S60

61 downloads 5504 Views 108KB Size Report
SENSOR. This sensor can be mounted directly onto the supply or return of the ventilation ... SENSOR. This sensor is intended for temperature control for hot or.
REMOTE TEMPERATURE SENSORS FOR CONTROL & CHANGEOVER APPLICATIONS • S60 • S70 DESCRIPTION

·• S80 ·• S90

S60 DUCT SENSOR

The model S60, S70, S80, S90 sensors are part of Viconics' Micro-Stat & Unistat Series low voltage RHVAC room temperature and humidity controls line.

Duct sensor adapter for thermostat. This sensor can be mounted directly onto the back of thermostats. This transforms the thermostats into duct mounted thermostats.

APPLICATIONS The sensors are designed for wall, duct, immersion or changeover applications. • Remote room temperature control. • Remote control of duct return air temperature. • Remote control of duct supply air temperature. • Limitation of supply temperature. • Auto changeover of VAV damper operation with supply air temperature. • Hot water temperature control. • Auto changeover of valve operation with supply water temperature.

S70 DUCT SENSOR WITH JUNCTION BOX This sensor can be mounted directly onto the supply or return of the ventilation duct depending on the application. The thermostat can then be mounted on the wall or a remote panel.

S80 ROOM SENSOR WIRING Wire lengths may exceed 100 feet without causing temperature errors, due to the high 47,000 ohm resistance.

This sensor can be mounted in any remote location. The thermostat can then be mounted on the wall or a remote panel.

Avoid running long sensor leads closed to, or in the same conduit as, high voltage and power wiring. Four sensors may be wired in series / parallel combination in order to obtain average temperature readings. SPECIFICATIONS Operating Conditions: -18 °C to 82 °C ( 0 °F to 180 °F ) - 0% to 95% R.H. non-condensing Sensor: Interchangeability: Accuracy:

Local 47 K NTC thermistor ± 1 °C @ 25 °C ( ± 1.8 °F @ 77 °F ) ± 2 °C ( for –18 to 82 °C ) ± 3.6 °F ( for 0 to 180 °F )

S90 IMMERSION SENSOR This sensor is for the control of hot or cold water, or other fluids. It can be mounted in a standard ¼” well or strap mounted to a pipe. It is constructed of 316 stainless steel.

APPLICATIONS

DIMENSIONS

S60

MICRO-STAT

0.5" ( 12.7 mm )

3.77" ( 95.8 mm )

20 25

2

15

30 10

S90 C

PIPE

0.9" ( 22.8 mm )

1.6" ( 40.6 mm )

LIQUID

1/4" BORE-THRU COMPRESSION FITTING OR WELL

S70

MICRO-STAT

1.275" MOUNTING HARDWARE

3.77" ( 95.8 mm )

S60 0.9" ( 22.8 mm )

2.8" ( 71 mm )

S70

WIDTH: 4.5" ( 114 mm )

VENTILATION DUCT

MICRO-STAT

S80

20 25 15

30

2

WIRING FROM TOP

10

C

OR FROM BACK

SECURITY SCREW

BASE

1 2 3 4 5

6 7 8 9 10

ROOM

MICRO-STAT

S80

3.275" ( 83 mm )

20 25 15

30

2

HORIZONTAL MODEL

10

C

VICONICS COVER 1.275" 32 mm 4.5" ( 114 mm )

2.8" ( 71 mm )

S90 6"

3" 1/4"

Viconics Electronics Inc. 9245, Langelier Blvd, St-Leonard, Quebec, Canada H1P 3K9 028-2301