Radiation Exposure of Computed Tomography and Direct ... - JACC

2 downloads 1862 Views 75KB Size Report
MSCT multislice computed tomography. TLD thermo luminescent dosimeter. 1847. JACC Vol. 47, No ... Wikipedia, The Free Encyclopeida. Available at: http://en.
Journal of the American College of Cardiology © 2006 by the American College of Cardiology Foundation Published by Elsevier Inc.

Vol. 47, No. 9, 2006 ISSN 0735-1097/06/$32.00 doi:10.1016/j.jacc.2005.10.075

Cardiac Imaging: Viewpoint

Radiation Exposure of Computed Tomography and Direct Intracoronary Angiography Risk Has its Reward Pat Zanzonico, PHD, Lawrence N. Rothenberg, PHD, H. William Strauss, MD New York, New York A hallmark of noninvasive testing has been the identification of patients with coronary artery disease. Now, with multislice computed tomography (MSCT), information about coronary anatomy can be obtained without the need for catheterization. A major concern with the application of MSCT coronary angiography is the radiation exposure to the patient. Both MSCT and selective coronary angiography share the risks of procedure-related complications, such as allergic contrast reactions, and stochastic risks (i.e., cancer induction) of low-level radiation. There is a substantially higher radiation dose for MSCT angiography (effective dose [ED] 14 mSv) than for CCA (ED 6 mSv). These exposures yield lifetimes risks of 0.07% and 0.02%, respectively, of inducing a fatal cancer in the general (i.e., age- and genderaveraged) population. However, CCA poses additional serious risks associated with cardiac catheterization, yielding a non-radiogenic risk of mortality— excluding contrast reactions— of 0.11%. Combining the radiogenic and non-radiogenic risks (0.02% and 0.11%, respectively) yields a 0.13% overall risk of mortality from CCA—nearly two-fold higher than that for MSCT angiography (0.07%). If one were to use the lower, more age-appropriate risk factors for the older patient population in question, the radiogenic risks of both CCA and MSCT would be reduced by about one-half, further widening the overall safety ratio of MSCT relative to CCA. When weighing the relative risks of alternative medical procedures, therefore, it is imperative that one consider the overall risk of the respective procedures. (J Am Coll Cardiol 2006;47:1846 –9) © 2006 by the American College of Cardiology Foundation “Risk is the potential harm that may arise from some present process or from some future event. It is often mapped to the probability of some event which is seen as undesirable. Usually the probability of that event and some assessment of its expected harm must be combined into a believable scenario (an outcome) which combines the set of risk, regret and reward probabilities into an expected value for that outcome.” —Wikipedia (1)

There are specific elements to an assessment of the value and risk of a procedure. The overall risk is a weighted summation of the risk contribution of each component of the procedure. In the case of contrast X-ray procedures, risk assessment is particularly complex because certain negative outcomes are apparent immediately (such as an extravasation at the contrast injection site, myocardial infarction or stroke during the procedure, decline in renal function, or allergic contrast reaction) whereas others are manifest only years later (such as the statistical risk of cancer induction). When comparing the risk of selective coronary angiography to that of multidetector computed tomography (CT) coronary angiography, there are risks common to both procedures, such as an allergic contrast reaction and radiaFrom the Departments of Medical Physics and Radiology (Nuclear Medicine Section), Memorial Sloan Kettering Cancer Center, New York, New York. Manuscript received September 12, 2005; revised manuscript received October 6, 2005, accepted October 25, 2005.

tion as well as risks unique to each. Typically, 100 to 130 ml of nonionic contrast media containing 300 to 350 mg of iodine per milliliter are injected for CT angiography or a combination of selective coronary intrarterial injections and possibly a ventriculogram for cardiac catheterization studies. Nonionic contrast media causes severe allergic reactions1 in 0.2% to 0.7% of patients (2–5). Additionally, CT coronary angiography poses a risk of extravasation2, which occurs in 0.3% to 0.6% of patients when a power injector is used in a peripheral vascular line. In addition to the 0.37% incidence of contrast reactions, cardiac catheterization has a major complication rate of 1.7%, including mortality in 0.11%, myocardial infarction in 0.05%, neurologic complications in 0.07%, and hemodynamic complications in 0.26% of cases (6,7). Compared with these readily apparent adverse events with the use of either CT or catheterization, the potential low-dose radiation risk is extremely difficult to evaluate. Risk must be considered in the context of the procedure. Cardiac catheterization has evolved from a diagnostic examination to a procedure often performed with intention to 1 Reactions are divided into mild, moderate, and severe. Mild reactions usually are self-limiting, often do not require treatment, or may be managed with the use of antiemetics and antihistamines. Significant urticaria may require steroids. Moderateto-severe bronchospasm, laryngospasm, or hypotension requires treatment with oxygen and epinephrine. Anaphylactoid reactions, seizures, or cardiovascular collapse requires a resuscitation team for evaluation and treatment (2). 2 Average of 18 ml. The incidence of extravasation is similar with injection rates of 1 to 2 ml/s and 3 to 4 ml/s.

JACC Vol. 47, No. 9, 2006 May 2, 2006:1846–9

Abbreviations and Acronyms CCA ⫽ conventional coronary angiography CT ⫽ computed tomography CTDI ⫽ computed tomography dose index DAP ⫽ dose-area product ED ⫽ effective dose MSAD ⫽ multiple-scan average dose MSCT ⫽ multislice computed tomography TLD ⫽ thermo luminescent dosimeter

treat. In 2002, an estimated 1,463,000 inpatient cardiac catheterization procedures were performed (8), leading to approximately 1,204,000 angioplasty procedures3. Lessinvasive procedures have become a gatekeeper, helping to select patients for catheterization in anticipation of treatment. In patients with chronic stable angina, for example, where the diagnosis of coronary disease is established, exercise EKGs were performed in 689,851 patients, whereas stress echocardiography was performed in 303,047 and stress myocardial perfusion imaging in 1,158,389 (9). The value of the noninvasive procedures is improved with the addition of information about coronary artery calcification (10) and is likely to be further enhanced with the addition of information about coronary anatomy. Contrast-enhanced, gated, multislice computed tomography (MSCT) coronary angiography offers an opportunity to visualize the coronary arteries in patients with chest pain. However, the patient radiation exposure associated with MSCT is higher than that of conventional diagnostic coronary angiography (CCA). The report by Coles et al. (11) in this issue of the Journal, which compares the radiation exposure from MSCT to that of diagnostic selective coronary angiography in the same patients, provides additional objective data about this important and timely issue. To put the risk of radiation in perspective, in 2002 malignant neoplasms caused the death of 557,271 people (of a total of 2,443,387 deaths) (12) in the U.S. It is unclear how many of these malignant neoplasms were related to radiation exposure. High doses of radiation are clearly linked to immediate and delayed effects (13), whereas the effects of long-term exposure to very low levels of radiation, as used in diagnostic procedures, remain highly controversial. For example, no additional risk of cancer was found in populations exposed to higher levels of background radiation (14,15) or among individuals (such as airline pilots) receiving relatively high occupational exposures (16,17). Despite such data, various advisory bodies used the conservative assumption that no level of radiation is without excess risk, that is, the zero threshold hypothesis. To estimate the practically immeasurable risk from low-level radiation, various mathematical models are required to extrapolate dose3 Angioplasty procedures consist of 657,000 percutaneous transluminal coronary angioplasties and 537,000 stent placements. A total of 640,000 patients had these angioplasty procedures.

Zanzonico et al. Risk Has its Reward

1847

risk data from highly exposed populations. Currently, a linear relationship between dose and risk is used in the risk model for low-level exposures. The National Council on Radiation Protection and Measurements (NCRP) thus recommends a risk factor of 5 ⫻ 10⫺2 Sv⫺1 for lifetime cancer mortality for the general population (18). Conceptually, this means that if a randomly selected population of 100 people each received an effective dose (ED; see the Appendix for approaches to calculating the radiation burden) of 1 Sv (100 rem), which is equivalent to a uniform whole-body absorbed dose of 1 Gy (100 rad) of sparsely ionizing radiation (such as diagnostic X-rays), five additional fatal cancers would ensue over the balance of the lifetimes of the irradiated individuals. The BEIR V Committee (19) endorsed a somewhat-higher risk factor of 7.9 ⫻ 10⫺2 Sv⫺1. Importantly, as lifetime risk factors for the general population, these represent age- and genderaveraged values. However, in the patient population of Coles et al. (11), the population was skewed toward older individuals, with a mean age of approximately 62 years. For such an older population, the risk factor for lifetime cancer mortality is less than one-half of that for the general population and less than one-third of that for a younger population (i.e., younger than 55 years of age) (20). The use of general-population (i.e., age-averaged) risk factors will therefore overestimate the actual radiogenic risk to older patients, that is, patients typically being evaluated for coronary artery disease. Although modern fluoroscopy systems automatically adjust the amount of radiation delivered for body size, presumably resulting in a uniformly low ED among patients, automatic adjustment of tube current (milliampere, mA) and tube current-time (milliampere-second, mAs) are not yet incorporated into CT scanning protocols. However, MSCT scanning techniques are being developed to reduce patient radiation dose (21). For example, because the X-ray beam attenuation is less in the shorter posterioroanterior direction than in the longer lateral direction, fewer incident photons will be required to achieve the same degree of projection-image mottle (“noise”) when the tube is anterior and posterior to the patient. The radiation dose may therefore be reduced by decreasing the X-ray tube current when in these positions relative to the patient. Alternatively, the X-ray tube may be prospectively triggered to generate X-rays only during predetermined portions (e.g., ventricular diastole) of the R-R interval of the cardiac cycle, when cardiac motion artifacts are less likely. For prospectively triggered calcium-scoring CT, for example, the ED is only 1 mSv, 25% to 40% of that for retrospectively triggered calcium-scoring examinations (2.6 to 4.1 mSv), and approximately equivalent to the low ED (⬃1 mSv) of electron-beam CT calcium scoring and angiography (22). When weighing the relative risk of any medical procedure, it is imperative that one consider the overall risk of alternative procedures. In the current report, Coles et al.

1848

Zanzonico et al. Risk Has its Reward

(11) rigorously analyzed the radiation dose and attendant risk associated with MSCT angiography versus selective diagnostic coronary angiography in the same patients and, consistent with previous reports, found a substantially higher radiation dose for MSCT angiography (ED was approximately 14 mSv) than for CCA (ED was approximately 6 mSv). On the basis of the general-population risk factor of 5 ⫻ 10⫺2 Sv⫺1 for lifetime cancer mortality (23), the risk of inducing a fatal cancer is therefore 0.07% for MSCT angiography and 0.02% for CCA. However, as reported by Noto et al. (24) in more than 59,000 patients undergoing CCA, the nonradiogenic risk of mortality is 0.11% and of a major complications (excluding contrast reactions) is 1.3%. Most, if not all, of these serious noncontrast adverse events are a consequence of cardiac catherization and therefore would be avoided with the use of MSCT angiography. Accordingly, combining the radiogenic and nonradiogenic risks (0.02% and 0.11%, respectively) yields an overall risk of mortality of 0.13% for CCA—nearly twofold greater than for angiography (0.07%). Moreover, if one were to use the lower, more age-appropriate risk factors for the patient population in question, as discussed previously, the radiogenic risks of both CCA and MSCT would be reduced by about one-half (to lifetime risks of cancer mortality of about 0.065% and 0.035%, respectively), widening the overall safety ratio of MSCT angiography relative to CCA. For an equivalent clinical diagnostic efficacy of MSCT angiography and CCA (25–33), MSCT angiography emerges as the safer of these two alternatives, despite its higher radiation dose. If the entire 18,800,000 people comprising the 50- to 55-year-old population of the U.S. (34) were screened for coronary artery disease using MSCT, the anticipated increase in the number of fatal cancers would be 14,900. If this screening were repeated every five years until the population reached the age of 70, the aggregate increased risk would be increased by approximately threefold, to 42,900. Because the average age of patients with their first infarction is 65.8 for men and 70.4 for women (8) and because 94% of patients had ⬎75% stenosis in at least one vessel (35), these sequential procedures should identify patients with significant stenoses before their initial event. If this procedure prevented even 10% of the estimated 355,000 sudden deaths (8) each year, the trade-off would be well worthwhile. Reprint requests and correspondence: Dr. H. William Strauss, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10021. E-mail: [email protected].

REFERENCES 1. Wikipedia, The Free Encyclopeida. Available at: http://en. wikipedia.org/wiki/Risk. Accessed February 15, 2006. 2. Morcos SK, Thomsen HS. Adverse reactions to iodinated contrast media. Eur Radiol 2001;11:1267–75. 3. Mortele KJ, Oliva MR, Ondategui S, Ros PR, Silverman SG. Universal use of nonionic iodinated contrast medium for CT: evalu-

JACC Vol. 47, No. 9, 2006 May 2, 2006:1846–9

4. 5. 6. 7. 8. 9.

10.

11.

12.

13. 14. 15. 16. 17. 18.

19. 20. 21. 22. 23.

24.

25.

26. 27.

ation of safety in a large urban teaching hospital. Am J Roentgenol 2005;184:31– 4. Cochran ST, Bomyea K, Sayre JW. Trends in adverse events after IV administration of contrast media. Am J Roentgenol 2001;176:1385– 8. Jacobs JF, Birnbaum BA, Langlotz CP. Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology 1998;219:411– 6. Pepine CJ, Allen HD, Bashore TM, et al. ACC/AHA guidelines for cardiac catheterization and cardiac catheterization laboratories. Circulation 1991;84:2213– 46. Scanlon PJ, Faxon DP, Audet AM, et al. ACC/AHA guidelines for coronary angiography. J Am Coll Cardiol 1999;33:1756 – 824. Heart Facts 2005 update. Available at: http://www.americanheart.org/ downloadable/heart/1105390918119HDSStats2005Update.pdf. Accessed February 15, 2005. Gibbons RJ, Abrams J, Chatterjee K, et al. ACC/AHA 2002 Guideline Update for the Management of Patients With Chronic Stable Angina. Available at: http://www.acc.org/clinical/guidelines/stable/ stable.pdf. Accessed February 15, 2006. Anand DV, Lim E, Raval U, Lipkin D, Lahiri A. Prevalence of silent myocardial ischemia in asymptomatic individuals with subclinical atherosclerosis detected by electron beam tomography. J Nucl Cardiol 2004;11:450 –7. Coles DR, Smail MA, Negus IS, et al. Comparison of radiation doses from multislice computed tomographic coronary angiography and conventional diagnostic angiography. J Am Coll Cardiol 2006;47: 1840 –5. Kochanek KD, Murphyu SL, Anderson RN, Scott C. National vital statistics reports. Deaths: Final data for 2002. Available at: http:// www.cdc.gov/nchs/data/nvsr/nvsr53/nvsr53_05.pdf. Accessed February 15, 2006. Preston RJ. Radiation biology: concepts for radiation protection. Health Phys 2005;88:545–56. Wei L. Health survey in high background radiation areas in China. Science 1980;209:877– 80. Wei LX, Sugahara T, High background radiation area in China. J Radiat Res 2000;41 Suppl:1–76. Pukkala E, Aspholm R, Auvinen A, et al Incidence of cancer among Nordic airline pilots over five decades: occupational cohort study. BMJ 2002;325:567–72. Langner I, Blettner M, Gundestrup M, et al. Cosmic radiation and cancer mortality among airline pilots: results from a European cohort study (ESCAPE). Radiat Environ Biophys 2004;42:247–56. National Council on Radiation Protection and Measurements. Risk Estimates for Radiation Protection. Bethesda, MD: National Council on Radiation Protection and Measurements (NCRP) Report No. 115, 1993. Biological Effects of Ionizing Radiation, National Research Council Committee (BEIR V). Health Effects of Exposure to Low Levels of Ionizing Radiation. Washington, DC: National Academy Press, 1990. Koenig TR, Wolff D, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury. AJR Am J Roentgenol 2001;177:3–11. Mahesh M. Fluoroscopy: patient radiation exposure issues. Radiographics 2001;21:1033– 45. Morin RL, Gerber TC, McCollough CH. Radiation dose in computed tomography of the heart. Circulation 2003;107:917–22. Koenig TR, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient. AJR Am J Roentgenol 2001;177:13–20. Noto TJ Jr., Johnson LW, Krone R, et al. Cardiac catheterization 1990: a report of the Registry of the Society for Cardiac Angiography and Interventions (SCA&I). Cathet Cardiovasc Diagn 1991; 24:75– 83. Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographicallygated, multislice spiral computed tomography. Circulation 2001;103: 2535– 8. Achenbach S, Ulzheimer S, Baum U, et al. Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 2000;102:2823– 8. Cademartiri F, Luccichenti G, Marano R, et al. Non-invasive angiography of the coronary arteries with multislice computed tomography:

Zanzonico et al. Risk Has its Reward

JACC Vol. 47, No. 9, 2006 May 2, 2006:1846–9

28. 29. 30.

31. 32.

state of the art and future prospects. Radiol Med (Torino) 2003; 106:284 –96. Cademartiri F, Marano R, Runza G, et al. Non-invasive assessment of coronary artery stent patency with multislice CT: preliminary experience. Radiol Med (Torino) 2005;109:500 –7. Cademartiri F, Pavone P. Computed tomography coronary angiography with a 16-row multislice scanner: early experience and technical considerations. Acta Biomed Ateneo Parmense 2004;75:63– 8. Galia M, Lo Casto A, Midiri M, et al. Virtual bronchoscopy in patients with central endobronchial stenosing lesions. Technique optimisation with single slice spiral CT. Radiol Med (Torino) 2004; 108:28 –38. Mollet NR, Cademartiri F, de Feyter PJ. Non-invasive multislice CT coronary imaging. Heart 2005;91:401–7. Mollet NR, Cademartiri F, Nieman K, et al. Noninvasive assessment of coronary plaque burden using multislice computed tomography. Am J Cardiol 2005;95:1165–9.

1849

33. Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 2002;106:2051– 4. 34. U.S. Census Bureau Fact Finder. Sex by age. Available at: http://factfinder.census.gov/servlet/DTTable?_bm⫽y&-geo_ id⫽01000US&-ds_name⫽DEC_2000_SF1_U&-mt_name⫽DEC_ 2000_SF1_U_PCT012. Accessed February 15, 2006. 35. Liberthson RR, Nagel EL, Hirschman JC, Nussenfeld SR, Blackbourne BD, Davis JH. Pathophysiologic observations in prehospital ventricular fibrillation and sudden cardiac death. Circulation 1974;49: 790 – 8.

APPENDIX For the technical aspects of radiation exposure, please see the online version of this article.