RT Technique Evaluation Report Abstract: Technique evaluation of Radiographic Testing of circumference weld of 1 ½” Dia. Pipe / fittings using Double Wall Single Image (DWSI) technique.

Site Query Reference: 1. Sub-contractor 2. Query No.

- Burntisland fabrication Ltd - 154 rev.0, Dated 04.04.09

Technique Parameters: 1. 2. 3. 4. 5.

Size of weld joint Source Type of film used Technique No. of exposure

- Dia. 1 ½” x 5.1 WT: - Se 75, Focal spot size - 2.5 x 2.5, Effective Focal Spot size - 3.5 - Agfa D4 - Double Wall Single Image ( DWSI ) - 5

Technique Evaluation: The radiographic sample films of one complete weld joint has been reviewed and observed the following points: 1. Technique used is DWSI : ™ Radiation pass through two walls and only the weld on the film side wall is viewed for acceptance on the radiograph. ™ When complete coverage is required for circumferential welds, number of exposure / shot to cover the complete circumference with adequate overlap between the exposure. Source

Object

Film

2. Geometric Unsharpness (Ug) :

Source

Object

Source to Object Distance (SOD)

Object to Film Distance (OFD) Film Effective Focal Spot Size x OFD Ug =

3.5 x 5.1 =

SOD

=

0.413 mm

43.2

Ug (max) value allowed as per ASME V, Article 2 , T-274.2 is 0.51mm

Geometric Unsharpness Ug is within limit

3. IQI Sensitivity : Type IQI used: Wire type , 10 Fe EN, in accordance with EN 462-1 IQI sensitivity review status: Film -1 & 2 : Wire W13 (0.2mm) was visible with 50% confident level Film – 3,4 & 5 : Wire W13 (0.2mm) was visible with 100% confident level Least wire dia of IQI visible % of Sensitivity =

x 100 Penetrated Thickness

Considered penetrated thickness in accordance with ASME V para, T-276.2 (a) ie, Penetrated thickness = wall thickness + weld cap height + root penetration 0.2 % of sensitivity =

= 2.8 5.1 +1+1

4. Conclusion: ™ Based on the above technical evaluation, the proposed DWSI technique used on Ø1 ½” x 5.1 mm WT is proves the achievement of required quality level. ™ Suggest to use this technique, subject to the following notes to Bifab, ™ Avoid the fouling of image of source side WT into the film side WT ™ Make sure 100% confident level visibility of penetrameter wire -13 ™ No. of exposure shall be minimum 5 as in the technique qualification.

Evaluated by, R.Baskar Project QS Engineer - Vetcogray ASNT Level 3 RT,UT, PT & MT AWS-SCWI CSWIP3.2