.3A • UL Recognized Card: (7A-10A) Guide JDYX2, File E19180 • CSA Certified, Class 1422-01, File E65063, 63mA-6.3A • MITI Approval, 1A-10A • CCC Approval, 500mA-6.3A Ordering • Specify packaging, product, and option code • For -R option, drop mA or A from product code (i.e. GMC-2-R)

Dimensions

⁄(inches)

mm

38.10mm 0m (± ±.3 38) 5.54mm (±.20)



21.10mm 0m 1 (±.81)

±0.5)

5.2mm (+0.1/-0.2)

38.10mm 0mm (±.38) 0.65mm (REF)

• Ratings above 6.3A have a 0.8mm diameter lead • With TR2 packaging code, lead wire length is 19.05mm

SPECIFICATIONS Product Code GMC-63mA GMC-80mA GMC-100mA GMC-125mA GMC-150mA GMC-160mA GMC-200mA GMC-250mA GMC-300mA GMC-315mA GMC-400mA GMC-500mA GMC-600mA GMC-630mA GMC-700mA GMC-750mA GMC-800mA GMC-1A GMC-1.25A GMC-1.5A GMC-1.6A GMC-2A GMC-2.5A GMC-3A GMC-3.15A GMC-3.5A GMC-4A GMC-5A GMC-6A GMC-6.3A GMC-7A GMC-8A GMC-10A * ** † ‡

Voltage Rating AC 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 250V 125V 125V 125V 125V 125V 125V 125V 125V

AC Interrupting Rating* 250V 125V 35A 10,000A 35A 10,000A 10,000A 35A 35A 10,000A 35A 10,000A 35A 10,000A 35A 10,000A 10,000A 35A 35A 10,000A 35A 10,000A 35A 10,000A 35A 10,000A 35A 10,000A 35A 10,000A 35A 10,000A 10,000A 35A 35A 10,000A 10,000A 35A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 100A 10,000A 10,000A 100A 10,000A 10,000A 10,000A 10,000A 10,000A 200A 200A 200A

Typical DC Cold Resistance (ohms)** 10.350 4.775 3.400 2.555 2.295 1.395 0.965 0.838 0.685 0.615 0.335 0.282 0.246 0.213 0.213 0.180 0.156 0.098 0.076 0.067 0.043 0.035 0.026 0.025 0.022 0.019 0.014 0.013 0.012 0.012 0.009 0.007

Typical Pre-Arc I2t AC† 0.0027 0.0050 0.0094 0.014 0.022 0.022 0.032 0.046 0.081 0.081 0.18 0.41 0.60 0.66 0.85 0.85 0.85 1.8 3.4 5.4 5.8 8.9 13 19 23 25 36 58 88 110 150 200 300

Maximum Voltage Drop (mV)‡ 1400 1400 1200 1000 800 730 650 490 580 480 510 370 360 360 340 320 290 250 200 190 160 130 130 130 130 130 120 120 120 120 120 110 110

Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC. DC Cold Resistance (Measured at